MODELING ANISOTROPIC EFFECTS OF CARBON FIBER REINFORCED EPOXY COMPOSITES IN FIRE ENVIRONMENTS.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift and fluctuate, while the thermoplastic insulated cables, the instrument reading fell off-scale rapidly. From an operational point of view, the latter failure characteristics would likely be identified as a failure from the effects of fire, while the former may result in inaccurate readings.
The effect of changes in the input parameters (air leakage flow rate and temperature and lubricating oil inlet flow rate and temperature) over a specified range on the flammability conditions within an aircraft engine bearing sump was investigated. An analytical study was performed to determine the effect of various parameters on the generation rate of oil vapor from oil droplets in a hot air stream flowing in a cylindrical tube. The ignition of the vapor-air mixture by an ignition source was considered. The experimental investigation demonstrated that fires would be ignited by a spark ignitor over the full range of air and oil flow rates and air temperatures evaluated. However, no fires could be ignited when the oil inlet temperature was maintained below 41.7 K (290 F). The severity of the fires ignited were found to be directly proportional to the hot air flow rate. Reasonably good correlation was found between the mixture temperature in the sump at the ignitor location and the flammability limits as defined by flammability theory; thus a fairly reliable experimental method of determining flammable conditions within a sump was demonstrated. The computerized mathematical model shows that oil droplet size and air temperature have the greatest influence on the generation rate of oil vapor.
Ion mass spectrometer measurements made as part of the University of Iowa's Plasma Diagnostic Package on the STS-3 and Spacelab 2 Space Shuttle missions sampled a variety of ion composition and collected ion current responses to gas emissions from the vehicle. The only other shuttle ion measurements were made by an Air Force Geophysics Laboratory (AFGL) quadrupole spectrometer flown on STS-4. Gas emissions change the distribution of the incoming plasma through scattering and charge transfer processes. A background flux of contaminant ion species (mostly relating to water) always exists in the near vicinity of the shuttle with a magnitude which is dependent on the look direction of the spectrometer but which varies differently with changes in the angle of attack than that of the ambient ions. There is a near shuttle wake cavity in the contaminant ion distributions which has a different spatial configuration than the wake of the ambient ions. Although water dumps produce the most persistent ion perturbations, the sources for ion current modification were best delineated from measurements made when only one or two of the Reaction Control System thrusters fired for a relatively long duration. Contaminant ion perturbations associated with such firings were observed to persist for the order of a second after the cessation of the firings. The dense thruster plumes are efficient collisional, charge exchange barriers to the passage of ambient ions. Collected ion current perturbations were more evident for firings of the rear verniers, whose plumes scatter off projecting surfaces, than for the nose thrusters. The effect of the Vernier firings was found to depend not only on the location and attitude of the spectrometer with respect to the shuttle and thruster plume direction, but also on the orientation of the local magnetic field with respect to the shuttle velocity.
Pyrotechnic shock, or pyroshock, is the transient response of a structure to loading induced by the ignition of pyrotechnic (explosive or propellant activated) devices. These devices are typically used to separate structural systems (e.g., separate a spacecraft from a launch vehicle) and deploy appendages (e.g., solar panels). Pyroshocks are characterized by high peak acceleration, high-frequency content, and short duration. Because of their high acceleration and high-frequency, pyroshocks can cause spaceflight hardware to fail. Verifying by test that spaceflight hardware can withstand the anticipated shock environment is considered essential to mission success. The Earth Observing System (EOS) AM-1 spacecraft for NASA's Mission to Planet Earth is scheduled to be launched on an Atlas IIAS vehicle in 1999, and the NASA Lewis Research Center is the launch vehicle integrator for this NASA Goddard Space Flight Center spacecraft. The EOS spacecraft was subjected to numerous ground shock tests to verify that its scientific instruments and avionics components will withstand the shock-induced vibration produced when the spacecraft separates from the launch vehicle. Shock test data from these tests represent the third largest available pyroshock database in the United States. Future spacecraft missions will directly benefit from the knowledge gained from these tests. The payload separation system used for EOS is a new system that operates by firing six separation nuts. This system was tested to verify its functional operation and to characterize the resulting shock levels. The launch vehicle contractor (Lockheed Martin Astronautics) and spacecraft contractor (Lockheed Martin Missiles & Space) completed 16 separation test firings. This resulted in an unusually large amount of pyroshock data. Typically, only one or two pyroshock test firings are performed for a spacecraft mission. Because of the size of this separation system shock database, engineers were able to perform unique statistical analyses to characterize the distribution of the test data. For example, it was proven that the shock data follow a lognormal distribution, a concept often assumed but rarely proven. The test-to-test repeatability of the shock source level was analyzed, and the effects of various test configurations and separation nut production lots were examined and quantified. Engineers investigated the change in shock level as the shock traveled from the spacecraft separation interface to the avionics components of the upper stage and analyzed the effects of the structural fidelity (simulator versus real) of the components and their weight on vibrational response. In addition, the shock attenuation with distance and across joints was quantified and compared with concepts originally generated in 1970, and the effects of separation nut preload and firing sequences effects were examined. Because of this EOS shock testing and the analyses performed at NASA Lewis, a significant amount of new information on pyroshock and its characteristics is now available to the aerospace industry. We hope that this information will help future spacecraft test planners to perform better and cheaper spacecraft separation shock tests and to better understand their test data.
Intumescent is defined as the swelling of certain substances to insulate the underlying substrate when they are heated. In this research work the effect of 150μm expandable graphite (EG) was studied on char expansion, char morphology and char composition of intumescent coating formulations (ICFs). To study the expansion and thermal properties of the coating, nine different formulations were prepared. The coatings were tested at 500 °C for one hour and physically were found very stable and well bound with the steel substrate. The morphology was studied by Scanning Electron Microscopy (SEM). The char composition was analysed by X-ray Diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. EG above than 10.8wt% expands the char abruptly with uniform network structure and affect the outer surface of the char.
Understanding post-fire forest recovery is pivotal to the study of forest dynamics and global carbon cycle. Field-based studies indicated a convex response of forest recovery rate to burn severity at the individual tree level, related with fire-induced tree mortality; however, these findings were constrained in spatial/temporal extents, while not detectable by traditional optical remote sensing studies, largely attributing to the contaminated effect from understory recovery. For this work, we examined whether the combined use of multi-sensor remote sensing techniques (i.e., 1m simultaneous airborne imaging spectroscopy and LiDAR and 2m satellite multi-spectral imagery) to separate canopy recovery from understory recovery would enable to quantify post-fire forest recovery rate spanning a large gradient in burn severity over large-scales. Our study was conducted in a mixed pine-oak forest in Long Island, NY, three years after a top-killing fire. Our studies remotely detected an initial increase and then decline of forest recovery rate to burn severity across the burned area, with a maximum canopy area-based recovery rate of 10% per year at moderate forest burn severity class. More intriguingly, such remotely detected convex relationships also held at species level, with pine trees being more resilient to high burn severity and having a higher maximum recovery rate (12% per year) than oak trees (4% per year). These results are one of the first quantitative evidences showing the effects of fire adaptive strategies on post-fire forest recovery, derived from relatively large spatial-temporal domains. Our study thus provides the methodological advance to link multi-sensor remote sensing techniques to monitor forest dynamics in a spatially explicit manner over large-scales, with important implications for fire-related forest management, and for constraining/benchmarking fire effect schemes in ecological process models.
Hot cells are used to safely shield workers from high radiation environments while allowing a process to take place within the cell's shielded enclosure, often with the assistance of remote manipulators. The interior of a cell may not be accessible by personnel for years at a time, either due to the lingering radiation environment or due to the constant use of these specialized pieces of equipment. High radiation levels are known to cause undesirable effects and changes to different materials in varying degrees. Selecting equipment for a radiation environment requires an evaluation of materials used (preferably completed assembles), to ensure all interactions of materials are known and ensure that the equipment will have a high degree of reliability and functionality over the intended life of the facility. Hot cells contain systems to support the primary purpose of the enclosure. Fire detection is one such support system. Safety of hot cell operations often establish limits on the amounts of combustibles with the cells, but the presence of some combustible materials is unavoidable. Fire detection is provided to quickly detect a fire and summon manual intervention before damage is too great. Detection may also be used to initiate fire suppression systems. As a safety system, fire detection needs to remain functional to protect the facility throughout the facility's life. Equally important is that the false alarms from the fire detection are minimized to retain confidence in the alarm system and avoid unnecessary interruptions in the hot cell operations. There are many types of fire detection available with various pros and cons. Not all types of fire detection are suited for hot cell application.
The effect of biomass share on gaseous pollutant emissions from fluidized bed co-firing of various biomass fuels with high calorific value coals have extensively been investigated to date. However, effect of co-firing of olive residues with low calorific value lignites having high ash and sulfur contents has not been studied in bubbling fluidized bed combustors. In this study, experimental results of various runs pertaining to gaseous emissions (O{sub 2}, CO{sub 2}, CO, SO{sub 2}, NO, N{sub 2}O) from METU 0.3 MWt Atmospheric Bubbling Fluidized Bed Combustor (ABFBC) test rig co-firing olive residue with indigenous lignite at different biomass shares are presented. The results reveal that co-firing increases combustion efficiency irrespective of the biomass share and that increase in biomass share reduces N{sub 2}O and SO{sub 2} emissions considerably while increasing CO emission. O{sub 2}, CO{sub 2} and NO emissions are not found sensitive to increase in biomass share. Olive residues are co-fired with high ash and sulfur containing lignite without any operational problems.
The standard magnetohydrodynamic (MHD) theory predicts that the Alfvén wave may become fire-hose unstable for β{sub ∥}−β{sub ⊥}>2. In this study, we examine the proton fire-hose instability (FHI) based on the gyrotropic two-fluid model, which incorporates the ion inertial effects arising from the Hall current and electron temperature anisotropy but neglects the electron inertia in the generalized Ohm's law. The linear dispersion relation is derived and analyzed which in the long wavelength approximation, λ{sub i}k→0 or α{sub e}=μ{sub 0}(p{sub ∥,e}−p{sub ⊥,e})/B{sup 2}=1, recovers the ideal MHD model with separate temperature for ions and electrons. Here, λ{sub i} is the ion inertial length and k is the wave number. For parallel propagation, both ion cyclotron and whistler waves become propagating and growing for β{sub ∥}−β{sub ⊥}>2+λ{sub i}{sup 2}k{sup 2}(α{sub e}−1){sup 2}/2. For oblique propagation, the necessary condition for FHI remains to be β{sub ∥}−β{sub ⊥}>2 and there exist one or two unstable fire-hose modes, which can be propagating and growing or purely growing. For large λ{sub i}k values, there exists no nearly parallel FHI leaving only oblique FHI and the effect of α{sub e}>1 may greatly enhance the growth rate of parallel and oblique FHI. The magnetic field polarization of FHI may be reversed due to the sign change associated with (α{sub e}−1) and the purely growing FHI may possess linear polarization while the propagating and growing FHI may possess right-handed or left-handed polarization.
Pyrolysis products of biomass (bio-oils) have been shown to cause a reduction in NOx emissions when used as reburn fuels in combustion systems. When these bio-oils are processed with lime, calcium is ion-exchanged and the product is called BioLime. BioLime, when introduced into a combustion chamber, pyrolyzes and produces volatile products that reduce NOx emissions through reburn mechanisms. Simultaneously, calcium reacts with SO{sub 2} to form calcium sulfate and thus reduces SO{sub 2} emissions. This paper reports the characterization of composition and pyrolysis behavior of two BioLime products and the influence of feedstock on pyrolysis products. Thermogravimetric analysis (TGA) and {sup 13}C-CP/MAS NMR techniques were used to study the composition of two biomass-based materials. The composition of the pyrolysis products of BioLime was determined in a laboratory scale flow reactor. The effect of BioLime composition on NOx and SO{sub 2} reduction performance was evaluated in a 146.5 kW pilot-scale, down fired combustor (DFC). The effect of pyrolysis gas composition on NOx reduction is discussed. The TGA weight loss curves of BioLime samples in an inert atmosphere showed two distinct peaks corresponding to the decomposition of light and heavy components of the BioLime and a third distinct peak corresponding to secondary thermal decomposition of char. The study also showed that BioLime sample with lower content of residual lignin derivatives and lower calcium content produced more volatile compounds upon pyrolysis in the combustor and achieved higher NOx reduction (15%). Higher yields of pyrolysis gases increased the NO reduction potential of BioLime through homogeneous gas phase reactions. Calcium in BioLime samples effectively reduced SO{sub 2} emissions (60-85%). 36 refs., 6 figs., 3 tabs.
Wildfires may increase soil emissions of trace nitrogen (N) gases like nitric oxide (NO) and nitrous oxide (N 2 O) by changing soil physicochemical conditions and altering microbial processes like nitrification and denitrification. When 34 studies were synthesized, we found a significant increase in both NO and N 2 O emissions up to 1 year post-fire across studies spanning ecosystems globally. However, when fluxes were separated by ecosystem type, we found that individual ecosystem types responded uniquely to fire. Forest soils tended to emit more N 2 O after fire, but there was no significant effect on NO. Shrubland soils showed significant increases in both NO and N 2 O emissions after fires; often with extremely large but short-lived NO pulses occurring immediately after fire. Grassland NO emissions increased after fire, but the size of this effect was small relative to shrublands. N 2 O emissions from burned grasslands were highly variable with no significant effect. To better understand the variation in responses to fire across global ecosystems, more consistent measurements of variables recognized as important controls on soil fluxes of NO and N 2 O (e.g., N cycling rates, soil water content, pH, and substrate availability) are needed across studies. We also suggest that fire-specific elements like burn severity, microbial community succession, and the presence of char be considered by future studies. Our synthesis suggests that fires can exacerbate ecosystem N loss long after they burn, increasing soil emissions of NO and N 2 O with implications for ecosystem N loss, climate, and regional air quality as wildfires increase globally.
Computer models for coal combustion are not sufficiently accurate to enable the design of pulverized coal fired furnaces or the selection of coal based on combustion behavior. Most comprehensive combustion models can predict with reasonable accuracy flow fields and heat transfer but usually with a much lesser degree of accuracy than the combustion of coal particles through char burnout. Computational fluid dynamics (CFD) modeling is recognized widely to be a cost-effective, advanced tool for optimizing the design and operating condition of the pulverized coal-fired furnaces for achieving cleaner and efficient power generation. Technologists and researchers are paying remarkable attention to CFD because of its value in the pulverized fuel fired furnace technology and its nonintrusiveness, sophistication, and ability to significantly reduce the time and expense involved in the design, optimization, trouble-shooting, and repair of power generation equipment. An attempt to study the effect of one of the operating conditions, i.e., burner tilts on coal combustion mechanisms, furnace exit gas temperature (FEGT), and heat flux distribution pattern, within the furnace has been made in this paper by modeling a 210 MW boiler using commercial CFD code FLUENT. 5 refs., 8 figs.
Verified models of fire precursor transport in low and partial gravity: a. Development of models for large-scale transport in reduced gravity. b. Validated CFD simulations of transport of fire precursors. c. Evaluation of the effect of scale on transport and reduced gravity fires. Advanced fire detection system for gaseous and particulate pre-fire and fire signaturesa: a. Quantification of pre-fire pyrolysis products in microgravity. b. Suite of gas and particulate sensors. c. Reduced gravity evaluation of candidate detector technologies. d. Reduced gravity verification of advanced fire detection system. e. Validated database of fire and pre-fire signatures in low and partial gravity.
Fire emissions of gases and aerosols alter atmospheric composition and have substantial impacts on climate, ecosystem function, and human health. Warming climate and human expansion in fire‐prone landscapes exacerbate fire impacts and call for more effective management tools. Here we developed a global fire forecasting system that predicts monthly emissions using past fire data and climate variables for lead times of 1 to 6 months. Using monthly fire emissions from the Global Fire Emissions Database (GFED) as the prediction target, we fit a statistical time series model, the Autoregressive Integrated Moving Average model with eXogenous variables (ARIMAX), in over 1,300 different fire regions. Optimized parameters were then used to forecast future emissions. The forecast system took into account information about region‐specific seasonality, long‐term trends, recent fire observations, and climate drivers representing both large‐scale climate variability and local fire weather. We cross‐validated the forecast skill of the system with different combinations of predictors and forecast lead times. The reference model, which combined endogenous and exogenous predictors with a 1 month forecast lead time, explained 52% of the variability in the global fire emissions anomaly, considerably exceeding the performance of a reference model that assumed persistent emissions during the forecast period. The system also successfully resolved detailed spatial patterns of fire emissions anomalies in regions with significant fire activity. This study bridges the gap between the efforts of near‐real‐time fire forecasts and seasonal fire outlooks and represents a step toward establishing an operational global fire, smoke, and carbon cycle forecasting system.
Performance estimates were made for a series of integrated coal gasification combined cycle (IGCC) power systems using three generic types of coal gasification subsystems. The objectives of this study were (1) to provide a self consistent comparison of IGCC systems using different types of gasifiers and different oxidants and (2) to use this framework of cases to evaluate the effect of a gas turbine firing temperature and cooling approach an overall system efficiency. The basic IGCC systems considered included both air and oxygen blown versions of a fluidized bed gasifier, represented by the Westinghouse design, and an entrained bed gasifier, represented by the Texaco design. Also considered were systems using an oxygen blown, fixed bed gasifier, represented by the British Gas Corporation (BGC) slagging gasifier. All of these gasifiers were integrated with a combined cycle using a gas turbine firing temperature of 1700 K (2600 F) and a compressor pressure ratio of 16:1. Steam turbine throttle conditions were chosen to be 16.6 MPa/811 K (2400 psia/1000 F) with a single reheat to 810 K (1000 F). Some of these cases were modified to allow the evaluation of the effect of gas turbine firing temperature. Turbine firing temperatures from state of the art 1365 K (2000 F) to an advanced technology 1920 K (3000 F) were analyzed. A turbine cooling technology that maintains metal temperatures below acceptable limits was assumed for each level of firing temperature. System performance comparisons were made using three advanced turbine cooling technologies for the 1920 K (3000 F) firing temperature. The results indicate that the IGCC using the BGC gasifier had the highest net system efficiency (42.1 percent) of the five gasification cases considered.