Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “field study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cloud processing of dimethyl sulfide (DMS) oxidation products limits sulfur dioxide (SO 2 ) and carbonyl sulfide (OCS) production in the eastern North Atlantic marine boundary layer

Dimethyl sulfide (DMS) is the major sulfur species emitted from the ocean. The gas-phase oxidation of DMS by hydroxyl radicals proceeds through the stable, soluble intermediate hydroperoxymethyl thioformate (HPMTF), eventually forming carbonyl sulfide (OCS) and sulfur dioxide (SO 2 ). Recent work has shown that HPMTF is efficiently lost to marine boundary layer (MBL) clouds, thus arresting OCS and SO 2 production and their contributions to new-particle formation and growth events. To date, no long-term field studies exist to assess the extent to which frequent cloud processing impacts the fate of HPMTF. Here, we present 6 weeks of measurements of the cloud fraction and the marine sulfur species methanethiol, DMS, and HPMTF made at the Atmospheric Radiation Measurement (ARM) research facility on Graciosa Island, Azores, Portugal. Using an observationally constrained chemical box model, we determine that cloud loss is the dominant sink of HPMTF in this region of the MBL during the study, accounting for 79 %–91 % of HPMTF loss on average. When accounting for HPMTF uptake to clouds, we calculate campaign average reductions in DMS-derived MBL SO 2 and OCS of 52 %–60 % and 80 %–92 % for the study period. Using yearly measurements of the site- and satellite-measured 3D cloud fraction and DMS climatology, we infer that HPMTF cloud loss is the dominant sink of HPMTF in the eastern North Atlantic during all seasons and occurs on timescales faster than what is prescribed in global chemical transport models. Accurately resolving this rapid loss of HPMTF to clouds has important implications for constraining drivers of MBL new-particle formation.

54 ENVIRONMENTAL SCIENCES↗

An underground, wireless, open-source, low-cost system for monitoring oxygen, temperature, and soil moisture

Abstract. The use of wireless sensor networks to measure soil parameters eliminates the need to remove sensors for field operations, such as tillage, thus allowing long-term measurements without multiple disturbances to soil structure. Wireless sensors also reduce above-ground cables and the risk of undesired equipment damage and potential data loss. However, implementing wireless sensor networks in field studies usually requires advanced and costly engineering knowledge. This study presents a new underground, wireless, open-source, low-cost system for monitoring soil oxygen, temperature, and soil moisture. The process of system design, assembly, programming, deployment, and power management is presented. The system can be left underground for several years without the need to change the battery. Emphasis was given on modularity so that it can be easily duplicated or changed if needed and deployed without previous engineering knowledge. Data from this type of system have a wide range of applications, including precision agriculture and high-resolution modelling.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Species-specific acoustic responses by bats to ultrasonic stimuli used for reducing bat-wind turbine interactions

An unintended consequence of wind energy generation is bat fatalities caused by wind turbine blade strikes. One potential approach to reduce collision risk is to use ultrasound to create an uncomfortable or disorienting airspace around wind turbine blades. Ultrasonic deterrents (UDs) have produced mixed results in experimental field studies at commercial wind energy facilities, with effectiveness varying by species and location. It is possible that some species can alter their normal echolocation characteristics to counter the signal of UDs. Our broad objective was to maximize the effectiveness of a UD by comparing changes in echolocation characteristics during three UD frequency emissions among species, between seasons, and between sex. We hypothesized that UD emissions with frequencies most similar to each species’ echolocation characteristics would be more likely to alter the bats’ echolocation, and bat responses would vary between seasons and sex for each species. We released wild-captured bats into a 60 m × 10 m × 4.4 m (length × width × height) flight cage located in San Marcos, Texas, USA, from July to October 2020 and March to May 2021 and monitored echolocation frequencies with ultrasonic microphones. We conducted trials on Brazilian free-tailed bats ( Tadarida brasiliensis ; n = 54), cave myotis ( Myotis velifer ; n = 44), red bats ( Lasiurus blossevilli , Lasiurus borealis ; n = 41), evening bats ( Nycticeius humeralis ; n = 32), and tricolored bats ( Perimyotis subflavus ; n = 8). We found that species with high-frequency echolocation calls altered their echolocation signatures more commonly during high-frequency UD emissions, whereas low-frequency bats altered their echolocation signatures more commonly during low-frequency UD emissions. Additionally, echolocation responses varied between seasons and sexes for several species. Variations in responses may be dependent on species migratory status, differences in mating behavior and mating season, hormonal differences between sexes and seasons, and/or constraints on echolocation adaptability. Our results offer insights into the variable effectiveness of UDs at reducing bat fatalities at wind turbines and provide information for potential adjustments to UDs for improved success.

17 WIND ENERGY↗

Eurycea lucifuga (Cave Salamander). Diet.

Eurycea lucifuga is a common and widespread facultative inhabitant of caves and springs in the southeastern and central United States (Powell et al. 2016. Peterson Field Guide to Reptiles and Amphibians of Eastern and Central North America. Houghton Mifflin Harcourt, Boston, Massachusetts. 512 pp.). This species is known to feed on a variety of invertebrates, such as snails, crustaceans, beetles, and flies (Peck 1974. Nat. Speleol. Soc. Bull. 36:7–10). Although several millipede species also can serve as prey for E. lucifuga, some are presumably avoided due to the presence of defensive secretions (e.g., Abacionidae, Paradoxosomatidae). Captive feeding trials and field study show that E. lucifuga do not actively prey upon cave-obligate Tetracion millipedes, which produce defensive secretions comprised primarily of the compound p-cresol (Peck and Richardson 1976. Annales de Speleologie 31:175–182). On the other hand, Pseudotremia millipedes, which do not possess chemical defenses, are a significant component of the diet of cave-dwelling E. lucifuga (Peck and Richardson 1976, op. cit.)

59 BASIC BIOLOGICAL SCIENCES↗

We Just Want to Pump…You Up! Forecasting Grid-Connected Heat Pump Water Heater Energy Savings and Load Shifting Potential for the Southeast U.S.

Heat pump water heaters (HPWH) can achieve energy savings of 60-70% compared to conventional electric-resistance water heaters. However, even with a favorable simple payback period within the typical product lifetime, HPWHs make up only 1% of all electric water heaters sold in the residential sector. Market adoption is challenged, in part, by the lack of effective energy efficiency programs in the U.S. region with the greatest amount of residential electric water heaters. The recent integration of connected functionality into HPWHs offers the capability to shift load without undue negative impact on customers. This capability can provide value to utilities with peak load constraints, motivating them to promote HPWHs for the first time. This paper will present a methodology to forecast connected HPWH energy use and extrapolate load shifting potential for the Southeast U.S. region. The methodology leverages data from a robust connected HPWH field study conducted in the Pacific Northwest. A coefficient of performance (COP) relationship for HPWHs was developed using ambient and inlet water temperature data to forecast HPWH performance on a month-by-month basis. Using the forecasted COP, HPWH operating hours were calculated for meeting load, which serve as the proxy to extrapolate load shifting potential from the Pacific Northwest to the Southeast. As a use case, analytical results are presented for a specific utility. This methodology, in combination with market analysis, facilitates the development of customized energy savings and load shifting forecasts to understand the potential impacts of launching connected HPWH programs in specific utility service territories.

heat pump water heater, energy savings, load shift↗

Integrating Electric Vehicle Charging Infrastructure into Commercial Buildings and Mixed-Use Communities: Design, Modeling, and Control Optimization Opportunities: Preprint

This paper discusses modeling and field studies of controlled EV charging that have been performed with the goal of minimizing requirements for infrastructure upgrades, minimizing building peak demand charges, and maximizing the use of on-site generation. We present a large-scale workplace charging pilot of a demand-controlled scheduled EV charging system with over 250 active daily commuters, successfully demonstrating management of aggregate charging power to avoid new infrastructure investments, mitigate peak demand charges, and provide cost-effective workplace charging to users. In addition to understanding opportunities for demand management, integrating these controllable loads into the energy modeling process for new buildings will also be necessary. This paper then presents an example energy modeling process that evaluates the potential effects of EV charging on building load profiles and infrastructure requirements for a mixed-use community. Finally, we discuss an illustration of how EV charging can be controlled to be synergistic with other building loads and distributed generation.

buildings↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Nextracker bifacial webinar in partnership with PV Evolution Labs

This presentation for a Nextracker-sponsored virtual symposium and webinar series leveraged PVEL's DOE-funded outdoor bifacial field study to explain potential for bifacial gain in dual-axis tracker mounting configurations. Data from PVEL's study also informed the modeling findings presented by Nextracker.

Meydbray, Jenya↗

Quantifying your bifacial gain

This white paper, published by Nextracker, presents findings from PVEL's DOE-funded outdoor bifacial field study to explain potential for bifacial gain in dual-axis tracker mounting configurations. Data from PVEL's study also informed Nextracker's modeling and system design recommendations.

Meydbray, Jenya↗

Insights from PVEL's indoor and outdoor bifacial testing

This webinar presentation summarizes initial results from PVEL's DOE-funded outdoor bifacial field study at PVUSA and well as data from PVEL's indoor bifacial reliability testing. Highlights from PVEL's DOE-funded research include daily and monthly bifacial gains by manufacturer over different albedos and by time of day.

Erion-Lorico, Tristan↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Evaluation of Techniques for Vegetation Removal from UAV-Based Photogrammetric DSM near WIPP Land Withdrawal Act Boundary, NM

The Waste Isolation Pilot Plant is located within New Mexico's karst landscape and is the United States' only deep geologic radioactive waste repository which isolates transuranic waste from defense activities underground in a bedded salt formation. Characteristic karst topography in this region is made up of material (such as limestone) that can be dissolved by water over a long period of time, and includes features such as springs, surface streams, sinking streams, caves, and sinkholes. Karst features can potentially impact the integrity of the waste repository in the future and compromise WIPP's performance, particularly when coupled with incompatible land-use activities within the Land Withdrawal Act (LWA) boundary as well as increased water withdrawals outside the LWA. In order to better capture the ground surface topography to support hydrology modeling efforts, the U.S. DOE has enlisted FIU to develop a high-resolution digital elevation model (DEM). In a previous field study, a high-resolution digital surface model (DSM) of an adjacent representative site, Basin 6, was developed by photogrammetry using aerial images captured with unmanned aerial vehicles. The DSM generated was based on point clouds representing the entire landscapes, including points of terrain, vegetation and infrastructure. These above-ground features need to be removed to create a DSM/DEM with good representation of the bare ground. In recent years, many techniques including both pre- and post-processing of DSMs, were developed for vegetation removal with varied success. This research focuses on applying and comparing various vegetation removal methods using point clouds generated of the Basin 6 pilot study area. The 3D RGB-based point cloud classification using Python scripts was a modification of the procedure by Themistocleous (2019). The method using Liblas classifies the point cloud three-dimensionally, whereas the method by Themistocleous (2019) is two-dimensional. The preliminary result of the method using Liblas, however, still had a large amount of vegetation remaining compared to the Pix4D Machine Learning method. The vegetation layer remains highly visible in the DEMs processed using the vegetation indices as opposed to the Pix4D Machine Learning method, which produces a DEM where mostly bare ground is seen. Further modifications to the input parameters are required to improve the vegetation vs. bare ground classification using this approach. The next step will be to improve the method using Liblas and to also test other vegetation removal methods found in the literature review to compare them against the two described here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Microbial Biomass in Soils Receiving Varying Levels of Organic Inputs - A Data Compilation

This dataset contains soil microbial biomass data compiled from published laboratory studies and field manipulations of organic inputs to soils. Each study included at least three levels of a given type of organic input applied to a given type of soil. Studies were selected from the literature that had experimentally manipulated organic input rates to soils using unburned, non-synthetic material (e.g. plant litters, manures, and composts). Fifty-five (55) studies, conducted from 1997 to October 2019, were chosen and compiled into a dataset with 358 observations from 96 combinations of a given organic material applied to a given soil in agricultural systems, laboratory incubations, forests, or grasslands. • Studies were selected when biomass measurements used the chloroform fumigation-extraction procedure followed by carbon analysis, or, in two instances, studies estimated microbial biomass using phospholipid fatty acid analysis. • Studies that used fewer than three input rates or characterized microbial biomass via substrate induced respiration were excluded. • The temporal and spatial aspects of the laboratory and field studies were not essential to the analyses (Craig et al., 2021) and were not included with the measurement data. These data were used to assess the relationship between organic input amounts and microbial biomass. Complete reference citations are provided if additional information is needed. The compiled data are provided in two .csv files: (1) soil treatments and microbial biomass data and (2) literature citations. The “Study” field is the cross reference between files. Also provided is the R code for reproducing the results in the related publication.

54 ENVIRONMENTAL SCIENCES↗

Qubit Regularization of Quantum Field Theories

To study quantum field theories on a quantum computer, we must begin with Hamiltonians defined on a finite-dimensional Hilbert space and then take appropriate limits. This approach can be seen as a new type of regularization for quantum field theories, which we refer to as qubit regularization. A related finite-dimensional regularization, known as the D-theory approach, was proposed long ago as a general framework for all quantum field theories. In this framework, the dimensionality of the local Hilbert space at each spatial point can increase as needed through an additional flavor index. To reproduce asymptotically free QFTs, most studies assume that qubit-regularized theories require extending the local Hilbert space to infinity. However, contrary to this common belief, recent discoveries in (1+1) dimensions have revealed two examples where asymptotic freedom appears to emerge within a strictly finite-dimensional local Hilbert space through a novel renormalization group (RG) flow. These findings motivate further investigation into whether asymptotically free gauge theories could also emerge within a strictly finite-dimensional local Hilbert space. To support these explorations, we propose an orthonormal basis called the monomer-dimer-tensor-network (MDTN) basis and use it to construct new types of qubit-regularized lattice gauge theories.

Chandrasekharan, Shailesh [Duke Univ., Durham, NC ↗