Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Non-perturbative Approach to Computing Seismic Normal Modes in Rotating Planets

In this work, a continuous Galerkin method based approach is presented to compute the seismic normal modes of rotating planets. Special care is taken to separate out the essential spectrum in the presence of a fluid outer core using a polynomial filtering eigensolver. The relevant elastic-gravitational system of equations, including the Coriolis force, is subjected to a mixed finite-element method, while self-gravitation is accounted for with the fast multipole method. Our discretization utilizes fully unstructured tetrahedral meshes for both solid and fluid regions. The relevant eigenvalue problem is solved by a combination of several highly parallel and computationally efficient methods. We validate our three-dimensional results in the non-rotating case using analytical results for constant elastic balls, as well as numerical results for an isotropic Earth model from standard “radial” algorithms. We also validate the computations in the rotating case, but only in the slowly-rotating regime where perturbation theory applies, because no other independent algorithms are available in the general case. The algorithm and code are used to compute the point spectra of eigenfrequencies in several Earth and Mars models studying the effects of heterogeneity on a large range of scales.

58 GEOSCIENCES↗

CrysFieldExplorer : rapid optimization of the crystal field Hamiltonian

A new approach to the fast optimization of crystal electric field (CEF) parameters to fit experimental data is presented. This approach is implemented in a lightweight Python-based program, CrysFieldExplorer. The main novelty of the method is the development of a unique loss function, referred to as the spectrum characteristic loss (L Spectrum ), which is based on the characteristic polynomial of the Hamiltonian matrix. Particle swarm optimization and a covariance matrix adaptation evolution strategy are used to find the minimum of the total loss function. It is demonstrated that CrysFieldExplorer can perform direct fitting of CEF parameters to any experimental data such as a neutron spectrum, susceptibility or magnetization measurements etc. CrysFieldExplorer can handle a large number of non-zero CEF parameters and reveal multiple local and global minimum solutions. Crystal field theory, the loss function, and the implementation and limitations of the program are discussed within the context of two examples.

42 ENGINEERING↗

Gravitational waves from an inflation triggered first-order phase transition

Large excursion of the inflaton field can trigger interesting dynamics. One important example is a first-order phase transition in a spectator sector which couples to the inflaton. Gravitational waves (GWs) from such a first-order phase transition during inflation, an example of an instantaneous source, have an oscillatory feature. In this work, we show that this feature is generic for a source in an era of accelerated expansion. We also demonstrate that the shape of the GW signal contains information about the evolution of the early universe following the phase transition. In particular, the slope of the infrared part of the GW spectrum is sensitive to the evolution of the Hubble parameter when the GW modes reenter the horizon after inflation. The slope of the profile of the intermediate oscillatory part and the ultraviolet part of the GW spectrum depend on the evolution of the Hubble parameter when the modes exit horizon during the inflation and when they reenter the horizon during the reheating. The ultraviolet spectrum also depends on the details of the dynamics of the phase transition. We consider the GW signal in several models of evolution during and after inflation, and compare them with the minimal scenario of quasi- de Sitter inflation followed by radiation domination after a fast reheating, and demonstrate that the shape of the GW can be used to distinguish them. In this way, the GW signal considered in this paper offers a powerful probe to the dynamics of the early universe which is otherwise difficult to explore directly through CMB, large scale structure, big bang nucleosynthesis (BBN), and other well-studied cosmological observables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral characterization of an SPDC source with a fast broadband spectrometer

Knowing the properties of single photons produced in a Spontaneous Parametric Down-Conversion (SPDC) source can be crucial for specific applications and uses. In particular, the spectral properties are of key relevance. Here, we investigate a commercial SPDC source using our fast broadband spectrometer. Our analysis is a valid method for other SPDC sources, as well as other single-photon generation techniques, thus providing a good example of how to use this spectrometer design. We calibrate the spectrometer using known lines of the argon emission spectrum. We show that the two down-converted photons from the SPDC source have different spectral properties depending on the pump power, and under which condition we measured spectrally similar down-converted photons. Finally, we were able to reconstruct and investigate the spectral information for the pump photon.

79 ASTRONOMY AND ASTROPHYSICS↗

Stellar population analysis of MaNGA early-type galaxies: IMF dependence and systematic effects

We study systematics associated with estimating simple stellar population (SSP) parameters – age, metallicity [M/H], α-enhancement [α/Fe], and initial mass function (IMF) shape – and associated M * /L gradients, of elliptical slow rotators (E-SRs), fast rotators (E-FRs), and S0s from stacked spectra of galaxies in the MaNGA survey. These systematics arise from (i) how one normalizes the spectra when stacking; (ii) having to subtract emission before estimating absorption line strengths; (iii) the decision to fit the whole spectrum or just a few absorption lines; (iv) SSP model differences (e.g. isochrones, enrichment, IMF). The MILES+Padova SSP models, fit to the H β , 〈Fe〉, TiO 2SDSS , and [MgFe] Lick indices in the stacks, indicate that out to the half-light radius R e : (a) ages are younger and [α/Fe] values are lower in the central regions but the opposite is true of [M/H]; (b) the IMF is more bottom-heavy in the center, but is close to Kroupa beyond about R e /2; (c) this makes M * /L about 2 × larger in the central regions than beyond R e /2. While the models of Conroy et al. return similar [M/H] and [α/Fe] profiles, the age and (hence) M * /L profiles can differ significantly even for solar abundances and a Kroupa IMF; different responses to non-solar abundances and IMF parametrization further compound these differences. There are clear (model independent) differences between E-SRs, E-FRs, and S0s: younger ages and less enhanced [α/Fe] values suggest that E-FRs and S0s are not SSPs, but relaxing this assumption is unlikely to change their inferred M * /L gradients significantly.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Microwave Resonant Cavity Transducer Degradation Mechanisms

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. Because the transducer is intended for immersion in a high temperature corrosive fluid, understanding of material degradation is crucial for estimation of transducer performance lifetime, and development of measurement interpretation algorithms. We conducted a preliminary computational investigation of relevant damage mechanisms of a stainless steel 316 cylindrical resonator in FLiBe salt. The two main damage mechanisms, creep and corrosion, were modeled using multiphysics COMSOL software. Degradation was modeled for a temperature range 500°C to 700°C. Coupling of the damage mechanisms was not considered. These models predict significant inelastic deformation at most temperatures due to creep, and qualitatively predict chromium depletion both along the liquid/solid interface and along the grain boundaries. An algorithmic approach for compensation of these degradation effects during fluid flow measurements will be developed in the future work. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed. Approximate figure of merit of sensitivity to flow rate is 100KHz/GPM. In addition, we have identified an existing liquid sodium experimental setup for demonstration of flow sensing in environment similar to that of an advanced reactor. The setup consists of a cylindrical vessel and center feed line, where transducer inserted through the lid will measure velocity of the impinging liquid jet. As a calibration experiment, we have assembled a water vessel with center feed with the same dimensions as those of the liquid sodium setup. We have also developed and insertion probe consisting of a 50cm brass waveguide enclosed in protective SS316 tube. Using the water loop, we have demonstrated feasibility of sensing the impinging liquid jet in the vessel.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the analysis of signal peaks in pulse-height spectra

The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deducing neutron star equation of state from telescope spectra with machine-learning-derived likelihoods

The interiors of neutron stars reach densities and temperatures beyond the limits of terrestrial experiments, providing vital laboratories for probing nuclear physics. While the star's interior is not directly observable, its pressure and density determine the star's macroscopic structure which affects the spectra observed in telescopes. The relationship between the observations and the internal state is complex and partially intractable, presenting difficulties for inference. Previous work has focused on the regression from stellar spectra of parameters describing the internal state. We demonstrate a calculation of the full likelihood of the internal state parameters given observations, accomplished by replacing intractable elements with machine learning models trained on samples of simulated stars. Our machine-learning-derived likelihood allows us to perform maximum a posteriori estimation of the parameters of interest, as well as full scans. We demonstrate the technique by inferring stellar mass and radius from an individual stellar spectrum, as well as equation of state parameters from a set of spectra. Our results are more precise than pure regression models, reducing the width of the parameter residuals by 11.8% in the most realistic scenario. The neural networks will be released as a tool for fast simulation of neutron star properties and observed spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison Study of Upper Subcritical Limits Derived Using Sensitivity/Uncertainty Tools Case Studies of Benchmarks and Applications

Neutron transport methods used to establish subcriticality require validation by comparison to critical experiments considered to be benchmarks. Whisper is a sensitivity/uncertainty analysis tool developed to assist with the task of validation in nuclear criticality safety. Details on the Whisper methodology can be found in References 1-3 on the MCNP ® reference collection website at https://mcnp.lanl.gov. Whisper-1.0 was originally developed in 2014 and used to assist with nuclear criticality safety validation at Los Alamos National Laboratory. Whisper was upgraded in 2016 to Whisper-1.1 and prepared for release with MCNP6.2. Whisper contains a library of over 1100 critical experiment benchmarks and quantifies neutronic similarity of an application to benchmarks in the library. Using highest similarity benchmarks, Whisper computes a calculational margin (CM) encompassing of the worst-case bias and bias uncertainty at a 99% confidence level for each application. In addition, portions of the margin of subcriticality (MOS) for nuclear data uncertainty and potential code errors are computed. The baseline upper subcritical limit (USL) computed by Whisper is comprised of the CM, MOS nuclear data , and MOS code errors . The Whisper baseline USL is absent a portion of the MOS due to the area of application, which is applied based upon judgment by the criticality safety analyst. An objective of this paper is to present the baseline USL, CM and portions of the MOS as computed by Whisper for comparison with similar sensitivity/uncertainty tools, such as those used by IRSN and ORNL. The initial comparison involves four critical experiment benchmarks: HEU-MET-FAST-013-001, HEU-SOLTHERM-001-008, PU-MET-FAST-022-001, AND PU-SOL-THERM-001-001, which have been: 1. modeled independently by LANL, IRSN, and ORNL based upon information provided in the ICSBEP Handbook, 2. are common in S/U libraries for LANL, IRSN, and ORNL, 3. span a range of energy spectrum and fissile material, and 4. taken as applications for the purposes of this study and therefore excluded from use as a benchmark for calculating the upper subcritical limit. Results presented in this paper have been computed using covariance data for all isotopes in ENDF/BVII.0 using a 44-group energy structure. Benchmarks in the Whisper library were run in MCNP6.2 using 100,000 neutrons per cycle, skipping 100 cycles for 500 active cycles. Reference 10 also compares the results for baseline USL with an order of magnitude greater neutrons, using the same total number of cycles with 1,000,000 neutrons per cycle. Subsequent to the results presented in Reference 10 changes were made to the benchmark library, as discussed in Reference 11. Newer results using the revised benchmark library are presented herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast External Quantum Efficiency Measurements of Photovoltaic Modules

The external quantum efficiency (EQE) or associated spectral response is widely used to evaluate the performance of photovoltaics, light emitting diodes, photodetectors, photodiodes, semiconductor lasers, laser-induced refrigeration of solids etc. For photovoltaic (PV) devices, The EQE is used to determine the spectral mismatch correction that is used to convert a performance measurement from a non-ideal simulator spectrum to a standard spectrum in PV device calibrations. Moreover, EQE can provide important insight into the physics of a PV device. For instance, the EQE shape can be used to infer mechanisms limiting the performance of the device. However, EQE measurements of full-size PV modules remain a challenge in the PV community due to rare availability of reliable module QE measurement tools worldwide and the size and complexity of module architecture that comprises several cells connected in strings (series or/and parallel). Here, we use a customized nondestructive tool made of high-power light emitting diodes to perform high-throughput EQE measurements on PV modules. Circuit simulations show that the measurement system can safely be used to measure both crystalline silicon and thin film-based PV modules with series connected cells without the risk of damage through reverse bias. In addition, EQE mapping combined with electroluminescence show a strong correlation and provide a way to determine both spatial non-uniformity of the spectral response and defects/degradation effects across the module.

PV module↗

$\mathrm{SageNet}$: Fast Neural Network Emulation of the Stiff-amplified Gravitational Waves from Inflation

Accurate modeling of the inflationary gravitational waves (GWs) requires time-consuming, iterative numerical integrations of differential equations to take into account their backreaction on the expansion history. To improve computational efficiency while preserving accuracy, we present the Stiff-amplified Gravitational-wave Emulator Network (SageNet), a deep learning framework designed to replace conventional numerical solvers (code available at https://github.com/YifangLuo/SageNet). SageNet employs a long short-term memory architecture to emulate the present-day energy density spectrum of the inflationary GWs with possible stiff amplification, Ω GW (f). Trained on a data set of 25,689 numerically generated solutions, SageNet allows accurate reconstructions of Ω GW (f) and generalizes well to a wide range of cosmological parameters; 90.9% of the test emulations with randomly distributed parameters exhibit errors of under 4%. In addition, SageNet demonstrates its ability to learn and reproduce the artificial, adaptive sampling patterns in numerical calculations, which implement denser sampling of frequencies around changes in spectral indices in Ω GW (f). The dual capability of learning both physical and artificial features of the numerical GW spectra establishes SageNet as a robust alternative to exact numerical methods. Finally, our benchmark tests show that SageNet reduces the computation time from tens of seconds to milliseconds, achieving a speedup of ∼10 4 times over standard CPU-based numerical solvers with the potential for further acceleration on GPU hardware. These capabilities make SageNet a powerful tool for accelerating Bayesian inference procedures for extended cosmological models. In a broad sense, the SageNet framework offers a fast, accurate, and generalizable solution to modeling cosmological observables whose theoretical predictions demand costly differential equation solvers.

Astronomy data modeling↗

Multifrequency-resolved Hanbury Brown–Twiss effect

The Hanbury Brown–Twiss (HBT) effect holds a pivotal place in intensity interferometry and gave a seminal contribution to the development of quantum optics. To observe such an effect, both good spectral and timing resolutions are necessary. Most often, the HBT effect is observed for a single frequency at a time due to its limitations in dealing with multifrequencies simultaneously, halting and limiting some applications. Here, we report a fast and data-driven spectrometer built with a one-dimensional array of single-photon-sensitive avalanche diodes. We report observing the HBT effect for multiple frequencies at the same time. In particular, we observe the HBT effect for up to five lines of the Ne spectrum, but this can be improved upon to include more lines. Our work represents a major step in making spectral binning and multifrequency HBT more widely available. The technology we present can benefit both classical and quantum applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio transients and variables in the tenth Deeper, Wider, Faster observing run

The Deeper, Wider, Faster (DWF) program coordinates observations with telescopes across the electromagnetic spectrum, searching for transients on time-scales of milliseconds to days. The tenth DWF observing run was carried out in near real-time during September 2021, and consisted of six consecutive days of observations of the NGC 6744 galaxy group and a field containing the repeating fast radio burst FRB 190711 with the Australian Square Kilometre Array Pathfinder, the Dark Energy Camera, the Hard X-ray Modulation Telescope, and the Parkes 64-m ‘Murriyang’ radio telescope. Here, in this work, we present the results of an image-domain search for transient, variable, and circularly polarized sources carried out with ASKAP, using data from the observing run along with test observations prior to the run and follow-up observations carried out during and after the run. We identified eight variable radio sources, consisting of one pulsar, six stellar systems (five of which exhibit circularly polarized emission), and one previously uncatalogued source. Of particular interest is the detection of pulses from the ultra-cool dwarf SCR J1845–6357 with a period of 14.2 ± 0.3 h in good agreement with the known optical rotation period, making this the slowest rotating radio-loud ultra-cool dwarf discovered.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Third Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗