Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Correlating the influence of porosity, tortuosity, and mass loading on the energy density of LiNi 0.6 Mn 0.2 Co 0.2 O 2 cathodes under extreme fast charging (XFC) conditions

Extreme fast charging capabilities along with high energy density of Li-ion batteries are the key factors to increase the adoption of electric vehicles while eliminating the problem of range anxiety. The U.S Department of Energy has a goal of <12 min charging time with energy density of > 200 Wh kg -1 . A combined improvement in the electrode architecture, electrolyte properties, and separator membrane is necessary to achieve this goal. Cells with thin electrodes are capable of extreme fast charging at the expense of low energy density and high cost. Electrode engineering can maximize energy density. In this work, the influence of porosity, mass loading and charging protocols on capacity and energy density and electrode kinetics are investigated under extreme fast charging conditions. Increasing the mass loading from 11.5 mg cm -2 to 25 mg cm -2 compromises the rate performance due to the mass transport limitation and underutilization of thick electrodes. Furthermore, reducing the electrode porosity from 50% to 35% improves the rate performance ascribed to shorter Li ion diffusion length. Symmetric cells are cycled to verify the performance of the half cells, suggesting that Li metal plating is the rate limiting step under high current density.

25 ENERGY STORAGE↗

Extreme fast charge aging: Correlation between electrode scale and heterogeneous degradation in Ni-rich layered cathodes

Extreme fast charging (XFC) is a key requirement for the adoption of battery-based electric vehicles by the transportation sector. However, XFC has been shown to accelerate degradation, causing the capacity, life, and safety of batteries to deteriorate. There are no systematic studies in the open literature regarding aging modes in Ni-rich Li y Ni 0.a Mn 0.b Co 0.c O 2 (NMCabc) cathodes caused by fast charging. Herein, we report the effects of cathode composition and electrode loading in pouch cells containing NMC532, 622 and 811 paired with graphite and cycled under XFC conditions. The relative anisotropic volume change in the unit cell increases with Ni content in low-loading cells, while it levels up for all three NMC cathodes in high-loading cells because of substantial Li plating. The amounts of lithium plating and heterogeneity on the anode, determined by crystallographic phase quantification, were found to be correlated with electrode loading and cathode heterogeneity. The concentrations of the transition metals deposited on the anodes depend on NMCabc composition in a complex way. More particle cracking and surface degradation was found in NMC811. Here, the findings in this work provide a new understanding of the failure mechanisms and their practical implications for compositional tuning of future high-Ni NMCabc cathode materials during fast charging.

25 ENERGY STORAGE↗

Operando FTIR investigation of salt dynamics in Li-ion batteries during fast charging

Li-ion batteries, when charged at fast-charging rates ($>$2C), suffer from reduced lifetimes and can undergo catastrophic failure. During high-rate charging, Li-ions are unable to rapidly transport through high-loading electrodes ($>$4 mAh cm −2 ). This results in unequal charge distributions, potentials, and utilization of the active material, which can lead to Li plating. Li-ion concentration polarization, in which Li-ions deplete in the anode and accumulate in the cathode during charging, precedes Li plating. An operando FTIR-ATR graphite/NMC cell developed in this research captured Li-ion concentration polarization in real-time. During fast charging, decreases in Li-ion concentration ($>$95%) were measured at the back of the anode. This is the first verification of complete Li-ion depletion within the anode at high C-rates. The measurements also showed graphite stage transition. A P2D model was developed for comparison to the operando measurements. The measurements agreed with the model in some cases, but disparities existed at high C-rates and loadings. In the experiment, the Li-ion concentration often failed to recover to 1.2 M until several hours after charging, whereas the model Li-ion concentration rapidly recovered. The contrast between the model and experiment results indicates that further investigation is required to improve understanding of Li-ion concentration dynamics during fast charging.

25 - ENERGY STORAGE↗

Fast Charge Induced Phase Evolution and Element Contribution of Nickel-Rich Layered Cathode for Lithium-Ion Batteries

In nickel-rich layered cathode materials, three transition metals (TM = Ni, Co and Mn) play critical roles in Li storage performance. However, rate-dependent phase evolution and elemental contribution of nickel-rich cathode materials are not well understood, but very important for further design and development of these cathodes in high-power applications. Here, the rate-dependent phase evolution and elemental contribution of LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) cathode are investigated thoroughly by using time-resolved synchrotron-based in situ X-ray diffraction and absorption techniques. The increase of Ni content in NMC532 has been found to be the main cause of the complex structural changes, resulting in distortion of TM-O 6 octahedron and strong static vibration between TM and O coordination. It is revealed that the fast charge (10C and 30C) of NMC532 leads to intermediate Li-poor phases, shrinking of H2 phase region, and prolonged O1 phase. During high-rate charging, Co is oxidized easily in low voltage region, while Ni mainly dominates charge compensation in high voltage region. It is found that delithiation-induced local structure distortion transfers from Ni to Co sites in fast kinetic process. In conclusion, these findings provide in-depth understanding for the fast charge behavior of Ni-rich layered cathode materials and help to guide further development of advanced high-power lithium-ion batteries.

25 ENERGY STORAGE↗

Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graphite Lithiation under Fast Charging Conditions: Atomistic Modeling Insights

The charging of lithium ion batteries in a fast and safe manner is critical for promoting the mass adoption of electric vehicles. Li intercalation in graphite electrodes is known to be one of the bottlenecks during the fast charging process. The mechanism of Li diffusion in highly polarized graphite anode at high current rates remains, however, not well understood. In this work, Density Functional Theory (DFT) calculations are used to gain insights into the Li diffusion process in graphite when it is far from equilibrium under fast charging conditions. The effect of uncompensated charges on Li mobility is determined in the highly polarized regions of the anode close to the interfaces. The extra charge was found to increase the interlayer spacing in the diffusion layer and adjacent channels, increasing the diffusivity and promoting the formation of Li clusters. A concerted diffusion mechanism at the edge of high-concentration Li domains is proposed to enhance the diffusion of Li.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mechanistic Analysis of Microstructural Attributes to Lithium Plating in Fast Charging

Metallic lithium deposition on graphite anodes is a critical degradation mode in lithium-ion batteries, which limits safety and fast charge capability. A conclusive strategy to mitigate lithium deposition under fast charging yet remains elusive. Herein, we examine the role of electrode microstructure in mitigating lithium plating behavior under various operating conditions, including fast charging. The multilength scale characteristics of the electrode microstructure lead to a complex interaction of transport and kinetic limitations that significantly governs the cell performance and the occurrence of Li plating. We demonstrate, based on a comprehensive mesoscale analysis, that the performance and degradation can be significantly modulated via systematic design improvements at the hierarchy of length scales. It is found that the improvement in kinetic and transport characteristics achievable at disparate scales can dramatically affect Li plating propensity.

25 ENERGY STORAGE↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Oh, My Darling Clementine: A Detailed History and Data Repository of the Los Alamos Plutonium Fast Reactor

The Los Alamos Plutonium Fast Reactor, Clementine, provided the first fast neutron spectrum using a metallic plutonium fuel system and liquid mercury coolant. Clementine is often mentioned in the history of fast, metal-fueled, or metal-cooled designs, with little public information regarding the specifications or timeline. This paper contains a synopsis of each report regarding the development, operation, experimental results, failures, and subsequent disassembly of Clementine to explore this unique reactor within the context of modern advanced reactor development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A New Integrated Analysis Suite for Fast-Ion Study in KSTAR

Here, an integrated workflow for fast-ion analysis was developed by adapting the One Modeling Framework for Integrated Task (OMFIT) workflow manager to support a standard and unified analysis platform for KSTAR users. The newly established analysis suite offers a graphical user interface–based workflow to enable users to readily access and handle experimental data archived in various data formats and servers. Further, users can analyze the data by importing modules designed for conducting certain tasks, such as profile fitting, equilibrium reconstruction, and postprocessing of tokamak data. The procedures for preparing the inputs for fast-ion simulations are streamlined by a common workflow manager, which enables the parallel processing of various tasks to efficiently analyze large fast-ion datasets. The OMFIT platform comprises a flexible Python-based application that enables users to freely manipulate the Python scripts for applications that are unavailable in the standard workflow. The framework also offers mapping tools to translate the output data into the Integrated Modeling and Analysis Suite format to maintain application compatibility for future ITER burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARS-F/K modeling of plasma response and fast ion losses due to RMP in KSTAR

Abstract The toroidal single-fluid magnetohydrodynamic (MHD) code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) and the MHD-kinetic hybrid code MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) are utilized to study the plasma response to the n = 1 ( n is the toroidal mode number) resonant magnetic perturbation (RMP), applied to suppress the type-I edge localized mode (ELM) in a KSTAR discharge. Both the resistive-rotating and ideal-static plasma models identify strong screening of the resonant radial field harmonics of the applied RMP due to the plasma response, and predict a strong edge-peeling response of the plasma which is consistent with the optimal ELM control coil current configuration adopted in experiment. The RMP-induced radial displacement of the plasma, computed by the resistive-rotating plasma model, agrees reasonably well with that reconstructed from the measured data in the plasma core. Taking into account the drift kinetic response of fast ions, MARS-K hybrid modeling also finds quantitative agreement of the plasma core fluid pressure perturbation with experiment. Based on the MARS-F computed plasma response, a guiding-center orbit-tracing simulation finds about 0.3% of fast ion losses due the n = 1 RMP in the KSTAR ELM control experiment considered. Most losses are associated with counter-current fast ions located near the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of a synthetic fast ion loss detector model for Wendelstein 7-X

Abstract We present the first validated synthetic diagnostic for fast ion loss detectors (FILDs) in the Wendelstein 7-X (W7-X) stellarator. This model has been developed on, and validated against experimental data from, a FILD provided by the National Institute for Fusion Science (NIFS-FILD), with potential future applicability to the existing Faraday Cup FILD (FC-FILD) on W7-X as well as the scintillating FILD (S-FILD) currently under development. A workflow combining Monte Carlo codes BEAMS3D and ASCOT5 is used to track fast ions produced by neutral beam injection from the moment of ionization until they are thermalized or lost from the last closed flux surface, and from there to a virtual plane which serves as a projection of the entrance aperture to the FILD. Simulations in ASCOT5 are analyzed via a geometric method to determine the probability of transmission through the FILD aperture and onto the detector as a function of normalized momentum, pitch angle, gyrophase, and position at the virtual plane. This probability is then applied to the simulated ions arriving from the plasma, producing a simulated signal from a computationally tractable number of simulated fast ions. Simulated signals are presented for two W7-X experiments with neutral beam injection and quantitatively compared with experimental measurements from the NIFS-FILD diagnostic. An estimate of the frequency of charge-exchange with neutral particles in the edge is performed, and it is found that this process may have a significant impact on the measured signals.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First simultaneous observation of co- and counter-current fast-ion losses in the ASDEX Upgrade tokamak

In ITER and future fusion power plants, the source of the fusion born alpha particles is almost isotropic in pitch angle, thus having co- and counter-current populations. For trapped ions, the co-current side of the orbit corresponds to its outer leg, while the counter-current side corresponds to the inner leg. Understanding the mechanisms responsible for the fast-ion losses (FILs) is critical for future magnetically confined fusion power plants. To further study the interplay of fast ions with plasma instabilities, a double pinhole collimator has been developed for a Fast-Ion Loss Detector (FILD) in the ASDEX Upgrade tokamak (AUG). This new FILD opens the operational window to simultaneous measurements of the co- and counter-current ion velocity-space. In this paper, the first results for the AUG double collimator FILD detector are shown. The commissioning of this new probe is carried out in H-mode plasmas with an on-axis magnetic field $B_0 = -2.5$ T, and a plasma current $I_{\textrm{p}} = 0.7$ MA. Simultaneous co- and counter-current FILs have been measured. Both have shown a similar dependence on Ion Cyclotron Resonance Heating (ICRH) power, where the main difference is the intensity of the losses, with the co-losses being an order of magnitude larger. Toroidal Alfvén eigenmode-coherent ICRH-only losses have been identified for the co-current ions. Additionally, the presence of Edge Localized Modes during the discharge were shown to increment Neutral Beam Injection prompt losses, while partially mitigating ICRH-driven losses on both co- and counter- sides of the velocity-space. Finally, a very trapped and high gyroradius losses, with an unclear origin, have been measured in the co- and counter-current velocity-space. The computed ion trajectories show that these ions remain permanently near the vessel wall, suggesting that they are accelerated within the scrape-off layer.

ELM↗

Numerical assessment of the impact of the guiding-centre approximation on fast ion simulations in NSTX

Guiding-centre (GC) and full-orbit (FO) simulations of the beam-injected fast ion distribution and the corresponding neutron emissivity have been carried out for magnetohydrodynamics-quiescent National Spherical Torus eXperiment (NSTX) plasmas, using a combination of ASCOT5 and DRESS, to assess the suitability of the GC approximation for fast ions in NSTX. It was found that GC and FO simulations predicted substantially different steady-state distributions in both position and velocity space and different neutron emissivity profiles, leading to a 15% reduction in the predicted global neutron rate for FO relative to GC. These changes accompany a higher magnetic moment in FO, and correspond to a change in particle orbits from co-passing to trapped and stagnation orbits. ASCOT5 was also benchmarked against TRANSP/NUBEAM with input loaded entirely from TRANSP/NUBEAM output files, with agreement found between the GC simulations when finite Larmor radius (FLR) corrections were omitted. ASCOT5 FO and TRANSP/NUBEAM with FLR produced fast ion distributions which differed in localised regions, but predicted global neutron rates which agree within 3%.

ASCOT↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peer-to-Peer Energy Trading under Network Constraints Based on Generalized Fast Dual Ascent

We report the wide deployment of renewable energy resources, combined with a more proactive demand-side management, is inducing a new paradigm in both power system operation and electricity market trading, which especially boosts the emergence of the peer-to-peer (P2P) market. A more flexible local market mechanism is highly desirable in response to fast changes in renewable power generation at the distribution network level. Moreover, large-scale implementation of P2P energy trading inevitably affects the secure and economic operation of the distribution network. This paper presents a new P2P electricity trading framework with distribution network security constraints considered using the generalized fast dual ascent method. First, an event-driven local P2P market framework is presented to facilitate short-term or immediate local energy transactions. Then, the sensitivity analysis of nodal voltage and network loss with respect to nodal power injections is used to evaluate the impacts of P2P transactions on the distribution network, which ensures the secure operation of the distribution system. Thereby, the external operational constraints are internalized, and the cost of P2P energy trading can be appropriately allocated in an endogenous way. Moreover, a generalized fast dual ascent method is employed to implement distributed market-clearing efficiently. Finally, numerical results indicate that the proposed model could guarantee secure operation of the distribution system with P2P energy trading, and the solution method enjoys good convergence performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗