Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Survivable Failure Data Recorders for Spacecraft

A spacecraft may be unable to communicate critical data associated with a serious or catastrophic failure. A brief report proposes a system, somewhat like a commercial aircraft "black box," for retrieving these data. A microspacecraft attached to the prime spacecraft would continually store recent critical data from that spacecraft. If either spacecraft detected certain serious conditions of the prime spacecraft, the microspacecraft would separate from the prime spacecraft and independently transmit the stored data to Earth. Supplemental data, acquired from sensors onboard the microspacecraft, could be added to this transmission. For example, the orientation and angular rates of the prime spacecraft immediately before separation as well as pictures taken of the prime spacecraft after separation could be included. Functional enhancements over aircraft black boxes include the separation from the prime vehicle (which gains independence from the fate of that vehicle), wireless transmission of data (making physical black box recovery unnecessary), and the optional acquisition of supplemental sensor data.

Carraway, John↗

Evaluation of NETL’s Self-Healing Metallic Coating for Internal Corrosion Protection of Natural Gas Pipelines: Field Test

Steel pipelines are a safe, reliable, and affordable way to transport natural gas. However, the presence of impurities (e.g., water, carbon dioxide, and hydrogen sulfide) in the natural gas can cause internal corrosion, which can lead to pipeline leaks and failure. This paper reports on field tests of an innovative self-healing, corrosion-resistant, metallic coating developed at the National Energy Technology Laboratory (NETL) for protecting the interior surfaces of pipelines.

carbon dioxide (CO2)↗

Initial mechanical stability of cementless highly-porous titanium tibial components

Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally, the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.

56↗

Analysis of 7- X 10-foot high speed wind tunnel shaft loads in support of fan blade failure investigation

This is a report of the investigation of the High-Speed 7- X 10-Foot Wind Tunnel at NASA Langley Research Center, which experienced a catastrophic failure of all 18 Sitka spruce fan blades during operation at 0.8 Mach number on 2 July 1985. The High-Speed Tunnel, a closed-circuit/single-return atmospheric wind tunnel, had been operated since 1945 to support a wide range of subsonic aerodynamic tests and studies. The failed blade set had been in use since 1975. In addition to blade loss, the most significant damage was a bent main drive shaft for a total estimated damage loss of 1.7 million dollars. An analysis of the natural frequency characteristics as well as loads, reactions, stresses, and deflections of the fan drive system resulting from steady-state and dynamic loads due to unbalance was performed. Transient load cases were simulated by step input and ramp input loading functions intended to simulate the loss of one to nine blades (maximum unbalance forces).

Faison, Richard W.↗

PBX 9502 Failure Diameter: Addendum

In previous reports, the SURFplus reactive burn model was used to study a propagating detonation wave for PBX 9502 in an unconfined rate stick just above the failure diameter. Simulations showed that the sonic boundary condition at the HE interface leads to a boundary layer. Here we provide additional details on the steady-state flow with emphasis on the boundary layer. This confirms the previous conclusion that within the boundary layer the lead shock, which initiates the hot-spot reaction, is largely supported by transverse energy flow in the reaction zone from the interior towards the boundary. Consequently, the reactive wave along a boundary layer streamline does not correspond to a 1-D detonation wave in the sense of detonation shock dynamics; i.e. , the lead shock which initiates the reaction is not driven by the reaction energy along the streamline.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-F-T-325: On the Use of Bolus in Dosimetry and Dose Reduction for Pacemaker and Defibrillator

Purpose: Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is very large among CIEDs. Significant defects have been reported at dose as low as 0.15Gy. Failures causing discomfort have been reported at dose as low as 0.05Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2Gy limit. We investigate the use of bolus in in vivo dosimetry for CIEDs. Methods: In our clinic, high-energy beams (>10MV) are not used for patients with CIED due to neutron production. Solid water phantom measurements of out-of-field dose for a 6MV beam were performed using parallel plate chamber at different depth with and without 2cm bolus covering the chamber. In vivo dosimetry at skin surface above the pacemaker was performed with and without bolus for 3 patients with pacemaker <5cm from the field edge. Results: Chamber measured dose at depth ∼1 to 1.5cm below the skin surface, where the CIED is normally located, was reduced by ∼6% – 20% with bolus. The dose reduction became smaller at deeper depth. In vivo dosimetry at skin surface also yielded ∼20% – 60% lower dose when using bolus for the 3 patients. In general, TPS calculation underestimated the dose. The dose measured with bolus is closer to the dose at the depth of the pacemaker and less affected by contaminant electrons and linac head leakage. Conclusion: In vivo CIED dose measurements should be performed with 1 to 2cm bolus covering the dosimeter on the skin above the CIED for more accurate CIED dose estimation. The use of bolus also reduces the dose delivered to CIED.

60 APPLIED LIFE SCIENCES↗

Life Prediction Issues in Thermal/Environmental Barrier Coatings in Ceramic Matrix Composites

Issues and design requirements for the environmental barrier coating (EBC)/thermal barrier coating (TBC) life that are general and those specific to the NASA Ultra-Efficient Engine Technology (UEET) development program have been described. The current state and trend of the research, methods in vogue related to the failure analysis, and long-term behavior and life prediction of EBCITBC systems are reported. Also, the perceived failure mechanisms, variables, and related uncertainties governing the EBCITBC system life are summarized. A combined heat transfer and structural analysis approach based on the oxidation kinetics using the Arrhenius theory is proposed to develop a life prediction model for the EBC/TBC systems. Stochastic process-based reliability approach that includes the physical variables such as gas pressure, temperature, velocity, moisture content, crack density, oxygen content, etc., is suggested. Benefits of the reliability-based approach are also discussed in the report.

Shah, Ashwin R.↗

Status Report on Fast Flux Test Facility Mechanistic Fuel Failure Experiment Analysis with BISON for Post Irradiation Examination Support

The renewed interest in metallic U-Zr nuclear fuel alloy has led to a drive for deeper understanding of the mechanisms driving the phenomena observed under irradiation conditions. The Department of Energy Advanced Fuel Campaign has developed infrastructure to support metallic fuel development, including Post Irradiation Examination (PIE) of legacy Fast Flux Test Facility (FFTF) Mechanistic Fuel Failure (MFF) experiments. The PIE performed on legacy FFTF MFF experiments gives insight on metallic fuel performance and can address the lack of knowledge and scarcity of reliable data identified in several studies over recent years. Unfortunately, PIE efforts can cost significant time and resources which can impede the progress of metallic U-Zr fuel development. Metallic U-Zr fuel performance modeling can be used to inform PIE efforts on regions of interest for relevant investigations and can help understand phenomena observed in PIE. This report demonstrates the current progress of FFTF MFF fuel performance simulations using the BISON fuel performance code and discusses the support provided by simulation to PIE efforts. Progress in temperature, profilometry, fission gas release, plenum pressure, and zirconium redistribution simulation results have been demonstrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Holistic Measurement Driven Resilience: Combining Operational Fault and Failure Measurements and Fault Injection for Quantifying Fault Detection, Propagation and Impact. Final report

For HPC systems to date, application resilience to faults and failures has been accomplished by the brute- force method of checkpoint/restart, which allows an application to make forward progress in the face of system and application faults, errors, and failures independent of root cause or end result. It has remained the primary resilience mechanism because we lack a way to identify faults and anticipate consequences early enough to take meaningful mitigating action. However, checkpoint/restart implementations put a tremendous burden on system resources and on the applications themselves and is becoming less feasible at scale. Because we have not yet operated at scales at which checkpoint/restart fails to provide forward progress, despite increasing costs, vendors have had little motivation to provide the instrumentation necessary for early identification of faults and failures. However, as we move from petascale to exascale, component mean time to failure (MTTF) will render the existing techniques ineffectual and/or too expensive. Furthermore, fault recovery mechanisms such as failover and/or error correction introduce performance inconsistency. Instrumentation allowing early indication of problems and tools to enable use of such information by systems, operating systems, and applications offer an alternative, more scalable and less costly solution. In the HMDR project, we built on our experience and expertise developed and accumulated over years of research on design, monitoring, measurement, and assessment of resilient computing systems. Analysis of field data on the current and past generations of extreme-scale systems revealed several challenges that, if not addressed in increasingly larger and more complex systems, may hinder the effectiveness of future exascale computing systems. Specifically, i) file systems and interconnects in current-generation large-scale systems already operate at the margins of resiliency, including consistent performance, and may not scale to larger deployments; ii) automated, software-based failover mechanisms are frequently inadequate and can introduce wider failures, such that failures during recovery may lead to system/application failures, including system-wide outages; and iii) silent data corruption represents a critical fault mode and will require efficient detection mechanisms if next-generation applications are to take full advantage of exascale hardware. To address the above challenges, we assembled a team of world-renowned experts in resilient extreme- scale computing from the University of Illinois (Electrical and Computer Engineering, Computer Science, and NCSA), SNL, LANL, NERSC, and Cray. Our team includes representatives from centers that house many of the largest HPC resources in the world, both today and over the coming years. The team has a unique track record of research in i) system and application failure characterization based on the analysis of field data, ii) data-driven design of fault/error detection mechanisms, and iii) experimental characterization of system/application resiliency. The team includes system owners/operators who provide continuous data collection and access and ensure installation of appropriate analysis tools.

97 MATHEMATICS AND COMPUTING↗

Long-Term Failure Patterns and Survival in a Randomized Dose-Escalation Trial for Prostate Cancer. Who Dies of Disease?

Purpose: To report long-term failure patterns and survival in a randomized radiotherapy dose escalation trial for prostate cancer. Materials and Methods: A total of 301 patients with Stage T1b-T3 prostate cancer treated to 70 Gy versus 78 Gy now have a median follow-up of 9 years. Failure patterns and survival were compared between dose levels. The cumulative incidence of death from prostate cancer versus other causes was examined and regression analysis was used to establish predictive factors. Results: Patients with pretreatment prostate-specific antigen (PSA) >10 ng/mL or high-risk disease had higher biochemical and clinical failures rates when treated to 70 Gy. These patients also had a significantly higher risk of dying of prostate cancer. Patients <70 years old at treatment died of prostate cancer nearly three times more frequently than of other causes when they were radiated to 70 Gy, whereas those treated to 78 Gy died of other causes more frequently. Patients age 70 or older treated to 70 Gy died of prostate cancer as often as other causes, and those receiving 78 Gy never died of prostate cancer within 10 years of follow-up. In regression analysis, factors predicting for death from prostate cancer were pretreatment PSA >10.5 ng/mL, Gleason score 9 and 10, recurrence within 2.6 years of radiation, and doubling time of <3.6 months at the time of recurrence. Conclusions: Moderate dose escalation (78 Gy) decreases biochemical and clinical failure as well as prostate cancer death in patients with pretreatment PSA >10 ng/mL or high-risk disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

'Systemic Failures' and 'Human Error' in Canadian TSB Aviation Reports Between 1996 and 2002

This paper describes the results of an independent analysis of the primary and contributory causes of aviation accidents in Canada between 1996 and 2003. The purpose of the study was to assess the comparative frequency of a range of causal factors in the reporting of these adverse events. Our results suggest that the majority of these high consequence accidents were attributed to human error. A large number of reports also mentioned wider systemic issues, including the managerial and regulatory context of aviation operations. These issues are more likely to appear as contributory rather than primary causes in this set of accident reports.

Holloway, C. M.↗

A Case Study of the Failure on Apollo 13: Based on TMX-65270, Report of Apollo 13 Review Board

The dramatic journey of the crippled Apollo 13 vehicle has been heavily documented and popularized. Many people know there was an explosion in the service module which caused the vehicle to lose its oxygen supply. Less well known is the set of circumstances which led to the explosion. This paper examines the manufacturing, processing and testing history of oxygen tank #2, detailing the additive effects which caused the oxygen to ignite and to overpressure the tank.

Anderson, Brenda Lindley↗

Model for redundant-sensor signal errors

Report describes application of order statistics to analysis of failure modes in redundant systems. Report provides detailed mathematical discussion of approach, accompanied by graphs and equations. Techniques are relevant to process that demand high reliability, such as manufacture of dangerous chemicals. It also includes discussion of quad-redundant system.

Sowada, D. J.↗

Efficient Probability of Failure Calculations for QMU using Computational Geometry (LDRD 13-0144 Final Report)

This SAND report summarizes our work on the Sandia National Laboratory LDRD project titled "Efficient Probability of Failure Calculations for QMU using Computational Geometry" which was project #165617 and proposal #13-0144. This report merely summarizes our work. Those interested in the technical details are encouraged to read the full published results, and contact the report authors for the status of the software and follow-on projects.

97 MATHEMATICS AND COMPUTING↗

RI 1170 advanced strapdown gyro

The major components of the RI 1170 gyroscope are described. A detailed functional description of the electronics including block diagrams and photographs of output waveshapes within the loop electronics are presented. An electronic data flow diagram is included. Those gyro subassemblies that were originally planned and subsequently changed or modified for one reason or another are discussed in detail. Variations to the original design included the capacitive pickoffs, torquer flexleads, magnetic suspension, gas bearings, electronic design, and packaging. The selection of components and changes from the original design and components selected are discussed. Device failures experienced throughout the program are reported and design corrections to eliminate the failure modes are noted. Major design deficiencies such as those of the MSE electronics are described in detail. Modifications made to the gas bearing parts and design improvements to the wheel are noted. Changes to the gas bearing prints are included as well as a mathematical analysis of the 1170 gas bearing wheel by computer analysis. The mean free-path effects on gas bearing performance is summarized.

Source record↗

Measurement and Analysis of Failures in Computer Systems

This thesis presents a study of software failures spanning several different releases of Tandem's NonStop-UX operating system running on Tandem Integrity S2(TMR) systems. NonStop-UX is based on UNIX System V and is fully compliant with industry standards, such as the X/Open Portability Guide, the IEEE POSIX standards, and the System V Interface Definition (SVID) extensions. In addition to providing a general UNIX interface to the hardware, the operating system has built-in recovery mechanisms and audit routines that check the consistency of the kernel data structures. The analysis is based on data on software failures and repairs collected from Tandem's product report (TPR) logs for a period exceeding three years. A TPR log is created when a customer or an internal developer observes a failure in a Tandem Integrity system. This study concentrates primarily on those TPRs that report a UNIX panic that subsequently crashes the system. Approximately 200 of the TPRs fall into this category. Approximately 50% of the failures reported are from field systems, and the rest are from the testing and development sites. It has been observed by Tandem developers that fewer cases are encountered from the field than from the test centers. Thus, the data selection mechanism has introduced a slight skew.

Thakur, Anshuman↗