Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “endurance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

313 records · Page 18

Refining the Approach to Process Flowsheet Development and Maturation at Hanford - 20049

Rigorous process flowsheet management strategies form the basis of an enduring approach to refining the River Protection Project Integrated Process Flowsheet. Incorporation of lessons learned, recognizing upstream and downstream impacts and understanding barriers to implementation of process flowsheets from the outset of the decision-making process will help future revisions to the River Protection Project Integrated Process Flowsheet be more robust, technically defensible, cost effective, and time efficient, ultimately leading to an improved environmental stewardship of the Hanford site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An open-source hybrid unstructured mesh - CAD fusion multiphysics analysis workflow in SALAMANDER

Plasma facing components in fusion devices will endure extreme neutron and heat fluxes. To facilitate their design using simulation tools, the open-source Fusion Module, Fusion ENergy Integrated multiphys-X (FENIX) framework is being developed to model these components with a high-fidelity multi-physics multi-dimensional approach. It can iteratively resolve couplings between all the physics at play, from neutron radiation, to thermomechanics, to near-wall plasma dynamics. This framework is based on the Multiphysics Object Oriented Simulation Environment (MOOSE), which is developed by a collaboration of US National Laboratories since 2008, for advanced nuclear, geomechanics simulations and other applications. FENIX couples numerous simulation tools, including OpenMC, the Tritium Migration Analysis Program v8, the NekRS CFD software, and most MOOSE modules. For the coupling of radiation transport and other physics, FENIX supports a hybrid workflow between Computer Assisted Design (CAD) and unstructured mesh geometries. The CAD can be generated from skinning the unstructured mesh, to enable a coarse geometry for efficient particle transport, but still resolving the local material compositions and temperature gradients. Neutron transport is performed using DAGMC on the CAD, and Cardinal, integrated in FENIX, maps tallied quantities, such as the heat deposition or the tritium generation rates, from a tally volumetric mesh to the other physics’ unstructured mesh. This coupling was exercised on a simplified tokamak geometry, coupling neutron transport with the heat conduction equation, and on a monoblock divertor problem, coupling additionally with tritium migration. Mesh convergence studies highlight the importance of the mapping conservativeness. Coupling with thermo-mechanics is further enabled by the generalization of the approach to moving meshes. The presentation will include these coupled analysis as well as an update on status of the FENIX framework.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems

Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.

Avadhanula, Vamshi Krishna [Echogen Power Systems ↗

Effects of oxidant gas for atomic layer deposition on crystal structure and fatigue of ferroelectric Hf x Zr 1-x O 2 thin films

TiN/Hf x Zr 1-x O 2 (HZO)/TiN capacitors were prepared using two types of HZO films fabricated by atomic layer deposition using H 2 O or O 2 plasma as an oxidant gas, and post-deposition annealing at 400 °C was performed before the TiN top-electrode fabrication. The ferroelectric orthorhombic phase was dominantly formed for the O 2 plasma-based capacitor due to the strongly oxidizing source of O 2 plasma, resulted in higher remanent polarization (2P r = 20 µC/cm 2 ) than that (13 µC/cm 2 ) of the H 2 O-based capacitor. The fatigue properties for the O 2 plasma-based capacitor were improved by 14 % after 106 cycles compared to the H 2 O-based capacitor. This could be attributed to an oxygen-rich interface reaction layer (IRL) including TiO x between the HZO film and TiN bottom-electrode for the O 2 plasma-based capacitor. In conclusion, based on these results, superior 2P r and fatigue properties can be obtained using O 2 plasma-based HZO films.

36 MATERIALS SCIENCE↗

Impacts to FeRAM design arising from interfacial dielectric layers and wake up modulation in ferroelectric hafnium zirconium oxide

As ferroelectric hafnium zirconium oxide (HZO) becomes more widely utilized in ferroelectric microelectronics, integration impacts of intentional and non-intentional dielectric interfaces and their effects upon the ferroelectric film wake up and circuit parameters become important to understand. In this work, the effect of the addition of a linear dielectric aluminum oxide, Al 2 O 3 , below a ferroelectric Hf 0.58 Zr 0.42 O 2 film in a capacitor structure for FeRAM applications with NbN electrodes was measured. Depolarization fields resulting from the linear dielectric is observed to induce a reduction of the remanent polarization of the ferroelectric. Addition of the aluminum oxide also impacts the wake up of the HZO with respect to the cycling voltage applied. Intricately linked to the design of a FeRAM 1C/1T cell, the metal-ferroelectric-insulator-metal (MFIM) devices are observed to significantly shift charge related to the read states based on aluminum oxide thickness and wake up cycling voltage. As a result, a 33% reduction in the separation of read states is measured, which complicates how a memory cell is designed and illustrates the importance of clean interfaces in devices.

30 DIRECT ENERGY CONVERSION↗

Pushing the limits of NAND technology scaling with ferroelectrics

Artificial intelligence (AI) continues to drive transformative advancements across various industries. The data-intensive nature of AI training (and inferencing) has resulted in the generation of unprecedented volumes of data with machine-generated content surpassing human-generated data by more than 100-fold in 2025. Efficiently managing this data influx necessitates advanced digital storage technologies. However, traditional NAND flash memory, which is critical for supporting data flows in AI systems—alongside high-bandwidth memory, for AI training—faces fundamental scaling limitations as it approaches the 1000-layer milestone, encompassing more than 40 trillion transistors. This article delves into the potential of hafnia-based ferroelectric materials as a breakthrough solution to these challenges. Recent advancements indicate that the intrinsic limitations of ferroelectric field-effect transistors (FEFETs) can be mitigated through material and device-level engineering. These advancements enable FEFETs to meet the stringent density, reliability, and scalability requirements of future three-dimensional NAND technology. The role of ferroelectrics in addressing NAND scaling challenges and expanding storage capabilities presents a promising avenue for meeting the storage demands of the AI-driven era.

3D NAND↗