Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enclosure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Hand-held, mechanically cooled, radiation detection system for gamma-ray spectroscopy

In one embodiment, a radiation detection system is provided including a radiation detector and a first enclosure encapsulating the radiation detector, the first enclosure including a low-emissivity infra-red (IR) reflective coating used to thermally isolate the radiation detector. Additionally, a second enclosure encapsulating the first enclosure is included, the first enclosure being suspension mounted to the second enclosure. Further, a cooler capable of cooling the radiation detector is included. Still yet, a first cooling interface positioned on the second enclosure is included for coupling the cooler and the first enclosure. Furthermore, a second cooling interface positioned on the second enclosure and capable of coupling the first enclosure to a cooler separate from the radiation detection system is included. Other embodiments are also presented.

36 MATERIALS SCIENCE↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear diffusion into a Faraday cage.

Linear lightning diffusion into a Faraday cage is studied. An early-time integral valid for large ratios of enclosure size to enclosure thickness and small relative permeability ({mu}/{mu}{sub 0} {le} 10) is used for this study. Existing solutions for nearby lightning impulse responses of electrically thick-wall enclosures are refined and extended to calculate the nearby lightning magnetic field (H) and time-derivative magnetic field (HDOT) inside enclosures of varying thickness caused by a decaying exponential excitation. For a direct strike scenario, the early-time integral for a worst-case line source outside the enclosure caused by an impulse is simplified and numerically integrated to give the interior H and HDOT at the location closest to the source as well as a function of distance from the source. H and HDOT enclosure response functions for decaying exponentials are considered for an enclosure wall of any thickness. Simple formulas are derived to provide a description of enclosure interior H and HDOT as well. Direct strike voltage and current bounds for a single-turn optimally-coupled loop for all three waveforms are also given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shielded multi-stage EMI noise filter

Electromagnetic interference (EMI) noise filter embodiments and methods for filtering are provided herein. EMI noise filters include multiple signal exclusion enclosures. The multiple signal exclusion enclosures contain filter circuit stages. The signal exclusion enclosures can attenuate noise generated external to the enclosures and/or isolate noise currents generated by the corresponding filter circuits within the enclosures. In certain embodiments, an output of one filter circuit stage is connected to an input of the next filter circuit stage. The multiple signal exclusion enclosures can be chambers formed using conductive partitions to divide an outer signal exclusion enclosure. EMI noise filters can also include mechanisms to maintain the components of the filter circuit stages at a consistent temperature. For example, a metal base plate can distribute heat among filter components, and an insulating material can be positioned inside signal exclusion enclosures.

42 ENGINEERING↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An emergency response mobile robot for operations in combustible atmospheres

A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

Stone, Henry W.↗

Emergency response mobile robot for operations in combustible atmospheres

A mobile, self-powered, self-contained, and remote-controlled robot is presented. The robot is capable of safely operating in a combustible atmosphere and providing information about the atmosphere to the operator. The robot includes non-sparking and non-arcing electro-mechanical and electronic components designed to prevent the robot from igniting the combustible atmosphere. The robot also includes positively pressurized enclosures that house the electromechanical and electronic components of the robot and prevent intrusion of the combustible atmosphere into the enclosures. The enclosures are interconnected such that a pressurized gas injected into any one of the enclosures is routed to all the other enclosures through the interconnections. It is preferred that one or more sealed internal channels through structures intervening between the enclosures be employed. Pressure transducers for detecting if the pressure within the enclosures falls below a predetermined level are included. The robot also has a sensing device for determining the types of combustible substances in the surrounding atmosphere, as well as the concentrations of each type of substance relative to a pre-determined lower explosive limit (LEL). In addition, the sensing device can determine the percent level of oxygen present in the surrounding atmosphere.

Stone, Henry W.↗

Integrated optical biosensor system (IOBS)

An optical biosensor has a first enclosure with a pathogen recognition surface, including a planar optical waveguide and grating located in the first enclosure. An aperture is in the first enclosure for insertion of sample to be investigated to a position in close proximity to the pathogen recognition surface. A laser in the first enclosure includes means for aligning and means for modulating the laser, the laser having its light output directed toward said grating. Detection means are located in the first enclosure and in optical communication with the pathogen recognition surface for detecting pathogens after interrogation by the laser light and outputting the detection. Electronic means is located in the first enclosure and receives the detection for processing the detection and outputting information on the detection, and an electrical power supply is located in the first enclosure for supplying power to the laser, the detection means and the electronic means.

47 OTHER INSTRUMENTATION↗

New Accessory for Cleaning the Inside of the Machine Tool Cavity

The best way to extend the life of a metalworking fluid (MWF) is to make sure the machine tool and MWF delivery system are properly cleaned at least once per year. The dilemma the MWF manager is faced with is: How does one clean the machine tool and the MWF system on a large machine tool with an enclosure in a timely manner without impacting production schedules? Remember the walls and roof of the machine enclosure are coated with a film of dried contaminated MWF that must also be removed. If not removed, the deposits on these surfaces can recontaminate the fresh charge of MWF. I have found a product that with this revised procedure helps to shorten the machine tool down time involved with machine cleaning. (1) Discuss with your MWF supplier if they have a machine cleaning product that can be used with your current water based MWF during normal machining operations. Most MWF manufacturers have a machine cleaner that can be used at a lower concentration (1-2% vs. 5%) and can be used while still making production parts for a short period of time (usually 24-48 hours). (2) Make sure this machine cleaner is compatible with the work-piece material you are machining into product. Most cleaners are compatible with ferrous alloys. Because of the increased alkalinity of the fluid you might experience staining if you are machining copper or aluminum alloys. (3) Remove the chips from the chips pans and fluid channels. (4) During off shift hours circulate the MWF using a new product marketed by Rego-Fix called a 'Hydroball'. This device has a 5/8 inch diameter straight shank which allows it to be installed in any collet or solid quick change tool holder. It has multiple nozzles so that the user can control the spray pattern generated when the MWF is circulated. It allows the user to utilize the high pressure, through spindle MWF delivery capability of your machine tool for cleaning purposes. The high pressure MWF system can now be effectively used for cleaning purposes. This will also work with standard pressure system but you must reduce the number of nozzles utilized. By combining the movement of the machine axis around the operating envelope and the MWF circulation you can do a reasonably effective job of washing the inside of the machine tool operating cavity. Way covers will be moved and surfaces exposed because of axis movement. Spray direction will change to better wash fixtures and machine tool components. Deposits will start to breakdown and be washed into the machine tool sump. Since the cycle will run four or more hours it can be done with a weaker cleaning solution. The distributor states that the unit can be rotated up to 50 RPM. When running it has the same effect as the washing rotor inside of your home dishwasher. Inside the cavity on a machining center there is a lot of splash. During normal operations, MWF deposits buildup on the walls and roof of the enclosures. If these deposits (containing bacteria, mold and other contaminants) are not removed they will inoculate the fresh charge of MWF when they are resaturated. When you clean the inside of machine tool cavity, time is spent removing these deposits on the walls and roof of the enclosure. Getting to these surfaces is very difficult usually requiring that a member of the cleaning crew get inside the machine tool to reach them. The Hydro ball is effective in distributing the cleaning solution on all surfaces of the enclosure under high pressure. The only negative we have found is you get to find all the gaps and leaks in your machine tool enclosure. By running the hydro ball with the machine cleaner enriched MWF during off shift (4-8 hours) you can effectively remove these deposits and buildups on the internal surfaces of the cavity of the machine tool and wash them down into the sump. You also clean the internal components of the MWF system without interrupting normal scheduled work. (5) Pump out the spent MWF. You will have found that most of the deposits have been washed from the internal surfaces of the enclosure. For extremely dirty machines you might have to refill the machine tool with the normal machine cleaner mix. You will find that even heavy deposits will break down quicker because of this pre-wash cycle. (6) Rinse the machine cavity. (7) Clean the walls, bottom and screens in the MWF reservoir. The use of this tool and the dilute machine cleaner reduced the cleaning time considerately without affecting production schedules. (8) Refill with MWF and resume normal operations. What we like about this system is we can schedule these light cleanings just before a scheduled fluid change. Add the cleaner to the mix and run the Hydroball on second shift. The spent fluid is pumped out on third shift and the machine refilled. The machine tool with a fresh charge of MWF is ready for first shift without interrupting production schedules. We get better life from our MWFs and the machinists are happier about the condition of their machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gopherus Agassizii (Desert Tortoise). Predation/Mountain Lions (Pre-Print)

During a long-term study on tortoise growth within 3 fenced 9-ha enclosures in Rock Valley, Nevada Test Site (NTS), Nye County, Nevada, USA, tortoises have been captured annually since 1964 (Medica et al. 1975. Copeia 1975:630-643; Turner et al. 1987. Copeia 1987:974-979). Between early August and mid October 2003 we observed a significant mortality event. The Rock Valley enclosures were constructed of 6 x 6 mm mesh 1.2 m wide hardware cloth, buried 0.3 m in the soil with deflective flashing on both sides on the top to restrict the movement of small mammals and lizards from entering or leaving the enclosures (Rundel and Gibson 1996, Ecological communities and process in a Mojave Desert ecosystem: Rock Valley, Nevada, Cambridge University Press, Great Britain. 369 pp.). On August 6, 2003, the carcass of an adult female Desert Tortoise No.1411 (carapace length 234 mm when alive) was collected while adult male tortoise No.4414 (carapace length 269 mm) was observed alive and in good health on the same day. Subsequently the carcass of No.4414 was found on October 16, 2003. Between October 16-17, 2003, the remains of 6 (5 adult and 1 juvenile) Desert Tortoises were found, some within each of the 3 enclosures in Rock Valley. A seventh adult tortoise was found on September 26, 2006, its death also attributed to the 2003 mortality event based upon the forensic evidence. Each of the 7 adult Desert Tortoises had the central portion of their carapace broken open approximately to the dorsal portion of the marginal scutes while the plastron was still intact (Figure 1A). Adjacent to 7 of the 8 remains we located numerous bone fragments including parts of the carapace and limbs as well as dried intestines in a nearby Range Rhatany (Krameria parvifolia) shrub. The significance of the frequent use of this shrub is puzzling. Three of the Desert Tortoise shell remains possessed distinctive intercanine punctures measuring 55-60 mm center to center indicating that this was an adult sized Mountain Lion. By comparison, a 2 year old male Mountain Lion salvaged on NTS had an upper intercanine bite width of 45 mm, and a 6 month old kitten measured 35mm respectively. The Mountain Lion (Puma concolor) is the only predator that exists in southern Nevada that could possibly have a bite with a gap between its upper canine teeth that large (Murmann et al. 2006. J. Forensic Sci. 51:846-860). The appearance of the shell remains in Figure 1A is similar to that depicting Jaguar (Panthera onca) predation, on the Amazonian Tortoise (Geochelone denticulata) as illustrated by Emmons (1989. J. Herpetol. 23:311-314) with the majority of the carapace broken open and the plastron still intact. Predation of Desert Tortoises by Mountain Lions was also documented in 1993 in southern Arizona (Little Shipp Wash Plot), where 7 of 8 carcasses found were attributed to Mountain Lion predation (Averill-Murray et al. 2002. In. T.R.Van Devender [ed.], The Sonoran Desert Tortoise: Natural History, Biology, and Conservation, pp.109-134. University of Arizona Press and Arizona-Sonora Desert Museum, Tucson, Arizona). Similarly, predation by a Mountain Lion has been reported on the Argentine Tortoise (Chelonoidis chilensis) in Argentina (Acosta et al. 2004. Herpetol. Review 35:53-54), and a Mountain Lion kitten was observed to kill and consume a portion of the carapace of a Texas Tortoise (Gopherus berlandieri) in west Texas (Adams et al. 2006. Southwestern Nat. 51:581-581). Over the past 45 years this Desert Tortoise population has been monitored yearly, with no prior evidence of predation to tortoises within the fenced enclosures. On several occasions other predators such as Bobcats (Lynx rufus) have been observed within the study enclosures for as long as a week. Evidence of Kit Fox (Vulpes macrotus) sign has been observed on numerous occasions, and a Spotted Skunk (Spilogale putorius) and Longtail Weasels (Mustela frenata) have been captured and released (B.G. Maza, pers. comm.; Medica 1990. Great Basin Nat. 50:83-84), while Coyotes (Canis latrans) were never observed within the fenced enclosures. Prior to this predation event in Rock Valley, 17 Desert Tortoises were alive between 2000 and 2002, only 7 were known to be alive in 2004, while 2 tortoises have not been seen since 2002. Predation studies of Mountain Lions indicate that these events may be an example of a learned behavior of individual animals developing a preference for a prey (Logan and Sweanor 2001, Desert Puma: Evolutionary ecology and conservation of an enduring carnivore. Hornocker Wildlife Institute, Island Press, Washington. 463 pp.; Creeden and Graham 1997, Desert Bighorn Council Transactions. p. 37-43), or the plight of a large predator locating an available source of food while passing through low elevation Mojave Desert habitat in late summer or early fall.

54 ENVIRONMENTAL SCIENCES↗

Ambient Air Sampling During Quantum-dot Spray Deposition

Ambient air sampling for nano-size particle emissions was performed during spot spray coating operations with a Sono-Tek Exactacoat Benchtop system (ECB). The ECB consisted of the application equipment contained within an exhaust enclosure. The enclosure contained numerous small access openings, including an exhaust hook-up. Door access comprised most of the width and height of the front. The door itself was of the swing-out type. Two types of nanomaterials, Cadmium selenide (Cd-Se) quantum-dots (QDs) and Gold (Au) QDs, nominally 3.3 and 5 nm in diameter respectively, were applied during the evaluation. Median spray drop size was in the 20 to 60 micrometer size range.1 Surface coating tests were of short duration, on the order of one-half second per spray and ten spray applications between door openings. The enclosure was ventilated by connection to a high efficiency particulate aerosol (HEPA) filtered house exhaust system. The exhaust rate was nominally 80 ft3 per minute producing about 5 air changes per minute. Real time air monitoring with a scanning mobility particle size analyzer (SMPS ) with a size detection limit of 7 nm indicated a significant increase in the ambient air concentration upon early door opening. A handheld condensation particle counter (CPC) with a lower size limit of 10 nm did not record changes in the ambient background. This increase in the ambient was not observed when door opening was delayed for 2 minutes (~10 air changes). The ventilated enclosure controlled emissions except for cases of rapid door opening before the overspray could be removed by the exhaust. A time delay sufficient to provide 10 enclosure air changes (a concentration reduction of more than 99.99 %) before door opening prevented the release of aerosol particles in any size.2 Scanning-transmission electron microscopy (STEM) and atomic force microscopy (AFM) demonstrated the presence of agglomerates in the surfaces of the spray applied deposition. A filtered air sample of the enclosure overspray examined by AFM also demonstrated the presence of agglomerates for the Au QDs. The AFM system was not able to resolve individual QDs as was the STEM. Chemical fingerprinting of the QDs with STEM/EDS (energy dispersive spectroscopy) was performed for the Cd-Se surface deposition, but not the aerosol. Both STEM and AFM background characterization by morphology and chemical fingerprinting were performed throughout the laboratory for a period of about one year. Outdoor sources were primarily biological, combustion fume, salt and other crustal particles. Indoor sources were primarily paper/clothing fibers, spray-on insulation fragments, fiber glass, and human skin cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fire Whirl Investigation

A series of experiments were performed with the objective of achieving an extreme thermal environment by creating a fire whirl in an enclosure in facilities at the Thermal Test Complex (TTC) at Sandia National Laboratories. The motivation for the experiments is based on results from previous experiments performed at Sandia in an igloo representing a mock weapon's storage facility. In that test series, a fire whirl developed within the igloo resulting in extremely high heat flux levels. This environment was created with a pool fire of 4.6-m in diameter and was not under controlled, repeatable conditions. The objective of the current tests is to have the ability to create this environment in a repeatable controlled environment at a smaller scale, namely with a pool fire not above 3-m diameter effectively, thereby allowing for repeatable, cost-effective testing. In FY15, six tests were conducted in the Crosswind Test Facility (XTF), using a 1.77 m square pan. In FY16, three tests were conducted in the Fire Laboratory for Accreditation of Modeling by Experiment (FLAME) using a 3-m diameter pan. Both of these test series utilized the same enclosure. In FY17, a single test was performed in XTF using a 2.7 m square pan using a modified enclosure which included a ceiling. All tests used Jet-A as the fuel. The wind speed and gap width of the enclosure were varied for the FY15 XTF tests and the gap width and effect of insulation on the enclosure walls were varied for the FY16 FLAME tests. Fuel regression rates, heat flux, and gas velocity measurements were obtained. The results from the FY15 and FY16 test series indicate that fuel regression rates and peak heat flux levels are a factor of two higher than non-fire whirl pool fires of equivalent diameter. The results from the FY17 test using an enclosure with a ceiling met the objective of the test series by achieving temperatures of nearly 1400°C and heat flux levels of 400 kW/m 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Moderation Module for High-Temperature Micro-Reactor Applications

Development and deployment of micro-reactors that provide competitive efficiency, prevailing compactness, and inherent safety is an immediate focus of the U.S. nuclear industry. For thermal neutron micro-reactors operating at elevated temperature for optimized efficiency, such as micro molten-salt reactors (MSRs), heat-pipe reactors, and very-high temperature reactors (VHTRs), high-performance moderator based on metal hydride can enhance the neutron economy and therefore achieve reduced weight and enhanced portability. As unclad metal hydride inevitably decomposes at elevated temperature, an enclosure is required for hydride moderator to deliver desired performance at elevated temperatures. Conventional moderator enclosure solutions based on high-temperature alloys introduce extraneous neutron penalty into the micro-reactor, affecting the neutronic benefits provided by the hydride moderator. Additionally, the compatibility between the high-temperature alloy enclosure and the micro-reactor matrix is also a potential issue. In this report, we disclose an Advanced Moderator Module (AMM) concept enabled by an innovative enclosure solution combining the advantages of refractory metals, ceramic matrix composites (CMCs), and advanced coating technology to serve as hydrogen permeation barrier up to very-high temperatures. A schematic description of the AMM structure is illustrated in Figure A1. The AMM contains a moderating material core made of metal hydride with high thermal stability, such as YH 2-x . The hydride core is enclosed by an H 2 barrier layer coated on a ductile refractory metal liner to minimize hydrogen loss during high-temperature operation. A ceramic matrix composite (CMC) cladding is adopted to provide further structural strength, especially during power transients. Between the CMC cladding and metal liner, an extra diffusion barrier coating is inserted to suppress the chemical interaction at elevated temperatures. Hence, based on a series of innovative material solutions, the AMM is capable of containing the metal hydride core at elevated temperature (>900oC) inside coated and lined CMC envelop with negligible hydrogen loss throughout the microreactor lifetime. The benefit of the AMM technology was assessed based on a comprehensive multi-stage reactor-physics analysis. Advanced moderation based on hydride metals (such as YH2-x) enables reaching optimum moderation with higher fuel content than traditional VHTR technology, which is required to design compact micro-reactor cores targeting long-life operation. The AMM enclosure technology provides lower thermal neutron absorption rates than traditional solutions (based on stainless steel or Mo-based alloy such as TZM), which reduces the fissile enrichment requirements by 6-8% on a TRISO-fueled design based on the EMPIRE core. Finally, combining the hydride moderator with neutron transparent enclosure solutions provides significant potential to boost neutronics performance of micro-reactors in terms of increased core lifetime or reduced size and weight by 30-50% on a micro-reactor based on the Holos Quad technology. The progress and plans for on-going development and demonstration efforts are also discussed in this report. The current demonstration of AMM is focused on the hydrogen diffusion barrier demonstration under thermal cycling, while radiation tolerance demonstration is planned. The next step of the demonstration plan will be the assembly of miniature AMM for high-temperature testing, which can be used as a prototype for future pilot scale demonstration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Drop Analysis of the Advanced Test Reactor Fresh Fuel Shipping Container with Heavier Low-Enriched Uranium Fuel Contents

The Advanced Test Reactor Fresh Fuel Shipping Container (ATR FFSC) is a rectangular stainless steel container used for shipping radioactive material. The container is described in the ATR FFSC Safety Analysis Report (SAR). Per the ATR FFSC SAR, the ATR FFSC is designated a Type AF-96 packaging per the definition of 10 CFR §71.4, and was originally designed to transport high enriched uranium (HEU) reactor fuel elements for the Advanced Test Reactor (ATR), the Advanced Test Reactor Critical (ATRC) facility, the Massachusetts Institute of Technology Reactor (MITR), and the University of Missouri Research Reactor (MURR). The Department of Energy, National Nuclear Security Administration’s (NNSA), Office of Material Management and Minimization (M3) is working with the Idaho National Laboratory (INL) to develop and qualify new low enriched uranium (LEU) fuels and technologies for use in the ATR, ATRC, MITR, and MURR reactors. The LEU fuel elements will weigh significantly more than the current HEU designs and, combined with their associated Fuel Handling Enclosures for packaging, some configurations will exceed the 50 lbf used in the ATR FFSC qualifying drop tests. There are LEU versions of MITR, MURR, and ATR fuel elements. However, for this evaluation, drop analysis of the ATR FFSC with only the heavier ATR Low Enrichment (LOWE) fuel element is considered in this evaluation because the LOWE fuel element is the heaviest of the considered LEU fuel elements. The ATR HEU fuel element and the ATR LOWE fuel element are identical in every design aspect except for the fuel meat inside the 19 fuel plates. The LEU fuel meats are made using a U-10Mo high-density foil rather than uranium dispersed in aluminum in the HEU fuel elements. The high density of the uranium in the LEU fuel meat increases the LOWE fuel element weight to just under 44 lbf (versus the 22.1 lbf weight of the tested ATR HEU fuel element). ATR fuel elements are placed in a thin-gauge aluminum weldment called a "Fuel Handling Enclosure" during packaging. The Fuel Handling Enclosure is used to cover and protect the element during loading and unloading operations. The ATR Fuel Handling Enclosure weighs about 15 lbf per the drawings in the ATR FFSC SAR and the weight is accounted for in this evaluation. Transporting the heavier LEU fuel elements require evaluation of two issues. The first is the effect of the increased mass of the LEU fuel elements on the survivability of the ATR FFSC package following the requisite drop qualifications. The second is the effect of the increased mass of the fuel plates on the fuel element during the same drops. The ATR FFSC containing an ATR HEU fuel element in an ATR Fuel Handling Enclosure was physically dropped multiple times to qualify the container as a Type AF-96 package. The ATR FFSC SAR describes the drop tests performed with an actual ATR HEU fuel element weighing 22.1 lbf contained in a 14.3 lbf Fuel Handling Enclosure for a total payload of 36.4 lbf. Those drop tests showed that the ATR FFSC maintained containment of the ATR HEU fuel element and the fuel element was not significantly damaged. (Containment herein is not defined as a leak tight but is retention of the radioactive contents.) The purpose of the evaluation is to analytically show that, for a similar set of tests, the ATR FFSC maintains containment of the heavier ATR LOWE fuel element and to assess the damage to the fuel element during the drops. The approach was to create finite element analysis (FEA) models that produce the same results as the physical drops. Those models were then used as the benchmarks for the follow-on analyses using the heavier contents. FEA models of the drops of ATR FFSC using up to a 115 lbf fuel element were run and evaluated. Likewise, drops of a LOWE fuel element weighing 44 lbf in the ATR FFSC were run and evaluated. It is important to note that this report was done at the quality level necessary to be included in a nuclear facility safety basis. However, it is not the intent of this report to conclude the suitability of the ATR FFSC for transporting the heavier payloads. This report only describes the results of the FEA as related to the required drop scenarios. Incorporation of the FEA into the safety basis will be evaluated by the ATR FFSC design authority. The physical drop tests of the HEU fuel element and FEA drop analysis for the LOWE fuel element showed noteworthy damage to the fuel plates. An aluminum protective block was conceived to mitigate the damage. The concept requires the blocks to be placed in the fuel element between the end boxes and fuel plates. Additional FEA drop analyses were performed using the protective block. The addition of the blocks is primarily intended to mitigate the damage to the LOWE fuel element fuel plates. However, FEA drop analyses of the ATR HEU fuel element with the blocks were also performed and included for information.

42 ENGINEERING↗

NASTRAN modeling and analysis of rigid and flexible walled acoustic cavities

The acoustic slot elements, CSLOTi, are applied to analyze two-dimensional enclosures with fixed or moving boundaries. The capability utilized to compute (a) the acoustic natural modes and frequencies of a rigid walled enclosure and (b) the sound pressure at any point inside an enclosure when the surrounding walls are forced to vibrate. Applications to an automobile passenger compartment illustrate the technique. The axisymmetric fluid elements, CFLUIDi, are used in conjunction with a suitable choice of symmetry planes and a model of the surrounding structure to approximate a two-dimensional enclosure with flexible walls. The enclosure walls are modeled using finite elements or structural modes. Illustrative examples include a comparison of rectangular cavity modes with those calculated using the acoustic slot element and the free vibration modes of two enclosures coupled through a flexible rectangular panel.

Wolf, J. A., Jr.↗

Totally confined explosive welding

The undesirable by-products of explosive welding are confined and the association noise is reduced by the use of a simple enclosure into which the explosive is placed and in which the explosion occurs. An infrangible enclosure is removably attached to one of the members to be bonded at the point directly opposite the bond area. An explosive is completely confined within the enclosure at a point in close proximity to the member to be bonded and a detonating means is attached to the explosive. The balance of the enclosure, not occupied by explosive, is filled with a shaped material which directs the explosive pressure toward the bond area. A detonator adaptor controls the expansion of the enclosure by the explosive force so that the enclosure at no point experiences a discontinuity in expansion which causes rupture. The use of the technique is practical in the restricted area of a space station.

Bement, L. J.↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗