Luminescence and Thermal Imaging Applied to Half-Cut-Cell and Emitter-Wrap-Through-Cell Modules
Imaging techniques provide spatial details and visualization of module defects and degradation mechanisms that affect energy conversion efficiency and performance. We apply photoluminescence, electroluminescence, and dark lock-in thermography imaging techniques to evaluate new modules in their initial state and after applying stresses of damp heat, light-induced-degradation regeneration parameters, thermal cycling, and humidity-freeze cycles. One module uses emitter-wrap-through cells with back contacts connected to a metal-foil backplane, and the other is composed of half-cut cells. Imaging shows examples on non-uniform degradation and damage such as cells that degrade and recover under the applied conditions, cells with cracks and handling damage, and cells with increasing series resistance.