Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High contrast cathode ray tube

A layer of material is described, which contains fine grains of phosphor material stimulated by electrons to produce visible radiation. The layer, which also contains fine grains of cobalt oxide, is deposited on the glass screen of a cathode ray tube to provide high contrast, by absorbing most of the visible radiation which is directed to the layer through the screen, while not materially affecting the visible light which the phosphor material produces in response to the electron stimulation.

Lisovicz, E. J.↗

State-Specific Kinetic Modeling for Predictions of Radiative Heating in H 2 /He Entry Flows

A 23-species State-to-State (StS) thermochemical model for H 2 /He mixtures is developed and used to simulate 1-D shocks at conditions relevant for ice and gas giant entry flows. To implement this StS model, a literature review of the state-specific excitation and ionization rates of atomic H is first performed. While electron impact rates from various sources are found to be in relatively good agreement, large discrepancies are found in the limited data available on heavy particle impact rates. To investigate the impact of these discrepancies on the predicted shock and radiance profiles, simulations are performed for three different versions of the kinetic model, each with a different set of heavy particle impact rates from the literature. Of these three models, two are found to over-predict and one is found to under-predict the radiance values seen in corresponding experimental data from the NASA Ames Electric Arc Shock Tube (EAST) facility. A sensitivity analysis to the electron and heavy particle impact rates is then performed, from which an improved kinetic model with modified rates is proposed. This modified kinetic model is found to reproduce the total integrated radiance seen in the EAST experiments accurately. This suggests that the associated radiative heating that would be encountered by an entry probe in these environments would be well predicted by this kinetic model. However, some discrepancies are still found i the relative contributions to the total radiance from different spectral features, suggesting that additional improvements to the kinetic model still need to be made.

Outer Planet↗

Novel Low-Cost, Low-Power Miniature Thermionic Cathode Developed for Microwave/Millimeter Wave Tube and Cathode Ray Tube Applications

A low cost, small size and mass, low heater power, durable high-performance barium dispenser thermionic cathode has been developed that offers significant advancements in the design, manufacture, and performance of the electron sources used in vacuum electronic devices--such as microwave (and millimeter wave) traveling-wave tubes (TWT's)--and in display devices such as high-brightness, high-resolution cathode ray tubes (CRT's). The lower cathode heater power and the reduced size and mass of the new cathode are expected to be especially beneficial in TWT's for deep space communications, where future missions are requiring smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. Also expected to benefit are TWT's for commercial and government communication satellites, for both low and geosynchronous Earth orbit, with additional benefits offered by lower cost and potentially higher cathode current loading. A particularly important TWT application is in the microwave power module (MPM), which is a hybrid microwave (or millimeter wave) amplifier consisting of a low-noise solid state driver, a vacuum power booster (small TWT), and an electronic power conditioner integrated into a single compact package. The attributes of compactness and potentially high electrical efficiency make the MPM very attractive for many commercial and government (civilian and defense) applications in communication and radar systems. The MPM is already finding application in defense electronic systems and is under development by NASA for deep space communications. However, for the MPM to become competitive and commercially successful, a major reduction in cost must be achieved.

Wintucky, Edwin G.↗

The Direct Digital Modulation of Traveling Wave Tubes

Traveling wave tube (TWT) technology, first described by Rudolf Kompfner in the early 1940s, has been a key component of space missions from the earliest communication satellites in the 1960s to the Cassini probe today. TWTs are essentially signal amplifiers that have the special capability of operating at microwave frequencies. The microwave frequency range, which spans from approximately 500 MHz to 300 GHz, is shared by many technologies including cellular phones, satellite television, space communication, and radar. TWT devices are superior in reliability, weight, and efficiency to solid-state amplifiers at the high power and frequency levels required for most space missions. TWTs have three main components -an electron gun, slow wave structure, and collector. The electron gun generates an electron beam that moves along the length of the tube axis, inside of the slow wave circuit. At the same time, the inputted signal is slowed by its travel through the coils of the helical slow wave circuit. The interaction of the electron beam and this slowed signal produces a transfer of kinetic energy to the signal, and in turn, amplification. At the end of its travel, the spent electron beam moves into the collector where its remaining energy is dissipated as heat or harnessed for reuse. TWTs can easily produce gains in the tens of decibels, numbers that are suitable for space missions. To date, however, TWTs have typically operated at fixed levels of gain. This gain is determined by various, unchanging, physical factors of the tube. Traditionally, to achieve varying gain, an input signal s amplitude has had to first be modulated by a separate device before being fed into the TWT. This is not always desirable, as significant distortion can occur in certain situations. My mentor, Mr. Dale Force, has proposed an innovative solution to this problem called direct digital modulation . The testing and implementation of this solution is the focus of my summer internship. The direct digital modulation of a TWT removes the need for a separate amplitude modulation device. Instead, different levels of gain are achieved by varying the electron beam current. The lower the current, the less kinetic energy is available to be transferred to the signal. To vary the current, a grid is placed in-between the electron gun and the slow wave circuit. By changing the voltage across the grid, the electron beam current can be controlled. Grid technology has mostly been used in pulse applications such as radar, where only two voltage states are necessary. For direct digital modulation, however, a continuous range of voltages is required.

Radhamohan, Ranjan S.↗

Electronic and Mechanical Properties of Hydrogen Functionalized Carbon Nanotubes

We examined the electronic and mechanical properties of hydrogen functionalized carbon nanotubes. The functionalization pattern covers two extreme groups. One group has randomly selected functionalization sites including one to twenty percent of the carbon atoms. The other group has regularly patterned functional sites parallel to the tube axis. Metallic, small-gap semiconducting and large-gap semiconducting carbon nanotubes are studied. The results reveal that the electronic properties of the tubes are very sensitive to the degree of functionalization, with even one percent functionalization being enough to render metallic tubes semiconducting. On the other hand, the mechanical properties, like tensile modulus, are much less sensitive to functionalization. For carbon nanotubes functionalized with specific patterns, the electric properties depends strongly on the nature of the functionalization pattern.

Yang, Liu↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Ion and electron angular distributions in the Io torus region of the Jovian magnetosphere

Angular distributions are presented of ion (about 0.5-2 MeV) and electron (greater than 10 MeV) fluxes measured during the Voyager 1 spacecraft passage through the inner regions of the Jovian magnetosphere. In the regions of peak flux intensities, just outside the orbit of Io, the ion angular distributions are most sharply peaked at 90 deg local pitch angle, a configuration consistent with diffusion of the particles inward from large radial distances. Inside the orbit of Io the lower-energy ions exhibit angular distributions depleted at 90 deg local pitch angles, suggesting the possibility of charge-exchange scattering loss of these particles. In the vicinity of the Io flux tube, no significant effect is observed in the flux or pitch angle distributions of the ions. The relativistic electrons are depleted in the flux tube region and exhibit an asymmetrical pitch angle distribution, with more electrons appearing to arrive from the equatorial region (the direction of Io) than from the low-altitude mirror point.

Lanzerotti, L. J.↗

Measurement and calculation of the Stark-broadening parameters for the resonance lines of singly ionized calcium and magnesium.

The electron-impact-broadened profiles of the resonance lines of singly ionized calcium and magnesium have been measured using an electromagnetically driven shock tube and a rapid-scanning Fabry-Perot spectrometer. For an electron density of 10 to the 17th power per cu cm and a temperature of 19,000 K, we found the Lorentzian half-width of the Ca+ line to be 0.086 A plus or minus 10% and of the Mg+ line to be 0.044 A plus or minus 10%. Using the quantum-mechanical theory of Barnes and Peach and our semiclassical calculation for the calcium lines, we found that the temperature dependence of the theoretical curves is close to that measured, although both theories predict actual values which are somewhat large.

Jones, W. W.↗

Carbon Nanotubes: Molecular Electronic Components

The carbon Nanotube junctions have recently emerged as excellent candidates for use as the building blocks in the formation of nanoscale molecular electronic networks. While the simple joint of two dissimilar tubes can be generated by the introduction of a pair of heptagon-pentagon defects in an otherwise perfect hexagonal graphene sheet, more complex joints require other mechanisms. In this work we explore structural characteristics of complex 3-point junctions of carbon nanotubes using a generalized tight-binding molecular-dynamics scheme. The study of pi-electron local densities of states (LDOS) of these junctions reveal many interesting features, most prominent among them being the defect-induced states in the gap.

Srivastava, Deepak↗

Low Temperature Regenerators for Zero Boil-Off Liquid Hydrogen Pulse Tube Cryocoolers

Recently, a great deal of attention has been focused on zero boil-off (ZBO) propellant storage as a means of minimizing the launch mass required for long-term exploration missions. A key component of ZBO systems is the cooler. Pulse tube coolers offer the advantage of zero moving mass at the cold head, and recent advances in lightweight, high efficiency cooler technology have paved the way for reliable liquid oxygen (LOx) temperature coolers to be developed which are suitable for flight ZBO systems. Liquid hydrogen (LH2) systems, however, are another matter. For ZBO liquid hydrogen systems, cooling powers of 1-5 watts are required at 20 K. The final development from tier for these coolers is to achieve high efficiency and reliability at lower operating temperatures. Most of the life-limiting issues of flight Stirling and pulse tube coolers are associated with contamination, drive mechanisms, and drive electronics. These problems are well in hand in the present generation coolers. The remaining efficiency and reliability issues reside with the low temperature regenerators. This paper will discuss advances to be made in regenerators for pulse tube LH2 ZBO coolers, present some historical background, and discuss recent progress in regenerator technology development using alloys of erbium.

Salerno, Louis J.↗

Jovian S-burst observations at 32 MHz

Drift rates for S-burst emissions from Jupiter are studied. The burst spectra, recorded in the frequency range near 32 MHz, provide a qualitative illustration of the behavior of electron bunches shortly after injection into the Io-associated magnetic flux tube. The morphology of the spectra may be taken as support for the hypothesis of an ionospheric acceleration mechanism influencing the flow of electrons.

Desch, M. D.↗

Accurate activity determination of a californium neutron source

Accurately counting analog events requires constructing an electronics chain that produces one count for each input pulse. Here, in this work, we review the use of Nuclear Instrumentation Module electronic units for counting neutron capture events in a 3He tube. We identify two unique types of false trigger events in a leading-edge discriminator and show how a dual timer module can be used to produce a veto window to exclude these events. We use the constructed electronics chain to build an apparatus to measure neutron pulses from a 252 Cf neutron source. We compare the measurements with a Monte Carlo N-Particle (MCNP) model to determine the activity of the neutron source. Furthermore, by making additional measurements with borated polyethylene attenuators between the source and detector, we are able to determine the boron concentration of the polyethylene. This technique provides accurate determination of the source activity to a precision of 2.8% at the k=1 level. The method used is simple, inexpensive, and requires no additional calibrated instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Conductance of Nanotubes Deformed by the AFM Tip

The conductance drop under AFM-tip deformation can be explained by stretching of the tube length. NT sensors can be built utilizing uniform stretching. Single sp3 bond cross section cannot block electrons, because another conducting path may exist. AFM tip which forms sp3 bonds with the tube will decrease conductance. In the "table experiment" a conductance drop of 2 orders of magnitude happened only after some bonds were broken.

Svizhenko, Alexei↗

Shock tube study of ionization rates of NaCl-contaminated argon

Spectrally resolved radiometry and a microwave technique were used to measure the electron density, electron temperature, and concentration, and the concentration of sodium atoms in the weakly ionized region behind a shock wave in an argon shock tube. It is shown that the observed increase in the ionization rate is due to electron detachment of negative chlorine ions produced from sodium chloride vapor contained as an impurity in the argon gas. The observed behavior of the electron temperature in time and the reactions controlled by the electron temperature are analyzed in the light of the impurity reaction scheme.

Scheneider, C.-P.↗

Simulation and flow physics of a shocked and reshocked high-energy-density mixing layer

This work describes a computational investigation of multimode instability growth and multimaterial mixing induced by multiple shock waves in a high-energy-density (HED) environment, where pressures exceed 1 Mbar. The simulations are based on a series of experiments performed at the National Ignition Facility (NIF) and designed as an HED analogue of non-HED shock-tube studies of the Richtmyer–Meshkov instability and turbulent mixing. A three-dimensional computational modelling framework is presented. It treats many complications absent from canonical non-HED shock-tube flows, including distinct ion and free-electron internal energies, non-ideal equations of state, radiation transport and plasma-state mass diffusivities, viscosities and thermal conductivities. The simulations are tuned to the available NIF data, and traditional statistical quantities of turbulence are analysed. Integrated measures of turbulent kinetic energy and enstrophy both increase by over an order of magnitude due to reshock. Large contributions to enstrophy production during reshock are seen from both the baroclinic source and enstrophy–dilatation terms, highlighting the significance of fluid compressibility in the HED regime. Dimensional analysis reveals that Reynolds numbers and diffusive Péclet numbers in the HED flow are similar to those in a canonical non-HED analogue, but conductive Péclet numbers are much smaller in the HED flow due to efficient thermal conduction by free electrons. It is shown that the mechanism of electron thermal conduction significantly softens local spanwise gradients of both temperature and density, which causes a minor but non-negligible decrease in enstrophy production and small-scale mixing relative to a flow without this mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗