Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Design of a graphical user interface for few-shot machine learning classification of electron microscopy data

The recent growth in data generation by modern electron microscopes requires rapid, scalable, and flexible approaches to image segmentation and analysis. Few-shot machine learning, which can richly classify images from a handful of user-provided examples, is a promising route to high-throughput analysis. However, current command-line implementations of such approaches can be slow and unintuitive to use, lacking the real-time feedback necessary to perform effective classification. Here we report on the development of a Python-based graphical user interface that enables end users to easily conduct and visualize the output of few-shot learning models. This interface is portable and can be hosted locally or on the web, providing the opportunity to reproducibly conduct, share, and crowd-source few-shot analyses.

97 MATHEMATICS AND COMPUTING↗

Direct Mapping of Fluorine in Cation Disordered Rocksalt Cathodes

Cation-disordered rocksalt (DRX) oxides are promising candidates as next-generation cathodes for lithium-ion batteries. Partial fluorination of the DRX oxides enhances their cyclability. However, the lattice position, concentration, and spatial distribution of fluorine within DRX lattices remain elusive. Here, in this work, we use atom location by channeling-enhanced microanalysis, energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy, and integrated differential phase contrast imaging in a scanning transmission electron microscope to gain atomic-level insights into DRX with nominal composition of Li 1.2 Mn 0.7 Ti 0.1 O 1.7 F 0.3 and Li 1.15 Ni 0.45 Ti 0.3 Mo 0.1 O 1.85 F 0.15 . We reveal that fluorine substitutes oxygen in the DRX lattices. The O/F ratio in terms of O+F = 2 is in the range from 1.92:0.08 to 1.82:0.18. Spatially, fluorine is distributed in the proximity of the Li-rich regions but distinct from lithium fluoride. Additionally, we observe that incorporation of fluorine in the DRX lattice induces a larger variation in cation–anion separation. These observations provide insight into the guided design of oxyfluoride DRX cathodes for high-performance batteries.

(S)TEM↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

Review of multi-faceted morphologic signatures of actinide process materials for nuclear forensic science

Particle morphology is an emerging signature that has the potential to identify the processing history of unknown nuclear materials. Using readily available scanning electron microscopes (SEM), the morphology of nearly any solid material can be measured within hours. Coupled with robust image analysis and classification methods, the morphological features can be quantified and support identification of the processing history of unknown nuclear materials. The viability of this signature depends on developing databases of morphological features, coupled with a rapid data analysis and accurate classification process. With developed reference methods, datasets, and throughputs, morphological analysis can be applied within days to (i) interdicted bulk nuclear materials (gram to kilogram quantities), and (ii) trace amounts of nuclear materials detected on swipes or environmental samples. In conclusion, this review aims to develop validated and verified analytical strategies for morphological analysis relevant to nuclear forensics.

36 MATERIALS SCIENCE↗

Revealing Progressive Degradation of Cobalt Oxide Nanoparticles During Thermochemical Redox Cycling via Operando STEM-EELS

Metal oxides are promising materials for long-duration thermochemical energy storage. Efforts to characterize their reaction kinetics, conversion rate, and morphological evolution during thermochemical cycling have largely focused on bulk and microscale measurements. However, the design of nanostructured metal oxides could improve the reaction reversibility and kinetics, warranting the development of platforms to investigate how these materials behave at the nanoscale. Here, we demonstrate the use of correlative, time-resolved electron energy loss spectroscopy and imaging in an environmental transmission electron microscope for studying the thermochemical cyclability of cobalt oxide nanoparticles with high spatial and temporal resolution. The spectroscopic data reveal a striking decrease in reaction kinetics after the first cycle, resulting from sintering-driven nanostructural densification. Comparison between cycling in humid and dry air shows that atmospheric conditions can modulate reaction transition temperatures but have limited effects on sintering over multiple cycles, suggesting long-term durability will instead rely on synthetic and/or nanostructural modifications.

25 ENERGY STORAGE↗

Learning and Controlling Silicon Dopant Transitions in Graphene Using Scanning Transmission Electron Microscopy

A machine learning approach is introduced to determine the transition dynamics of silicon atoms on a single layer of carbon atoms, when stimulated by the electron beam of a scanning transmission electron microscope (STEM). This method is data-centric, leveraging data collected on a STEM. The data samples are processed and filtered to produce symbolic representations, which is used to train a neural network to predict transition probabilities. These learned transition dynamics are then leveraged to guide a single silicon atom throughout the lattice to pre-determined target destinations. Empirical analyses are presented that demonstrate the efficacy and generality of the approach.

36 MATERIALS SCIENCE↗

Tip-Induced 3D Printing on the Nanoscale with Field Emission Scanning Probes

3D printing down to the nanoscale remains a significant challenge. In this paper, the study explores the use of scanning probes that emit low-energy electrons (<100 eV) coupled with the localized injection and electron-induced decomposition of precursor molecules, for the precise localized deposition of 3D nanostructures. The experiments are performed inside the chamber of a scanning electron microscope (SEM), enabling the use of the in-built gas injector system (GIS) with gaseous naphthalene precursor for carbon deposition, as well as immediate inspection of the deposits by SEM. Substrate materials are planar fused silica with thin conductive coatings and non-planar copper wedges. After investigation of the deposition process parameters, various 2D and 3D carbon deposits are grown. Vertical nanowires several microns in length with a diameter <100 nm are achieved and 3D deposits with a high degree of nanoscale branching are also obtained, presumably due to a charging effect. High aspect ratio carbon nanostructures such as those demonstrated here can be employed as miniaturized electrodes or field emitters. The tip-based approach presented thus paves the way toward 3D nanoscale printing of various materials and functional nanostructures.

3D printing↗

Uncertainty-aware particle segmentation for electron microscopy at varied length scales

Electron microscopy is indispensable for examining the morphology and composition of solid materials at the sub-micron scale. To study the powder samples that are widely used in materials development, scanning electron microscopes (SEMs) are increasingly used at the laboratory scale to generate large datasets with hundreds of images. Parsing these images to identify distinct particles and determine their morphology requires careful analysis, and automating this process remains challenging. In this work, we enhance the Mask R-CNN architecture to develop a method for automated segmentation of particles in SEM images. We address several challenges inherent to measurements, such as image blur and particle agglomeration. Moreover, our method accounts for prediction uncertainty when such issues prevent accurate segmentation of a particle. Recognizing that disparate length scales are often present in large datasets, we use this framework to create two models that are separately trained to handle images obtained at low or high magnification. By testing these models on a variety of inorganic samples, our approach to particle segmentation surpasses an established automated segmentation method and yields comparable results to the predictions of three domain experts, revealing comparable accuracy while requiring a fraction of the time. These findings highlight the potential of deep learning in advancing autonomous workflows for materials characterization.

36 MATERIALS SCIENCE↗

Closing the loop between microstructure and charge transport in conjugated polymers by combining microscopy and simulation

A grand challenge in materials science is to identify the impact of molecular composition and structure across a range of length scales on macroscopic properties. We demonstrate a unified experimental–theoretical framework that coordinates experimental measurements of mesoscale structure with molecular-level physical modeling to bridge multiple scales of physical behavior. Here we apply this framework to understand charge transport in a semiconducting polymer. Spatially-resolved nanodiffraction in a transmission electron microscope is combined with a self-consistent framework of the polymer chain statistics to yield a detailed picture of the polymer microstructure ranging from the molecular to device relevant scale. Using these data as inputs for charge transport calculations, the combined multiscale approach highlights the underrepresented role of defects in existing transport models. Short-range transport is shown to be more chaotic than is often pictured, with the drift velocity accounting for a small portion of overall charge motion. Local transport is sensitive to the alignment and geometry of polymer chains. At longer length scales, large domains and gradual grain boundaries funnel charges preferentially to certain regions, creating inhomogeneous charge distributions. While alignment generally improves mobility, these funneling effects negatively impact mobility. The microstructure is modified in silico to explore possible design rules, showing chain stiffness and alignment to be beneficial while local homogeneity has no positive effect. This combined approach creates a flexible and extensible pipeline for analyzing multiscale functional properties and a general strategy for extending the accesible length scales of experimental and theoretical probes by harnessing their combined strengths.

42 ENGINEERING↗

Dynamic Molecular Investigation of the Solid-Electrolyte Interphase of an Anode-Free Lithium Metal Battery Using In Situ Liquid SIMS and Cryo-TEM

Solid electrolyte interphase (SEI) has been widely perceived to play a critical role in the stable cycling of rechargeable batteries. However, associated with the fragile and air-sensitive nature of the SEI layer, delineation of the formation process and the nature of SEI remains a big challenge. Here, we use in situ liquid time-of-flight secondary ion mass spectroscopy (TOF-SIMS), cryo- transmission electron microscope (TEM) and density functional theory (DFT) calculation to delineate molecular process on the formation of SEI layer under the dynamic operating condition. We discover that the onset potential for SEI layer formation and the thickness of the SEI show dependence on the solvation shell structure. Using LiCoO 2 as a cathode and Cu film as an anode, the SEI is noticed to start to form at around 2.0 V and reach its final thickness (irreversible part, ~ 40-50 nm) at about 3.0 V in the 1 M LiPF 6 –EC/DMC electrolyte, while for the case of 1 M LiFSI–DME, the SEI starts to form at around 1.5 V and reaches its final thickness (~ 20 nm) at about 2.0 V. The in situ TOF-SIMS clearly indicates the outer SEI layer formation and dissipation upon charging and discharging, implying a continued evolution of electrolyte structure with extended cycling. In conclusion, the present work establishes a direct correlation between the molecular signature of SEI layer with solvation feature of electrolytes in lithium batteries, providing insights for tailoring SEI layer toward improved electrochemical properties of lithium batteries.

25 ENERGY STORAGE↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of the dielectric and magnetocaloric properties of bulk and film of GdFe 0.5 Cr 0.5 O 3

Here, we report a comparison of the magnetic, magnetocaloric, and dielectric properties of 50% iron substituted GdCrO 3 (GdFe 0.5 Cr 0.5 O 3 ) bulk pellet and 960 nm thick film of GdFe 0.5 Cr 0.5 O 3 (GFCO). The 960 nm film was synthesized on a platinized-silicon substrate by chem. soln. deposition and spin-coating methods. The X-ray diffraction scans of the bulk sample and the film as well as the morphology of the film as examined by the field-emission scanning electron microscope indicate phase-pure and polycrystalline nature of these samples. XPS was used to deermine the valence states of Gd, Fe, and Cr. The temp. dependence of the dielectric const. from 225 to 700 K shows peaks at T C = 525 K for the bulk and ≈450 K for the film due to ferroelectric to paraelectric transitions, since elec. polarization vs elec. field hysteresis loops are observed. at room temp. The dielectric studies in the bulk GFCO for T > T C indicate a relaxor-like behavior. The measurements of the magnetization (M) of the samples as a function of temp. (5-350 K) and magnetic field (H) up to 7 T (=70 kOe) depict hysteresis behavior at low temps. due to the canted antiferromagnetic order of Fe 3+ /Cr 3+ below the Néel temp. of ≈275 K. The M vs H isotherms at various temps. are used to det. and compare the magnetic entropy change (-ΔS) and relative cooling power (RCP) of the two samples, yielding (-ΔS) = 30.7 J/kg K (18.8 J/kg K) and RCP = 566.5 J/kg (375 J/kg) for the bulk (960 nm film) samples of GFCO at 7 K and 7 T, resp. The plot of RCP vs T shows that magnetic cooling for this system is most effective for T < 30 K. Comparatively smaller magnitudes of (-ΔS) and RCP for the film vis-a-vis the bulk sample of GFCO scale with its reduced magnetization. This suggests that further improvements in the quality of the films are needed to improve their magnetization and hence their magnetocaloric properties, possibly making them useful for on-chip cooling in miniaturized devices.

36 MATERIALS SCIENCE↗

Protective effects of intravitreal administration of mesenchymal stem cell-derived exosomes in an experimental model of optic nerve injury

Traumatic optic neuropathy results in the loss of retinal ganglion cells (RGCs), leading to unavoidable visual impairment. However, there is no effective therapy by far. Accumulated studies support the perception that mesenchymal stem cells (MSCs) secrete exosomes that serve as a protective paracrine factor. The study aimed to explore and evaluate the potential therapeutic effects of intravitreal transplantation of MSC-derived exosomes (MSC-exos) in an experimental model of optic nerve crush (ONC). Exosomes were isolated from rat MSCs and characterized by transmission electron microscope and western blotting. At the onset of ONC, a single intravitreal injection of exosomes or PBS was administered to the rats. At day 30, hematoxylin and eosin staining, immunohistochemistry, and βIII-tubulin staining were performed to evaluate the survival of RGCs. Moreover, TUNEL assay was used to examine the apoptosis of RGCs. Inflammation-relevant factors were identified via quantitative polymerase chain reaction. The expression levels of cell apoptosis-related molecules and key members of the PI3K/AKT signaling pathway were determined via western blot analysis. We found that MSC-exos exhibited typical characteristic morphologies (cup-shaped) and sizes (peak size of 93 nm). Furthermore, they exhibited substantial expression of the exosome markers CD63 and TSG101, but lacked the expression of the cellular marker GM130. Treatment with intravitreal MSC-exos notably promoted the survival of RGCs in ONC rats. The level of pro-inflammatory cytokines, including TNF-α, IL-1β, IL-6, IL-8, and MCP-1, were reduced, whereas those of the anti-inflammatory factor IL-10 were increased. Moreover, the apoptosis induced by ONC was decreased by the administration of MSC-exos via upregulation of the Bcl-2/Bax ratio and downregulation of caspase-3 activity. Furthermore, MSC-exos significantly stimulated AKT phosphorylation, whereas LY294002 restored the apoptosis-preventing effects of MSC-exos. The results of our results demonstrated that intravitreal administration of MSC-exos ameliorates ONC-induced injury in a rat model. These findings might aid in the development of effective exosome-based therapeutic strategies for the treatment of optic nerve degeneration.

60 APPLIED LIFE SCIENCES↗

Switching speed limits in electrically driven VO 2 structural Mott–Peierls transition

Mott materials are archetypal quantum systems actively explored as next-generation electronic and photonic platforms, with potential applications spanning non-Von Neumann computing, robotics, energy storage, and microwave technologies. Among these, vanadium dioxide (VO 2 ) has emerged as one of the most intensively studied compounds, owing to its sharp, near-room-temperature insulator-to-metal phase transition. VO 2 also serves as a benchmark system for testing cutting-edge theories and experimental techniques. Here, we directly visualize the electrically driven transition dynamics in VO 2 using a microwave-driven, frequency-tunable pulsed transmission electron microscope that combines nanometer spatial and picosecond temporal resolution. Under high-frequency (MHz–GHz) excitation, we capture the ultrafast nucleation, propagation, and dissolution of metallic domains within an operating device over millions of reversible cycles. We observe the ultrafast formation of consistent metallic nuclei beneath the electrodes, followed by the propagation of a structural phase front at 4.54 nm/ns. Our experiments show that phonon-mediated structural recovery ultimately limits reversible switching of VO 2 at GHz frequencies, and that a tunable regime for reversible operation spans from kHz to GHz through device engineering. Beyond VO 2 , our approach provides a powerful framework for probing non-equilibrium structural transformations in correlated and functional materials under realistic electrical stimuli.

36 MATERIALS SCIENCE↗

Radiation induced amorphization of carbides in additively manufactured and conventional ferritic-martensitic steels: In-situ experiments on extraction replicas

In-situ irradiations using 1 MeV Kr 2+ ions in a transmission electron microscope were performed on extraction replica samples containing M 23 C 6 carbides and MX carbonitrides from two ferritic-martensitic (FM) steels: (i) 9%Cr-1%W-TaV based Eurofer97 and (ii) 9%Cr-1%Mo-VNb (all in wt.%) based additively manufactured (AM) Grade91 steel. The irradiations were performed between 100 and 773 K up to a maximum dose of ~2.4 displacements per atom (dpa). The M 23 C 6 carbides are highly susceptible to radiation induced amorphization (RIA), while the MX type nanoprecipitates are highly amorphization resistant across the entire irradiation temperature range. Between 100 and 423 K, RIA of M 23 C 6 carbides occurs very rapidly with critical amorphization doses ranging between ~0.35 and 0.9 dpa, increasing to higher doses at 573 K. Complete amorphization of the M 23 C 6 carbides up to doses of ~2.4 dpa is not possible at 773 K under the present irradiation conditions. The critical amorphization dose of M 23 C 6 carbides increases nearly exponentially with irradiation temperature. The critical temperature for the crystalline-to-amorphous phase transformation (T c→a ) of M 23 C 6 carbides irradiated as replica samples, i.e. without the surrounding metal matrix, was estimated to be ~812 K. Comparing the present results with neutron irradiation data on bulk samples reveals a decrease in the critical amorphization dose for M 23 C 6 and an increase of T c→a , highlighting the effect of dose rate on the amorphization behavior that is qualitatively consistent with literature on other non-metals. Changes in the minor chemistry of M 23 C 6 , such as presence or absence of W, V, Nb, Mo, seems to have little effect on the amorphization behavior. Here, in-situ irradiations on extraction replica samples provide a novel pathway to explore radiation tolerance of nanoprecipitates in nuclear structural materials

36 MATERIALS SCIENCE↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

Proposed Analytical Methods for Determining Filter Media Properties

High Efficiency Particulate Air (HEPA) filters, commonly used in nuclear filtration applications, are an integral part of the waste management processes in nuclear plants. HEPA filters are 99.97% efficient filtration devices characterized by their high resistance to air flow, or pressure drop. From theoretical models, the initial pressure drop across a clean filter is proven to be a function of the filter media fiber diameters and porosity of the media. These filter properties are relatively difficult to obtain with traditional manual methods; therefore, there is a need to develop analytical methods to find the fiber diameter and porosity to determine the pressure drop. Typically, these values can be found by substituting a calculated representative value based upon measured values, such as equivalent fiber diameter based upon a clean pressure drop. However, these values may also be directly recorded and measured by incorporating Scanning Electron Microscope (SEM) image analysis and other measurement methods to analyze the filter media and determine its physical properties without the need for media testing. DiameterJ, an open source Java plug-in, used with ImageJ, can process images of filter media taken by an SEM to find statistical data such as mean fiber diameter and porosity. To produce the raw data, SEM images of two filter media type samples are taken and segmented in DiameterJ using the traditional and statistical region merging segmentation algorithms. Manual segmentation is necessary after the initial segmentation by the algorithms as the images tend to be too complex for the algorithms to output with the necessary accuracy. However, complications exist in the manual segmentation process as these methods can be time intensive and prone to the individual bias of the user. This in turn can skew the final mean fiber diameter result, and lead to either an over or under prediction of the pressure drop. It was also discovered that the porosity data produced by DiameterJ is inaccurate, as the SEM analyzes the three-dimensional filter media by projecting its geometry onto a plane and analyzing it as a two-dimensional binary image. Thus, the porosity is artificially inflated through the segmentation process, rendering this result incorrect. Alternatively, density determination, gravimetric analysis, and thickness testing of the filter media is collectively used to determine the filter fiber porosity. Together, the SEM image analysis and analytical lab methods produce results through direct measurements which allow for the prediction of the initial pressure drop from clean filter media without the need for prior media testing to collect pressure data. By improving upon this proposed analytical method in the future, there is potential to streamline the process of finding these filter properties into a more direct methodology for determining the pressure drop across HEPA filters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗