Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A general Bayesian algorithm for the autonomous alignment of beamlines

Autonomous methods to align beamlines can decrease the amount of time spent on diagnostics, and also uncover better global optima leading to better beam quality. The alignment of these beamlines is a high-dimensional expensive-to-sample optimization problem involving the simultaneous treatment of many optical elements with correlated and nonlinear dynamics. Bayesian optimization is a strategy of efficient global optimization that has proved successful in similar regimes in a wide variety of beamline alignment applications, though it has typically been implemented for particular beamlines and optimization tasks. In this paper, we present a basic formulation of Bayesian inference and Gaussian process models as they relate to multi-objective Bayesian optimization, as well as the practical challenges presented by beamline alignment. We show that the same general implementation of Bayesian optimization with special consideration for beamline alignment can quickly learn the dynamics of particular beamlines in an online fashion through hyperparameter fitting with no prior information. We present the implementation of a concise software framework for beamline alignment and test it on four different optimization problems for experiments on X-ray beamlines at the National Synchrotron Light Source II and the Advanced Light Source, and an electron beam at the Accelerator Test Facility, along with benchmarking on a simulated digital twin. We discuss new applications of the framework, and the potential for a unified approach to beamline alignment at synchrotron facilities.

47 OTHER INSTRUMENTATION↗

ACCELERATOR CHALLENGES OF THE LHeC PROJECT

The LHeC project studies the design of a future electron-proton collider at CERN that will run in parallel to the standard LHC operation. For this purpose, the existing LHC storage ring will be combined with an Energy Recovery Linac (ERL), to accelerate electrons up to kinetic energy of 50 GeV. This concept - also applicable to the FCC-eh collider and studied at the PERLE project as prototype version - allows a peak luminosity of 10³⁴ cm⁻² s⁻¹. A sophisticated design of the RF structures, linacs, arcs, and interaction region is required. The electrons are accelerated and, after the interaction point, their energy is recovered through the same RF structures. While this energy recovery concept is a very promising approach, severe challenges are set by the layout of the interaction region, the beam separation concept and the design of the linac and arc lattice for the highest possible momentum acceptance. Emittance control and beam-beam effect of both, electron and proton beams, have been studied in front-to-end simulations and will be presented. We summarise the design principles of the ERL, the optimization of the arc lattice, and the main parameters of the project.

Holzer, B. J.↗

HiPEP Ion Optics System Evaluation Using Gridlets

Experimental measurements are presented for sub-scale ion optics systems comprised of 7 and 19 aperture pairs with geometrical features that are similar to the HiPEP ion optics system. Effects of hole diameter and grid-to-grid spacing are presented as functions of applied voltage and beamlet current. Recommendations are made for the beamlet current range where the ion optics system can be safely operated without experiencing direct impingement of high energy ions on the accelerator grid surface. Measurements are also presented of the accelerator grid voltage where beam plasma electrons backstream through the ion optics system. Results of numerical simulations obtained with the ffx code are compared to both the impingement limit and backstreaming measurements. An emphasis is placed on identifying differences between measurements and simulation predictions to highlight areas where more research is needed. Relatively large effects are observed in simulations when the discharge chamber plasma properties and ion optics geometry are varied. Parameters investigated using simulations include the applied voltages, grid spacing, hole-to-hole spacing, doubles-to-singles ratio, plasma potential, and electron temperature; and estimates are provided for the sensitivity of impingement limits on these parameters.

Willliams, John D.↗

Ion Trapping Studies and Mitigation Strategies for the EIC ERL-Based Strong Hadron Cooler

An Energy Recovery Linac based strong hadron cooler was previously considered for the Electron-Ion Collider. The required electron beam parameters for variable-energy strong hadron cooling place significant constraints on ion trapping and collective effects. This paper presents initial studies of these constraints through a combination of analytical modelling and numerical simulations of ion production, trapping behaviour, and mitigation strategies. A multi-bunch tracking framework based on ELEGANT with the ionEffects module is used to simulate machine operation over millisecond time scales, corresponding to more than 3 × 10^5 electron bunches. The simulations include modelling of ionisation processes together with transverse electron–ion dynamics, allowing the evolution and accumulation of ions to be investigated. Analytical expressions based on Gaussian beam distributions are used to estimate ion trapping conditions and benchmark the simulation results. A bi-periodic bunch spacing scheme is also investigated as a possible mitigation method by detuning the ion oscillation frequency. These studies provide an initial assessment of ion trapping in the strong hadron cooler and demonstrate possible approaches for reducing beam–ion effects.

Bi, R. [Lancaster University, Cockcroft Institute]↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Energy Electron Detection with ATIC

The ATIC (Advanced Thin Ionization Calorimeter) balloon-borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons. The instrument was exposed to high-energy beams at CERN H2 bean-dine in September of 1999. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well.

Chang, J.↗

Theory and simulation of the beam cyclotron instability.

A theory of plasma beam cyclotron instability is developed on the basis of computer simulation experiments. The theory holds that at certain turbulence levels, electron cross-field diffusion which supresses the electron gyroresonances is created by turbulent wave-particle interactions in a plasma beam after a period of quasi-linear exponential development of turbulence. The stabilizing effect of Landau ion damping is noted. The behavior of cold and hot ions is discussed.

Lampe, M.↗

AMPS data management requirements study, appendix 1

Flow charts and display formats for the simulation of five experiments are given. The experiments are: (1) electromagnetic wave transmission; (2) passive observations of ambient plasma; (3) ionospheric measurements with subsatellite; (4) electron accelerator beam measurements; and (5) measurement of acoustical gravity waves in the sodium layer using lasers. A detailed explanation of the simulation procedure, definition of variables, and an explanation of how the experimenter makes display choices is also presented. A functional description is included on each flow chart and the assumptions and definitions of terms and scope of the flow charts and displays are presented.

Source record↗

GETaLM: A generator for electron tagger and luminosity monitor for electron - proton and ion collisions

The study of elastic bremsstrahlung and electron tagging in electron-proton or ion collisions is gaining importance with the planned construction of several experimental facilities focused on deep-inelastic scattering (DIS) measurements. This paper describes a program which generates bremsstrahlung photons in electron-proton and electron-ion interactions as well as scattered electrons in bremsstrahlung processes and in a quasi-real photon approximation to the general DIS process. Here, the effects of electron beam divergence and the spread of the interaction vertex are implemented. The program can be used as an input to simulations of instrumentation for bremsstrahlung photon detection, luminosity measurements, electron tagging, and the determination of the cross sections of corresponding processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mitigation of space charge effects using electron column at IOTA ring

We investigate a novel method to mitigate space charge effects of high intensity proton beams propagating in circular accelerators by means of trapping and controlling electrons generated from beam-induced residual gas ionization. This compensation method uses Coulomb repulsion force between a proton beam and electrons to mitigate self-space charge effects of the beam if it passes through a plasma column. The transverse electron-proton (e-p) instability in the plasma column is well controlled by the longitudinal magnetic field of a solenoid magnet and the bias voltages on electrodes. In this report, we will show simulation results how to control distributions of electrons and ions as well as that of the proton beam inside the column.

43 PARTICLE ACCELERATORS↗

Electrostatic waves due to field-aligned electron beams in the low-latitude boundary layer

Mass-resolved ion, electron, and plasma wave data obtained from several low-latitude boundary layer (LLBL) crossings by the AMPTE CCE satellite are analyzed. The data clearly separate the LLBL from the adjacent magnetosheath and magnetosphere. Attention was focused on wave-particle interactions involving electrons. Electron beams were found to be present in the LLBL during the southward interplanetary magnetic field, along with a simultaneous enhancement of electrostatic waves with parallel polarization. Linear theory analysis shows that for plasma conditions in the LLBL, electron beams are unstable to electrostatic waves that propagate parallel to the local magnetic field, in agreement with observations. A numerical simulation study of the beam-plasma interaction in the LLBL shows that the instability saturates by thermalization of the beam but that a beamlike structure can still remain in the electron distribution for certain initial parameters. It is suggested that peaks in the electron velocity distribution function may be found in the LLBL away from the beam source region.

Peroomian, V.↗

The positron arm of a plasma-based linear collider

Plasma-based acceleration of electrons has produced high-energy beams at high accelerating gradients with a narrow energy spread and high efficiency both in experiments and simulations. Furthermore, it is now being considered as a complementary approach to the use of radiofrequency cavities in next-generation lepton accelerators. However, compared with electrons, plasma-based positron acceleration is at the present time much less advanced. Although high-gradient positron acceleration in a plasma has been achieved, we are one to three orders of magnitude away from delivering the high-quality positron beams needed for a future high-energy linear collider. Here we review the status of plasma-based acceleration of electrons and positrons and discuss the prospects for substantial progress towards developing the positron arm of a plasma-based electron–positron linear collider in the next decade.

Plasma-based accelerators↗

Evidence of restricted heat transport in National Ignition Facility Hohlraums

We present experimental evidence of restricted electron thermal conduction in the high-Z coronal plasma regions of laser-driven Hohlraums on the National Ignition Facility. Four separate measurements, three of which are direct observations of Hohlraum dynamics, corroborate this finding. (1) The velocity of the coronal plasma ablated and heated by the outer-cone laser beams is determined by time-dependent imaging of the gold plasma plume, or “bubble.” The velocities of the incoming plume (perpendicular to the Hohlraum axis) are consistent with high-fidelity 2D radiation-hydrodynamic simulations using flux-limited thermal electron conduction with a flux multiplier f = 0.03. Simulations using f = 0.15, which is very nearly classical Spitzer–Härm transport, predict plume velocities slower than measured. (2) Specific features in time-resolved images of the Hohlraum wall at an angle of 19° are also more consistent with f = 0.03 simulations compared to f = 0.15. (3) Spectroscopic tracers were added to the Hohlraum wall in the outer-beam bubble region. The ratios of hydrogen-like to helium-like line emission are sensitive to the electron temperature of the bubble. The hydrogen-like to helium-like ratios extracted from the time-integrated spectra of manganese and cobalt tracers from two observation angles are consistent with f = 0.03 and not with f = 0.15. (4) The time of peak capsule emission, or “bang time,” an integrated measurement, is also more consistent with f = 0.03 than with f = 0.15. Overall, while these findings do not identify the causes of restricted thermal conduction in Hohlraums, they motivate future experiments to test specific hypotheses and focus on model development in the regions of the plasma exhibiting restricted transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Electron Source for Laboratory Simulation of the Space Environment

We have developed a new collimated electron source called the Photoelectron Beam Generator (PEBG) for laboratory and spaceflight applications. This technology is needed to replace traditional cathodes because of serious fundamental weaknesses with the present state of the art. Filament cathodes suffer from numerous practical problems, even if expertly designed, including the dependence of electron emission on filament temperature, short lifetimes (approx 100 hours), and relatively high power (approx 10s of W). Other types of cathodes have solved some of these problems, but they are plagued with other difficult problems, such as the Spindt cathode's extreme sensitivity to molecular oxygen. None to date have been able to meet the demand of long lifetime, robust packaging, and precision energy and flux control. This new cathode design avoids many common pitfalls of traditional cathodes. Specifically, there are no fragile parts, no sensitivity to oxygen, no intrinsic emission dependencies on device temperature, and no vacuum requirements for protecting the source from contamination or damage. Recent advances in high-brightness Light Emitting Diodes (LEDs) have provided the key enabling technology for this new electron source. The LEDs are used to photoeject electrons off a target material of a low work-function, and these photoelectrons are subsequently focused into a laminar beam using electrostatic lenses. The PEBG works by illuminating a target material and steering photoelectrons into a laminar beam using electrostatic lenses

Krause, Linda Habash↗

Pressure and current balance conditions during electron beam injections from spacecraft

Electrostatic charging level of a conducting surface in response to injections of electron beams into space plasma is investigated by means of one-dimensional Vlasov code. Injections of Maxwellian beams into a vacuum shows that the surface can charge up to an electric potential phi sub s greater than W sub b, where W sub b is the average electron beam energy. Since Maxwellian beams have extended trails with electrons having energies greater than W sub b, it is difficult to quantify the charging level in terms of the energies of the injected electrons. In order to quantitatively understand the charging in excess of W sub b, simulations were carried out for water-bag types of beam with velocity distribution functions described by f(V) = A for V sub min approx. less than V approx. less than V sub max and f(V) = O otherwise, where A is a constant making the normalized beam density unity. It is found that V sub max does not directly determine the charging level. The pressure distribution in the electron sheath determines the electric field distribution near the surface. The electric field in turn determines the electrostatic potential of the vehicle. The pressure distribution is determined by the beam parameters such as the average beam velocity and the velocity spread of the beam.

Hwang, K. S.↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sodium tracer measurements of an expanded dense aluminum plasma from e-beam isochoric heating

Spatially and temporally resolved visible absorption spectroscopy is performed on sodium D-lines present as surface contaminants on an expanded dense aluminum plasma plume. An 80-ns FWHM, intense, relativistic electron beam deposits 5.4 J into a 100- μ m-thick Al foil, which isochorically heats and subsequently hydrodynamically expands the material through the warm dense matter state and into a classical-like plasma state, with a coupling parameter of approximately 0.2 and a degeneracy parameter of approximately 270. The Na contamination, carried along with the expanding plume, shows saturated absorption features in the dense Al continuum for λ > 450 nm. X-ray photoelectron spectroscopy and laser-induced breakdown spectroscopy confirm Na is a surface contaminant with an atomic concentration of ~ 0.1 % when interrogating identical foil samples. Additioanlly, a spectroscopic-quality radiation transport model is used to post-process 2D hydrodynamic simulations to interpret the plasma conditions based on the measured Na 3p-3s doublet line profiles. A sodium number density of 3 × 10 15 cm -3 best matches the experimental spectra, which originate from a dense surface plasma with n e = 3.0 ± 0.8 × 10 18 cm -3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗