Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrode geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Beneficial Effects of La 0.5 Sr 0.5 CoO 3 Coatings on Thin‐Film LiMn 2 O 4 Cathodes for Lithium Ion Batteries

Abstract The severe capacity loss of spinel LiMn 2 O 4 (LMO) limits the utility of this otherwise promising lithium ion battery cathode material. One of the strategies to mitigate capacity fade is applying a coating on LMO particle surfaces. While this approach yields promising results, there is limited understanding of mechanisms whereby coatings improve LMO capacity retention. Herein, the effects of a new protective coating material, La 0.5 Sr 0.5 CoO 3 (LSCO), in a thin‐film battery geometry that is amenable to fundamental studies of electrode processes, are reported. RF sputtering deposition is used to produce high quality 25–100 nm LMO cathodes on Al 2 O 3 substrates with an intervening Pt/Ti back‐side contact layer. Cycling of the un‐coated cathodes results in capacity loss of 18% over 300 cycles. Adding a 2 nm LSCO layer reduces the capacity loss to 3%. While this may be due in part to reduced Mn dissolution, scanning transmission electron microscopy results indicate that the coating helps to preserve crystallinity and reduce lattice structure distortion due to inhibited formation of defect tetragonal spinel. Three‐electrode electrochemical impedance spectroscopy results reveal that the LSCO coating increases charge transfer and ohmic resistances, but the increases are generally too small to significantly impact cell performance even at high C‐rates.

25 ENERGY STORAGE↗

Microsecond ramp compression of a metallic liner driven by a 5 MA current on the SPHINX machine using a dynamic load current multiplier pulse shaping

SPHINX is a 6 MA, 1-μs Linear Transformer Driver (LTD) operated by the CEA Gramat (France) and primarily used for imploding Z-pinch loads for radiation effects studies. Among the options that are currently being evaluated to improve the generator performances are an upgrade to a 20 MA, 1-μs LTD machine and various power amplification schemes, including a compact Dynamic Load Current Multiplier (DLCM). A method for performing magnetic ramp compression experiments, without modifying the generator operation scheme, was developed using the DLCM to shape the initial current pulse in order to obtain the desired load current profile. In this paper, we discuss the overall configuration that was selected for these experiments, including the choice of a coaxial cylindrical geometry for the load and its return current electrode. We present both 3-D Magneto-hydrodynamic and 1D Lagrangian hydrodynamic simulations which helped guide the design of the experimental configuration. Initial results obtained over a set of experiments on an aluminium cylindrical liner, ramp-compressed to a peak pressure of 23 GPa, are presented and analyzed. Details of the electrical and laser Doppler interferometer setups used to monitor and diagnose the ramp compression experiments are provided. In particular, the configuration used to field both homodyne and heterodyne velocimetry diagnostics in the reduced access available within the liner's interior is described. Current profiles measured at various critical locations across the system, particularly the load current, enabled a comprehensive tracking of the current circulation and demonstrate adequate pulse shaping by the DLCM. The liner inner free surface velocity measurements obtained from the heterodyne velocimeter agree with the hydrocode results obtained using the measured load current as the input. An extensive hydrodynamic analysis is carried out to examine information such as pressure and particle velocity history profiles or magnetic diffusion across the liner. The potential of the technique in terms of applications and achievable ramp pressure levels lies in the prospects for improving the DLCM efficiency through the use of a closing switch (currently under development), reducing the load dimensions and optimizing the diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrostatically driven helical plasma state

A novel plasma state has been found in the presence of a uniformly applied axial magnetic field in periodic cylindrical geometry. This state is driven electrostatically by helical electrodes, providing a driving field that depends on the radius and mθ−nζ, where θ is the poloidal angle and ζ=z/R is the toroidal angle. We focus on m=n=1. The radial magnetic field at the wall is taken to be zero. With weak driving, the resulting distortion is very small, but for stronger driving, the mean field of the state has field line safety factor q0(r) just above the pitch of the electrodes m∕n = 1 except near the edge, where q0 increases monotonically. This state is characterized as a single helicity Ohmic equilibrium with the helical symmetry of the applied field. The plasma appears to be close to force-free in the interior, but current density crosses the magnetic flux surfaces near the edge, where current must enter and exit through the helical electrodes. This perpendicular current density drives large helical plasma flows. The sensitivity of this state to flow boundary conditions, plasma resistivity profile, the strength of electrostatic driving, and parameters such as the loop voltage and the Lundquist number is explored. The magnetic helicity is calculated for both the transient period and time-asymptotic state. Possible applications to current drive in toroidal confinement devices and to electrical transformers are discussed.

Akçay, Cihan↗

Investigating instabilities in magnetized low-pressure capacitively coupled RF plasma using particle-in-cell (PIC) simulations

The effect of a uniform magnetic field on particle transport in low-pressure radio frequency (RF) capacitively coupled plasma (CCP) has been studied using a particle-in-cell model. Three distinct regimes of plasma behavior can be identified as a function of the magnetic field. In the first regime at low magnetic fields, asymmetric plasma profiles are observed within the CCP chamber due to the effect of $\overrightarrow{E}$ × $\overrightarrow{B}$ drift. As the magnetic field increases, instabilities develop and form self-organized spoke-shaped structures that are distinctly seen within the bulk plasma closer to the sheath. In this second regime, the spoke-shaped coherent structures rotate inside the plasma chamber in the -$\overrightarrow{E}$ × $\overrightarrow{B}$ direction, where $\overrightarrow{E}$ × $\overrightarrow{B}$ are the DC electric and magnetic field vectors, respectively, and the DC electric field exists in the sheath and pre-sheath regions. The spoke rotation frequency is in the megahertz range. As the magnetic field strength increases further, the rotating coherent spokes continue to exist near the sheath. The coherent structures are, however, accompanied by new small-scale incoherent structures originating and moving within the bulk plasma region away from the sheath. This is the third regime of plasma behavior. The threshold values of the magnetic field between these regimes were found not to vary with changing plasma reactor geometry (e.g., area ratio between ground and powered electrodes) or the use of an external capacitor between the RF-powered electrode and the RF source. The threshold values of the magnetic field between these regimes shift toward higher values with increasing gas pressure. Analysis of the results indicates that the rotating structures are due to the lower hybrid instability driven by density gradients and electron-neutral collisions. This paper provides guidance on the upper limit of the magnetic field for instability-free operation in low-pressure CCP-based semiconductor deposition and etch systems that use the external magnetic field for plasma uniformity control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improving FAIMS Sensitivity using a Planar Geometry with Slit Interfaces

Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its universal acceptance in stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that could be interfaced to MS more effectively. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The front slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device. The back slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses is raised by over an order of magnitude without affecting the FAIMS resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A three-dimensional meso-macroscopic model for Li-Ion intercalation batteries

Through this study, we present a three-dimensional computational formulation for electrode-electrolyte-electrode system of Li-Ion batteries. The physical consistency between electrical, thermal and chemical equations is enforced at each time increment by driving the residual of the resulting coupled system of nonlinear equations to zero. The formulation utilizes a rigorous volume averaging approach typical of multiphase formulations used in other fields and recently extended to modeling of supercapacitors [1]. Unlike existing battery modeling methods which use segregated solution of conservation equations and idealized geometries, our unified approach can model arbitrary battery and electrode configurations. The consistency of multi-physics solution also allows for consideration of a wide array of initial conditions and load cases. The formulation accounts for spatio-temporal variations of material and state properties such as electrode/void volume fractions and anisotropic conductivities. The governing differential equations are discretized using the finite element method and solved using a nonlinearly consistent approach that provides robust stability and convergence. The new formulation was validated for standard Li-ion cells and compared against experiments. Finally, its scope and ability to capture spatio-temporal variations of potential and lithium distribution is demonstrated on a prototypical three-dimensional electrode problem.

25 ENERGY STORAGE↗

Three-dimensional tracking of cardiac catheters using an inverse geometry x-ray fluoroscopy system

Purpose: Scanning beam digital x-ray (SBDX) is an inverse geometry fluoroscopic system with high dose efficiency and the ability to perform continuous real-time tomosynthesis at multiple planes. This study describes a tomosynthesis-based method for 3D tracking of high-contrast objects and present the first experimental investigation of cardiac catheter tracking using a prototype SBDX system. Methods: The 3D tracking algorithm utilizes the stack of regularly spaced tomosynthetic planes that are generated by SBDX after each frame period (15 frames/s). Gradient-filtered versions of the image planes are generated, the filtered images are segmented into object regions, and then a 3D coordinate is calculated for each object region. Two phantom studies of tracking performance were conducted. In the first study, an ablation catheter in a chest phantom was imaged as it was pulled along a 3D trajectory defined by a catheter sheath (10, 25, and 50 mm/s pullback speeds). SBDX tip tracking coordinates were compared to the 3D trajectory of the sheath as determined from a CT scan of the phantom after the registration of the SBDX and CT coordinate systems. In the second study, frame-to-frame tracking precision was measured for six different catheter configurations as a function of image noise level (662-7625 photons/mm{sup 2} mean detected x-ray fluence at isocenter). Results: During catheter pullbacks, the 3D distance between the tracked catheter tip and the sheath centerline was 1.0{+-}0.8 mm (mean {+-}one standard deviation). The electrode to centerline distances were comparable to the diameter of the catheter tip (2.3 mm), the confining sheath (4 mm outside diameter), and the estimated SBDX-to-CT registration error ({+-}0.7 mm). The tip position was localized for all 332 image frames analyzed and 83% of tracked positions were inside the 3D sheath volume derived from CT. The pullback speeds derived from the catheter trajectories were within 5% of the programed pullback speeds. The tracking precision of ablation and diagnostic catheter tips ranged from {+-}0.2 mm at the highest image fluence to {+-}0.9 mm at the lowest fluence. Tracking precision depended on image fluence, the size of the tracked catheter electrode, and the contrast of the electrode. Conclusions: High speed multiplanar tomosynthesis with an inverse geometry x-ray fluoroscopy system enables 3D tracking of multiple high-contrast objects at the rate of fluoroscopic imaging. The SBDX system is capable of tracking electrodes in standard cardiac catheters with approximately 1 mm accuracy and precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous neutron and X-ray tomography for visualization of graphite electrode degradation in fast-charged lithium-ion batteries

Advanced battery characterization using neutron and X-ray-based imaging modalities is crucial to reveal fundamental degradation modes of lithium-ion batteries (LIBs). Taking advantage of the sensitivity of neutrons to some low-Z (Li) and X-rays to high-Z materials (Cu), here we demonstrate the viability of simultaneous neutron and X-ray tomography (NeXT) as a non-destructive imaging platform for ex-situ 3D visualization of graphite electrode degradation following extreme fast charging (XFC). In addition, we underscore the benefits of the simultaneous of NeXT by combining the neutron and X-ray tomography data from the same sample location for material identification and segmentation of one pristine and two XFC-cycled graphite electrodes (9C charge for 450 cycles). Our ex-situ results and methodology development pave the way for the design of NeXT-friendly LIB geometries that will allow operando and/or in-situ 3D visualization of electrode degradation during XFC.

25 ENERGY STORAGE↗

Effect of electrode spacing on the density distributions of electrons, ions, and metastable and radical molecules in SiH{sub 4}/NH{sub 3}/N{sub 2}/He capacitively coupled plasmas

Semiconductor fabrication often requires the deposition of hydrogenated silicon nitride (SiN{sub x}H{sub y}) film using SiH{sub 4}/NH{sub 3}/N{sub 2}/He capacitively coupled plasma (CCP) discharge. As analysis of the discharge geometry is essential to understanding CCP deposition, the effect of electrode spacing on the two-dimensional distributions of electrons, ions, and metastable and radical molecules was analyzed numerically using a fluid model. The simulation shows that the spatial variations in the ionization rates near the sheath become more obvious as the electrode spacing increases. In addition, as molecule-molecule gas-phase reactions are significantly affected by the local residence time, large electrode spacings are associated with significant volumetric losses for positive ions. Consequently, an increase of the electrode spacing leads axial density profiles of ions to change from bell shaped to double humped. However, NH{sub 4}{sup +} persistently maintains a bell-shaped axial density profile regardless of the degree of electrode spacing. We set the mole fraction of NH{sub 3} to only 1% of the total flow at the inlet, but NH{sub 4}{sup +} is the most abundant positive ion at the large electrode spacings. As the gas flow can transport the radicals around the space between the electrodes, we found that radical density distribution shifts toward the grounded electrode. The shift becomes pronounced as the electrode spacing increases. Finally, to validate our model, we compared the calculated deposition rate profile with the experimental data obtained along the wafer radius. According to our numerical results, the SiN{sub x}H{sub y} deposition rate decreases by approximately 16% when the electrode spacing increases from 9 to 20 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium-Ion Batteries with Safer Current Collectors

The US Department of Energy’s Oak Ridge National Laboratory and Soteria Battery Innovation Group collaborated to develop a metallized polymer film as a current collector for lithium-ion batteries and design slit patterns for electrodes to improve battery safety. The metallized polymer film serves as a fuse that will break under high temperature resulting from a short circuit. Consequently, the short circuit will be broken and the heat generated from the short circuit will be alleviated to avoid thermal runaway. The electrodes with slit patterns are expected to be broken into small segments upon mechanical impact, which can isolate the damaged electrodes from the rest. Thus, the heat generation associated with the mechanical impact will be reduced, along with the likelihood of thermal runaway. This effort aimed to improve lithium-ion battery safety by replacing traditional metal foils with metallized polymer films as current collector and introducing slit patterns to battery electrodes. The metallized polymer films were polyethylene terephthalate with a thin metal (aluminum for cathodes and copper for anodes) coating on both sides. Slit patterns with various geometries and dimensions were designed via simulation. Temperature distribution on cells with electrodes with and without slit patterns was also simulated via nemerical modeling. Electrodes on traditional metal foils and metallized polymer films were coated via a pilot-scale slot-die coater at the US Department of Energy Battery Manufacturing Facility at Oak Ridge National Laboratory. The electrodes were calendered to 35% porosity and punched out with and without slit patterns. Pouch cells were assembed with the electrodes inside a dry room for electrochemical and safety testing. Electrodes coated on metallized polymer films exhibited comparable electrochemical performance to their counterparts coated on traditional metal foils. They also showed improved safety in nail penetration and indentation tests.

25 ENERGY STORAGE↗

In situ AFM studies on lithium (de)intercalation-induced morphology changes in a LixCoO2 micro-machined thin film electrode

Structural instability due to intercalation-induced stresses in electrode materials is one of the key degradation mechanisms of Li-ion batteries. Fragmentation of material degrades structural integrity and electrical resistance, and also accelerates harmful side reactions. In situ experiments are the appropriate approach to investigate the actual time dependent nature of behavior changes of an electrode material while it is charged and discharged. In the current work, a unique in situ electrochemical atomic force microscopy (ECAFM) measurement is made on samples of cylindrical shape, which are micro-machined by focused ion beam (FIB) microscopy. This pre-defined geometry allows the exclusion of secondary, non-active materials from the electrochemically active material as well as the removal of any vagueness coming from the irregular geometry of particles. Also, the experimental results are used to validate a proposed coupled electrochemical and mechanical model for determination of the stress-strain state of active electrode material during electrochemical cycling. The results produced using the model correlate the experimental data rather well. The combined results reveal the key effects of the geometry, kinetics, and mechanics of electrode materials on the stress-strain state, which is a barometer of structural stability of a material.

Park, Jonghuyn↗

A Segregated Approach for Modeling the Electrochemistry in the 3-D Microstructure of Li-Ion Batteries and Its Acceleration Using Block Preconditioners

Abstract Battery performance is strongly correlated with electrode microstructure. Electrode materials for lithium-ion batteries have complex microstructure geometries that require millions of degrees of freedom to solve the electrochemical system at the microstructure scale. A fast-iterative solver with an appropriate preconditioner is then required to simulate large representative volume in a reasonable time. In this work, a finite element electrochemical model is developed to resolve the concentration and potential within the electrode active materials and the electrolyte domains at the microstructure scale, with an emphasis on numerical stability and scaling performances. The block Gauss-Seidel (BGS) numerical method is implemented because the system of equations within the electrodes is coupled only through the nonlinear Butler–Volmer equation, which governs the electrochemical reaction at the interface between the domains. The best solution strategy found in this work consists of splitting the system into two blocks—one for the concentration and one for the potential field—and then performing block generalized minimal residual preconditioned with algebraic multigrid, using the FEniCS and the Portable, Extensible Toolkit for Scientific Computation libraries. Significant improvements in terms of time to solution (six times faster) and memory usage (halving) are achieved compared with the MUltifrontal Massively Parallel sparse direct Solver. Additionally, BGS experiences decent strong parallel scaling within the electrode domains. Last, the system of equations is modified to specifically address numerical instability induced by electrolyte depletion, which is particularly valuable for simulating fast-charge scenarios relevant for automotive application.

25 ENERGY STORAGE↗

Electrostatic ion thruster optics calculations

Calculations have been performed which encompass both a self-consistent ion source extraction plasma sheath and the primary ion optics including sheath and electrode-induced aberrations. Particular attention is given to the effects of beam space charge, accelerator geometry, and properties of the downstream plasma sheath on the position of the electrostatic potential saddle point near the extractor electrode. The electron blocking potential blocking is described as a function of electrode thickness and secondary plasma processes.

Whealton, John H.↗

3D‐Printed Carbon Electrodes for Neurotransmitter Detection

Abstract Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 n m (sphere) and 10±2 n m (cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.

Yang, Cheng↗

3D‐Printed Carbon Electrodes for Neurotransmitter Detection

Abstract Implantable neural microsensors have significantly advanced neuroscience research, but the geometry of most probes is limited by the fabrication methods. Therefore, new methods are needed for batch‐manufacturing with high reproducibility. Herein, a novel method is developed using two‐photon nanolithography followed by pyrolysis for fabrication of free‐standing microelectrodes with a carbon electroactive surface. 3D‐printed spherical and conical electrodes were characterized with slow scan cyclic voltammetry (CV). With fast‐scan CV, the electrodes showed low dopamine LODs of 11±1 n m (sphere) and 10±2 n m (cone), high sensitivity to multiple neurochemicals, and high reproducibility. Spherical microelectrodes were used to detect dopamine in a brain slice and in vivo, demonstrating they are robust enough for tissue implantation. This work is the first demonstration of 3D‐printing of free‐standing carbon electrodes; and the method is promising for batch fabrication of customized, implantable neural sensors.

Yang, Cheng↗

Dilute Regeneration-Driven Membrane Capacitive Deionization of Synthetic Seawater Using Nanopatterned Membranes and Prussian Blue Analog Electrodes

Membrane capacitive deionization (MCDI) offers energy-efficient seawater desalination but is limited at high salinity by membrane resistance and incomplete electrode regeneration. Nanopatterned ion-exchange membranes, dilute regeneration protocols, and Prussian blue analog (PBA)-functionalized electrodes are combined in a flow-by-MCDI cell. Nanopatterned ion-exchange membranes (hexagonal, octagonal, double-ring, rectangular) enhance interfacial ion transport, with hexagonal geometry delivering ≈12.5% greater surface area and the best performance. PBA-functionalized electrodes increase salt adsorption and charge-transfer kinetic rates. The integrated system lowers the area-specific resistance by 45 Ω cm2, resulting in a 500 mV reduction in the cell voltage for a current density of 2 mA cm−2 for a 35 000 ppm NaCl feed. This improves the energy-normalized salt adsorption six fold (64–382 mmol J−1). Low salinity (2000 ppm) and mixed-salt regeneration sustains a ≈39% water recovery and stable performance for at least seven cycles. Overall, combining nanopatterned membranes, which promote confinement-enhanced ion mobility, and PBA electrodes, which enhance salt adsorption, improved the energy efficiency of MCDI.

Hasan, Mahmudul↗

Growth of Lithium Dendrites and Globules through a Solid Block Copolymer Electrolyte as a Function of Current Density

The uncontrollable nonplanar electrodeposition of lithium is a significant barrier to the widespread adoption of high energy density rechargeable batteries with a lithium metal anode. A promising approach for preventing the growth of lithium dendrites is the use of solid polymer electrolytes with a high shear modulus. Current density is the key variable in the electrodeposition of lithium. The present study is the first attempt at quantifying the effect of current density on the geometry and density of dendrites and other protrusions during electrodeposition through a solid polymer electrolyte. The geometry and density of defects formed on the lithium electrode were determined by X-ray microtomography. The tomograms revealed protrusions on the electrodeposited lithium electrodes that were either globular or dendritic, or void defects. The range of current densities over which stable, planar deposition was observed is quantified. At higher current densities, globular protrusions were observed. At the highest current density, both globular and dendritic protrusions were observed. The areal density of protrusion defects increased sharply with current density, while the overall defect density is a weak function of current density. Finally, our work enables comparisons between the experimentally determined onset of nonplanar electrodeposition and prevailing theoretical predictions with no adjustable parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗