Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

4D Electrical Resistivity Imaging of Stress Perturbations Induced During High–Pressure Shear Stimulation Tests

Fluid flow through fractured media is typically governed by the distribution of fracture apertures, which are in turn governed by stress. Consequently, understanding subsurface stress is critical for understanding and predicting subsurface fluid flow. Although laboratory–scale studies have established a sensitive relationship between effective stress and bulk electrical conductivity in crystalline rock, that relationship has not been extensively leveraged to monitor stress evolution at the field scale using electrical or electromagnetic geophysical monitoring approaches. In this paper we demonstrate the use time–lapse 3–dimensional (4D) electrical resistivity tomography to image perturbations in the stress field generated by pressurized borehole packers deployed during shear–stimulation attempts in a 1.25 km deep metamorphic crystalline rock formation.

58 GEOSCIENCES↗

Modeling and Design of an Electro-Rheological Fluid Based Haptic System for Tele-Operation of Space Robots

For many years, the robotic community sought to develop robots that can eventually operate autonomously and eliminate the need for human operators. However, there is an increasing realization that there are some tasks that human can perform significantly better but, due to associated hazards, distance, physical limitations and other causes, only robot can be employed to perform these tasks. Remotely performing these types of tasks requires operating robots as human surrogates. While current "hand master" haptic systems are able to reproduce the feeling of rigid objects, they present great difficulties in emulating the feeling of remote/virtual stiffness. In addition, they tend to be heavy, cumbersome and usually they only allow limited operator workspace. In this paper a novel haptic interface is presented to enable human-operators to "feel" and intuitively mirror the stiffness/forces at remote/virtual sites enabling control of robots as human-surrogates. This haptic interface is intended to provide human operators intuitive feeling of the stiffness and forces at remote or virtual sites in support of space robots performing dexterous manipulation tasks (such as operating a wrench or a drill). Remote applications are referred to the control of actual robots whereas virtual applications are referred to simulated operations. The developed haptic interface will be applicable to IVA operated robotic EVA tasks to enhance human performance, extend crew capability and assure crew safety. The electrically controlled stiffness is obtained using constrained ElectroRheological Fluids (ERF), which changes its viscosity under electrical stimulation. Forces applied at the robot end-effector due to a compliant environment will be reflected to the user using this ERF device where a change in the system viscosity will occur proportionally to the force to be transmitted. In this paper, we will present the results of our modeling, simulation, and initial testing of such an electrorheological fluid (ERF) based haptic device.

Mavroidis, Constantinos↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.

Burkhardt, Wendel M.↗

Pocket ECG electrode

A low noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free ranging subject is described. The electrode comprises a pocket shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member, remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, G. F.↗

Noninvasive estimation of fluid shifts between body compartments by measurement of bioelectric characteristics

Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.

Bishop, Phillip A.↗

Pocket ECG electrode

A low-noise electrode suited for sensing electrocardiograms when chronically and subcutaneously implanted in a free-ranging subject. The electrode comprises a pocket-shaped electrically conductive member with a single entrance adapted to receive body fluids. The exterior of the member and the entrance region is coated with electrical insulation so that the only electrolyte/electrode interface is within the member remote from artifact-generating tissue. Cloth straps are bonded to the member to permit the electrode to be sutured to tissue and to provide electrical lead flexure relief.

Lund, Gordon F.↗

A Low Cost Thermal Control Method for Testing in a Mars Environment

Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.Due to the unique thermal vacuum testing requirements for a Mars Rover instrument, NASA Goddard developed a low cost, high fidelity thermal control system utilizing Thermal Electric Coolers (TECs) combined with a heat rejection fluid loop to actively control 8 independent payload thermal boundary zones in a simulated Mars pressure vacuum chamber with a Carbon Dioxide atmosphere. These zones could control instrument components to a specific temperature as a function of time to simulate exact temporal flight boundary predictions.The Mars Organic Molecule Analyzer (MOMA) instrument is a dual source (pyrolysis gas chromatograph and laser desorption) mass spectrometer (MS) based package that detects and characterizes organic molecules, as part of ESA's 2020 ExoMars Rover mission to seek the signs of life on Mars.

MOMA↗

Free-Surface Liquid Lithium Flow Modeling and Stability Analysis for Fusion Applications

Liquid metal plasma facing components are considered an attractive design choice for fusion devices including pilot plants. Virtual prototyping of such devices includes modeling of free-surface flow of the electrically conductive liquid, which requires computational fluid dynamics (CFD) and magnetohydrodynamics (MHD) simulations. Numerical tools capable of simulating flows and heat transfer in the free-surface MHD flow were developed at PPPL based on the customized ANSYS CFX. Here, MHD is introduced using a magnetic vector potential approach. Free-surface flow capabilities are available in the code and were tested. Special stabilization procedures were derived and applied to improve convergence of the momentum equations with the source terms due to the Lorentz force and surface tension. Important characteristics of the fusion-relevant liquid metal flow is free surface smoothness and stability. Heat flux from the plasma impacts the liquid surface at a very acute angle, so any change of the free surface from axisymmetry can dramatically increase the local heat flux density and thus create excessive evaporation of liquid lithium into the plasma, which is detrimental to operations. Stability analysis of the liquid metal film flow was performed to determine applicable flow regimes. Thin film flow along horizontal wall is considered. Effects of gravity, magnetic field, and surface tension are included in the analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Guiding center and gyrokinetic orbit theory for large electric field gradients and strong shear flows

The guiding center and gyrokinetic theory of magnetized particle motion is extended to the regime of large electric field gradients perpendicular to the magnetic field. A gradient in the electric field directly modifies the oscillation frequency and causes the Larmor orbits to deform from circular to elliptical trajectories. In order to retain a good adiabatic invariant, there can only be strong dependence on a single coordinate at lowest order, so that resonances do not generate chaotic motion that destroys the invariant. When the gradient across magnetic flux surfaces is dominant, the guiding center drift velocity becomes anisotropic in response to external forces and additional curvature drifts must be included. The electric polarization density remains gyrotropic, but both the polarization and magnetization are modified by the change in gyrofrequency. The theory can be applied to shear flows that are even stronger than those observed in the edge transport barrier of a high-performance tokamak (H-mode) pedestal, even if the toroidal field is as small as or even smaller than the poloidal field. Yet, the theory retains a mathematical form that is similar to the standard case and can readily be implemented within existing simulation tools.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topanga: A kinetic ion plasma code for large-scale ionospheric simulations on magnetohydrodynamic timescales

Topanga is a kinetic ion code developed for simulating large-scale plasma phenomena in the Earth's ionosphere on magnetohydrodynamic timescales. It is a domain-decomposed parallel code that runs on high-performance computing platforms. Features of Topanga include spherical geometry for simplified boundary conditions and computational efficiency; a hybrid plasma model with inertia-less fluid electrons, kinetic ions, and an electric field specified via an Ohm's law; a Maxwell-FDTD (finite difference time domain) plasma model which retains the displacement current in Maxwell's equations and models electron currents in the ionosphere with a tensor conductivity; sponge-layer boundary conditions for absorption of electromagnetic and plasma waves incident on the domain boundaries; and a novel mixed-implicit algorithm for evolving the EM fields inside the Maxwell-FDTD region that is stable over many orders of magnitude in the electron–ion collision frequency. We verify the numerical methods used in Topanga on a pair of test problems. The first test involves modeling a three-dimensional collisionless shock using the hybrid set of equations. The second test involves modeling a spherical TEM mode in vacuum using the Maxwell-FDTD set of equations. Finally, we demonstrate how using the combined set of hybrid and Maxwell-FDTD equations to model the Starfish Prime high-altitude nuclear test recovers a “missing” EM signal on the ground that is not present when using only the hybrid set of equations. The magnitude of this signal in the simulation containing the Maxwell-FDTD region agrees well with the E3a portion of the magnetohydrodynamic electromagnetic pulse from Starfish Prime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishing criteria for the transition from kinetic to fluid modeling in hollow cathode analysis

Hollow cathodes for plasma switch applications are investigated via 2D3V particle-in-cell simulations of the channel and plume region. The kinetic nature of the plasma within the channel is dependent on the thermalization rate of electrons, emitted from the insert. When Coulomb collisions occur at a much greater rate than ionization or excitation collisions, the electron energy distribution function rapidly relaxes to a Maxwellian and the plasma within the channel can be described accurately via a fluid model. In contrast, if inelastic processes are much faster than Coulomb collisions, then the electron energy distribution function in the channel exhibits a notable high-energy tail, and a kinetic treatment is required. This criterion is applied to hollow cathodes from the literature, revealing that a fluid approach is suitable for most electric propulsion applications, whereas a kinetic treatment can be more critical to accurate modeling of plasma switches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CalWave - Open Water Demonstration - System and Component Overview Content Models and Drawings

Data for the CalWave - Open Water Demonstration, a submerged pressure differential Wave Energy Converter (WEC) Device. Device is moored to the seabed, and the motion of the waves causes the sea level to rise and fall above the device, inducing a pressure differential in the device. The alternating pressure pumps fluid through a system to generate electricity, which is transmitted to shore via bidirectional cables. Documentation and data here includes: System Overview Content Model and Drawings as well as Component Overview Content Model and Drawings.

16 TIDAL AND WAVE POWER↗

CalWave - Open Water Demonstration - LCOE Content Model

Data for the CalWave - Open Water Demonstration, a submerged pressure differential Wave Energy Converter (WEC) Device. Device is moored to the seabed, and the motion of the waves causes the sea level to rise and fall above the device, inducing a pressure differential in the device. The alternating pressure pumps fluid through a system to generate electricity, which is transmitted to shore via bidirectional cables. Documentation and data here includes: Levelized Cost of Energy (LCOE) Content Model

16 TIDAL AND WAVE POWER↗

CalWave - Open Water Demonstration - Field Testing Content Models (10/21 - 7/22)

Data for the CalWave - Open Water Demonstration, a submerged pressure differential Wave Energy Converter (WEC) Device. Device is moored to the seabed, and the motion of the waves causes the sea level to rise and fall above the device, inducing a pressure differential in the device. The alternating pressure pumps fluid through a system to generate electricity, which is transmitted to shore via bidirectional cables. Documentation and data here includes: Open Water Demonstration, including field testing content models for nearly 10 months of continuous ocean operation, from October 2021 through July 2022.

16 TIDAL AND WAVE POWER↗

Exploration of Binder Jet Additive Manufacturing for Automotive Heat Sink Component Fabrication

ORNL (Contractor) and Magna Services of America Inc. (Participant) collaborated to determine the feasibility of binder jet additive manufacturing (BJAM) for the fabrication of copper components for automotive heat sink applications. This Phase 1 collaboration focused on printing copper heat sinks that rely on capillary effect to move fluids rather than mechanical pumps in electric vehicles to extend the battery range and life. Partial sintering of copper powders deposited via BJAM was hypothesized to aid capillary effect to improve the heat transfer. Further, BJAM offers the potential for scalability at a production level.

36 MATERIALS SCIENCE↗

Cooling method prolongs life of hot-wire transducer

To cool a hot-wire transducer, the two ends of the wire are supported on thermally and electrically conductive rods, surrounded by a fluid cooling medium. By keeping the supporting rods at a substantially constant temperature, the probe is prevented from overheating.

Baldwin, L. V.↗