Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dry zone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗

Effects of Soiling of Photovoltaic Modules and Systems in Brazil’s Climate Zones

This research presents a methodology for quantifying soiling loss in p-Si and CdTe photovoltaic modules through measurements from soiling stations installed in Belo Horizonte (-19.92° S, -43.99° W), Porto Alegre (-30.05° S, -51.17° W), Brotas de Macaúbas (12.0011° S, -42.6303° W), and Macapá (0.0356° N, -51.0705° W), in Brazil. The electrical parameters measured from photovoltaic modules are compared with precipitation data collected in the same location, with the objective of evaluating the behavior of the soiling ratio during the dry periods. Mathematical models determined the SRatio and SRate for each site (in compliance with the IEC-61324-1 monitoring standard [1]). The SRatio for short-circuit current and maximum power data from the modules were evaluated and compared, characterizing the potential effects of uniform and non-uniform soiling. In addition, a method for analyzing energy-production data of PV systems in order to extract the soiling rate was developed and is presented. The gravimetric soiling densities (mg/m2) was determined using the modeling by Coello and Boyle [2] and these are compared to data collected using the Figgis soiling microscope [3].

climate zone↗

Identification of Water-Saturated Zones in a Protective Hydraulic Earthen Structure by Synchronous Electromagnetic and Seismic Sounding

Results of field experiments in synchronized investigation of the protection embankment of the tailing pond of JSC Kovdor Mining and Processing Plant by means of different wave methods of electromagnetic and seismic sounding are presented. A comparative analysis of the data is carried out by means of which boundaries of zones of different degrees of water saturation of the embankment soils may be reliably established. The ranges of velocity of the electromagnetic wave and range of values of the ratio of the velocities of the longitudinal and transverse elastic wave in the transition from dry dense soil of the embankment to moistened soil right up through water-saturated soil are determined.

42 ENGINEERING↗

DBD plasma-thermal tandem reactors for converting biogas to carbon nanofibers

Sequestering greenhouse gases (CO 2 and CH 4 ) in biogas into carbon nanofibers (CNF) offers a promising route to mitigate carbon emissions and create value-added solid carbon materials. Coupling non-thermal plasma with a thermocatalytic reactor in a tandem setup is a promising approach for tandem reactions of dry reforming of methane to synthesis gas and its subsequent conversion to CNF. Various parameters were studied to determine their effects on CNF growth. Decreasing the total flow rate resulted in an increase in CNF growth. Increasing the plasma power input or the plasma zone length also enhanced the production of CNF. These results illustrate that plasma-thermal tandem reactors can be used to synthesize CNF from biogas with tunable parameters that may be further optimized in future studies.

03 NATURAL GAS↗

The Influence of High Pressure Thermal Behavior on Friction-induced material transfer During Dry Machining of Titanium

In this paper we study failure of coated carbide tools due to thermal loading. The study emphasizes the role assumed by the thermo-physical properties of the tool material in enhancing or preventing mass attrition of the cutting elements within the tool. It is shown that within a comprehensive view of the nature of conduction in the tool zone, thermal conduction is not solely affected by temperature. Rather it is a function of the so called thermodynamic forces. These are the stress, the strain, strain rate, rate of temperature rise, and the temperature gradient. Although that within such consideration description of thermal conduction is non-linear, it is beneficial to employ such a form because it facilitates a full mechanistic understanding of thermal activation of tool wear.

36 MATERIALS SCIENCE↗

Calibrated simulation analysis for integration of evaporative cooling and radiant cooling system for different Indian climatic zones

Radiant cooling system (RCS) has proven to be an energy efficient system for meeting a building's cooling requirements. RCS is energy efficient and provides better thermal comfort compared to conventional all-air heating ventilation air conditioning (HVAC) system. To further improve the efficiency of RCS, a parallel evaporative cooling system (cooling tower) is coupled with RCS and analyzed for different climatic condition using calibrated model. A statistical analysis of weather files (based on wet bulb temperature), was used to identify the availability of useful water for cooling tower integration with RCS. A comprehensive simulation feasibility study of the application of cooling tower in RCS was performed for different cities to cover every climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of different climatic zones, except warm-humid, is suitable for the integration of cooling tower with RCS. An experimental setup was designed and developed for integration of parallel chiller and cooling tower with panel-based RCS for cooling and a dedicated outdoor air system (DOAS) for dehumidification and ventilation. Experiments were conducted for chiller and cooling tower operated RCS in Composite climate of Jaipur, Rajasthan, India. Building Energy Models (BEM) were developed for both the chiller-operated RCS and cooling tower-operated RCS in EnergyPlus and calibrated with the measured data. Using the calibrated models, performance of the system was analyzed for different climatic zones of India. A chiller-operated RCS was considered as a baseline to compare the annual energy saving potential and monthly performance of the cooling tower integrated RCS. Here, in the cooling tower–operated RCS, a total annual savings of 7% in hot and dry climates, 11% in composite climates and 20% in temperate climates was achieved compared to the chiller-operated RCS.

54 ENVIRONMENTAL SCIENCES↗

Multiseasonal and geobotanical approach in remote detection of greisenization areas in the Serra da Pedra Branca Granite, Goias State, Brazil

Multiseasonal analysis of LANDSAT multispectral images in CCT format permitted the mapping of lithologic facies in the Pedra Branca Granite, using geobotanical associations, which occur in the form of variations in the density of cerrado vegetation, as well as the predominance of certain distinctive vegetation species. Dry season images did not show very good results in lithological differentiation due to anomalous illumination conditions related to the low solar elevation and the homogeneity in the vegetation cover, specially the grasses that become dry during this season. Rainy season image, on the other hand, allowed the separation of the lithological types, a fact that can be attributed to a greater differentiation among the geobotanical associations. As a result of this study, the muscovite-granite facies with greisenization zones, which are lithological indicators of important tin mineralization within the Serra da Pedra Branca Granite, were mapped. This methodology can be sucessfully applied to similar known granite bodies elsewhere in the Tin Province of Goias.

Parada, N. D. J.↗

Profitability of Cellulosic Biomass Production in the Northern Great Lakes Region

Producing bioenergy feedstocks on non‐crop land can largely avoid the food price feedbacks of energy biomass production on cropland. The U.S. northern tier grassland‐to‐forest ecotone offers large areas of marginal land that is not currently cropped. In this ecological transition zone, the relative profitability of grassy vs. woody sources of energy biomass is little studied. This paper reports an exploratory investment analysis of cellulosic biomass production in the northern Great Lakes region. It compares two short‐rotation tree crops, willow ( Salix sachalinensis F. Schmidt)and hybrid poplar ( Populus nigra L. X P. maximowiczii A. Henry), and switchgrass ( Panicum virgatum L.) (a native prairie grass) to conventional mixed hay. Because biomass markets are not yet well developed, this study calculates threshold prices and yields at which biomass crops become at least as profitable as mixed grass hay. At 2010–2012 prices and available production technologies, none of the cellulosic crops is competitive with the hay baseline system. The breakeven price of energy biomass ranges from $90–100 per oven‐dry Mg −1 for all three energy crops. Breakeven yields are much more variable, due to the high cost of harvesting woody biomass. At 2010–2012 prices, necessary biomass yield increases range from 3.5‐fold for switchgrass and willow to over 25‐fold for poplar. While the ratio of input costs to revenue remains relatively constant between the northern and southern Great Lakes regions, the opportunity cost of active cropland in the southern zone is much higher, implying an economic comparative advantage for marginal land of the northern tier of the Great Lakes region.

Kells, Bradley J.↗

Ecohydrology of wetland plant communities along an estuarine to tidal river gradient

Abiotic filters that interact with wetland plant communities along tidal–fluvial gradients are highly dynamic, and understanding their quantitative thresholds and relationships to interspecific competition is important during an era of sea-level rise and watershed hydrologic change. Yet, landscape-scale studies of major coastal rivers from the river mouth to the head of tide, such as this study, remain rare. Here, we develop a new predictive framework for estuarine–tidal river research and management using a river-specific low-water datum and the wetland inundation indicator SEVg, the growing-season sum exceedance value of hourly surface-water depth. The distribution and variability of the wetland species pool (n = 203) on the 234 river kilometer (rkm) lower Columbia River and estuary floodplain are described for the first time. 4,940 quadrats at 50 marshes were surveyed (2005–2016). Throughout the estuarine–tidal river system, SEVg was well suited to describe the wetland inundation regime and its variability based on the combination of longitudinal river position and elevation. SEVg increased significantly landward. Two primary wetland inundation regimes were identified: the seaward-tidal, usually greatest during the winter months, and landward-fluvial, greatest during the growing season. Nearest the ocean, salinity is the abiotic factor limiting species richness and non-native species. Farther upriver, the daily, seasonal, and interannual variability of the wetting and drying cycle encourage disturbance-tolerant species and non-natives and limit the number of hydrophytes and total vegetative cover. Hence, the average between-year similarity of site-scale areal cover significantly decreased landward. Hierarchical cluster analysis indicated five vegetative groups and five ecohydrologic zones between rkm 0 and 234 were discriminated with 76 significant species–zone associations. All zones had unique indicator species. Species with high indicator values were Carex lyngbyei throughout the estuarine zones, and Eleocharis palustris, Sagittaria latifolia, and the invasive non-native Phalaris arundinacea in the upper estuarine and lower, middle, and upper tidal river zones (IV > 0.90). Competition from C. lyngbyei nearest the ocean and P. arundinacea in the tidal river was associated with reduced species richness when total cover was >65%. This framework of filters informs the design and prediction of future wetland plant communities on coastal river floodplains.

54 ENVIRONMENTAL SCIENCES↗

Occupant Perceptions and a Health Outcome in Retail Stores

Indoor Environmental Quality (IEQ) in commercial buildings, such as retail stores, can affect employee satisfaction, productivity, and health. This study administered an IEQ survey to retail employees and found correlations between measured IEQ parameters and the survey responses. The survey included 611 employees in 14 retail stores located in Pennsylvania (climate zone 5A) and Texas (climate zone 2A). The survey questionnaire featured ratings of different aspects of IEQ, including thermal comfort, lighting and noise level, indoor smells, overall cleanness, and environmental quality. Simultaneously with the survey, on-site physical measurements were taken to collect data of relative humidity levels, air exchange rates, dry bulb temperatures, and contaminant concentrations. This data was analyzed using multinomial logit regression with independent variables being the measured IEQ parameters, employees’ gender, and age. This study found that employee perception of stuffy smells is related to formaldehyde and PM10 concentrations. Furthermore, the survey also asked the employees to report an annual frequency of common colds as a health indicator. The regression analysis showed that the cold frequency statistically correlates with the measured air exchange rates, outdoor temperatures, and indoor PM concentrations. Overall, the air exchange rate is the most influential parameter on the employee perception of the overall environmental quality and self-reported health outcome.

Field study↗

The SURE House (Solar Decathlon 2015)

Coastal towns and cities across the Northeastern US, with their high population density, aged utility infrastructure, and unique geography, are increasingly vulnerable to climate change related storm events. In October 2012 superstorm Sandy highlighted the fragility of our current coastal building types and made clear the need for a new model of design and construction which works to understand and mitigate these weaknesses. Dramatic changes in public policy, championed by both The Federal Emergency Management Agency (FEMA) and the National Flood Insurance Program (NFIP) are driving the rebuilding of these shore communities, often resulting in costly renovations, un-sustainable neighborhood configurations and in direct conflict with concurrent government policies such as The American with Disabilities Act (ADA). The SURE HOUSE demonstrates a series of new design solutions to these conflicting public policies and environmental imperatives. At Stevens Institute of Technology, the 2015 Solar Decathlon started with the challenge: Can we design a home for coastal New Jersey that dramatically reduces its energy use while protecting itself from the realities of a changing, more extreme climate? The SURE HOUSE merges the iconic 20th century shore home with 21st century building science. Utilizing innovative renewable energy technologies, a ‘Passive House’ level building envelope, and rugged glass-fiber-composite materials to flood-proof the home, the SURE HOUSE is a high-performance, net-zero-energy home, armored against extreme weather, designed for the contemporary lifestyle of the Jersey Shore and other vulnerable coastal communities. SUSTAINABLE At Stevens, we recognize that energy use in the home and workplace is directly connected to the growing problem of climate change. Reducing our energy consumption by designing higher performing, compact homes that are both functional, comfortable and desirable is the first critical step towards a modern, sustainable architecture for New Jersey and beyond. This is what informed the architectural design of the house. Configured about a compact form, thickly insulated and air-sealed walls eliminate thermal bridging and minimize energy losses while advanced glazing brings in free solar heat during the winter months. As a result of these passive design strategies, the SURE HOUSE has a greatly reduced carbon footprint requiring 91% less energy than a typical New Jersey home. Photovoltaic (PV) arrays on both the rooftop and operable shutters easily provide energy in excess of the home’s modest demands. The Stevens team considers a truly sustainable home in the era of climate change, one that prioritizes low energy use, and integrates right-sized renewable generation to supply the home’s needs. Low consumption, low production. RESILIENT In October of 2012, Hurricane Sandy wreaked havoc along the east coast of the US. In New Jersey alone there was an estimated 29.4 billion dollars in damages, 346,000 homes affected, and almost two and a half million people left without power, in some cases for over 10 days. Recovery from this storm and associated flooding is ongoing to this day, as many New Jersey homeowners grapple with the large costs of rebuilding and struggle to adapt to complicated new home building regulations. Damage from this storm to Hoboken, the home of the Stevens Institute of Technology’s campus, and to the New Jersey shore was extensive and many students on the SURE HOUSE team were directly affected by this historic event. The Stevens design team recognizes that in a world of more frequent and stronger storms, the ability to absorb and adapt to change is more important than ever. Successfully weathering the next storm and its aftermath is one of the primary goals in the design of the SURE HOUSE prototype. The SURE HOUSE introduces unique ‘dry flood-proofing’ methods to residential construction. Innovative wall and floor flood-proofing, utilizing durable composite sheathing materials adapted from the boating industry, were developed by the student team to render the SURE House’s building envelope flood proof up to the FEMA AE 6/7 Zone (+ 6/7 feet of water above sea-level). Designed and fabricated utilizing glass-fiber composite materials, the custom storm shutter system serves to protect the large glazed openings of the home from both air-borne debris impact and water infiltration during a storm event while also providing deterrence from the vandalism that often occurs in the aftermath of a calamitous event. During extended power outages, a ‘resilient’ solar array is capable of supplying critical amounts of energy and hot water to the home, without the use of battery storage or grid infrastructure. PV Description AC GRID-TIED PV SYSTEM The SURE HOUSE solar system consists of two distinct arrays, the grid-tied rooftop array which produces AC Powerand the shutter-mounted array which converts DC power generated by the modules directly into usable heat for the domestic hot water (DHW). The roof-mounted AC grid-tied array is comprised of three strings, two 11 module strings connected to an SMA SB 5000TL-US-223 inverter and a single 10 module string equipped and an SMA SB 3000TL-US-22 central inverter. All modules for the rooftop AC array are LG MonoX 2804 watt solar panels, chosen for their durability and efficiency. Inverter sizing and string size are optimized to the electrical characteristics of the chosen PV modules and the desired energy production, see Appendix 5B. The SURE HOUSE is projected to produce 12,353 kWh per year to meet 6,157 kWh per year of estimated consumption. Solar modules for the two AC grid-tied sub arrays are mounted on the main roof surface of the SURE HOUSE with a 10 degree tilt angle using a partially-ballasted polyethylene roof mounting system made by Renusol, which is particularly suited to the corrosive salt air of a coastal environment. This method was chosen for its installation simplicity and to limit detrimental roof penetrations. The 10 degree tilt optimizes the energy generated per roof area at a lower price, see Appendix 5A, and ensures that there is minimal wind uplift. DC SOLAR ELECTRIC DOMESTIC HOT WATER The SURE HOUSE’s approach to sustainable and resilient domestic hot water (DHW) consists of a unique, custom engineered DC solar electric hot water system. Employing the use of Advanced Energy’s DC electric PV heater (DCPVH)5 to heat domestic water well beyond the draw temperature, the SURE HOUSE is able to obtain a remarkably high solar fraction of 75% or more. The custom modified 80 gallon Vaughn DHW tank acts as a large solar ‘battery’ that stores heat energy in the form of hot water at almost 150 degrees, harvesting energy when the sun is out for use later in the day or overnight. The system, which uses electricity rather than heated fluid, is distinct from traditional ‘solar thermal’ systems by eliminating the dangers and associated maintenance issues of fluid based systems. By forgoing the use of external fluid loops, overheated solar collectors and pipes are not an issue for the SURE HOUSE system which never needs any yearly or seasonal flushing. In weather conditions where the integrated DCPVH unit cannot produce enough hot water via solar energy alone, the Vaughn hot water tank comes factory made with an AC powered 2.6 COP heat pump and a AC heating coil that serve as back-up heating elements. The DCPVH is powered by a DC array consisting of 10 custom-made Solbian by PVilion 180 watt, monocrystalline, flexible solar modules6. The Solbian modules are directly mounted to the top half of the operable storm shutters on the south façade of the SURE HOUSE. The SURE HOUSE team worked closely with PVillion, a PV system designer specializing in flexible architectural photovoltaics, to design an adhesive system that works with the glass-fiber storm shutter surface in a reliable manner over an extended period. Because this system operates in DC-only mode and never connects to the municipal power grid, the system can continue to create hot water safely and effectively even during grid disruption events. This hot water, and the energy stored within it, could be used for a range of activities including washing and cooking to more elaborate hydronic heating systems as desired. See Appendix 6 for system engineering, sizing and modeling.

14 SOLAR ENERGY↗

High-Resolution Computed Tomography Dataset of Mount Simon Sandstone

The Illinois Basin is a critical structure for subsurface energy related activities and their implementation in the United States. The Mount Simon Sandstone has been identified as a storage target for permanent and transient storage of fluids in the basin. Known for its exceptional thickness, depth, porosity, and sealing properties of overlying formations, this saline reservoir is crucial for long-term subsurface energy efforts. We present an extensive Computed Tomography (CT) dataset on a high porosity and permeability zone in the lower Mount Simon Sandstone available on the Energy Data eXchange® (EDX). This publicly accessible database comprises over 500 GB of high-resolution CT scans of six core samples, with resolutions ranging from 14.8 µm to 0.7 µm per pixel. The scans include both dry sandstone samples and those saturated with multiple fluids, allowing for comparative analyses across different conditions and resolutions. Coarser scans capture the bedding structure of the sandstone, while finer resolutions reveal detailed pore infill and throat characteristics. Metadata on location, depth, and saturation state enhance usability, enabling quick identification and cross-sample comparisons. By providing a robust resource for research and collaboration, the database contributes to domestic energy advancement by supporting continued progress in the use of the subsurface for energy solutions.

characterization↗

A deep insight on the coal ash-to-slag transformation behavior during the entrained flow gasification process

Recent research provided deep insight on the coal ash-to-slag transformation characterization during the entrained flow gasification process, with experimentation on a 40 kg/hr (dry basis) coal-fed opposed multi-burner (OMB) entrained flow gasifier and simulation via FactSage™ software. A general mechanism is presented to relate the gasifier design temperature, ash fluid temperature, and operating temperature with the degree of the slag polymerization. The change of the high temperature zone, the corresponding particle residence time in the high temperature zone, and syngas composition have obvious effects on the slag mineral transformation behavior. Mineral types formed on the wall of the gasifier chamber were mainly anorthite (CaAl 2 Si 2 O 8 ), aluminum oxide (Al 2 O 3 ), and calcium sulfide (CaS). These minerals transformed to anorthite and diopside (CaMgSi 2 O 6 ) at the slag hole zone, while the minerals at the lock hopper were anorthite, orthoclase (KAlSi 3 O 8 ), quartz (SiO 2 ), gypsum (CaSO 4 ), calcite (CaCO 3 ), and halite (NaCl). FactSage™ predicted minerals as anorthite, diopside, orthoclase, and albite (NaAlSi 3 O 8 ), etc., where the slag temperature was below the ash fluid temperature and when the ratios of CO/CO 2 and (CO + H 2 )/CO 2 were lower than 1.0 and 2.0, respectively. By simulation, residual carbon was found to be the dominant factor over syngas composition to cause mineral transformation, and this was verified experimentally. The Ca-based crystals, typically anorthite, was shifted to diopside, near the slag hole zone, and a linear relationship was found between the content ratios of diopside/(anorthite + diopside), CaO/SiO 2 , and (CaO + MgO)/SiO 2 . A dimensionless number, θ, was defined to characterize the changing chemical composition and the degree of slag polymerization, with temperature deviation from the design condition. Three zones of θ were identified and related to the deviation between the actual gasification condition from the design condition. Finally, a low slag polymerization degree corresponded with a higher temperature deviation between the actual condition and design condition, and this proved that increased residual carbon content and changing iron valence state increased the mineral types when the slag temperature was below the ash fluid temperature.

01 COAL, LIGNITE, AND PEAT↗

Results of stainless steel canister corrosion studies and environmental sample investigations

This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters. At both sites, the surface dust could be divided into fractions generated by manufacturing processes and by natural processes. The fraction from manufacturing processes consisted of variably-oxidized angular and spherical particles of stainless steel and iron, generated by machining and welding/cutting processes, respectively. Dust from natural sources consisted largely of detrital quartz and aluminosilicates (feldspars and clays) at both sites. At Hope Creek, soluble salts were dominated by sulfates and nitrates, mostly of calcium. Chloride was a trace component and the only chloride mineral observed by SEM was NaCl. Chloride surface loads measured by the Saltsmart™ sensors were very low, less than 60 mg m –2 on the canister top, and less than 10 mg m –2 on the canister sides. At Diablo Canyon, sea-salt aggregates of NaCl and Mg-SO 4 , with minor K and Ca, were abundant in the dust, in some cases dominating the observed dust assemblage. Measured Saltsmart™ chloride surface loads were very low (<5 mg m –2 ); however, high canister surface temperatures damaged the Saltsmart™ sensors, and, in view of the SEM observations of abundant sea-salts on the package surfaces, the measured surface loads may not be valid. Moreover, the more heavily-loaded canister tops at Diablo Canyon were not sampled with the Saltsmart™ sensors. The observed low surface loads do not preclude chloride-induced stress corrosion cracking (CISCC) at either site, because (1) the measured data may not be valid for the Diablo Canyon canisters; (2) the surface coverage was not complete (for instance, the 45º offset between the outlet and inlet vents means that near-inlet areas, likely to have heavier dust and salt loads, were not sampled); and (3) CISCC has been experimentally been observed at salt loads as low as 5-8 mg/m 2 . Experimental efforts at SNL to assess corrosion of interim storage canister materials include three tasks in FY14. First, a full-diameter canister mockup, made using materials and techniques identical to those used to make interim storage canisters, was designed and ordered from Ranor Inc., a cask vendor for Areva/TN. The mockup will be delivered prior to the end of FY14, and will be used for evaluating weld residual stresses and degrees of sensitization for typical interim storage canister welds. Following weld characterization, the mockup will be sectioned and provided to participating organizations for corrosion testing purposes. A test plan is being developed for these efforts. In a second task, experimental work was carried out to evaluate crevice corrosion of 304SS in the presence of limited reactants, as would be present on a dustcovered storage canister. This work tests the theory that limited salt loads will limit corrosion penetration over time, and is a continuation of work carried out in FY13. Laser confocal microscopy was utilized to assess the volume and depth of corrosion pits formed during the crevice corrosion tests. Results indicate that for the duration of the current experiments (100 days), no stifling of corrosion occurred due to limitations in the amount of reactants present at three different salt loadings. Finally, work has been carried out this year perfecting an instrument for depositing sea-salts onto metal surfaces for atmospheric corrosion testing purposes. The system uses an X-Y plotter system with a commercial airbrush, and deposition is monitored with a quartz crystal microbalance. The system is capable of depositing very even salt loadings, even at very low total deposition rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigations of ash fouling with cattle wastes as reburn fuel in a small-scale boiler burner under transient conditions

Fouling behavior under reburn conditions was investigated with cattle wastes (termed as feedlot biomass, FB) and coal as reburn fuels under a transient condition and short-time operation. A small-scale (30 kW or 100,000 Btu/hr) boiler burner research facility was used for the reburn experiments. The fuels considered for these experiments were natural gas (NG) for the ashless case, pure coal, pure FB, and blends of coal and FB. Two parameters that were used to characterize the ash 'fouling' were (1) the overall heat-transfer coefficient (OHTC) when burning NG and solid fuels as reburn fuels, and (2) the combustible loss through ash deposited on the surfaces of heat exchanger tubes and the bottom ash in the ash port. A new methodology is presented for determining ash fouling behavior under transient conditions. Results on the OHTCs for solid reburn fuels are compared with the OHTCs for NG. It was found that the growth of the layer of ash depositions over longer periods typically lowers OHTC, and the increased concentration of ash in gas phase promotes radiation in high-temperature zones during initial periods while decreasing the heat transfer in low-temperature zones. The ash analyses indicated that the bottom ash in the ash port contained a smaller percentage of combustibles with a higher FB percentage in the fuels, indicating better performance compared with coal because small particles in FB burn faster and the FB has higher volatile matter on a dry ash-free basis promoting more burn out. 16 refs., 12 figs., 6 tabs.

01 COAL, LIGNITE, AND PEAT↗

Advanced dry head-end reprocessing of light water reactor spent nuclear fuel

A method for reprocessing spent nuclear fuel from a light water reactor includes the step of reacting spent nuclear fuel in a voloxidation vessel with an oxidizing gas having nitrogen dioxide and oxygen for a period sufficient to generate a solid oxidation product of the spent nuclear fuel. The reacting step includes the step of reacting, in a first zone of the voloxidation vessel, spent nuclear fuel with the oxidizing gas at a temperature ranging from 200-450.degree. C. to form an oxidized reaction product, and regenerating nitrogen dioxide, in a second zone of the voloxidation vessel, by reacting oxidizing gas comprising nitrogen monoxide and oxygen at a temperature ranging from 0-80.degree. C. The first zone and the second zone can be separate. A voloxidation system is also disclosed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced dry head-end reprocessing of light water reactor spent nuclear fuel

A method for reprocessing spent nuclear fuel from a light water reactor includes the step of reacting spent nuclear fuel in a voloxidation vessel with an oxidizing gas having nitrogen dioxide and oxygen for a period sufficient to generate a solid oxidation product of the spent nuclear fuel. The reacting step includes the step of reacting, in a first zone of the voloxidation vessel, spent nuclear fuel with the oxidizing gas at a temperature ranging from 200-450.degree. C. to form an oxidized reaction product, and regenerating nitrogen dioxide, in a second zone of the voloxidation vessel, by reacting oxidizing gas comprising nitrogen monoxide and oxygen at a temperature ranging from 0-80.degree. C. The first zone and the second zone can be separate. A voloxidation system is also disclosed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗