Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

M-BAND Analysis of Chromosome Aberration In Human Epithelial Cells exposed to Gamma-ray and Secondary Neutrons of Low Dose Rate

High-energy secondary neutrons, produced by the interaction of galactic cosmic rays with the atmosphere, spacecraft structure and planetary surfaces, contribute to a significant fraction to the dose equivalent in crew members and passengers during commercial aviation travel, and astronauts in space missions. The Los Alamos Nuclear Science Center (LANSCE) neutron facility's "30L" beam line is known to generate neutrons that simulate the secondary neutron spectrum of the Earth's atmosphere at high altitude. The neutron spectrum is also similar to that measured onboard spacecraft like the MIR and the International Space Station (ISS). To evaluate the biological damage, we exposed human epithelial cells in vitro to the LANSCE neutron beams at an entrance dose rate of 2.5 cGy/hr or gamma-ray at 1.7cGy/hr, and assessed the induction of chromosome aberrations that were identified with mBAND. With this technique, individually painted chromosomal bands on one chromosome allowed the identification of inter-chromosomal aberrations (translocation to unpainted chromosomes) and intra-chromosomal aberrations (inversions and deletions within a single painted chromosome). Compared to our previous results for gamma-rays and 600 MeV/nucleon Fe ions of high dose rate, the neutron data showed a higher frequency of chromosome aberrations. However, detailed analysis of the inversion type revealed that all of the three radiation types in the study induced a low incidence of simple inversions. The low dose rate gamma-rays induced a lower frequency of chromosome aberrations than high dose rate gamma-rays, but the inversion spectrum was similar for the same cytotoxic effect. The distribution of damage sites on chromosome 3 for different radiation types will also be discussed.

Hada, M.↗

Chromosomal instability induced by heavy ion irradiation

PURPOSE: To establish the dose-response relationship for the induction of chromosomal instability in GM10115 cells exposed to high-energy iron ions (1 GeV/nucleon, mean LET 146 keV/microm) and gold ions (11 GeV/nucleon, mean LET 1450 keV/microm). Past work has established that sparsely ionizing X-rays can induce a long-lived destabilization of chromosomes in a dose-dependent manner at an incidence of approximately 3% per gray. The present investigation assesses the capacity of High-Z and High-energy (HZE) particles to elicit this same endpoint. MATERIALS AND METHODS: Clonal populations derived from single progenitor cells surviving heavy-ion irradiation were analyzed cytogenetically to identify those clones showing a persistent destablization of chromosomes. RESULTS: Dose-response data, with a particular emphasis at low dose (< 1.0 Gy), indicate a frequency of approximately 4% per gray for the induction of chromosomal instability in clones derived from single progenitor cells surviving exposure to iron ions. The induction of chromosomal instability by gold ions was, however, less responsive to applied dose, as the observed incidence of this phenotype varied from 0 to 10% over 1-8 Gy. Both iron and gold ions gave dose-dependent increases in the yield of chromosomal aberrations (both chromosome- and chromatid-type) measured at the first mitosis following irradiation, as well as shoulderless survival curves having D0=0.87 and 1.1 Gy respectively. CONCLUSIONS: Based on the present dose-response data, the relative biological effectiveness of iron ions is 1.3 for the induction of chromosomal instability, and this indicates that heavy ions are only slightly more efficient than X-rays at eliciting this delayed phenotype.

Non-NASA Center↗

State of the art, gaps, and prospects in fusion materials theory and modelling

Advancing the theory and simulation of materials for fusion applications remains a key component of global roadmaps aimed at delivering much-needed fusion power. Especially as the drive for commercial application increases, prototypes must be designed against radiation damage before the relevant experimental data can be collected and cost reductions that are possible by testing materials in silico become even more important. Here, we summarise the state of the art as it emerged during the 7 th Fusion Materials Theory & Modelling Workshop that took place in 2024, with the aim to highlight present gaps and future directions for the fusion materials modelling community. Of particular interest were the effects of transmutations, chemical complexity with the development of novel alloys and interatomic potentials, advancements in modelling high-dose microstructures, comparison with experimental data and multiscale models for structural assessment relying on high-performance computing and virtual reality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surrogate modeling of Monte Carlo radiation transport with convolutional neural networks for shielding optimization

Here, we present a machine learning (ML)-based surrogate model using convolutional neural networks (CNN) designed to emulate the attenuation of neutron fields as they pass through various shielding materials. This model can compute the outgoing neutron flux almost instantaneously and achieves reasonable accuracy compared to traditional Monte Carlo (MC)-based codes, which are computationally intensive. This emulator alleviates the complexity of neutron radiation transport through shielding materials by reducing the dimensionality and enables shielding optimization for a known radiation environment. This optimization process, which would have taken an unrealistic timeline due to several complex radiation transport simulations, can now be achieved in minutes, thus increasing computational capabilities in radiation shielding assessment. We demonstrate the applications of this emulator in computing effective dose rates and optimizing shielding solutions for a heavy-ion accelerator facility, such as the Facility for Rare Isotope Beams, where secondary neutrons produced via beam interactions dominate the radiation environment.

accelerator shielding↗

Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice

Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CarcSeq Measurement of Rat Mammary Cancer Driver Mutations and Relation to Spontaneous Mammary Neoplasia

Abstract The ability to deduce carcinogenic potential from subchronic, repeat dose rodent studies would constitute a major advance in chemical safety assessment and drug development. This study investigated an error-corrected NGS method (CarcSeq) for quantifying cancer driver mutations (CDMs) and deriving a metric of clonal expansion predictive of future neoplastic potential. CarcSeq was designed to interrogate subsets of amplicons encompassing hotspot CDMs applicable to a variety of cancers. Previously, normal human breast DNA was analyzed by CarcSeq and metrics based on mammary-specific CDMs were correlated with tissue donor age, a surrogate of breast cancer risk. Here we report development of parallel methodologies for rat. The utility of the rat CarcSeq method for predicting neoplastic potential was investigated by analyzing mammary tissue of 16-week-old untreated rats with known differences in spontaneous mammary neoplasia (Fischer 344, Wistar Han, and Sprague Dawley). Hundreds of mutants with mutant fractions ≥ 10−4 were quantified in each strain, most were recurrent mutations, and 42.5% of the nonsynonymous mutations have human homologs. Mutants in the mammary-specific target of the most tumor-sensitive strain (Sprague Dawley) showed the greatest nonsynonymous/synonymous mutation ratio, indicative of positive selection consistent with clonal expansion. For the mammary-specific target (Hras, Pik3ca, and Tp53 amplicons), median absolute deviation correlated with percentages of rats that develop spontaneous mammary neoplasia at 104 weeks (Pearson r = 1.0000, 1-tailed p = .0010). Therefore, this study produced evidence CarcSeq analysis of spontaneously occurring CDMs can be used to derive an early metric of clonal expansion relatable to long-term neoplastic outcome.

McKim, Karen L.↗

Benchmark solutions for the galactic ion transport equations: Energy and spatially dependent problems

Nontrivial benchmark solutions are developed for the galactic ion transport (GIT) equations in the straight-ahead approximation. These equations are used to predict potential radiation hazards in the upper atmosphere and in space. Two levels of difficulty are considered: (1) energy independent, and (2) spatially independent. The analysis emphasizes analytical methods never before applied to the GIT equations. Most of the representations derived have been numerically implemented and compared to more approximate calculations. Accurate ion fluxes are obtained (3 to 5 digits) for nontrivial sources. For monoenergetic beams, both accurate doses and fluxes are found. The benchmarks presented are useful in assessing the accuracy of transport algorithms designed to accommodate more complex radiation protection problems. In addition, these solutions can provide fast and accurate assessments of relatively simple shield configurations.

Ganapol, Barry D.↗

Different reactivity to angiotensin II of peripheral and renal arteries in spontaneously hypertensive rats: effect of acute and chronic angiotensin converting enzyme inhibition

We assessed renal blood flow and pressor responses to graded angiotensin II doses in spontaneously hypertensive (SHR) and Wistar-Kyoto (WKY) rats ingesting a diet containing 1.6% sodium basally and after acute and chronic angiotensin converting enzyme (ACE) inhibition with captopril. In the basal state the pressor response to angiotensin II was enhanced (P<0.0005) and the renal vascular response was blunted (P<0.005) in SHR compared with WKY rats. After acute captopril administration the pressor response was enhanced in both strains, and the difference between them was maintained, while the renal vascular response was enhanced in both, but more in SHR, so that the renal vascular response in the SHR became larger than in WKY (P<0.0001). Chronic captopril treatment blunted both pressor and renal responses in WKY rats, but only the pressor response in SHR. The renal vessels of SHR seem to be different from those of WKY rats in reaction to exogenous angiotensin II, and in response to both acute administration of captopril (probably acting through blockade of angiotensin II production) and chronic administration of captopril (probably acting mainly through accumulation of kinin or production of prostaglandins).

NASA Discipline Number 21-50↗

Chemical Reactivity of In-Situ Lunar Dust for Biotoxicity Assessment

How does the chemical reactivity of in-situ lunar dust compare to Apollo samples currently stored in curation facilities here on Earth? Essential investigations of this question will help us to further mitigate exploration risks for future human explorers on the Moon and will also provide critical information for astrobiologists and space biologists using the Moon for scientific inquiry. Apollo 14 dust biotoxicity studies, carried out by the NASA Lunar Airborne Dust Toxicity Assessment Group (LADTAG), included numerous cellular and animal experiments. Intratracheal instillation and inhalation studies in rats both showed Apollo 14 dust to be intermediate in toxicity compared to low-tox titanium dusts and high-tox quartz dusts of similar particle sizes. The collective results were used in models to establish a safe exposure limit for astronauts. Although LADTAG took extensive steps to preserve what chemical reactivity may still have existed in the samples, it is simply unknown if they possessed true in-situ chemical reactivity or if that reactivity has decayed. Initial gas loss on collection and other alterations, and even intermittent exposure to Earth-normal conditions during subsequent decades of handling, obscure a forensic reconstruction of the initial state. Because a mineral dust’s chemical reactivity influences its biotoxicity, researchers have developed methods to “activate” lunar dust and simulants. Past studies that modeled impact processes and radiation in the lunar environment suggest that in-situ lunar dust is likely to be more chemically reactive than Earth-exposed samples. Because of these results, in-situ measurements are warranted. Since the lunar surface is heterogeneous, dust biotoxicity is expected to vary from site to site due to particle size, mineralogy, physical characteristics, degree of space weathering, and chemical reactivity. This circumstance dictates dust assessments at a suite of lunar sites enabled by CLPS opportunities. Dose, location, and duration of particle exposure will also affect biological responses. In-situ chemical reactivity measurements can inform cross-cutting collaborative research campaigns such as astrobiology studies examining regolith interactions with organisms and its ability to preserve chemical and structural biomarkers, as well as space biology investigations that examine regolith-microbe interactions relating to life support systems, plant growth, biomining, and development of regolith biocomposites.

Jon C Rask↗

Decommissioning of the V1 Nuclear Power Plant Jaslovske Bohunice - 20270

The paper focuses on introducing the approach and method applied for decommissioning of the V1 nuclear power plant (further the 'V1 NPP') located in Jaslovske Bohunice in the Slovak Republic, to the conference participants. The Paper outlines activities and steps necessary to comply with the requirements contained in the decision of the Slovak government from 1999 regarding the early shutdown of the V1 NPP. The company responsible for the V1 NPP decommissioning is Jadrova a vyradovacia spolocnost, a.s., (further JAVYS) with the State as a sole shareholder. On the basis of the V1 NPP Decommissioning Conceptual Plan, out of four assessed options, JAVYS selected the immediate decommissioning option (the 'IDO') for the V1 NPP. On the basis of multi-criteria analysis, the IDO specified the approach of immediate and continuous dismantling of equipment followed by demolition of buildings and preparation of the site for its further potential use. The IDO also included the summary of technical, environmental, legislative information as well as the determination of assumed costs for decommissioning of the V1 NPP. Prior to commencement of the V1 NPP decommissioning, within the process of termination of operation, activities connected with de-fuelling, monitoring, processing of historical waste and, not to forget, the process of obtaining the license for the V1 NPP decommissioning were executed. JAVYS decided to divide the decommissioning process into two stages. In 2011, JAVYS obtained a license for the first stage of the V1 NPP decommissioning. Within this stage, dismantling of inactive equipment, demolitions of inactive buildings, monitoring of systems and preparatory works for the upcoming stage of decommissioning were implemented. In 2015, in line with the license for the 2. stage of the V1 NPP decommissioning, the activities of decontamination and dismantling of contaminated and active equipment as well as demolitions of remaining buildings began. In this stage radioactive waste (RAW) produced during the decommissioning is to be processed. After decontamination, the material fulfilling the free release criteria is to be released into the environment, the site is to be cleared from the scope of the Atomic Act and released from the surveillance of the national regulators. Future application of certain methods and techniques for decontamination and dismantling in similar environments might bring an added value to the operators. Paper includes a description of best practices for Nuclear Power Plant VVER type reactors decommissioning. Schedule comparison is given to show how the critical path of certain projects is being managed. Application of the International Standard for Decommissioning Costing (ISDC) methodology provides a uniform method which enables comparison of cost estimates to other nuclear facilities under decommissioning. The cost estimate for the V1 NPP decommissioning has been continuously updated based on more advanced and detailed information on the decommissioning activities and projects. Monitoring of progress of the V1 NPP decommissioning is performed via four key-performance indicators. The Earned Value Management (EVM) methodology is used for evaluating time and cost aspect of decommissioning activities while waste conditioning index is calculated by comparing the actually produced waste to planned values of waste for a respective monitored period. Radiological safety index is assessed by comparison of the personnel records on the individual yearly doses received by each respective employee to the boundary value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Calibrated Sodium Data for Preliminary Validation of the SRT Code for Advanced Reactors

Various types of non-light water reactors are currently engaged in the U.S. licensing process. Because of inherent differences compared with well-established large light water reactors, appropriate assessment tools are needed. Specifically, source term analysis, which determines environmental dose impacts from potential accident scenarios, is a crucial part of design and licensing. The U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic source term analysis for advanced reactor deployments. To align with these needs, Argonne National Laboratory has developed the Simplified Radionuclide Transport (SRT) source term analysis code for metal fuel Sodium-cooled Fast Reactors (SFRs) and microreactors. SRT conducts time-dependent radionuclide transport and retention in SFRs for core and ex-core radionuclide source accident sequences. The main objective of SRT is to provide rapid sensitivity and uncertainty analyses, incorporating parametric uncertainties and summarizing probabilistic results. As part of the code validation process, a study focused on the bubble scrubbing module was performed using an experiment recently carried out by the University of Wisconsin-Madison. Based on the analysis, the modeling approach in SRT provides accurate results for small and large aerosols, while slight underprediction of radionuclide aerosol removal are observed for medium sized aerosols. However, the deviation is minor, considering the highly uncertain phenomenon and range of results, and is in the conservative direction. In addition, uncertainty information derived from the experiments is further implemented, reflecting the actual span of parameters, which leads to enhanced agreement with code predictions. The results demonstrate that SRT provides reasonable predictions for the bubble scrubbing process in sodium pool.

Kam, Dong Hoon↗

FRMAC Assessment Manual Volume 1 (Overview and Methods)

The Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual is the tool used to organize and guide activities of the FRMAC Assessment Division. The mission of the FRMAC Assessment Division in a radiological emergency is to interpret radiological data and predict worker and public doses. This information is used by Decision Makers to recommend protective actions in accordance with Protection Action Guides (PAGs) issued by government agencies. This manual integrates many health physics tools and techniques used to make these assessments.

54 ENVIRONMENTAL SCIENCES↗

Probabilistic Assessment of Cancer Risk for Astronauts on Lunar Missions

During future lunar missions, exposure to solar particle events (SPEs) is a major safety concern for crew members during extra-vehicular activities (EVAs) on the lunar surface or Earth-to-moon transit. NASA s new lunar program anticipates that up to 15% of crew time may be on EVA, with minimal radiation shielding. For the operational challenge to respond to events of unknown size and duration, a probabilistic risk assessment approach is essential for mission planning and design. Using the historical database of proton measurements during the past 5 solar cycles, a typical hazard function for SPE occurrence was defined using a non-homogeneous Poisson model as a function of time within a non-specific future solar cycle of 4000 days duration. Distributions ranging from the 5th to 95th percentile of particle fluences for a specified mission period were simulated. Organ doses corresponding to particle fluences at the median and at the 95th percentile for a specified mission period were assessed using NASA s baryon transport model, BRYNTRN. The cancer fatality risk for astronauts as functions of age, gender, and solar cycle activity were then analyzed. The probability of exceeding the NASA 30- day limit of blood forming organ (BFO) dose inside a typical spacecraft was calculated. Future work will involve using this probabilistic risk assessment approach to SPE forecasting, combined with a probabilistic approach to the radiobiological factors that contribute to the uncertainties in projecting cancer risks.

Kim, Myung-Hee Y.↗

Effects of 14 days of head-down tilt bed rest on cutaneous vasoconstrictor responses in humans

This study tested the hypothesis that head-down tilt bed rest (HDBR) reduces adrenergic and nonadrenergic cutaneous vasoconstrictor responsiveness. Additionally, an exercise countermeasure group was included to identify whether exercise during bed rest might counteract any vasoconstrictor deficits that arose during HDBR. Twenty-two subjects underwent 14 days of strict 6 degrees HDBR. Eight of these 22 subjects did not exercise during HDBR, while 14 of these subjects exercised on a supine cycle ergometer for 90 min a day at 75% of pre-bed rest heart rate maximum. To assess alpha-adrenergic vasoconstrictor responsiveness, intradermal microdialysis was used to locally administer norepinephrine (NE), while forearm skin blood flow (SkBF; laser-Doppler flowmetry) was monitored over microdialysis membranes. Nonlinear regression modeling was used to identify the effective drug concentration that caused 50% of the cutaneous vasoconstrictor response (EC(50)) and minimum values from the SkBF-NE dose-response curves. In addition, the effects of HDBR on nonadrenergic cutaneous vasoconstriction were assessed via the venoarteriolar response of the forearm and leg. HDBR did not alter EC(50) or the magnitude of cutaneous vasoconstriction to exogenous NE administration regardless of whether the subjects exercised during HDBR. Moreover, HDBR did not alter the forearm venoarteriolar response in either the control or exercise groups during HDBR. However, HDBR significantly reduced the magnitude of cutaneous vasoconstriction due to the venoarteriolar response in the leg, and this response was similarly reduced in the exercise group. These data suggest that HDBR does not alter cutaneous vasoconstrictor responses to exogenous NE administration, whereas cutaneous vasoconstriction of the leg due to the venoarteriolar response is reduced after HDBR. It remains unclear whether attenuated venoarteriolar responses in the lower limbs contribute to reduced orthostatic tolerance after bed rest and spaceflight.

NASA Discipline Cardiopulmonary↗

A Multi-Institutional Phase 2 Trial of High-Dose SAbR for Prostate Cancer Using Rectal Spacer

High-dose SABR for prostate cancer offers the radiobiologic potency of the most intensified radiation therapy regimens but was associated with >90% rates of ulceration of the anterior rectal wall on endoscopic assessment; this infrequently progressed to severe rectal toxicity in prior prospective series. A multi-institutional phase 2 prospective trial was conducted to assess whether placement of a perirectal hydrogel spacer would reduce acute periprostatic rectal ulcer events after high-dose (>40 Gy) SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future directions for LDEF ionizing radiation modeling and assessments

A calculational program utilizing data from radiation dosimetry measurements aboard the Long Duration Exposure Facility (LDEF) satellite to reduce the uncertainties in current models defining the ionizing radiation environment is in progress. Most of the effort to date has been on using LDEF radiation dose measurements to evaluate models defining the geomagnetically trapped radiation, which has provided results applicable to radiation design assessments being performed for Space Station Freedom. Plans for future data comparisons, model evaluations, and assessments using additional LDEF data sets (LET spectra, induced radioactivity, and particle spectra) are discussed.

Armstrong, T. W.↗

FY2020 Savannah River Site Composite Analysis Annual Summary Review

This document provides the Department of Energy (DOE) Order 435.1 and its manual, Radioactive Waste Management (DOE 2021a, 2021b) required Annual Review for the Savannah River Site (SRS) Composite Analysis (CA). Progress made to-date toward addressing the secondary issue from the LFRG review of the 2010 SRS CA has focused primarily upon inventory estimate improvements. Inventory impacts dose in a linear fashion and reduces the uncertainty with the CA conclusions. Maintenance items are addressed, as funding allows, based on the relative risk associated with meeting the performance objectives. Currently, there is minimal risk in exceeding the DOE 100 mrem/yr CA primary dose limit or the DOE 30 mrem/yr dose constraint (administrative limit). Proposed activities, discoveries, new information and changes potentially affecting the 2010 SRS CA are documented in this and earlier Annual Summary reports, and a consolidated list of changes since the 2010 CA is documented in this report. The impact to the CA of changes arising from updated performance assessment (PA) baselines [i.e., Saltstone Disposal Facility (SDF), E-Area Low-Level Waste Facility (ELLWF), and F & H Tank Farm (FTF & HTF) closures] is expected to be minor for the following reasons: The primary contributors to the SRS CA dose impact at the Upper Three Runs (UTR) point of assessment (POA) are the H-Canyon and Mixed Waste Management Facility (MWMF), contributing 68% and 9%, respectively, to the dose impact at that POA. The combined contribution to the UTR dose impact from all PA’s (SDF, ELLWF, FTF and HTF) is ~2% of this total. The 2010 SRS CA model validation performed indicates that the CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. Doses evaluated are well below the SRS established 15 mrem/yr administrative limit (Crapse et al. 2011). Based on the assessment presented within this annual review and collective engineering judgement, the conclusions of the 2010 SRS CA remain valid and there is reasonable assurance that SRS will meet the performance objectives delineated in DOE Manual 435.1-1. The 2010 SRS CA should be updated to incorporate PA changes, proposed changes to inventories and sources and model improvements accumulated since the 2010 CA. The timing will be dependent on the completion of the ongoing E-Area PA revision.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Ion and Neutron Irradiations to 3 dpa at 500C in Ferritic-Martensitic Alloys

The growing global demand for energy will increasingly call upon advanced nuclear fission reactors to supply safe and reliable electricity. The structural and fuel cladding components of these reactors will be subject to extreme conditions of irradiation damage up to several hundred displacements per atom (dpa) at temperatures as high as 700°C. Ferritic-martensitic (F-M) steels are leading candidates for these challenging conditions due to their strength and dimensional stability under irradiation. In order to accelerate the process for evaluating F-M alloys, charged particles are increasingly being used to emulate neutron irradiations. Charged particle irradiations allow the possibility of conducting irradiation experiments within a shorter time period (i.e. at a rate up to 4 orders of magnitude faster) and with minimal radioactivation of the material, enabling lower cost and faster turnaround of post irradiation examination and analysis. However, the irradiation dose rate, damage cascade morphologies, and irradiation damage depth profiles all differ widely between protons, heavier ions, and neutrons. Currently, there is limited understanding of the significance of these physical differences and how they manifest in the irradiated microstructure and mechanical properties of F-M steels. The objective of this study is to evaluate charged particles as a surrogate for neutron irradiations in F-M alloys by assessing common irradiation conditions using Fe++ ions, protons, and neutrons. Keeping the temperature and dose consistent enables isolation of the effects of each irradiating particle and their respective dose rates and cascade morphologies.

Swenson, M.J.↗