At least 325 records · Page 18

Orbiter door closure tools

Safe reentry of the shuttle orbiter requires that the payload bay doors be closed and securely latched. Since a malfunction in the door drive or bulkhead latch systems could make safe reentry impossible, the requirement to provide tools to manually close and secure the doors was implemented. The tools would disconnect a disabled door or latch closure system and close and secure the doors if the normal system failed. The tools required to perform these tasks have evolved into a set that consists of a tubing cutter, a winch, a latching tool, and a bolt extractor. The design, fabrication, and performance tests of each tool are described.

Acres, W. R.↗

Health requirements for advanced coal extraction systems

Health requirements were developed as long range goals for future advanced coal extraction systems which would be introduced into the market in the year 2000. The goal of the requirements is that underground coal miners work in an environment that is as close as possible to the working conditions of the general population, that they do not exceed mortality and morbidity rates resulting from lung diseases that are comparable to those of the general population, and that their working conditions comply as closely as possible to those of other industries as specified by OSHA regulations. A brief technique for evaluating whether proposed advanced systems meet these safety requirements is presented, as well as a discussion of the costs of respiratory disability compensation.

Zimmerman, W. F.↗

The characteristics and limitations of the MPS/MMS battery charging system

A series of tests was conducted on two 12 ampere hour nickel cadmium batteries under a simulated cycle regime using the multiple voltage versus temperature levels designed into the modular power system (MPS). These tests included: battery recharge as a function of voltage control level; temperature imbalance between two parallel batteries; a shorted or partially shorted cell in one of the two parallel batteries; impedance imbalance of one of the parallel battery circuits; and disabling and enabling one of the batteries from the bus at various charge and discharge states. The results demonstrate that the eight commandable voltage versus temperature levels designed into the MPS provide a very flexible system that not only can accommodate a wide range of normal power system operation, but also provides a high degree of flexibility in responding to abnormal operating conditions.

Ford, F. E.↗

Evaluation of integral exposure energy load on aural analyzer of miners

The individual exposure integral noise load on workers before the beginning of hearing impairment was determined for a group of 20 male miners who had worked with drilling equipment and harvesters for 8 to 20 years before the onset of the disability. Results show that the total exposure energy load of about 4 kw x h sq m, obtained by miners in the examined group, resulted in occupational injury to the auditory organ (cochlear neuritis) in 75% of the cases. The equivalent energy level of noise computed according to the date of total energy load is roughly 99 db A, which significantly exceeds the permissible amount of 85 db A. There is a correlation (r = 0.77) between the integral exposure energy noise on the aural analyzer in the degree of increase in the total threshold for the mean speech range.

Kornilov, A. N.↗

Report of activities of the advanced coal extraction systems definition project, 1979 - 1980

During this period effort was devoted to: formulation of system performance goals in the areas of production cost, miner safety, miner health, environmental impact, and coal conservation, survey and in depth assessment of promising technology, and characterization of potential resource targets. Primary system performance goals are to achieve a return on incremental investment of 150% of the value required for a low risk capital improvement project and to reduce deaths and disability injuries per million man-hour by 50%. Although these performance goals were developed to be immediately applicable to the Central Appalachian coal resources, they were also designed to be readily adaptable to other coals by appending a geological description of the new resource. The work done on technology assessment was concerned with the performance of the slurry haulage system.

Lavin, M. L.↗

SMM attitude control recovery

A description is given of the way in which the Modular Attitude Control System (MACS) onboard computer of the NASA Solar Maximum Mission (SMM) laboratory was reprogrammed, to restore attitude control for the SMM, after fuse failures permanently disabled all three of the MACS primary reaction wheels. Algorithms were developed which provided both a thermal- and power-safe, spin-stabilized mode and three-axis sun pointing, using the damaged primary wheels' backup skew wheel in a momentum-bias control scheme. Magnetic torquing was used in these algorithms for angular momentum vector magnitude and directional control.

Hoffman, H. C.↗

Improving Power-Supply Regulation for Pulsed Loads

Power supply voltage-regulator circuit speeds up response to sudden load changes. As load increases, additional feedback path is enabled. Path bypasses and provides faster loop response than normal feedback path. Steady-state instability due to faster loop response avoided by progressively disabling bypass loop and allowing normal feedback path to take over.

Gulick, C. R.↗

Inflatable Rescue Capsules

Rescue spheres transfer people from disabled vehicle to rescue vehicle. Container, inflatable sphere, constructed of gastight thermalprotective fabric to provide protection during transfer.

Baker, J. L.↗

Flux Coupling for Wheelchair Battery Chargers

Battery-charger concept for wheelchairs includes magnetic-flux coupling instead of electrical connections between power sources and wheelchairs. Concept meant to facilitate operation by patients whose disabilities make it difficult or impossible to maneuver common electrical plugs into or out of ac wall outlets.

Mclyman, C. W.↗

Applications of aerospace technology in biology and medicine

Utilization of National Aeronautics and Space Administration (NASA) technology in medicine is discussed. The objective is best obtained by stimulation of the introduction of new or improved commercially available medical products incorporating aerospace technology. A bipolar donor/recipient model of medical technology transfer is presented to provide a basis for the team's methodology. That methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the Stowaway, a lightweight wheelchair that provides mobility for the disabled and elderly in the cabin of commercial aircraft, and Micromed, a portable medication infusion pump for the reliable, continuous infusion of medications such as heparin or insulin. The marketing and manufacturing factors critical to the commercialization of the lightweight walker incorporating composite materials were studied. Progress was made in the development and commercialization of each of the 18 currently active projects.

Bass, B.↗

A Comparative Study of Alternative Controls and Displays for by the Severely Physically Handicapped

A modification of a row/column scanning system was investigated in order to increase the speed and accuracy with which communication aids can be accessed with one or two switches. A selection algorithm was developed and programmed in BASIC to automatically select individuals with the characteristic difficulty in controlling time dependent control and display systems. Four systems were compared: (1) row/column directed scan (2 switches); (2) row/column auto scan (1 switch); (3) row auto scan (1 switch); and (4) column auto scan (1 switch). For this sample population, there were no significant differences among systems for scan time to select the correct target. The row/column auto scan system resulted in significantly more errors than any of the other three systems. Thus, the most widely prescribed system for severely physically disabled individuals turns out for this group to have a higher error rate and no faster communication rate than three other systems that have been considered inappropriate for this group.

Williams, D.↗

Automatic multi-banking of memory for microprocessors

A microprocessor system is provided with added memories to expand its address spaces beyond its address word length capacity by using indirect addressing instructions of a type having a detectable operations code and dedicating designated address spaces of memory to each of the added memories, one space to a memory. By decoding each operations code of instructions read from main memory into a decoder to identify indirect addressing instructions of the specified type, and then decoding the address that follows in a decoder to determine which added memory is associated therewith, the associated added memory is selectively enabled through a unit while the main memory is disabled to permit the instruction to be executed on the location to which the effective address of the indirect address instruction points, either before the indirect address is read from main memory or afterwards, depending on how the system is arranged by a switch.

Wiker, G. A.↗

Test and evaluation of the 2.4-micron photorefractor ocular screening system

An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

Richardson, J. R.↗

Main propulsion system design recommendations for an advanced Orbit Transfer Vehicle

Various main propulsion system configurations of an advanced OTV are evaluated with respect to the probability of nonindependent failures, i.e., engine failures that disable the entire main propulsion system. Analysis of the life-cycle cost (LCC) indicates that LCC is sensitive to the main propulsion system reliability, vehicle dry weight, and propellant cost; it is relatively insensitive to the number of missions/overhaul, failures per mission, and EVA and IVA cost. In conclusion, two or three engines are recommended in view of their highest reliability, minimum life-cycle cost, and fail operational/fail safe capability.

Redd, L.↗

Hydraulic Shutdown Monitor

Adding switch allows inappropriate control actions to be overridden. Four-pole, double-throw switch added to front panel of controller to disable tracking-error and endpoint-error circuitry yet still retain overload-detection capability. Previously, it was necessary to use adjustable-voltage-level detection equipment connected with cables to hydraulic "dump" or shutdown circuitry in controller.

Fleming, S. T.↗

Ferroresonant Flux-Coupled Battery Charger

Portable battery charger operates at about 20 kHz to take advantage of relatively low weight and low acoustical noise of ferroresonant circuits operating in this frequency range. Charger split into stationary unit connected to powerline and mobile unit connected to battery or other load. Power transferred to mobile unit by magnetic coupling between mating transformer halves. Advantage where sparking at electrical connection might pose explosion hazard or where operator disabled and cannot manipulate plug into wall outlet. Likely applications for charger include wheelchairs and robots.

Mclyman, C. W.↗

A methodology for testing fault-tolerant software

A methodology for testing fault tolerant software is presented. There are problems associated with testing fault tolerant software because many errors are masked or corrected by voters, limiter, or automatic channel synchronization. This methodology illustrates how the same strategies used for testing fault tolerant hardware can be applied to testing fault tolerant software. For example, one strategy used in testing fault tolerant hardware is to disable the redundancy during testing. A similar testing strategy is proposed for software, namely, to move the major emphasis on testing earlier in the development cycle (before the redundancy is in place) thus reducing the possibility that undetected errors will be masked when limiters and voters are added.

Andrews, D. M.↗

Analysis of counting errors in the phase/Doppler particle analyzer

NASA is investigating the application of the Phase Doppler measurement technique to provide improved drop sizing and liquid water content measurements in icing research. The magnitude of counting errors were analyzed because these errors contribute to inaccurate liquid water content measurements. The Phase Doppler Particle Analyzer counting errors due to data transfer losses and coincidence losses were analyzed for data input rates from 10 samples/sec to 70,000 samples/sec. Coincidence losses were calculated by determining the Poisson probability of having more than one event occurring during the droplet signal time. The magnitude of the coincidence loss can be determined, and for less than a 15 percent loss, corrections can be made. The data transfer losses were estimated for representative data transfer rates. With direct memory access enabled, data transfer losses are less than 5 percent for input rates below 2000 samples/sec. With direct memory access disabled losses exceeded 20 percent at a rate of 50 samples/sec preventing accurate number density or mass flux measurements. The data transfer losses of a new signal processor were analyzed and found to be less than 1 percent for rates under 65,000 samples/sec.

Oldenburg, John R.↗