How Dynamic Time Warping Can Assist Conventional Cross-correlation

Waveform cross-correlation is a sensitive phase-matched filtering technique that can detect seismic events for nuclear explosion monitoring. However, there are outstanding challenges with correlation detectors, most notably a direct dependence on the completeness of the waveform template library. To ameliorate these challenges, we investigate how dynamic time warping (DTW) may make waveform correlation more robust. DTW analyzes the differences between two time series and attempts to “warp” one time series relative to another in a recursive manner. We apply DTW to synthetic earthquake and recorded explosion templates to expand the capability of correlation detectors. We explore what conditions (e.g., source, station distance, frequency bands) and/or DTW algorithms generate stronger correlation scores. We show that DTW performs well on noisy signals and can dramatically improve the cross-correlation coefficient between a template and data-stream waveform. We conclude with recommendations on how to utilize DTW in nuclear monitoring detection.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Searches for New Physics With Muon Conversion at Fermilab and Triboson Production at the LHC

We report on several efforts to search for physics beyond the standard model of particle physics at broad energy scales. The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the muon to electron conversion process, which is suppressed in the Standard Model. Mu2e will be operated at a low energy, yet can probe New Physics at very high mass scales (O(1e3 - 1e4 ) TeV). At high energies, the CMS experiment at the CERN LHC continues to deliver an impressive suite of Standard Model measurements and limits on a variety of New Physics signatures. Mu2e is under construction and slated to collect its first physics data in the coming years. This thesis describes work done during the construction phase of Mu2e and focuses on two critical areas: magnetic field modeling and statistical analysis. We describe a novel method for field modeling which we validate using a simulated dataset representing the expected magnetic field in the Detector Solenoid. This method blends a standard least-squares fitting technique that utilizes physically motivated analytical model functions with a novel physics informed network that is constructed to obey Maxwell’s equations. We show the technique can model the field with an accuracy of 10−7 despite the presence of injected noise in the pseudo-measurements at the 10−5 level. We then present preliminary results of the calibration of 3D Hall probes at the sub-10−4 level. These probes will be used to directly measure the Mu2e Detector Solenoid magnetic field on a sparse grid; these measurements serve as the input to the field model fitting. Finally, we describe the first implementation of both an unbinned shape analysis and a Bayesian interpretation applied to Mu2e pseudo-data. Up to 20% tighter limits can be set by the shape analysis compared to a standard cut & count analysis. The AlCap experiment collected data at PSI in 2015 to measure several important quantities related to nuclear muon capture on an aluminum target, which is a significant background process for Mu2e. The neutron emission from muon capture can introduce background hits in the Mu2e detectors and can increase radiation damage in various elements of the apparatus. We present measurements of the neutron group fluence and mean neutron multiplicity for muon capture on aluminum nuclei. Finally, we discuss an analysis of triboson production at CMS using an Effective Field Theory framework. Standard Model triboson production, which was first observed at CMS in 2020, has a relatively small cross section and provides direct access to both anomalous triple gauge couplings and quartic gauge couplings. These couplings, interpreted in the Standard Model Effective Field Theory, are studied in the present work. We target the boosted regime where the background rate is low and yields are enhanced when dimension-6 and dimension-8 Wilson coefficients are non-zero. We do not observe an excess in the data and therefore set bounds on the Wilson coefficients. For dimension-6 coefficients the tightest observed (expected) bounds are set on cW /Λ2 where Λ is the mass scale of new physics; the bounds are [−0.13, 0.12] TeV−2 ([−0.12, 0.12] TeV−2 ) at 95% CL. The tightest bounds in dimension-8 are set on fT,0 / Λ4 ; the observed (expected) bounds at 95% CL are [−0.63, 0.69] TeV−4 ([−0.54, 0.62] TeV−4 ). Additional results are presented which include scenarios where multiple Wilson coefficients are non-zero, the application of signal model clipping to address unitarity violation in Effective Field Theories, and a novel template fit developed for easier reinterpretation of our results.

Kampa, Cole Erik [Northwestern U. (main)] (ORCID:0↗

Real-time Anomaly Detection for Liquid Argon Time Projection Chambers

We present a real-time anomaly detection framework for liquid argon time projection chambers (LArTPCs), targeting applications in particle physics experiments such as the Short Baseline Near Detector (SBND) or the future Deep Underground Neutrino Experiment (DUNE). These experiments employ detectors that generate and stream high-resolution but sparse images of neutrino and other particle interactions. Our approach utilizes anomaly detection with autoencoders, compressed through knowledge distillation (KD), to enable the detection of anomalous signals in the data through efficient inference on resource-constrained hardware. The framework is targeted for deployment on computing platforms equipped with field-programmable gate arrays (FPGAs), GPUs, or CPUs, allowing low-latency selection of relevant activity directly from the raw detector data stream. We demonstrate that our approach is suitable for the detection and localization of anomalously "high-multiplicity" activity, and outline promising applications for LArTPC online data filtering and triggering.

FOS: Physical sciences↗

Development of a drift-correction procedure for a photoelectric spectrometer

A technique has been developed to automatically correct for drifts in the radiometric sensitivity of the detector channels in a direct-reading emission spectrometer. The method utilizes a 1000 W tungsten-halogen reference lamp to illuminate the detectors through the same optical path as that traversed during the analysis of the sample. Detector channel responses to the light are compared to those for the same light intensity at the time of analytical calibration. This corrects for the drift. It is noted that with the exception of positioning the lamp, the procedure is fully automatic.

Chapman, G. B., II↗

A preliminary investigation into the electrodeposition and synthesis of radiopure Copper–Chromium alloys for rare-event physics detector systems

Current investigations into neutrinoless double beta decay and the direct detection of dark matter require increasingly sensitive detector systems that demand ultra-low background materials. These requirements have previously been attained using ultra-radiopure electroformed (EF) copper. However, pure copper possesses high ductility and relatively low strength, which necessitates the need for large amounts of material and extra care during fabrication to help minimize galling and mechanical failure. Furthermore, we investigate an alloying alternative to pure EF copper by examining low wt% copper chrome (Cu–Cr) solid solution alloys, with inquiries into alloy hardness, strength, and radiopurity. Alloyed Cu–Cr layered samples are shown to exhibit significantly increased hardness compared to EF copper, for example showing a 50% increase in exhibited hardness using less than 1% Cr by weight, with limited negative impact to the material’s radiopurity.

Background↗

Reducing ion diffusion at atmospheric pressure through intermingled positive and negative ions

Increasing ion molecule reaction times for ambient ionization techniques can increase sensitivity of detection. Longer reaction times result in an increase in analyte signal relative to the reactant ion signal, however with a subsequent decrease in the total ion intensity. This loss in the total number of ions reaching the detector limits the extent to which increased reaction time can improve detection in practical applications. In this study ion loss was measured using either electric fields or gas flow to control ion transit time. Ion transit times ranged from 40 ms to 8s, which resulted in ion densities ranging from 5 x 10 6 to 2 x 10 4 ions/cm 3 , respectively. These results provide insights into practical reaction time limitations or experimental boundaries when exploring sensitivity enhancements in ambient ionization. When exploring longer reaction times with an atmospheric flow tube coupled to a mass spectrometer (AFT-MS), an additional corona discharge ionization source of the same polarity was added in an attempt to increase total ion signal, but no improvement in signal was observed. This observation suggested that there was a maximum ion density being reached by the corona discharge that could not be increased by adding more of the same polarity ions. A hypothesis was that intermingling both polarities of ions would reduce ion loss and increase the measured ion signal. When two corona discharge sources—one each of positive and negative polarity—were used simultaneously in an AFT-MS, the total ion signal of either polarity measured by the MS was approximately double the current from a single corona discharge source. An increase in the negative ion signal was also observed when ~10 parts-per-trillion vapor levels of an explosive (RDX) were introduced. In this case both the nitrate reactant ions and the RDX signal more than doubled with the addition of a corona discharge source producing positive ions. When intermingling positive and negative ions, an increase in ion current was also observed when the AFT was coupled directly to a Faraday detector or to an ion mobility spectrometer. This was the first demonstration of interfacing the AFT to an IMS. The observations and developments from this work will help in creating more portable instruments with improved sensitivity for detection of chemicals.

47 OTHER INSTRUMENTATION↗

Search for R -parity violating supersymmetric decays of the top squark to a b -jet and a lepton in s = 13 TeV p p collisions with the ATLAS detector

A search is presented for direct pair production of the stop, the supersymmetric partner of the top quark, in a decay through an R-parity violating coupling to a charged lepton and a b-quark. The dataset corresponds to an integrated luminosity of 140 fb -1 of proton-proton collisions at a center-of-mass energy of $\sqrt{s}$=13 TeV collected between 2015 and 2018 by the ATLAS detector at the LHC. The final state has two charged leptons (electrons or muons) and two b-jets. The results of the search are interpreted in the context of a Minimal Supersymmetric Standard Model with an additional B -L gauge symmetry that is spontaneously broken. No significant excess is observed over the Standard Model background, and exclusion limits on stop pair production are set at 95% confidence level. The corresponding lower limits on the stop mass for 100% branching ratios to a b-quark and an electron, muon, or tau-lepton are 1.9 TeV, 1.8 TeV and 800 GeV, respectively, extending the reach of previous LHC searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

Direct metal contacts printing on 4H-SiC for alpha detectors and inhomogeneous Schottky barriers

Electrical characterization of several 4H-SiC Schottky diodes with Aerosol-Jet printed gold (Au), silver (Ag), and platinum (Pt) contacts was performed using forward and reverse current–voltage (IV) measurements. From these measurements, device parameters such as Schottky barrier height and ideality factor were determined; however, many of the devices exhibited nonideal behavior and inferior performance characterized by ideality factors significantly greater than one, disproportionate low voltage leakage current and low barrier heights. Forward current–voltage (FIV) characteristics were fitted to an inhomogeneous barrier height theory to explain the abnormal behavior exhibited by the printed devices. Here, transmission electron microscopy (TEM) of the device cross-sections was performed to investigate the printed metal and semiconductor epitaxial layer interface, which revealed the imperfections in the metal–semiconductor contact. Despite these irregularities, alpha radiation detection capability of these devices was still achieved with an energy resolution of 1.89% at 5.486 MeV, and the best achievable resolution at 0.51% with no energy degradation of 5.486 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

G4VG

G4VG reads the in-memory Geant4 geometry (the volume hierarchy and physical shape descriptions defined by a user application) and produces an equivalent VecGeom representation. This provides a direct bridge between Geant4 detector descriptions and VecGeom-based applications, eliminating the need for manual export pipelines or specialized GDML workflows. The code is adapted from the Celeritas project and developed as an independent utility for broader reuse.

Johnson, SethR [Oak Ridge National Laboratory] (00↗

Results of eye examination

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, and four survived. All the eyes, except one eye from the dead flight mouse, were examined histologically. In the four surviving mice, a total of five cosmic-ray particles which had registered in the subscalp particle detectors had trajectories that intersected the eyes. Four of them (Z = 6.9 for three of the particles and Z greater than or equal to 10 for the fourth) most likely went through the head before reaching the particle detector, while the thindown direction of the fifth (Z greater than or equal to 10) was not determinable. The retinas of the flight animals were found free from histological alterations such as might have been expected from encounters with cosmic-ray particles.

Philpott, D. E.↗

Noise spectra for monolithic detector arrays

Following a brief review of nonstationary processes, the paper deals with mixed stationary processes as they apply to the determination of the power density spectrum for monolithic detector arrays. A rather direct method is developed for realizing the noise power spectrum by transforming the corresponding autocorrelation function. Although the measurements presented pertain to a 96-element photodiode linear array, the method outlined should be applicable to any monolithic device. Theoretical and experimental results are provided.

Finkel, M. W.↗

Large volume multiple path nuclear lasing of /He-3/-Ar

Output power of 550 W has been achieved from a nuclear-pumped multiple path laser system containing (He-3)-Ar by using the (He-3)(n, p)3(H) nuclear reaction for power deposition. Lasing was achieved in Ar at 1790 nm. The complex beam profile was resolved by an InAs array detector. Laser output was directly proportional to thermal neutron flux, and also increased proportionally with increasing (He-3) pressure up to 292.6 kPa. The variation of the laser output power with the number of passes through the excited medium was found to peak at 5-7 passes.

De Young, R. J.↗