Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “different”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Conversion of mammographic images to appear with the noise and sharpness characteristics of a different detector and x-ray system

Purpose: Undertaking observer studies to compare imaging technology using clinical radiological images is challenging due to patient variability. To achieve a significant result, a large number of patients would be required to compare cancer detection rates for different image detectors and systems. The aim of this work was to create a methodology where only one set of images is collected on one particular imaging system. These images are then converted to appear as if they had been acquired on a different detector and x-ray system. Therefore, the effect of a wide range of digital detectors on cancer detection or diagnosis can be examined without the need for multiple patient exposures. Methods: Three detectors and x-ray systems [Hologic Selenia (ASE), GE Essential (CSI), Carestream CR (CR)] were characterized in terms of signal transfer properties, noise power spectra (NPS), modulation transfer function, and grid properties. The contributions of the three noise sources (electronic, quantum, and structure noise) to the NPS were calculated by fitting a quadratic polynomial at each spatial frequency of the NPS against air kerma. A methodology was developed to degrade the images to have the characteristics of a different (target) imaging system. The simulated images were created by first linearizing the original images such that the pixel values were equivalent to the air kerma incident at the detector. The linearized image was then blurred to match the sharpness characteristics of the target detector. Noise was then added to the blurred image to correct for differences between the detectors and any required change in dose. The electronic, quantum, and structure noise were added appropriate to the air kerma selected for the simulated image and thus ensuring that the noise in the simulated image had the same magnitude and correlation as the target image. A correction was also made for differences in primary grid transmission, scatter, and veiling glare. The method was validated by acquiring images of a CDMAM contrast detail test object (Artinis, The Netherlands) at five different doses for the three systems. The ASE CDMAM images were then converted to appear with the imaging characteristics of target CR and CSI detectors. Results: The measured threshold gold thicknesses of the simulated and target CDMAM images were closely matched at normal dose level and the average differences across the range of detail diameters were -4% and 0% for the CR and CSI systems, respectively. The conversion was successful for images acquired over a wide dose range. The average difference between simulated and target images for a given dose was a maximum of 11%. Conclusions: The validation shows that the image quality of a digital mammography image obtained with a particular system can be degraded, in terms of noise magnitude and color, sharpness, and contrast to account for differences in the detector and antiscatter grid. Potentially, this is a powerful tool for observer studies, as a range of image qualities can be examined by modifying an image set obtained at a single (better) image quality thus removing the patient variability when comparing systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-53: Variation in Measurements of Breast Skin Thickness Obtained Using Different Imaging Modalities

Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution, with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality.

60 APPLIED LIFE SCIENCES↗

System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads

A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Method and system employing graphical electric load categorization to identify one of a plurality of different electric load types

A system for different electric loads includes sensors structured to sense voltage and current signals for each of the different electric loads; a hierarchical load feature database having a plurality of layers, with one of the layers including a plurality of different load categories; and a processor. The processor acquires voltage and current waveforms from the sensors for a corresponding one of the different electric loads; maps a voltage-current trajectory to a grid including a plurality of cells, each of which is assigned a binary value of zero or one; extracts a plurality of different features from the mapped grid of cells as a graphical signature of the corresponding one of the different electric loads; derives a category of the corresponding one of the different electric loads from the database; and identifies one of a plurality of different electric load types for the corresponding one of the different electric loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Resolution Mass Spectrometry Quantification: Impact of Differences in Data Processing of Centroid and Continuum Data

High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth of different phases and morphological features of MnS thin films by chemical bath deposition: Effect of deposition parameters and annealing

Manganese sulfide thin films have been deposited on glass slides by chemical bath deposition (CBD) method. The effects of preparative parameters such as deposition time, bath temperature, concentration of precursors, multi-layer deposition, different source of manganese, different complexing agent and thermal annealing on structural and morphological film properties have been investigated. The prepared thin films have been characterized using the X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDX). It exhibit the metastable forms of MnS, the hexagonal γ-MnS wurtzite phase with preferential orientation in the (002) plane or the cubic β-MnS zinc blende with preferential orientation in the (200) plane. Microstructural studies revealed the formation of MnS crystals with different morphologies, such as hexagons, spheres, cubes or flowers like. - Graphical Abstract: We report the preparation of different phases of manganese sulfide thin films (γ, β and α-MnS) by chemical bath deposition method. The effects of deposition parameters such as deposition time and temperature, concentrations of precursors and multi-layer deposition on MnS thin films structure and morphology were investigated. The influence of thermal annealing under nitrogen atmosphere at different temperature on MnS properties was also studied. Different manganese precursors as well as different complexing agent were also used. - Highlights: • γ and β-MnS films were deposited on substrate using the chemical bath deposition. • The effect of deposition parameters on MnS film properties has been investigated. • Multi-layer deposition was also studied to increase film thickness. • The effect of annealing under N{sub 2} at different temperature was investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scale dependence in functional equivalence and difference in the soil microbiome

Climatic history can shape the functioning of soil microbial communities and thus rates of ecosystem processes such as organic matter decomposition. For example, broad spatial scale differences in climatic history, such as contrasting precipitation regimes, have been shown to generate unique microbial functional responses to contemporary moisture conditions. Yet it is an open question as to whether local differences in soil microclimate similarly influence the functional potential of decomposer communities. Here, we use a multi-scale approach within and among two temperate forest field sites to investigate this question. Soils from fifty-four microsites, that vary in their soil moisture climate-regimes, were used as inocula for a common leaf litter (Quercus rubra L.) in a controlled, laboratory microcosm study. Microcosms were placed under dry, mesic and wet lab-moisture conditions and the rate of carbon (C) mineralization of the litter was measured over 202 days. Our results reveal differences in decomposition rates under controlled conditions that highlight broad-scale functional differences between the soil communities at each site. Specifically, we found that C mineralization differed by as much as two-fold for soil communities when compared between the sites. Our results also show that functional differences of soil communities are observable within one site but not the other. In the site where local-scale functional legacies were apparent, the historical soil moisture microclimate-regimes generated as much as an 89% change in C mineralization rates of the leaf litter under the same contemporary, lab-imposed moisture conditions. Here, a similar pattern was not observable in the other site; instead, laboratory moisture conditions explained almost all variation in C mineralization. Notably, for the site with pronounced local-scale functional legacies, there was much greater within-site variation in field-soil microsite moisture than at the site which did not exhibit functional legacies, suggesting that the extent of local-scale variation in microclimate may act as control on whether local-scale functional legacies are observed. Regardless of whether this mechanism does explain our findings, our observations do confirm those from prior studies where regional-scale moisture-regime differences shape microbial function, and extend this prior work by providing evidence that pronounced local-scale differences in soil moisture microclimate-regimes are associated with microbial functional legacies.

54 ENVIRONMENTAL SCIENCES↗

Sex-related differences in murine hepatic transcriptional and proteomic responses to TCDD

2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD) is an environmental contaminant that produces myriad toxicities in most mammals. In rodents alone, there is a huge divergence in the toxicological response across species, as well as among different strains within a species. But there are also significant differences between males and females animals of a single strain. These differences are inconsistent across model systems: the severity of toxicity is greater in female rats than males, while male mice and guinea pigs are more sensitive than females. Because the specific events that underlie this difference remain unclear, we characterized the hepatic transcriptional response of adult male and female C57BL/6 mice to 500 μg/kg TCDD at multiple time-points. The transcriptional profile diverged significantly between the sexes. Female mice demonstrated a large number of altered transcripts as early as 6 h following treatment, suggesting a large primary response. Conversely, male animals showed the greatest TCDD-mediated response 144 h following exposure, potentially implicating significant secondary responses. Nr1i3 was statistically significantly induced at all time-points in the sensitive male animals. This mRNA encodes the constitutive androstane receptor (CAR), a transcription factor involved in the regulation of xenobiotic metabolism, lipid metabolism, cell cycle and apoptosis. Surprisingly though, changes at the protein level (aside from the positive control, CYP1A1) were modest, with only FMO3 showing clear induction, and no genes with sex-differences. Thus, while male and female mice show transcriptional differences in their response to TCDD, their association with TCDD-induced toxicities remains unclear. - Highlights: • Differences exist between the toxicity phenotypes to TCDD in male and female mice. • TCDD-mediated transcriptomic differences were identified between the sexes. • Resistant female mice displayed a large, early-onset, transcriptomic response. • Sensitive male mice displayed a large, late-onset, transcriptomic response. • Fmo2, Fmo3 and Nr1i3 were induced across the time-course in only male mice.

60 APPLIED LIFE SCIENCES↗

Shining Light on the Differences in Molecular Structural Chemical Makeup and the Cause of Distinct Degradation Behavior Between Malting- and Feed- Type Barley Using Synchrotorn FTIR Microspectroscopy: A Novel Approach

The objective of this study was to use advanced synchrotron-sourced FTIR microspectroscopy (SFTIRM) as a novel approach to identify the differences in protein and carbohydrate molecular structure (chemical makeup) between these two varieties of barley and illustrate the exact causes for their significantly different degradation kinetics. Items assessed included (1) molecular structural differences in protein amide I to amide II intensities and their ratio within cellular dimensions, (2) molecular structural differences in protein secondary structure profile and their ratios, and (3) molecular structural differences in carbohydrate component peak profile. Our hypothesis was that molecular structure (chemical makeup) affects barley quality, fermentation, and degradation behavior in both humans and animals. Using SFTIRM, the protein and carbohydrate molecular structural chemical makeup of barley was revealed and identified. The protein molecular structural chemical makeup differed significantly between the two varieties of barleys. No difference in carbohydrate molecular structural chemical makeup was detected. Harrington was lower than Valier in protein amide I, amide II, and protein amide I to amide II ratio, while Harrington was relatively higher in model-fitted protein a-helix and {beta}-sheet, but lower in the others ({beta}-turn and random coil). These results indicated that it is the molecular structure of protein (chemical makeup) that may play a major role in the different degradation kinetics between the two varieties of barleys (not the molecular structure of carbohydrate). It is believed that use of the advanced synchrotron technology will make a significant step and an important contribution to research in examining the molecular structure (chemical makeup) of plant, feed, and seeds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Slope-Aspect Induced Climate Differences Influence How Water Is Exchanged Between the Land and Atmosphere

Cross-slope climate differences in the midlatitudes are ecologically important, and impact vegetation-mediated water balance between the earth surface and the atmosphere. We made high-resolution in situ observations of air temperature, relative humidity, soil moisture, insolation, and sap velocity observations on 14 Pacific madrone trees (Arbutus menziesii) spanning adjacent north and south slopes at the University of California's Angelo Coast Range Reserve. To understand the cross-slope response of sap velocity, a proxy for transpiration, to microclimate, we modeled the sap velocity on each slope using a transpiration model driven by ambient environment and parameterized with a Markov Chain Monte Carlo parameter estimation process. The results show that trees on opposing slopes do not follow a shared pattern of physiological response to transpiration drivers. This means that the observed sap velocity differences are not due entirely to observed microclimate differences, but also due to population-level physiological differences, which indicates acclimation to inhabited microclimate. While our present data set and analytical tools do not identify mechanisms of acclimation, we speculate that differing proportions of sun-adapted and shade-adapted leaves, differences in stomatal regulation, and cross-slope root zone moisture differences could explain some of the observed and modeled differences.

54 ENVIRONMENTAL SCIENCES↗

Quantum chemical ab initio prediction of proton exchange barriers between CH{sub 4} and different H-zeolites

A hybrid MP2:DFT (second-order Møller–Plesset perturbation theory–density functional theory) method that combines MP2 calculations for cluster models with DFT calculations for the full periodic structure is used to localize minima and transition structures for proton jumps at different Brønsted sites in different frameworks (chabazite, faujasite, ferrierite, and ZSM-5) and at different crystallographic positions of a given framework. The MP2 limit for the periodic structures is obtained by extrapolating the results of a series of cluster models of increasing size. A coupled-cluster (CCSD(T)) correction to MP2 energies is calculated for cluster models consisting of three tetrahedra. For the adsorption energies, this difference is small, between 0.1 and 0.9 kJ/mol, but for the intrinsic proton exchange barriers, this difference makes a significant (10.85 ± 0.25 kJ/mol) and almost constant contribution across different systems. The total values of the adsorption energies vary between 22 and 34 kJ/mol, whereas the total proton exchange energy barriers fall in the narrow range of 152–156 kJ/mol. After adding nuclear motion contributions (harmonic approximation, 298 K), intrinsic enthalpy barriers between 134 and 141 kJ/mol and apparent energy barriers between 105 and 118 kJ/mol are predicted for the different sites examined for the different frameworks. These predictions are consistent with experimental results available for faujasite, ferrierite, and ZSM-5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The evaluation of the earthquake hazard using the exponential distribution method for different seismic source regions in and around Ağrı

The aim of this study; were determined of the earthquake hazard using the exponential distribution method for different seismic sources of the Ağrı and vicinity. A homogeneous earthquake catalog has been examined for 1900-2015 (the instrumental period) with 456 earthquake data for Ağrı and vicinity. Catalog; Bogazici University Kandilli Observatory and Earthquake Research Institute (Burke), National Earthquake Monitoring Center (NEMC), TUBITAK, TURKNET the International Seismological Center (ISC), Seismological Research Institute (IRIS) has been created using different catalogs like. Ağrı and vicinity are divided into 7 different seismic source regions with epicenter distribution of formed earthquakes in the instrumental period, focal mechanism solutions, and existing tectonic structures. In the study, the average magnitude value are calculated according to the specified magnitude ranges for 7 different seismic source region. According to the estimated calculations for 7 different seismic source regions, the biggest difference corresponding with the classes of determined magnitudes between observed and expected cumulative probabilities are determined. The recurrence period and earthquake occurrence number per year are estimated of occurring earthquakes in the Ağrı and vicinity. As a result, 7 different seismic source regions are determined occurrence probabilities of an earthquake 3.2 magnitude, Region 1 was greater than 6.7 magnitude, Region 2 was greater than than 4.7 magnitude, Region 3 was greater than 5.2 magnitude, Region 4 was greater than 6.2 magnitude, Region 5 was greater than 5.7 magnitude, Region 6 was greater than 7.2 magnitude, Region 7 was greater than 6.2 magnitude. The highest observed magnitude 7 different seismic source regions of Ağrı and vicinity are estimated 7 magnitude in Region 6. Region 6 are determined according to determining magnitudes, occurrence years of earthquakes in the future years, respectively, 7.2 magnitude was in 158 years, 6.7 magnitude was in 70 years, 6.2 magnitude was in 31 years, 5.7 magnitude was in 13 years, 5.2 magnitude was in 6 years.

58 GEOSCIENCES↗

Quantification of differences in the effective atomic numbers of healthy and cancerous tissues: A discussion in the context of diagnostics and dosimetry

Purpose: There are a range of genetic and nongenetic factors influencing the elemental composition of different human tissues. The elemental composition of cancerous tissues frequently differs from healthy tissue of the same organ, particularly in high-Z trace element concentrations. For this reason, one could suggest that this may be exploited in diagnostics and perhaps even influence dosimetry. Methods: In this work, for the first time, effective atomic numbers are computed for common cancerous and healthy tissues using a robust, energy-dependent approach between 10 keV and 100 MeV. These are then quantitatively compared within the context of diagnostics and dosimetry. Results: Differences between effective atomic numbers of healthy and diseased tissues are found to be typically less than 10%. Fibrotic tissues and calcifications of the breast exhibit substantial (tens to hundreds of percent) differences to healthy tissue. Expectedly, differences are most pronounced in the photoelectric regime and consequently most relevant for kV imaging/therapy and radionuclides with prominent low-energy peaks. Cancerous tissue of the testes and stomach have lower effective atomic numbers than corresponding healthy tissues, while diseased tissues of the other organ sites typically have higher values. Conclusions: As dose calculation approaches improve in accuracy, there may be an argument for the explicit inclusion of pathologies. This is more the case for breast, penile, prostate, nasopharyngeal, and stomach cancer, less so for testicular and kidney cancer. The calculated data suggest dual-energy computed tomography could potentially improve lesion identification in the aforementioned organs (with the exception of testicular cancer), with most import in breast imaging. Ultimately, however, the differences are very small. It is likely that the assumption of a generic 'tissue ramp' in planning will be sufficient for the foreseeable future, and that the Z differences do not notably aid lesion detection beyond that already facilitated by differences in mass density.

60 APPLIED LIFE SCIENCES↗

TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom

Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.

60 APPLIED LIFE SCIENCES↗

SU-E-T-430: Feasibility Study On Using Overlap Volume Histogram to Predict the Dose Difference by Respiratory Motion

Purpose: The dose difference between three-dimensional dose (3D dose) and 4D dose which considers motion due to respiratory can be varied according to geometrical relationship between planning target volume (PTV) and organ at risk (OAR). The purpose of the study is to investigate the dose difference between 3D and 4D dose using overlap volume histogram (OVH) which is an indicator that quantify geometrical relationship between a PTV and an OAR. Methods: Five liver cancer patients who previously treated stereotactic body radiotherapy (SBRT) were investigated. Four-dimensional computed tomography (4DCT) images were acquired for all patients. ITV-based treatment planning was performed. 3D dose was calculated on the end-exhale phase image as a reference phase image. 4D dose accumulation was implemented from all phase images using dose warping technique used deformable image registration (DIR) algorithm (Horn and Schunck optical flow) in DIRART. In this study OVH was used to quantify geometrical relationship between a PTV and an OAR. OVH between a PTV and a selected OAR was generated for each patient case and compared for all cases. The dose difference between 3D and 4D dose for normal organ was calculated and compared for all cases according to OVH. Results: The 3D and 4D dose difference for OAR was analyzed using dose-volume histogram (DVH). On the basis of a specific point which corresponds to 10% of OAR volume overlapped with expanded PTV, mean dose difference was 34.56% in minimum OVH distance case and 13.36% in maximum OVH distance case. As the OVH distance increased, mean dose difference between 4D and 3D dose was decreased. Conclusion: The tendency of dose difference variation was verified according to OVH. OVH is seems to be indicator that has a potential to predict the dose difference between 4D and 3D dose. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

SU-F-R-34: Quantitative Perfusion Measurement in Rectal Cancer Using Three Different Pharmacokinetic Models: Implications for Prospective Study Design

Purpose: To compare three different pharmacokinetic models for analysis of dynamic-contrast-enhanced (DCE)-CT data with respect to different acquisition times and location of region of interest. Methods: Eight rectal cancer patients with pre-treatment DCE-CTs were included. The dynamic sequence started 4–10seconds(s) after the injection of contrast agent. The scan included a 110s acquisition with intervals of 40×1s+15×3s+4×6s. An experienced oncologist outlined the tumor region. Hotspots with top-5%-enhancement were also identified. Pharmacokinetic analysis was performed using three different models: deconvolution method, Patlak model, and modified Toft’s model. Perfusion parameters as blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface-area-product (PS), volume transfer constant (Ktrans), and flux rate constant (Kep), were compared with respect to different acquisition times of 45s, 65s, 85s and 105s. Both hotspot and whole-volume variances were also assessed. The differences were compared using the Wilcoxon matched-pairs test and Bland-Altman plots. Results: Moderate correlation was observed for various perfusion parameters (r=0.56–0.72, p<0.0001) but the Wilcoxon test revealed a significant difference among the three models (P < .001). Significant differences in PS were noted between acquisitions of 45s versus longer time of 85s or 105s (p<0.05) using Patlak but not with the deconvolution method. In addition, measurements varied substantially between whole-volume vs. hotspot analysis. Conclusion: The radiation dose of DCE-CT was on average 1.5 times of an abdomen/pelvic CT, which is not insubstantial. To take the DCE-CT forward as a biomarker in oncology, prospective studies should be carefully designed with the optimal image acquisition and analysis technique. Our study suggested that: (1) different kinetic models are not interchangeable; (2) a 45s acquisition might not be sufficient for reliable permeability measurement in rectal cancer using Patlak model, but might be achievable using deconvolution method; and (3) local variations existed inside the tumor, and both whole-volume-averaged and local-heterogeneity analysis is recommended for future quantitative studies. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

Determinants of rural-urban differences in health care provider visits among women of reproductive age in the United States

Background Rural health disparities and access gaps may contribute to higher maternal and infant morbidity and mortality. Understanding and addressing access barriers for specialty women’s health services is important in mitigating risks for adverse childbirth events. The objective of this study was to investigate rural-urban differences in health care access for women of reproductive age by examining differences in past-year provider visit rates by provider type, and quantifying the contributing factors to these findings. Methods and findings Using a nationally-representative sample of reproductive age women (n = 37,026) from the Medical Expenditure Panel Survey (2010–2015) linked to the Area Health Resource File, rural-urban differences in past-year office visit rates with health care providers were examined. Blinder-Oaxaca decomposition analysis quantified the portion of disparities explained by individual- and county-level sociodemographic and provider supply characteristics. Overall, there were no rural-urban differences in past-year visits with women’s health providers collectively (65.0% vs 62.4%), however differences were observed by provider type. Rural women had lower past-year obstetrician-gynecologist (OB-GYN) visit rates than urban women (23.3% vs. 26.6%), and higher visit rates with family medicine physicians (24.3% vs. 20.9%) and nurse practitioners/physician assistants (NPs/PAs) (24.6% vs. 16.1%). Lower OB-GYN availability in rural versus urban counties (6.1 vs. 13.7 providers/100,000 population) explained most of the rural disadvantage in OB-GYN visit rates (83.8%), and much of the higher family physician (80.9%) and NP/PA (50.1%) visit rates. Other individual- and county-level characteristics had smaller effects on rural-urban differences. Conclusion Although there were no overall rural-urban differences in past-year visit rates, the lower OB-GYN availability in rural areas appears to affect the types of health care providers seen by women. Whether rural women are receiving adequate specialized women’s health care services, while seeing a different cadre of providers, warrants further investigation and has particular relevance for women experiencing high-risk pregnancies and deliveries.

60 APPLIED LIFE SCIENCES↗

Comparing Genome-Wide Association Study Results from Different Measurements of an Underlying Phenotype

Increasing popularity of high-throughput phenotyping technologies, such as image-based phenotyping, offer novel ways for quantifying plant growth and morphology. These new methods can be more or less accurate and precise than traditional, manual measurements. Many large-scale phenotyping efforts are conducted to enable genome-wide association studies (GWAS), but it is unclear exactly how alternative methods of phenotyping will affect GWAS results. In this study we simulate phenotypes that are controlled by the same set of causal loci but have differing heritability, similar to two different measurements of the same morphological character. We then perform GWAS with the simulated traits and create receiver operating characteristic (ROC) curves from the results. The areas under the ROC curves (AUCs) provide a metric that allows direct comparisons of GWAS results from different simulated traits. We use this framework to evaluate the effects of heritability and the number of causative loci on the AUCs of simulated traits; we also test the differences between AUCs of traits with differing heritability. We find that both increasing the number of causative loci and decreasing the heritability reduce a trait's AUC. We also find that when two traits are controlled by a greater number of causative loci, they are more likely to have significantly different AUCs as the difference between their heritabilities increases. When simulation results are applied to measures of tassel morphology, we find no significant difference between AUCs from GWAS using manual and image-based measurements of typical maize tassel characters. This finding indicates that both measurement methods have similar ability to identify genetic associations. These results provide a framework for deciding between competing phenotyping strategies when the ultimate goal is to generate and use phenotype-genotype associations from GWAS.

59 BASIC BIOLOGICAL SCIENCES↗