Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “difference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Investigation of the level difference between sound pressure and sound intensity in an aircraft cabin under different fuselage conditions

Problems in using two-microphone sound-intensity (SI) measurements to measure structural transmission losses are investigated in experiments involving light-aircraft fuselage panels and windows. Both sound pressure (SP) and SI are measured near the passenger and door windows and panels of a single-engine aircraft and with these barriers removed, and the effect of increasing interior acoustic absorption and blocking flanking transmission paths is also tested. The results are presented graphically, and the SP measurements are used to indicate frequency ranges in which the two-microphone technique significantly underestimates SI. It is inferred that flanking paths and interior reverberation must be effectively suppressed in order to obtain accurate transmission-loss measurements.

Atwal, M. S.↗

Thermal power transfer system using applied potential difference to sustain operating pressure difference

A thermal power transfer system using a phase change liquid gas fluid in a closed loop configuration has a heat exchanger member connected to a gas conduit for inputting thermal energy into the fluid. The pressure in the gas conduit is higher than a liquid conduit that is connected to a heat exchanger member for outputting thermal energy. A solid electrolyte member acts as a barrier between the gas conduit and the liquid conduit adjacent to a solid electrolyte member. The solid electrolyte member has the capacity of transmitting ions of a fluid through the electrolyte member. The ions can be recombined with electrons with the assistance of a porous electrode. An electrical field is applied across the solid electrolyte member to force the ions of the fluid from a lower pressure liquid conduit to the higher pressure gas conduit.

Bhandari, Pradeep↗

NADH oxidase activity (NOX) and enlargement of HeLa cells oscillate with two different temperature-compensated period lengths of 22 and 24 minutes corresponding to different NOX forms

NOX proteins are cell surface-associated and growth-related hydroquinone (NADH) oxidases with protein disulfide-thiol interchange activity. A defining characteristic of NOX proteins is that the two enzymatic activities alternate to generate a regular period length of about 24 min. HeLa cells exhibit at least two forms of NOX. One is tumor-associated (tNOX) and is inhibited by putative quinone site inhibitors (e.g., capsaicin or the antitumor sulfonylurea, LY181984). Another is constitutive (CNOX) and refractory to inhibition. The periodic alternation of activities and drug sensitivity of the NADH oxidase activity observed with intact HeLa cells was retained in isolated plasma membranes and with the solubilized and partially purified enzyme. At least two activities were present. One had a period length of 24 min and the other had a period length of 22 min. The lengths of both the 22 and the 24 min periods were temperature compensated (approximately the same when measured at 17, 27 or 37 degrees C) whereas the rate of NADH oxidation approximately doubled with each 10 degrees C rise in temperature. The rate of increase in cell area of HeLa cells when measured by video-enhanced light microscopy also exhibited a complex period of oscillations reflective of both 22 and 24 min period lengths. The findings demonstrate the presence of a novel oscillating NOX activity at the surface of cancer cells with a period length of 22 min in addition to the constitutive NOX of non-cancer cells and tissues with a period length of 24 min.

Non-NASA Center↗

Magnetic Reconnection in Different Environments: Similarities and Differences

Depending on the specific situation, magnetic reconnection may involve symmetric or asymmetric inflow regions. Asymmetric reconnection applies, for example, to reconnection at the Earth's magnetopause, whereas reconnection in the nightside magnetotail tends to involve more symmetric geometries. A combination of review and new results pertaining to magnetic reconnection is being presented. The focus is on three aspects: A basic, MHD-based, analysis of the role magnetic reconnection plays in the transport of energy, followed by an analysis of a kinetic model of time dependent reconnection in a symmetric current sheet, similar to what is typically being encountered in the magnetotail of the Earth. The third element is a review of recent results pertaining to the orientation of the reconnection line in asymmetric geometries, which are typical for the magnetopause of the Earth, as well as likely to occur at other planets.

Reconnection↗

T2M Forecasts at Subseasonal Leads: Do Different Soil Moisture Initial States Have Different Impacts?

Soil moisture (W) helps control evapotranspiration (ET), and ET variations can in turn have a distinct impact on 2-m air temperature (T2M), given that increases in evaporative cooling encourage reduced temperatures. Soil moisture is accordingly linked to T2M, and realistic soil moisture initialization has, in previous studies, been shown to improve the skill of subseasonal T2M forecasts. The relationship between soil moisture and evapotranspiration, however, is distinctly nonlinear, with ET tending to increase with soil moisture in drier conditions and to be insensitive to soil moisture variations in wetter conditions. Here, through an extensive analysis of subseasonal forecasts produced with a state-of-the-art seasonal forecast system, this nonlinearity is shown to imprint itself on T2M forecast error in the conterminous United States in two unique ways: (i) the T2M forecast bias (relative to independent observations) induced by a negative precipitation bias tends to be larger for dry initializations, and (ii) on average, the unbiased root-mean-square error (ubRMSE) tends to be larger for dry initializations. Such findings can aid in the identification of forecasts of opportunity; taken a step further, they suggest a pathway for improving bias correction and uncertainty estimation in subseasonal T2M forecasts by conditioning each on initial soil moisture state.

2-meter Temperature↗

Performance and Compliance Monitoring - Different Objectives and Different Interpretation - 19109

Environmental surveillance and monitoring are a critical part of an overall strategy for protection of the public and environment. For site closure and disposal activities, monitoring and surveillance can be expected to continue many years into the future. In the case of environmental monitoring, two general types are commonly discussed: compliance and performance (or functional) monitoring. The objective of compliance monitoring is relatively clear. Compliance monitoring is conducted to demonstrate compliance with specific regulatory limits (e.g., maximum contaminant levels in groundwater). In this case, if your measurement is above these values, it is a regulatory concern. Monitoring can be especially challenging for engineered solutions involving robust barriers expected to last for decades or potentially hundreds or thousands of years. Although some gradual releases are expected to occur as barriers lose effectiveness, observable changes in groundwater are likely to be very small and may be delayed for very long times. For robust engineered systems, compliance in the near future is not expected to be a significant concern. The question becomes, what type of monitoring can be used to identify the potential for a compliance problem in the future? This has led to increasing use of performance monitoring as an early warning system. Rather than comparing against environmental standards, performance monitoring is compared against assumptions and results from a performance assessment. Performance monitoring is used to observe other potential indicators of changes in system behavior (vadose zone concentrations, changes in chemistry near the waste, changes in engineered features). Translating a change in a local measurement to a potential change in the concentration in an aquifer that would lead to a potential compliance concern in the future is a significant challenge for performance monitoring. Such monitoring needs to be more carefully interpreted and communicated than compliance monitoring. Considerations for implementation of performance monitoring are the focus of this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding The Top-Of-Atmosphere Fluxes Difference Between Aerocom Phase III Models And The CERES Product: Clear-Sky Perspective

The Clouds and the Earth’s Radiant Energy System (CERES) project produces a long-term global climate data record (CDR) that can be used to detect decadal changes in the Earth’s radiation budget (ERB) from the surface to the top-of-atmosphere (TOA). The CERES Energy Balanced and Filled (EBAF) product includes monthly mean shortwave (SW), longwave (LW), and net TOA all-sky and clear-sky radiative fluxes over 1-degree latitude by 1-degree longitude regions. The EBAF SW and LW fluxes are adjusted within their uncertainties to be consistent with the heat storage in the Earth-atmosphere system (Johnson et al. 2016). EBAF also provides a gap-free monthly mean clear-sky flux map by inferring clear-sky fluxes from both CERES and MODIS measurements (Loeb et al. 2018). In this study, we compare the TOA clear-sky fluxes from Aerocom phase III output with those from the CERES EBAF products. Flux differences over the ocean are generally smaller than over the land, and the magnitude of the differences shows seasonal and regional dependency. To understand the flux differences, aerosol optical depths (AOD) from the Aerocom models are compared with the satellite retrievals from MODIS and MISR. Over the ocean, the AOD differences and the flux differences show consistent regional features, indicating that the differences between models and observations are robust as the CERES EBAF clear-sky SW fluxes and MODIS/MISR AODs are determined independently. However, very little resemblance is found between the AOD and flux differences over the land. To further understand the cause of the flux differences over the land, we compare the land surface albedo from MODIS with the albedo from the models and find consistency in regional albedo differences and flux differences. Monthly regional radiative kernels of AOD and surface albedo derived using the MERRA-2 reanalysis data (Thorsen et al. 2020) are applied to AOD and surface albedo differences between models and observations. For most of the models, the AOD and surface albedo differences can explain most of the flux differences between models and CERES EBAF. The EOS era satellites have provided 20 years of carefully calibrated and validated observations that are suitable for trend analysis. Both the MODIS AOD and CERES EBAF clear-sky SW flux show decreasing trends over the coastal regions of eastern China and the eastern United States due to the emission control policies enforced in both countries, and an increasing trend off the coast of India. The AOD and clear-sky SW flux trends are less consistent over land, as the surface albedo changes complicate the clear-sky SW flux trend. The AOD and clear-sky SW flux trends from the Oslo model HIST run are also examined. However, none of the aforementioned regional trends are found in the model results.

Wenying Su↗

A Proposal of Conducting Bioequivalence Trials with Gastric pH Modulators for Two Oral Formulations Demonstrating Different Dissolution Profiles at Elevated pH

In this paper, a special case for bioequivalence evaluation of oral formulations is discussed. Drug formulations with different forms of active moieties (e.g., free base and salt) may yield different dissolution characteristics and, thus, differ in absorption at elevated gastric pH . However, routine bioequivalence trials using subjects with normal gastric pH (i.e., ~ 1) may fail to identify these differences because dissolution/absorption profiles of the two formulations at normal gastric pH are similar. In the case of palbociclib, it is confirmedthat the free base and salt formulations showed different absorption in patients with different gastric pH . Significant reduction in drug absorption was observed only in patients with elevated gastric pH using free base formulation. The discovery that the free base had significantly reduced absorption hinged on the inclusion of enough patients with elevated gastric pH to detect a difference in a bioequivalence trial. This raises a concern, as demonstrated through simulation, that dissolution/absorption differences in other formulations could be missed in routine bioequivalence trials. Aside from differences in active pharmaceutical ingredients ( API s), other factors, such as changes in excipients or manufacturing methods, may also lead to exposure differences between formulations at elevated gastric pH . For formulations containing different forms of the same active moiety or the same API and showing different dissolution profiles at elevated pH (i.e., pH ~ 4–6.8), evaluation of bioequivalence with gastric pH modulators (e.g., a H 2 blocker) in addition to routine bioequivalence assessments may help to ensure therapeutic equivalence in patients with elevated gastric pH .

59 BASIC BIOLOGICAL SCIENCES↗

SAGE 2-Umkehr case study of ozone differences and aerosol effects from October 1984 to April 1989

A comparison of 1262 cases of coincident ozone profiles derived from 666 Umkehrs at 17 different stations and 901 SAGE 2 profiles within 1000 km and 12 hours between October 1984 and April 1989 indicates the following layer percentage differences with 2-sigma error bars: layer three 14.6 plus/minus 3.3 percent, layer four 17.6 plus/minus 1.1 percent, layer five -1.3 plus/minus 0.5 percent, layer six -5.7 plus/minus 0.7 percent, layer seven -1.0 plus/minus 0.7 percent, layer eight 4.2 plus/minus 0.7 percent, and layer nine 6.8 plus/minus 1.2 percent. Comparing SAGE 2-Umkehr differences to SAGE 1 version 5.5-Umkehr differences shows SAGE 2 higher than or equal to SAGE 1 relative to Umkehr in all layers except layer three. Adjustment for this bias would produce trends derived from SAGE 2-SAGE 1 differences and Umkehr observations in the 1980s more nearly equal to each other in layers six, seven, and eight. A possible explanation of these differences is a systematic shift in the reference altitude between SAGE 1 and SAGE 2, but there is no independent evidence of this. While the shape of the vertical profile of differences at 17 individual Umkehr stations (mostly in mid-latitudes) is generally consistent at all stations except at Poker Flat, Seoul, and Lauder, significant variation does exists among the stations. The profile of mean difference is similar to previously observed differences between Umkehr and both SAGE 2 and SBUV and also to an eigenvector analysis, but with site-dependent amplitude discrepancies. Because of the close correspondence of stratospheric aerosol optical depth at the SAGE 2-measured 0.525 micron wavelength and the extrapolated 0.32 Umkehr wavelength determined in this study, we use the 0.525 micron data to determine the aerosol effect of Umkehr profiles. The aerosol errors to the Umkehr ozone amounts in percent ozone amount per 0.01 stratospheric aerosol optical depth range from plus 2 percent in layer six to minus 3 percent in layer nine. These results agree with previous theoretical and empirical studies within their respective error bounds in layers nine, eight, and five. The result in layer six differs significantly from previous works. In view of the fact that SAGE 2 and Umkehr produce different ozone retrievals in layers eight and nine and because the intra-layer correlation of SAGE 2 ozone and aerosol in layers eight and nine in non-zero, one must exercise some caution in attributing the entire SAGE 2-Umkehr differences in the upper layers to an aerosol effect.

Newchurch, M. J.↗

Understanding Differences in the Response to Composition Change as Simulated by CCMVal Models

Chemistry climate models (CCMs) have a common conceptual basis. Differences in implementation lead to differences in the stratospheric ozone response to changes in composition and climate. Although evaluation by CCMVal-2 identified strengths and weaknesses of participant models, the evaluation results were not used to discriminate among projections for future ozone evolution, at least in part because the overall diagnostic evaluation did not cleanly relate to the differences in CCM response. Here we use a subset of CCMVal diagnostics and additional analysis to understand the differences in response. In the upper stratosphere, differences in simulated temperature and total odd nitrogen prior to increases in chlorine loading explain the large differences in CCM sensitivity. In the lower atmosphere, there are two principle contributions to differences in CCM sensitivity to chlorine and climate change. First, differences in the lower stratospheric ClO affect simulated sensitivity to chlorine. CCMs with best transport performance match NDACC column HCl measurements at a broad range of latitudes. Other CCMs disagree with observations due to differences in total inorganic chlorine, partitioning between HCl and ClONO2, or both. Differences in ClONO2 are directly related to differences in simulated ClO. Second, although all CCMs predict increased tropical upwelling, the rate of increase varies and contributes to differences in tropical ozone and the 60N-60S column average.

Douglass, Anne R.↗

S-NPP and N20 VIIRS RSB Bands Detector-to-Detector Calibration Differences Assessment Using a Homogeneous Ground Target

The S-NPP and N20 satellites have successfully operated since their launches on October 28, 2011 and November 18, 2017, respectively. This paper provides an assessment of the detector calibration stability for the reflective solar bands (RSBs) observed from both S-NPP and N20 VIIRS. Top-of-atmosphere radiances from near-nadir observations over the homogeneous Libya 4 desert site are extracted from the S-NPP VIIRS Collection 1 and N20 Collection 2 Level-1B products. The radiances from individual detectors per Half‐angle Mirror side are studied. The comparisons of the normalized radiance to all detector average values indicate that the detector calibration differences are wavelength dependent. The S-NPP detector differences have been slowly increasing in the past 8.5 years and bands M1-M4 have 1.3%- 2.2% detector differences in 2019. N20 detector differences are stable and small in the past two years except SWIR M bands. N20 M10 and M11 have 1.3% and 2.1% detector differences, respectively. S-NPP DNB detector differences are about 0.8% and N20 DNB detector differences are about 0.5%. Most bands HAM side differences are less than 0.25% in the past years except N20 VIIRS M1 HAM side differences are 0.57% in 2018 and 0.54% in 2019. The Libya 4 images have small but noticeable striping in S-NPP M1-M4 data as well as in N20 M1, M8, M10, and M11 data. These study results have been applied in the S-NPP Collection 2 new algorithm to remove the detector differences. This research help scientists and VIIRS users better understand detector calibration differences in different version VIIRS products.

Libya 4↗

METALLICITY DIFFERENCES IN TYPE Ia SUPERNOVA PROGENITORS INFERRED FROM ULTRAVIOLET SPECTRA

Two ''twin'' Type Ia supernovae (SNe Ia), SNe 2011by and 2011fe, have extremely similar optical light-curve shapes, colors, and spectra, yet have different ultraviolet (UV) continua as measured in Hubble Space Telescope spectra and measurably different peak luminosities. We attribute the difference in the UV continua to significantly different progenitor metallicities. This is the first robust detection of different metallicities for SN Ia progenitors. Theoretical reasoning suggests that differences in metallicity also lead to differences in luminosity. SNe Ia with higher progenitor metallicities have lower {sup 56}Ni yields and lower luminosities for the same light-curve shape. SNe 2011by and 2011fe have different peak luminosities ({Delta}M{sub V} Almost-Equal-To 0.6 mag), which correspond to different {sup 56}Ni yields: M{sub 11fe}({sup 56}Ni) / M{sub 11by}({sup 56}Ni) = 1.7{sup +0.7}{sub -0.5}. From theoretical models that account for different neutron-to-proton ratios in progenitors, the differences in {sup 56}Ni yields for SNe 2011by and 2011fe imply that their progenitor stars were above and below solar metallicity, respectively. Although we can distinguish progenitor metallicities in a qualitative way from UV data, the quantitative interpretation in terms of abundances is limited by the present state of theoretical models.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-577: Comparison of Small Field Dosimetry Measurements in Fields Shaped with Conical Applicators On Two Different Accelerating Systems

Purpose: To investigate small field dosimetry measurements and associated uncertainties when conical applicators are used to shape treatment fields from two different accelerating systems. Methods: Output factor measurements are made in water in beams from the CyberKnife radiosurgery system, which uses conical applicators to shape fields from a (flattening filter-free) 6 MV beam, and in a 6 MV beam from the Elekta Precise linear accelerator (with flattening filter) with BrainLab external conical applicators fitted to shape the field. The measurements use various detectors: (i) an Exradin A16 ion chamber, (ii) two Exradin W1 plastic scintillation detectors, (iii) a Sun Nuclear Edge diode, and (iv) two PTW microDiamond synthetic diamond detectors. Profiles are used for accurate detector positioning and to specify field size (FWHM). Output factor measurements are corrected with detector specific correction factors taken from the literature where available and/or from Monte Carlo simulations using the EGSnrc code system. Results: Differences in measurements of up to 1.7% are observed with a given detector type in the same beam (i.e., intra-detector variability). Corrected results from different detectors in the same beam (inter-detector differences) show deviations up to 3 %. Combining data for all detectors and comparing results from the two accelerators results in a 5.9% maximum difference for the smallest field sizes (FWHM=5.2–5.6 mm), well outside the combined uncertainties (∼1% for the smallest beams) and/or differences among detectors. This suggests that the FWHM of a measured profile is not a good specifier to compare results from different small fields with the same nominal energy. Conclusion: Large differences in results for both intra-detector variability and inter-detector differences suggest potentially high uncertainties in detector-specific correction factors. Differences between the results measured in circular fields from different accelerating systems provide insight into sources of variability in small field dosimetric measurements reported in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

Factors correlating with significant differences between X-ray structures of myoglobin

Conformational differences between myoglobin structures are studied. Most structural differences in whale myoglobin beyond the uncertainty threshold can be correlated with a few specific structural factors. There are always exceptions and a search for additional factors is needed. The results might have serious implications for biological insights from conformational differences. Validation of general ideas about the origins of conformational differences in proteins is critical in order to arrive at meaningful functional insights. Here, principal component analysis (PCA) and distance difference matrices are used to validate some such ideas about the conformational differences between 291 myoglobin structures from sperm whale, horse and pig. Almost all of the horse and pig structures form compact PCA clusters with only minor coordinate differences and outliers that are easily explained. The 222 whale structures form a few dense clusters with multiple outliers. A few whale outliers with a prominent distortion of the GH loop are very similar to the cluster of horse structures, which all have a similar GH-loop distortion apparently owing to intermolecular crystal lattice hydrogen bonds to the GH loop from residues near the distal histidine His64. The variations of the GH-loop coordinates in the whale structures are likely to be owing to the observed alternative intermolecular crystal lattice bond, with the change to the GH loop distorting bonds correlated with the binding of specific ‘unusual’ ligands. Such an alternative intermolecular bond is not observed in horse myoglobins, obliterating any correlation with the ligands. Intermolecular bonds do not usually cause significant coordinate differences and cannot be validated as their universal cause. Most of the native-like whale myoglobin structure outliers can be correlated with a few specific factors. However, these factors do not always lead to coordinate differences beyond the previously determined uncertainty thresholds. The binding of unusual ligands by myoglobin, leading to crystal-induced distortions, suggests that some of the conformational differences between the apo and holo structures might not be ‘functionally important’ but rather artifacts caused by the binding of ‘unusual’ substrate analogs. The causes of P6 symmetry in myoglobin crystals and the relationship between crystal and solution structures are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A spatially encoded dose difference maximal intensity projection map for patient dose evaluation: A new first line patient quality assurance tool

Purpose: To develop a spatially encoded dose difference maximal intensity projection (DD-MIP) as an online patient dose evaluation tool for visualizing the dose differences between the planning dose and dose on the treatment day. Methods: Megavoltage cone-beam CT (MVCBCT) images acquired on the treatment day are used for generating the dose difference index. Each index is represented by different colors for underdose, acceptable, and overdose regions. A maximal intensity projection (MIP) algorithm is developed to compress all the information of an arbitrary 3D dose difference index into a 2D DD-MIP image. In such an algorithm, a distance transformation is generated based on the planning CT. Then, two new volumes representing the overdose and underdose regions of the dose difference index are encoded with the distance transformation map. The distance-encoded indices of each volume are normalized using the skin distance obtained on the planning CT. After that, two MIPs are generated based on the underdose and overdose volumes with green-to-blue and green-to-red lookup tables, respectively. Finally, the two MIPs are merged with an appropriate transparency level and rendered in planning CT images. Results: The spatially encoded DD-MIP was implemented in a dose-guided radiotherapy prototype and tested on 33 MVCBCT images from six patients. The user can easily establish the threshold for the overdose and underdose. A 3% difference between the treatment and planning dose was used as the threshold in the study; hence, the DD-MIP shows red or blue color for the dose difference >3% or {<=}3%, respectively. With such a method, the overdose and underdose regions can be visualized and distinguished without being overshadowed by superficial dose differences. Conclusions: A DD-MIP algorithm was developed that compresses information from 3D into a single or two orthogonal projections while hinting the user whether the dose difference is on the skin surface or deeper.

60 APPLIED LIFE SCIENCES↗

SU-E-T-562: Scanned Percent Depth Dose Curve Discrepancy for Photon Beams with Physical Wedge in Place (Varian IX) Using Different Sensitive Volume Ion Chambers

Purpose: To investigate and report the discrepancy of scanned percent depth dose (PDD) for photon beams with physical wedge in place when using ion chambers with different sensitive volumes. Methods/Materials: PDD curves of open fields and physical wedged fields (15, 30, 45, and 60 degree wedge) were scanned for photon beams (6MV and 10MV, Varian iX) with field size of 5x5 and 10x10 cm using three common scanning chambers with different sensitive volumes - PTW30013 (0.6cm3), PTW23323 (0.1cm3) and Exradin A16 (0.007cm3). The scanning system software used was OmniPro version 6.2, and the scanning water tank was the Scanditronix Wellhoffer RFA 300.The PDD curves from the three chambers were compared. Results: Scanned PDD curves of the same energy beams for open fields were almost identical between three chambers, but the wedged fields showed non-trivial differences. The largest differences were observed between chamber PTW30013 and Exradin A16. The differences increased as physical wedge angle increased. The differences also increased with depth, and were more pronounced for 6MV beam. Similar patterns were shown for both 5x5 and 10x10 cm field sizes. For open fields, all PDD values agreed with each other within 1% at 10cm depth and within 1.62% at 20 cm depth. For wedged fields, the difference of PDD values between PTW30013 and A16 reached 4.09% at 10cm depth, and 5.97% at 20 cm depth for 6MV with 60 degree physical wedge. Conclusion: We observed a significant difference in scanned PDD curves of photon beams with physical wedge in place obtained when using different sensitive volume ion chambers. The PDD curves scanned with the smallest sensitive volume ion chamber showed significant difference from larger chamber results, beyond 10cm depth. We believe this to be caused by varying response to beam hardening by the wedges.

07 ISOTOPE AND RADIATION SOURCES↗