Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex, scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuSD: A Geant4 based simulation framework for segmented anti-neutrino detectors

NuSD: Neutrino Segmented Detector is a Geant4-based user application that simulates inverse beta decay event in a variety of segmented scintillation detectors developed by different international collaborations. This simulation framework uses a combination of cross-programs and libraries including Geant4, ROOT and CLHEP developed and used by high energy physics community. It will enable the neutrino physics community to simulate and study neutrino interactions within different detector concepts using a single program. In addition to neutrino simulations in segmented detectors, this program can also be used for various research projects that use of scintillation detectors for different physics purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal ''image-based'' weighting for energy-resolved CT

This paper investigates a method of reconstructing images from energy-resolved CT data with negligible beam-hardening artifacts and improved contrast-to-nosie ratio (CNR) compared to conventional energy-weighting methods. Conceptually, the investigated method first reconstructs separate images from each energy bin. The final image is a linear combination of the energy-bin images, with the weights chosen to maximize the CNR in the final image. The optimal weight of a particular energy-bin image is derived to be proportional to the contrast-to-noise-variance ratio in that image. The investigated weighting method is referred to as ''image-based'' weighting, although, as will be described, the weights can be calculated and the energy-bin data combined prior to reconstruction. The performance of optimal image-based energy weighting with respect to CNR and beam-hardening artifacts was investigated through simulations and compared to that of energy integrating, photon counting, and previously studied optimal ''projection-based'' energy weighting. Two acquisitions were simulated: dedicated breast CT and a conventional thorax scan. The energy-resolving detector was simulated with five energy bins. Four methods of estimating the optimal weights were investigated, including task-specific and task-independent methods and methods that require a single reconstruction versus multiple reconstructions. Results demonstrated that optimal image-based weighting improved the CNR compared to energy-integrating weighting by factors of 1.15-1.6 depending on the task. Compared to photon-counting weighting, the CNR improvement ranged from 1.0 to 1.3. The CNR improvement factors were comparable to those of projection-based optimal energy weighting. The beam-hardening cupping artifact increased from 5.2% for energy-integrating weighting to 12.8% for optimal projection-based weighting, while optimal image-based weighting reduced the cupping to 0.6%. Overall, optimal image-based energy weighting provides images with negligible beam-hardening artifacts and improved CNR compared to energy-integrating and photon-counting methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The GlueX Start Counter Detector

The design, simulation, fabrication, calibration, and performance of the GlueX Start Counter detector is described. The Start Counter was designed to operate at integrated rates of up to 9 MHz with a timing resolution in the range of 500 to 825 ps (FWHM). The Start Counter provides excellent solid angle coverage, a high degree of segmentation for background rejection, and can be utilized in the level 1 trigger for the experiment. It consists of a cylindrical array of 30 thin scintillators with pointed ends that bend towards the beam line at the downstream end. Magnetic field insensitive silicon photomultiplier detectors were used as the light sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

Final Report of the Simulation Optimization Task Force

This is the final report of the ATLAS Simulation Optimization Task Force, establishedin June of 2007. This note justifies the selected Geant4 version, physics list, and range cuts to be used by the default ATLAS simulation for initial data taking and beyond. The current status of several projects, including detector description, simulation validation, studies of additional Geant4 parameters, and cavern background, are reported.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNPX Simulation Study of STRAW Neutron Detectors

A novel prototype fission meter is being designed at National Security Technologies, LLC, using a thin uniform coating (only 1 micron thick) of {sup 10}B as a neutron converter inside a large array of thin (4 mm diameter) copper tubes. The copper tubes are only 2 mils thick, and each holds the stretched anode wire under tension and high voltage. The tubes are filled with proportional counter gas (a mixture of 90%/10% of Ar/CO{sub 2}). The tubes operate in proportional counter mode and attract mobile charged particles ({alpha}'s) created in the nuclear interaction {sup 10}B(n, {sup 4}He){sup 7}Li. However, a single tube has about 1/7th the sensitivity of a {sup 3}He tube. Modeling is required to determine if enough such tubes could be placed in a neutron detection assembly of the current size to give comparable sensitivity to {sup 3}He. Detectors lined with {sup 10}B lie between {sup 3}He and {sup 10}BF{sub 3} proportional counters and fission chambers in terms of neutron detection efficiency and gamma ray insensitivity. The mean free path of thermal neutrons in {sup 10}B is about 18 {micro}m. It takes about 60 {micro}m of {sup 10}B layer to completely stop thermal neutrons, but the energetic {alpha}-particles generated in the reaction have a range of only 3.3 {micro}m in {sup 10}B environment - hence the thin layer of boron coating on the copper tube. The prototype design is shown in Figure 1. It consists of two panels of three staggered rows of 500-mm-long, 4-mm-diameter straws, with 20 in each row, embedded in 30-mm-thick high density polyethylene (HDPE). The project demonstrates a new application of thin neutron and gamma converter technique (1 micron thin {sup 10}B coated copper tube). It exploits fast timing from multiple straw detectors to count multiplicity of both gamma and neutrons from fissioning materials. The objective is to find a near-term replacement of {sup 3}He gas in neutron detection and measurement (with a very large neutron detection area). All the solid-state detectors developed thus far are small and inefficient. The thin size of the straws provides imaging capability with high enough resolution for radiation emitting sources. The prototype will provide the first aerial neutron detection system with directional sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of Electric Field in Semi Insulating Au/CdTe/Au Detector under Flux

We report our simulations on the profile of the electric field in semi insulating CdTe and CdZnTe with Au contacts under radiation flux. The type of the space charge and electric field distribution in the Au/CdTe/Au structure is at high fluxes result of a combined influence of charge formed due to band bending at the electrodes and from photo generated carriers, which are trapped at deep levels. Simultaneous solution of drift-diffusion and Poisson equations is used for the calculation. We show, that the space charge originating from trapped photo-carriers starts to dominate at fluxes 10{sup 15}-10{sup 16}cm{sup -2}s{sup -1}, when the influence of contacts starts to be negligible.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Examination of simulated behavior of ND-LAr and TMS detectors using CAFAna for DUNE analysis framework

Simulations are run using the new DUNE CAFAna framework to generate pseudo-data modeling the interactions of neutrinos in the DUNE near detector at truth-level and detector-level. Truth-level analysis of neutrino kinematics reveals strong agreement with expected behavior, validating the kinematic portion of the simulation. Examination of the detector-level reconstructions of coordinates of interaction vertex appear consistent with an interaction density independent of detector position. Track lengths of particles resultant from neutrino interactions are aligned with varied particle identities, but are misaligned with prediction of uniform position density.

Fein, Jarrett [Fermilab]↗

Development of two-band infrared radiometer for irradiance calibration of target simulators

A detector-based spectral radiometer has been developed for the calibration of target simulator. Unlike the conventional spectral irradiance calibration method based on radiance and irradiance, the new radiometer is calibrated using image-space temperature based method. The image-space temperature based method improves the reproducibility in the calibration of radiometer and reduces the uncertainties existing in the conventional calibration methods. The calibrated radiometer is then used to establish the irradiance transfer standard for the target simulator. With the designed radiometer in this paper, a highly accurate irradiance calibration for target simulators of wavelength from 2.05 to 2.55 μm and from 3.7 to 4.8 μm can be performed with an expanded uncertainty (k = 2) of calibration of 2.18%. Last but not least, the infrared radiation of the target simulator was measured by the infrared radiometer, the effectiveness and capability of which are verified through measurement of temperature and irradiance and a comparison with the thermal imaging camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Magnetic Fields on LArTPCs, ArCS

ArCS is implementing magnetic fields to LarTPC detectors in order to develope their ability to do charge separation. This poster shows two algorithms that take simulated LarTPC detectors with magnetic fields, and compares their performance as a function of magnetic field and momentum in order to establish what field is needed for charge separation to work well.

Lopez, Alex [U. Chicago (main)]↗

Artificial Intelligence for Event Reconstruction and Higgs Physics at CMS and Future Colliders

This dissertation charts a trajectory in which advances in artificial intelligence (AI) play a central role in pushing the high-energy physics frontier, complementing progress driven by higher collision energies and larger colliders. The discovery potential of the LHC and future colliders relies on accurate reconstruction of increasingly complex particle collision events. In the CMS experiment, this task is performed by the particle-flow (PF) algorithm. This dissertation presents the first implementation of a machine-learning-based particle-flow (MLPF) reconstruction in the CMS detector based on transformer architectures. In simulated top quark--antiquark pair (ttbar) events under LHC Run~3 (2023--2024) conditions, MLPF improves jet energy resolution by 10--20\% compared to standard PF for jets with transverse momentum between 30--100\GeV. Runtime performance is evaluated using simulated multijet events, with a median inference time of 20\unit{ms} per event on an NVIDIA L4 GPU, compa red to approximately 110\unit{ms} for standard PF. The MLPF algorithm is also validated on Run~3 collision data, representing the first data-validated ML-based reconstruction pipeline at any LHC experiment. We then extend MLPF toward future electron--positron colliders and introduce the first full-simulation cross-detector transfer learning workflow for PF reconstruction. The model is pre-trained on simulated events from the Compact Linear Collider detector (CLICdet) and fine-tuned on the CLIC-like detector (CLD) proposed for the Future Circular Collider (FCC). This approach achieves up to a 40\% improvement in jet energy resolution over rule-based reconstruction while reducing the required training dataset size by an order of magnitude, demonstrating the potential of AI to accelerate detector development and optimization. This dissertation also demonstrates how modern AI techniques enhance the sensitivity of LHC physics analyses. A CMS search for highly Lorentz-boosted Higgs bosons decaying to \textrm{W} boson pairs is presented, focusing on the single-lepton final state. A dedicated fine-tuning strategy for \ParT yields an approximately 70\% increase in expected sensitivity relative to the baseline model. The analysis uses proton--proton collision data at a center-of-mass energy of \ensuremath{\sqrt{s}=13\TeV} collected by CMS between 2016 and 2018, corresponding to an integrated luminosity of 138\ensuremath{\ \mathrm{fb}^{-1}}. The expected significance of the search is $1.86\sigma$, with an observed signal strength of $-0.19^{+0.48}_{-0.46}$. Finally, explainable AI techniques are applied to the MLPF and \ParticleNet algorithms using layerwise relevance propagation, showing that both models base their predictions on physically meaningful features consistent with our physics intuition. Together, these results demonstrate how advanced AI methods can enhance reconstruction, analysis sensitivity, and interpretability, shaping the next era of experimental parti cle physics.

Mokhtar, Farouk [UC, San Diego]↗

A bismuth germanate-shielded mercuric iodide X-ray detector for space applications

The development of HgI2 for solid state X-ray detector applications over the past decade was carried out in connection with the ability of the crystal to operate as a detector at room temperature. In order to achieve the lowest background possible for HgI2 detectors in a space-like environment (balloon and/or satellite altitudes), attention was given to the design of a shielding system which actively vetoes nonaperture events such as gamma rays and charged particles that can mimic signal X-rays by partial deposition of energy in the main detector. The detector system consists of two HgI2 detectors mounted back to back and operated in anticoincidence. The two detectors are placed inside a bismuth germanate scintillating shield along with two hybrid charge-sensitive preamps. Monte Carlo simulations of detector performance are discussed.

Vallerga, J. V.↗

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time averaged. Simulations were computed for freestream velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics↗

Simulation of Fluid Flow and Collection Efficiency for a SEA Inc. Multi-Element Probe and Ice Crystal Detector Using GlennICE

Numerical simulation results of fluid flow and collection efficiency of the Science Engineering Associates Inc. Multi-Element Probe (Multiwire) and Ice Crystal Detector (ICD) are presented. Fluid flow simulations were conducted using NASA's FUN3D while collection efficiency simulations were conducted using NASA's LEWICE3D software and GlennICE software. For both probes, 3D unsteady flow results were time-averaged. Simulations were computed for free steam velocities ranging from 85 to 185 m/s and freestream total pressures of 44.8 and 93.1 kPa. Collection efficiency results were computed for four spherical particle diameter sizes of 5, 20, 50, and 100 µm. GlennICE collection efficiency results for the multiwire were compared with previously published collection efficiency values calculated using LEWICE3D. Numerical collection efficiency results for the Ice Crystal Detector are presented for the first time.

aircraft, icing, Computational Fluid Dynamics↗

J/{psi} Production with NRQCD: HERA, Tevatron, RHIC and LHC

We report on our recent calculation of the inclusive direct photo- and hadroproduction of the J/{psi} meson at next-to-leading order within the factorization formalism of nonrelativistic QCD. We fit the color-octet (CO) long-distance matrix elements <O{sup J}/{psi}(1S{sub 0}{sup [8]})>, <O{sup J}/{psi}(3S{sub 1}{sup [8]})> and <O{sup J}/{psi}(3P{sub 0}{sup [8]})> to the transverse momentum (p{sub T}) distributions measured by CDF at Fermilab Tevatron and by H1 at DESY HERA and show that they also successfully describe the p{sub T} distributions from PHENIX at BNL RHIC and CMS at the CERN LHC as well as the photon-proton c.m. energy and (with worse agreement) the inelasticity distributions from H1. In all experiments, the CO processes are shown to be indispensable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CZT detectors used in different irradiation geometries: Simulations and experimental results

The purpose of this work was to evaluate potential advantages and limitations of CZT detectors used in surface-on, edge-on, and tilted angle irradiation geometries. Simulations and experimental investigations of the energy spectrum measured by a CZT detector have been performed using different irradiation geometries of the CZT. Experiments were performed using a CZT detector with 10x10 mm{sup 2} size and 3 mm thickness. The detector was irradiated with collimated photon beams from Am-241 (59.5 keV) and Co-57 (122 keV). The edge-scan method was used to measure the detector response function in edge-on illumination mode. The tilted angle mode was investigated with the radiation beam directed to the detector surface at angles of 90 degree sign , 15 degree sign , and 10 degree sign . The Hecht formalism was used to simulate theoretical energy spectra. The parameters used for simulations were matched to experiment to compare experimental and theoretical results. The tilted angle CZT detector suppressed the tailing of the spectrum and provided an increase in peak-to-total ratio from 38% at 90 degree sign to 83% at 10 degree sign tilt angle for 122 keV radiation. The corresponding increase for 59 keV radiation was from 60% at 90 degree sign to 85% at 10 degree sign tilt angle. The edge-on CZT detector provided high energy resolution when the beam thickness was much smaller than the thickness of CZT. The FWHM resolution in edge-on illumination mode was 4.2% for 122 keV beam with 0.3 mm thickness, and rapidly deteriorated when the thickness of the beam was increased. The energy resolution of surface-on geometry suffered from strong tailing effect at photon energies higher than 60 keV. It is concluded that tilted angle CZT provides high energy resolution but it is limited to a 1D linear array configuration. The surface-on CZT provides 2D pixel arrays but suffers from tailing effect and charge build up. The edge-on CZT is considered suboptimal as it requires small beam thickness and also suffers from charge buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low dose simulation tool for CT systems with energy integrating detectors

Purpose: This paper introduces a new strategy for simulating low-dose computed tomography (CT) scans using real scans of a higher dose as an input. The tool is verified against simulations and real scans and compared to other approaches found in the literature. Methods: The conditional variance identity is used to properly account for the variance of the input high-dose data, and a formula is derived for generating a new Poisson noise realization which has the same mean and variance as the true low-dose data. The authors also derive a formula for the inclusion of real samples of detector noise, properly scaled according to the level of the simulated x-ray signals. Results: The proposed method is shown to match real scans in number of experiments. Noise standard deviation measurements in simulated low-dose reconstructions of a 35 cm water phantom match real scans in a range from 500 to 10 mA with less than 5% error. Mean and variance of individual detector channels are shown to match closely across the detector array. Finally, the visual appearance of noise and streak artifacts is shown to match in real scans even under conditions of photon-starvation (with tube currents as low as 10 and 80 mA). Additionally, the proposed method is shown to be more accurate than previous approaches (1) in achieving the correct mean and variance in reconstructed images from pure-Poisson noise simulations (with no detector noise) under photon-starvation conditions, and (2) in simulating the correct noise level and detector noise artifacts in real low-dose scans. Conclusions: The proposed method can accurately simulate low-dose CT data starting from high-dose data, including effects from photon starvation and detector noise. This is potentially a very useful tool in helping to determine minimum dose requirements for a wide range of clinical protocols and advanced reconstruction algorithms.

60 APPLIED LIFE SCIENCES↗