Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Constraining Absolute Higgs Couplings using Vector Boson Fusion H to WW with FCC-hh

The absolute normalisation scale of Higgs couplings is difficult to determine in hadron colliders. An experimentally and theoretically clean way to establish the coupling scale is to measure the ratio of resonant Vector Boson Fusion $H \rightarrow WW^{*}$ production to non-resonant $qq \rightarrow qqWW$ because both the theoretical and detector response systematics all cancel to first order in the ratio. To set the scale of the sensitivity, a simple selection and fit is presented with gives a 1.8\% (1.9\%) statistical uncertainty on the ratio for a 100 (84) TeV FCC-hh at 30\,ab$^{-1}$, which would give a corresponding uncertainty on the $\kappa$ scale of 0.5-1\% depending on systematic effects and potential impacts of more sophisticated analysis.

Lipeles, Elliot [University of Pennsylvania] (ORCI↗

Search for low mass WIMP dark matter with DarkSide-50

DarkSide-50 is a direct dark matter detection experiment at Laboratori Nazionali del Gran Sasso that uses argon as the target material. Exploiting the ionization signal from a dual-phase time projection chamber filled with low-radioactivity argon, it has set the most stringent exclusion limit on WIMPs with a mass of few \mathrm{GeV}/c^2 G e V / c 2 . A new analysis has recently been carried out with a larger exposure, profiting from an improved understanding of the detector response and background model. An improvement of about a factor 10 in sensitivity is expected for a WIMP mass of 2 GeV/c ^2 2 .

Kimura, Masato↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subcritical Multiplication Ex-Core Calculations with Shift

This report details the development and testing of Virtual Environment for Reactor Applications (VERA) as applied to full core subcritical multiplication ex-core calculations with Shift. The limiting factor in being able to run these detector calculations with Monte Carlo is the amount of computational memory used by a fully-loaded full core problem. The main development features added to VERA in this effort were enabling source biasing and separable weight windows and integrating multithreading in Shift. With these capabilities, a subcritical multiplication detector response calculation on a full core Watts Bar Nuclear Plant Unit 1 (WBN1) ex-core model was successfully run on a moderately sized computing cluster.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a High-Energy Neutron Sniffer and Subsequent Dose Quantification for High-Energy Particle Accelerator Shielding Surveys

The objective of this research is to design a portable neutron detector that is lightweight and responds to neutrons with energies of 20 MeV and greater. The instrument will be used as a ‘sniffer’ probe for identifying shielding weaknesses at high-energy particle accelerators and be paired with a plastic scintillator to quantify the high-energy neutron dose equivalent. The sniffer probes are two different sizes and comprised of either cesium iodide or sodium iodide, all doped with thallium, making a total of four detectors. The probes were calibrated to respond only to radiations with 8 MeV electron equivalent energy or higher, vastly reducing detector response from background and lower energy radiations. The sniffer probes were tested using californium- 252 and americium-beryllium sources, followed by high-energy (up to 800 MeV) neutron exposures at the Los Alamos Neutron Science Center Weapons Neutron Research (WNR) facility. The sniffer probes were then used to identify areas around the accelerator facility where elevated levels of high-energy radiation was present and the plastic scintillators were placed in these locations to determine the high-energy neutron dose equivalent. The dose equivalent is calculated by measuring the 12 C(n,2n) 11 C reaction, which has a 20.4 MeV neutron threshold. Two locations behind the WNR facility were identified with the probes and the dose equivalent rates from neutron energies above 20 MeV were calculated to be 1.24 mrem/h behind flightpath 30-left and 1.53 behind flightpath 30-right. Of the four sniffer probes, the 2-inch x 2-inch cesium iodide is the recommended probe for performing high-energy shielding surveys. The larger crystal size yields higher sensitivity at lower count rates and the more dense material increases the likelihood of interaction within the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time data reduction at 100 Tbps: Challenge and opportunity for AI-based data reduction for next-generation large-scale nuclear physics collider experiment

The modern large-scale nuclear physics (NP) experiments in high-energy particle colliders utilize streaming-readout electronics to digitize detector response at O(100) Tbps bandwidth. Prominent examples at Brookhaven National Lab (BNL) include the sPHENIX experiment at Relativistic Heavy Ion Collider (RHIC), which is under construction, and the experiments proposed for the Electron-Ion Collider (EIC), planned for the 2030s . One of the main challenges for these streaming readout systems is to manage the data rate with sufficient data reduction in real time so the end-data fit persistent storage for offline analysis, which is typically at O(1000) times smaller and O(100) Gbps. Such data reduction traditionally is achieved via real-time high level triggers, which select and save a small subset of collisions of interest. Although triggering is applicable to high energy collider experiments such as those at the Large Hardron Collider at CERN, it is insufficient for these nuclear physics experiments which study diverse collision topologies. And traditional triggering approach is inefficient to preserve the max information harvested from the operation of colliders that costs O(100)M per year to DOE. Meanwhile, in recent years, ML-based high-throughput data reduction has emerged as a promising approach to efficiently preserve max information for a given space of persistent storage, e.g. via AI data compression, feature extraction, and noise filtering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VERA-Grizzly Ex-Core Calculations: Watts Bar Unit 1 Cycles 1-2

The critical structures that comprise light-water reactor (LWR) nuclear power plants are subjected to operating environments that can challenge their integrity. Structures in close proximity to the reactor core, such as the reactor pressure vessel (RPV) and the biological shield wall, are subjected to high levels of radiation emanating from the core, as well as elevated temperatures. As the US fleet of operating LWRs ages, the effects of these operating environments on the integrity of these structures must be considered to ensure their continued safe operation. Extending the lifetime of commercial reactors and maintaining the aging reactor fleet require accurate prediction of the exposure of ex-core components to neutron and photon radiation. In particular, concrete degradation studies must be performed to evaluate the safety and long-term operation of reactors with lifetime extensions. The concrete reactor bioshield is important for providing radiological protection during operation and must last for the entire lifetime of the reactor. Recent interest in lifetime extensions furthers the need to accurately simulate concrete material degradation in the reactor bioshield. As a result of this need, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has funded this study to couple its tools, Virtual Environment for Reactor Applications (VERA) and Grizzly. VERA allows users to set up models to calculate time-dependent and fully coupled solutions (with thermal feedback) for ex-core quantities of interest such as vessel and coupon fluence and detector responses for multiple statepoints and cycles. Grizzly is a finite-element application based on the Multiphysics Object Oriented Simulation Environment (MOOSE) framework that is used to enable aging materials calculations. This report highlights the work performed to calculate the fluence in the vessel and concrete for Watts Bar Nuclear Plant Unit 1 (WBN1) Cycles 1 and 2. The fluences obtained from VERA were successfully transferred to Grizzly using a Python script. Four simulations were run with Grizzly: (1) the Mazars model with the initial Young’s modulus being the instantaneous modulus, (2) the Mazars model with the initial Young’s modulus being the delayed modulus, (3) the Mazars model with the initial Young’s modulus being the delayed modulus with the addition of the effects of micro-damage caused by irradiation, and (4) the Mazars model with the initial Young’s modulus being the instantaneous modulus, and with the addition of micro-damage and creep. Details regarding the methods used to obtain the fluence and the statistical errors associated with the VERA Monte Carlo Shift calculations are discussed in greater detail in this report. The results obtained from the four Grizzly models are also presented in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Data to Reduce Uncertainties in Reactor Antineutrino Measurements

The large quantities of antineutrinos produced through the decay of fission fragments in nuclear reactors provide an opportunity to study the properties of these particles and investigate their use in reactor monitoring. The reactor antineutrino spectra are measured using specialized, large area detectors that detect antineutrinos through inverse beta decay, electron elastic scattering, or coherent elastic neutrino nucleus scattering; although, inverse beta decay is the only demonstrated method so far. Reactor monitoring takes advantage of the differences in the antineutrino yield and spectra resulting from uranium and plutonium fission providing an opportunity to estimate the fissile material composition in the reactor. Recent experiments reveal a deviation between the measured and calculated antineutrino flux and spectra (the reactor anomaly) indicating either the existence of yet undiscovered neutrino physics, uncertainties in the reactor source term calculation, incorrect nuclear data, or a combination of all three. To address the nuclear data that impact the antineutrino spectrum calculations and measurements, an international group of over 180 experts in antineutrino physics, reactor analysis, detector development, and nuclear data came together during the Workshop on Nuclear Data for Reactor Antineutrino Measurements (WoNDRAM) to discuss nuclear data needs and achieve concordance on a set of recommended priorities for nuclear data improvements. Three topical sessions focused on the reactor source term, the antineutrino spectrum, and the detector response, provided a forum to gain consensus amongst the participants on the most important data improvements to address two goals: 1) understand the reactor anomaly and 2) improve the ability to monitor reactors using antineutrinos. This report summarizes the outcomes of the workshop discussions and the recommendations for nuclear data efforts that reduce reactor antineutrino measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coincident Capture through Post-processing PTRAC [Slides]

This presentation discusses the new PTRAC capabilities and workflows. The PTRAC capability in MCNP6.3 has seen a massive overhaul since MCNP6.2. The new HDF5 file format allows for both MPI- and thread-based parallelism. MCNPTools has been updated to handle the new HDF5 PTRAC format and is now open sourced on GitHub. Built-in capabilities, such as the pulse-height tally coincident capture special treatment, can largely be replicated through separate postprocessing scripts that leverage both PTRAC and MCNPTools. This allows for greater flexibility in user-specified and controlled detector response functionality, ultimately using the MCNP code for what it is best at (i.e., particle transport).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oak Ridge National Laboratory Official TM Cover: Development and Qualification of Tungsten Reference Materials for LA-ICP-MS

Reference materials have been developed to provide areal density measurements of tungsten that is deposited on graphite when using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Several reference materials of varying areal densities have been produced using a magnetron sputtering, thin film deposition technique. With multiple reference materials that have varying areal densities, a calibration curve has been developed for translating the detector response of an ICP-MS into a quantitative measurement. These results provide the opportunity to make calibrated comparisons across graphite samples that were exposed to tungsten transport experiments for nuclear fusion research. In addition, these methods may be applied to provide individual areal density measurements for the five unique isotopes of tungsten. It is found that areal density measurements via LA-ICP-MS agree with characterization for the same samples when using the more traditional Rutherford backscattering ion beam technique. Qualification of these reference materials was completed using ion beam laboratories at the University of Tennessee, Knoxville and Massachusetts Institute of Technology, and Sandia National Laboratory.

36 MATERIALS SCIENCE↗

Enhancing Neutrino Event Simulation through Overlays at the ICARUS Experiment on the Short-Baseline Neutrino Program

In the pursuit of precise neutrino event simulation, the ICARUS experiment within the Short-Baseline Neutrino (SBN) program at Fermilab uses an overlay technique to closely align simulations with experimental data. This technique consists of taking signals from data from each of the each of the three subsystems (TPC, PMT, CRT) and overlaying a simulated neutrino interaction onto the event. The overlay procedure includes superimposing simulated waveforms from neutrino interactions from both Time Projection Chambers (TPC) and Photomultiplier Tubes (PMTs) onto their respective data counterparts. Furthermore, the Cosmic Ray Tagger (CRT) hits from both data and simulations are combined to form the overlay event. By combining signals in this manner, we can obtain a data-driven modeling of cosmic backgrounds as well as the detector response enabling a more precise handling of noise sources when using neutrino simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal Transport for e/$\pi^0$ Particle Classification in LArTPC Neutrino Experiments

Separation of electron signals from $\pi^0$ backgrounds is crucial for neutrino oscillation measurements and searches for Beyond Standard Model (BSM) physics in current and future Liquid Argon Time Projection Chamber (LArTPC) experiments. e/$\pi^0$ separation has been a reconstruction challenge since both e and $\pi^0$ present as electromagnetic showers, and often only one out of the two showers produced by $\pi^0$ is reconstructed correctly. This research aims to improve the performance of e/$\pi^0$ separation using optimal transport (OT), by leveraging on the topological differences in the showers produced by the two particles. OT is a method which compares two distributions by finding the most efficient way to transform, or “move” from one to the other. This work uses the MicroBooNE open samples public dataset to test the e/$\pi^0$ separation performance of the method on events which incorporate realistic modeling of LArTPC detector response. Reconstructed 3D energy deposits are projected onto a plane perpendicular to the primary shower, allowing OT to better detect the topological differences between the two types of particles without the need to separately reconstruct all the showers in the events. Different distance metrics for OT are tested and preliminary results on e/$\pi^0$ separation are presented.

43 PARTICLE ACCELERATORS↗

Metrics and Methods for Radiation Detection Algorithm Characterization for Nuclear/Radiological Source Search

This report presents a series of recommendations for data to train and evaluate radiation detection algorithms and performance metrics to evaluate these algorithms. These recommendations were formed through a community consensus approach through the Detection Radiation Algorithms Group (DRAG), a multi-institution collaboration spanning eight Department of Energy laboratories and John Hopkins Applied Physics Laboratory. This report includes recommendations on background data variability, and metrics to quantify variability, sources and shielding configurations to include in data collection campaigns and detector response variability. In addition, this report describes several anomaly detection and identification algorithms and recommends metrics to report their performance. Finally, this report ends with a discussion on machine learning algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Xenon Sensor Analysis Report

Radiotracer release experiments were performed at the Nevada National Security Site in October 2022. The overall experiment was called the RElease ACTivity (REACT) experiment. Twenty-two real-time xenon sensors were deployed for each of four releases. Initial, quick-look analysis results were reported in December 2022. This report reviews the more comprehensive offline analysis effort that was conducted during the remainder of fiscal year 2023 by the Dynamic Networks venture. Improved energy stabilization routines were implemented along with an improved background subtraction routine compared to the original quicklook calculations. The relative detection efficiencies of all real-time sensors were examined. Finally, simulated detector response functions were coupled to two different meteorological models using the measured conditions for the final release (REACT-04) to compare simulated detections with measurements. While there is some agreement between the models and measured data on the detection locations and timing, there is less agreement on the magnitude of those detections. Future sensor and meteorological modeling work will be needed to improve the agreement and to examine the additional releases (REACT-01 through REACT-03).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Gamma Simulations of TRISO Fuel Elements

As energy demand rises, nuclear energy, particularly from reactors that use tristructural isotropic (TRISO) fuels, has gained attention due to the fuel’s enhanced resistance to radiation damage and high temperatures. This report investigates the modeling capabilities of the Gamma Detector Response and Analysis Software (GADRAS) for TRISO fuels, focusing on the gamma signatures of TRISO particles, which have not been extensively explored. Using the Monte Carlo N-Particle (MCNP) code as a benchmark, we developed both homogeneous and heterogeneous models of TRISO pebbles to analyze gamma spectra. Our findings reveal that the homogeneous and heterogeneous models produced different gamma signatures. Additionally, the GADRAS heterogeneous model significantly reduces computation times compared to MCNP, enabling effective modeling of gamma signatures for safeguards applications. This advancement is essential for the International Atomic Energy Agency (IAEA) in detecting anomalies and potential smuggling attempts in TRISO reactor fuel elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Special Nuclear Geometric Modeling

This report is a summary of our summer interns project that focused on investigating the usefulness of the Gamma Detector Response and Analysis Software (GADRAS) into the Material Control & Accountability (MC&A) Measurements Team. The project's findings highlight the advantages of using GADRAS and demonstrate its value in improving the MC&A Measurements Team's analytical capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refining a Novel Process Monitoring Method to Safeguard Continuously Cycling Designs Using Isotopic Ratios

In advanced reactor (AR) designs, a common feature is continuous chemical processing and circulation of the nuclear material. This work bridges a significant measurement gap in safeguarding reactors with circulating fuel or continuous refueling by leveraging and building on the isotope ratio method first developed by our team under an FY21 Advanced Reactors International Safeguards Engagement (ARISE) project (Uribe et al. 2021). In circulating fuel designs, the radioisotope inventory changes from traditional effects (e.g., radioactive decay, fission) but also includes material transport due to pressure and temperature gradients. Such designs may also require regular or continuous additions or removals during operation, which significantly increases the rate of inventory change compared to traditional pressurized water reactor (PWR)s. Thus, directly tracking the nuclear inventory is ineffective since the isotopes are continuously added and removed. The isotope ratio method instead focuses on detecting changes to the input and output flows of radioisotopes. Previous work showed that for well-chosen pairs of isotopes, the isotopic ratio provides a sensitive and lasting indicator of deviation from normal conditions (e.g., startup, shutdown, diversion). The isotope ratio method is a process monitoring method with potential for application in for forward-looking approaches to International Atomic Energy Agency (IAEA) safeguards. The original process monitoring method was developed for a specific case—the decay tank of a thorium-fueled molten salt breeder reactor. In this expanded work, we explored other types of reactors and processes with nonstationary (e.g., flowing) nuclear material, which are difficult to safeguard with traditional methods because of the transient nature of the systems. The goal of the present work is to generalize the isotope ratio method for use in processes with continuously flowing nuclear material. All continuous processes have an average time for isotopes to be replaced in the system. The isotope ratio method works by choosing radioisotopes with half-lives both above and below the processing time. The present work seeks to explore which isotopes are suitable for the method by simulating the nuclear inventory, radioisotope emissions, and detector responses for several classes of advanced reactors. While the method can in principle be applied to other processes (e.g., enrichment or reprocessing facilities), the present work limits scope to ARs with continuously flowing fuel. Section 2 details the mathematics supporting the isotope ratio method, and Section 3 introduces the representative ARs selected for this work. Section 4 discusses how each reactor was analyzed, and Section 5 showcases the results for each representative reactor. Finally, Section 6 provides concluding remarks and suggests pathways for further analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗