Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Melting and density of MgSiO 3 determined by shock compression of bridgmanite to 1254GPa

The essential data for interior and thermal evolution models of the Earth and super-Earths are the density and melting of mantle silicate under extreme conditions. Here, we report an unprecedently high melting temperature of MgSiO 3 at 500 GPa by direct shockwave loading of pre-synthesized dense MgSiO3 (bridgmanite) using the Z Pulsed Power Facility. We also present the first high-precision density data of crystalline MgSiO 3 to 422 GPa and 7200 K and of silicate melt to 1254 GPa. The experimental density measurements support our density functional theory based molecular dynamics calculations, providing benchmarks for theoretical calculations under extreme conditions. The excellent agreement between experiment and theory provides a reliable reference density profile for super-Earth mantles. Furthermore, the observed upper bound of melting temperature, 9430 K at 500 GPa, provides a critical constraint on the accretion energy required to melt the mantle and the prospect of driving a dynamo in massive rocky planets.

58 GEOSCIENCES↗

HPC4Mfg with Sepion

A computational framework was developed for predictive determination of polymer membrane porosity based solely on proposed polymer chemistry employing a multi-scale theoretical approach. The resulting polymer structures matched measured density and porosity measurements and established a protocol for future predictions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for gamma rays of energy 10(15) eV from Cygnus X-3

Finite flux of excess radiation of energy 10 to the 15th power has been reported by two groups from the direction of Cygnus X-3, with the characteristic periodicity of 4.8 hrs. Samorski and Stamm find that the muon content of the showers generated by this excess radiation is about 77% of that in normal cosmic ray showers, whereas the expectation for gamma ray showers is less than 10%. It is thus difficult to understand the nature of the radiation arriving from the direction of Cygnus X-3. Samorski and Stamm measured the muon densities close to the core (approx. 10 m), where contamination due to other components is severe. Even though this does not explain the high ratio of muon densities, measurements should be carried out away from the core to establish the nature of the radiation. In order to establish the signal from Cygnus X-3 and its muon content with better statistical significance, an extensive air shower array, specifically designed for this purpose was operated at Kolar Gold Fields (longitude: 78 deg .3 E; latitude: + 12 deg .95; atmospheric depth: 920 q/square centimeters) since September, 1984. The details of the array and the accuracy of arrival direction measurements are discussed.

Bhat, P. N.↗

Solar wind iron charge states preceding a driver plasma

Iron and silicon/sulfur charge state and velocity measurements and iron density measurements in the shocked solar wind which preceded the flare-related driver plasma observed on September 29, 1978 by ISEE 3 are reported. Given the assumption that the driver plasma is magnetically isolated from the ambient solar wind, the contact surface separating these two plasma regimes is expected to form an distinct boundary in the charge state composition. Instead, an apparent transition in the ionization state of the shocked solar wind from ambient solar wind values to those typical of the driver plasma is observed. This result may reflect X-ray ionization of the solar wind plasma near the flare site.

Galvin, A. B.↗

Vapor Growth and Characterization of ZnSeTe Solid Solutions

Six ZnSe(1-x)Te(x) crystals were grown by the physical vapor transport technique. For each of the source material compositions, x = 0.10, 0.20 and 0.30, two crystals were grown - one under the horizontal and the other under the vertical stabilized configurations. The axial and radial compositional uniformity were measured by precision density measurements, wavelength dispersive X-ray spectroscopy (WDS) and optical transmission mappings. The measured radial ZnTe content was quite uniform for all the grown crystals except the horizontally grown crystal for x = 0.30. The WDS results on this crystal indicated a core with uniform ZnTe content, about 0.38, surrounded by a thin region of high ZnTe content with x = 0.8. This feature was confirmed by the SEM back scattering electron images. For the three source compositions the axial compositional variations for the vertically grown crystals were more uniform than that for the horizontally grown crystals. The measured compositions in the crystals grown from source composition of x = 0.10 suggest that the transport mechanism in the system can not be interpreted by a simple one-dimensional diffusion limited model.

Su, Ching-Hua↗

Stability of Detached Grown Germanium Single Crystals

Detachment of the melt meniscus from the crucible during semiconductor Bridgman growth experiments has been observed in recent years, especially under microgravity experiments. Under earth conditions, the hydrostatic pressure counteracts the mechanism, whereby it is more difficult to achieve detached Bridgman growth. Attempts to get stable detached growth under terrestrial conditions have been discussed in the literature and have been the subject of recent experiments in our own group. The advantage of crystals grown without wall contact is obvious: In general, they possess a higher crystal quality than conventional Bridgman grown crystals with wall contact. However, due to the interaction of different parameters such as the wetting behavior of the melt with the crucible, and the dependence of the growth angle with the shape of the melt meniscus, the mechanism leading to detachment is very complicated and not completely understood. We have grown several doped and undoped Germanium crystals with the detached Bridgman and the normal Bridgman growth technique. Pyrolytic boron nitride containers were used for all growth experiments. In the detached grown crystals the typical gap thickness between the pBN crucible and the crystal is in the range of 10 to 100 micrometers, which was determined by performing profilometer measurements. Etch pit density measurements were also performed and a comparison between detached and attached grown crystals will be given. An interesting feature was detected on the surface of a detached grown crystal. Strong surface striations with an average axial distance of 0.5 mm were observed around the whole circumference. The maximum fluctuation of the gap thickness is in the range of 5-10 micrometers. These variations of the detached gap along the crystal axis can be explained by a kind of stiction of the melt/crucible interface and thus by a variation of the meniscus shape. This phenomenon leading to the fluctuation of the gap thickness will be discussed in detail.

Schweizer, M.↗

Stability of Detached Grown Germanium Single Crystals

Detachment of the melt meniscus from the crucible during semiconductor Bridgman growth experiments has been observed in recent years especially, under microgravity experiments. Under earth conditions, the hydrostatic pressure counteracts the mechanism, whereby it is more difficult to achieve detached Bridgman growth. Attempts to get stable detached growth under terrestrial conditions have been discussed in the literature and have been the subject of recent experiments in our own group. The advantage of crystals grown without wall contact is obvious: In general, they possess a higher crystal quality than conventional Bridgman grown crystals with wall contact. However, due to the interaction of different parameters such as the wetting behavior of the melt with the crucible, and the dependence of the growth angle with the shape of the melt meniscus, the mechanism leading to detachment is very complicated and not completely understood. We have grown several doped and undoped Germanium crystals with the detached Bridgman and the normal Bridgman growth technique. Pyrolytic boron nitride containers were used for all growth experiments. In the detached grown crystals the typical gap thickness between the pBN crucible and the crystal is in the range of 10 to 100 microns, which was determined by performing profilometer measurements. Etch pit density measurements were also performed and a comparison between detached and attached grown crystals will be given. An interesting feature was detected on the surface of a detached grown crystal. Strong surface striations with an average axial distance of 0.5mm were observed around the whole circumference. The maximum fluctuation of the gap thickness is in the range of 5-10 microns. These variations of the detached gap along the crystal axis can be explained by a kind of stiction of the melt/crucible interface and thus by a variation of the meniscus shape. This phenomenon leading to the fluctuation of the gap thickness will be discussed in detail.

Schweizer, M.↗

X-Ray Computed Tomography Inspection of the Stardust Heat Shield

The "Stardust" heat shield, composed of a PICA (Phenolic Impregnated Carbon Ablator) Thermal Protection System (TPS), bonded to a composite aeroshell, contains important features which chronicle its time in space as well as re-entry. To guide the further study of the Stardust heat shield, NASA reviewed a number of techniques for inspection of the article. The goals of the inspection were: 1) to establish the material characteristics of the shield and shield components, 2) record the dimensions of shield components and assembly as compared with the pre-flight condition, 3) provide flight infonnation for validation and verification of the FIAT ablation code and PICA material property model and 4) through the evaluation of the shield material provide input to future missions which employ similar materials. Industrial X-Ray Computed Tomography (CT) is a 3D inspection technology which can provide infonnation on material integrity, material properties (density) and dimensional measurements of the heat shield components. Computed tomographic volumetric inspections can generate a dimensionally correct, quantitatively accurate volume of the shield assembly. Because of the capabilities offered by X-ray CT, NASA chose to use this method to evaluate the Stardust heat shield. Personnel at NASA Johnson Space Center (JSC) and Lawrence Livermore National Labs (LLNL) recently performed a full scan of the Stardust heat shield using a newly installed X-ray CT system at JSC. This paper briefly discusses the technology used and then presents the following results: 1. CT scans derived dimensions and their comparisons with as-built dimensions anchored with data obtained from samples cut from the heat shield; 2. Measured density variation, char layer thickness, recession and bond line (the adhesive layer between the PICA and the aeroshell) integrity; 3. FIAT predicted recession, density and char layer profiles as well as bondline temperatures Finally suggestions are made as to future uses of this technology as a tool for non-destructively inspecting and verifying both pre and post flight heat shields.

McNamara, Karen M.↗

Lidar Measurements of Methane and Applications for Aircraft and Spacecraft

Atmospheric methane levels have remained relatively constant over the last decade around 1.78 parts per million (ppm) but observations since 2007 show that levels may be increasing. This trend may be caused by increased fossil fuel production, rice farming, livestock and landfills, but the underlying causes are quite uncertain. One hypothesis is that reservoirs of carbon trapped in the permafrost regions of northern Canada, Europe, and Siberia thaw as global temperatures rise and are releasing increasing amounts of methane. Another hypothesis points to increased production of methane by microbes as the permafrost warms. Currently most observations of greenhouse gases are limited to in-situ (surface and tower sites) and limited airborne in-situ measurements. Space column density measurements are starting to become available from the GOSAT mission. Although methane survives for a shorter time in the atmosphere than CO2, its impact on climate change per molecule is about 23 times than that of CO2. Accurate global observations of several greenhouse gases, including methane, are urgently needed in order to better understand climate change processes and to reduce the uncertainty in the carbon budget. Differential absorption lidar is a well-established technique to measure atmospheric gases, and methane has optical absorption bands near 1.65,2.2,3.4 and 7.8 micron. The near infrared overtones lines of CH4 near 1650 nm are relatively free of interference from other species. There are absorption lines near 1651 nm which are both temperature insensitive and have line strengths well suited for lidar measurements. We have developed a laser and demonstrated lidar measurements of CH4 using lines in this band. Our laser uses a narrow linewidth 1064 nm laser pulse passing through a nonlinear crystal. We generate the tunable laser signals near 1651 nm by using the optical parametric amplification (OPA) process. Inside the crystal the 1064 nm beam overlaps with an injection seed laser near 1651 nm from a wavelength tunable diode laser. Incident photons from the pump laser pulse are converted into two photons, with one at the wavelength of the injection seeder. The wavelength of the OPA output is tuned via the wavelength of diode laser. Our laser is tunable, operates near 1651 nm and generates approximately 4 uJ/pulse at 6 KHz. We vary the emission wavelengths within this band by tuning the diode laser's wavelength. We have used this OPA transmitter to make measurements of CH4 at various pressures in a gas cell and over open outdoor horizontal paths. We have measured the lineshape of methane in a 6 cm long cell at various energy levels with this transmitter, with excellent agreement with the lineshape calculated by HITRAN. We have also measured the absorption lineshape of atmospheric methane in an open 3 km outdoor path. The agreement between the measurements and HITRAN, for 1746 ppb and 760 Torr was quite good. We have also made pulsed two wavelength lidar measurements of methane line absorption in the column to a tower at 1.5 km range. These used on- and off-line wavelengths of 1650.957 nm, and 1651.072 nm, and a 20 cm diameter receiver telescope with an infrared PMT detector. The absorption of the on-line photons was 30%. The methane column absorption was estimated via HITRAN, and was in good agreement with the expected methane absorption for a concentration of 1750 ppm. Finally we have calculated the measurement performance of an airborne methane lidar using this transmitter, as well as the energy and telescope scaling needed for a lidar for space. These results, and more details of our experiments will be described in the presentation.

Riris, Haris↗

Lunar Surface Material - Spacecraft Measurements of Density and Strength

The relation of the density of the lunar surface layer to depth is probably best determined from spacecraft measurements of the bearing capacity as a function of depth. A comparison of these values with laboratory measurements of the bearing capacity of low-cohesion particulate materials as a function of the percentage of solid indicates that the bulk density at the lunar surface is about 1.1 grams per cubic centimeter and that it increases nearly linearly to about 1.6 grams per cubic centimeter at a depth of 5 centimeters.

Jaffe, L. D.↗

XeF lidar measurements of density and temperature in the middle atmosphere

In recent years, it has been widely recognized that vertically propagating internal gravity waves in the middle atmosphere play an important role in determining the large scale wind field by their momentum transport and deposition. However, very little is known about them in the upper stratosphere and lower mesosphere because of the lack of adequate techinques to observe small scale motions. A XeF excimer laser was used for the Rayleigh lidar observation. The characteristics of the XeF lidar system are given. The wavelength of the XeF laser is in the region that is ozone absorption free, and the Rayleigh scattering cross section is 5 times larger than in 532 nm. The advantages of using the XeF laser as against the YAG laser have been discussed in detail. The density and temperature profiles between the altitude range of 30 and 70 km measured with this lidar system are illustrated. The accuracy is less than + or - 3% and 10k at 60 km for an observation time of 15 min. The results on the gravity waves by the observation through about one year since Apr. 1985 is presented.

Shibata, T.↗

Development and Construction of an Interferometer for Optical Measurements of Density Fields

A method of interference is described in the present report which promises profitable application in aeronautical research. The physical foundation of the method and a simple method of adjustment are briefly discussed. The special technical construction of the instrument is described which guarantees its use also in the case of vibrations of the surrounding space and permits the investigation of unsteady phenomena. It is found that the interference method will make the small differences in density in the flow field around the body even at low speeds. (40 m/sec) optically measurable.

Zobel, Th.↗

Comparison of laser-produced plasma spatio-temporal electron density evolution measured using interferometry with simulation results

Due to the difficulties associated with experimental measurements of laser-produced plasma (LPP) properties during the earliest stages of plasma evolution, radiation hydrodynamic codes are often used. However, although these codes have been extensively validated in the higher intensity regimes, validation at low to moderate intensities has been limited. In this study, the spatio-temporal electron density evolution in an LPP generated at moderate laser intensities and at various laser wavelengths was validated against the FLASH code for times up to 20 ns. The LPP was generated by focusing the fundamental and various harmonics radiation (1064, 532, and 266 nm) from a 6 ns full width half maximum Nd:YAG laser, at a laser intensity of 10 GW cm -2 , onto a copper target. The spatio-temporal density evolution of the expanding plasma was analyzed using Nomarski interferometry. Experimental measurements were found to be consistent with FLASH simulations, and the dependence of electron densities on wavelength was found to be in agreement with analytical models, varying as n e ∝ λ -0.7 . However, slight differences were noted in the widths and shape functions of the experimental and simulated electron density profiles.

2D fast imaging↗

Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX

A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. Furthermore, to study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗