Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Rock Valley Direct Earthquake-Explosion Comparison Experiment (RV-DC): Initial Feasibility Study

The RV-­DC is designed to be the capstone of the ongoing Source Physics Experiments. This report describes the motivation behind the RV-­DC and the tremendous potential scientific payoff for both nuclear explosion monitoring and earthquake source physics expected from the RV-­DC experiment. The report describes the issues, work to date and plans for FY13 in the areas of defining the shot location, depth and size, as well as addressing potential concerns about induced seismicity. We believe the RV-­DC is feasible. There do not appear to be any significant technical or scientific issues that would prevent the RV-DC from being carried out in the approximately FY14‐16 timeframe. This timeframe allows sufficient time for work to continue in FY13 to better define the experimental plan. It is our recommendation, based on the work to date and the potential payoff of the RV-­DC experiment, that the currently defined work for FY13 to better define the experimental plan, proceed.

58 GEOSCIENCES↗

Intelligent, grid-friendly, modular extreme fast charging system with solid-state DC protection

The development of electric vehicle (EV) charging infrastructure is crucial for the widespread adoption of electric transportation. However, implementing such infrastructure is a complex task that requires consideration of factors such as space limitations, adherence to industry standards, grid capacity, and other technical and policy issues. This project seeks to create a framework for the efficient design of compact medium voltage (MV) extreme fast charging (XFC) stations for EVs. The station design involves the use of a solid-state transformer (SST) that connects to the MV distribution network, delivering power to a shared DC bus. This innovative approach eliminates the need for a step-down transformer to provide low-voltage service by connecting directly to the MV distribution network. Eliminating the low-frequency transformer not only reduces the system footprint and losses but also eliminates inrush currents during grid black-start. Additionally, placing power electronics directly on the distribution system allows for high-bandwidth filtering and power factor correction. The inclusion of a shared DC bus enables multiple charging dispensers and DC storage/generation units to connect, forming a DC microgrid. This setup facilitates power sharing with minimal conversion stages. The project showcases a DC distribution network protected by intelligent solid-state (SS) DC circuit breakers (DCCB) capable of isolating the smallest section of the faulted circuit much faster than existing mechanical solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of 22.4-kW nonlaminated-frame dc series motor with chopper controller

Performance data obtained through experimental testing of a 22.4 kW traction motor using two types of excitation are presented. Ripple free dc from a motor-generator set for baseline data and pulse width modulated dc as supplied by a battery pack and chopper controller were used for excitation. For the same average values of input voltage and current, the motor power output was independent of the type of excitation. However, at the same speeds, the motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points lower on chopped dc than on ripple free dc. The chopped dc locked-rotor torque was approximately 1 to 3 percent greater than the ripple free dc torque for the same average current.

Schwab, J. R.↗

Mathematical model for the dc-ac inverter for the Space Shuttle

The reader is informed of what was done for the mathematical modeling of the dc-ac inverter for the Space Shuttle. The mathematical modeling of the dc-ac inverter is an essential element in the modeling of the electrical power distribution system of the Space Shuttle. The electrical power distribution system which is present on the Space Shuttle is made up to 3 strings each having a fuel cell which provides dc to those systems which require dc, and the inverters which convert the dc to ac for those elements which require ac. The inverters are units which are 2 wire structures for the main dc inputs and 2 wire structures for the ac output. When 3 are connected together a 4 wire wye connection results on the ac side. The method of modeling is performed by using a Least Squares curve fitting method. A computer program is presented for implementation of the model along with graphs and tables to demonstrate the accuracy of the model.

Berry, Frederick C.↗

The Series Connected Buck Boost Regulator Concept for High Efficiency Light Weight DC Voltage Regulation

Improvements in the efficiency and size of DC-DC converters have resulted from advances in components, primarily semiconductors, and improved topologies. One topology, which has shown very high potential in limited applications, is the Series Connected Boost Unit (SCBU), wherein a small DC-DC converter output is connected in series with the input bus to provide an output voltage equal to or greater than the input voltage. Since the DC-DC converter switches only a fraction of the power throughput, the overall system efficiency is very high. But this technique is limited to applications where the output is always greater than the input. The Series Connected Buck Boost Regulator (SCBBR) concept extends partial power processing technique used in the SCBU to operation when the desired output voltage is higher or lower than the input voltage, and the implementation described can even operate as a conventional buck converter to operate at very low output to input voltage ratios. This paper describes the operation and performance of an SCBBR configured as a bus voltage regulator providing 50 percent voltage regulation range, bus switching, and overload limiting, operating above 98 percent efficiency. The technique does not provide input-output isolation.

Birchenough, Arthur G.↗

Effect of DC Offset on the T-Wave Residuum Parameter

The T-wave residuum (TWR) is a relatively new 12-lead ECG parameter that may reflect cardiac repolarization heterogeneity. TWR shows clinical promise and may become an important diagnostic tool if accurate, consistent, and convenient methods for its calculation can be developed. However, there are discrepancies between the methods that various investigators have used to calculate TWR, as well as some questions about basic methodology and assumptions that require resolution. The presence of a DC offset or very low frequency AC component to the ECG is often observed. Many researchers have attempted to compensate for these by high pass filters and by median beat techniques. These techniques may help minimize the contribution of a low frequency AC component to the TWR, but they will not eliminate a DC offset inherent within the instrumentation. The present study examined the presence of DC offsets in the ECG record, and their effect on TWR. Specifically, in healthy individuals, a DC offset was added to all 8 channels collectively or to each channel selectively. Even with offsets that were relatively small compared to T-wave amplitude, the addition of either collectively or individually applied offsets was observed to produce very significant changes in the TWR, affecting its value by as much as an order of magnitude. These DC offsets may arise from at least two possible sources: a transient artifact from EMG or electrode movement resulting in a transient baseline offset in one or more channels. Since highpass filters have a settling time of several seconds, these artifacts will contribute to a transitory baseline offset lasting 1020 cycles. The machine hardware may also introduce an offset. Regardless of the cause or source of a DC offset, this study demonstrates that offsets have a very significant impact on TWR, and that future studies must not ignore their presence, but rather more appropriately compensate for them.

Scott, N.↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Adaptive Threshold-Based Zonal Isolation of Faults in a Multiterminal DC Using Local Measurements

Fast and accurate methods of fault detection and isolation are a pre-emptive measure in multiterminal dc (MTdc) systems. Zonal isolation of faults is necessary to prevent any misopertation of the dc breakers that can lead to a shutdown of the network. Existing techniques require fast-communication or data synchronization methods have their own disadvantages. This article proposes a method for efficient fault zone isolation without the need of a communication link that prevents any misoperation of the dc breakers in a radial MTdc. This method provides individual local measurement-based control to the hybrid dc circuit breakers (dcCB). Faults created outside the zone of protection for a breaker create a change in the rate of change of current or voltage leading to misoperation. To avoid detection using a fixed threshold, an adaptive threshold based approach is suggested that updates the threshold based on the present operating status. Sensitivity analysis by varying the current limiting inductance and fault location is performed. In conclusion, a three terminal radial model of an MTdc is used for zonal isolation using power system computer aided design/electromagnetic transients including dc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Instrumentation for Assessing DC Electrical Distribution Systems in Buildings

Direct current (DC) distribution systems is emerging as a favorable option over alternating current in buildings due to its energy and non-energy benefits (e.g., efficiency, resilience, safety). However, limited guidelines exist to evaluate the DC electrical distribution infrastructure. This paper aims to fill that gap by detailing our experience with metering a building-level electrical DC distribution system. Our case study is a DC microgrid at the Direct Energy Partners Research & Development facility located in Charlotte, North Carolina. This paper presents our approach, technical challenges, and lessons learned with DC metering and instrumentation.

buildings↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

An Attempt to Shorten Loading Time of Epirubicin into DC Beads{sup ®} Using Vibration and a Sieve

PurposeWe investigated the possibility of shortening the time required for loading epirubicin into calibrated polyvinyl alcohol-based hydrogel beads (DC Beads{sup ®}) to be used for transarterial chemoembolization.MethodAfter separating the beads suspended in phosphate-buffered saline (PBS) solution by the use of a sieve (clearance 75 µm), epirubicin hydrochloride (EH) was loaded for 20, 30, or 60 s under vibration into DC beads. The EH loading rate into conventionally prepared (control) beads, i.e., beads loaded for 30 min without vibration, and vibration-loaded beads were calculated from the residual EH concentration in the bead-depleted EH solution. The amount of EH eluted from conventionally and vibration-loaded samples into a PBS solution (pH 7.0) was measured at 15 and 30 min and 1, 2, 6, 12, and 24 h. We also recorded the inhibitory effect of the PBS solution on the loading time. Using frozen sections, the EH load in the beads was evaluated visually under a fluorescence microscope.ResultsSpectrophotometry (495 nm) showed that the loading rate was 98.98 ± 0.34, 99.02 ± 0.32, and 99.50 ± 0.11 % with 20-, 30-, and 60-s vibration, respectively. The eluted rate was statistically similar between vibration- and statically loaded (control) beads. The PBS solution hampered EH loading into the beads. Visually, the distribution of EH in conventionally and vibration-loaded DC beads was similar.DiscussionThe use of vibration and the removal of PBS solution when epirubicin hydrochloride was loaded into DC beads dramatically shortened the loading time of epirubicin hydrochloride into DC beads.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research on the Corrosion Behavior of X70 Pipeline Steel Under Coupling Effect of AC + DC and Stress

The coupling effect of stray AC (alternating current) + DC (direct current) and tensile stress-induced X70 pipeline corrosion is complicated with its mechanism uncovered. In this work, the corrosion behavior of X70 pipeline steel under three different corrosion (including an individual AC corrosion, mixed AC + 150 MPa tensile stress corrosion, coupling effect of AC + a 30 A/m{sup 2} DC interference and 150 MPa tensile stress corrosion) conditions in Dagang soil simulated solution was investigated by COMSOL Multiphysics software simulation, electrochemical tests, scanning electron microscope and other techniques. The results indicated that with the increase in AC density, the open-circuit potential of the X70 steel samples was negatively shifted and corrosion rate increased in three different corrosion conditions. The corrosion rates of X70 steel samples under individual AC interference were almost unchanged when 150.9 MPa tensile stress was applied. When applying 30 A/m{sup 2} DC interference, the corrosion rate of X70 steel increases significantly. Therefore, the factors affecting corrosion performance of X70 pipeline steel were DC > AC > stress. Under individual AC interference, uniform corrosion occurred on the X70 steel at an AC current density of less than 30 A/m{sup 2}, while the pitting corrosion occurred at an AC current density of greater than 100 A/m{sup 2}. The application of tensile stress and DC had a certain inhibitory effect on pitting corrosion.

36 MATERIALS SCIENCE↗

Inorganic phosphate-induced impairment of osteoclast cell-cell fusion by the inhibition of AP-1-mediated DC-STAMP expression

Chronic kidney disease (CKD) causes hyperphosphatemia and secondary hyperparathyroidism, leading to several disorders of bone metabolism. Although high concentrations of extracellular inorganic phosphate (Pi) inhibit osteoclastogenesis, the molecular mechanism of this effect has not been fully understood. In the present study, therefore, we examined the effect of Pi on the differentiation of the osteoclast precursor RAW-D cells. Treatment with the receptor activator of nuclear factor-kappa B ligand induced the differentiation of RAW-D cells (osteoclastogenesis). However, Pi significantly weakened this effect, assessed by the tartrate-resistant acid phosphatase (TRAP) activity and the number of TRAP-positive multinucleated cells. Pi also reduced the expressions of nuclear factor of activated T-cell (NFAT) c1 and dendritic cell-specific transmembrane protein (DC-STAMP). Interestingly, the Pi-induced reduction of DC-STAMP gene promoter activity was lost when the activator protein 1 (AP-1) binding site was mutated. Since Pi strongly inhibited the expression of c-Fos which is the component of AP-1, the Pi-induced reduction of DC-STAMP expression was proposed to be mediated by the absence of c-Fos. These results suggested that hyperphosphatemia in the patients with CKD suppresses bone resorption by inhibiting osteoclastogenesis, and this impairs the regulation of bone metabolism. - Highlights: • Pi inhibits osteoclast differentiation through the reduction of NFATc1 and DC-STAMP expressions in RAW-D cells. • Inhibition of c-Fos expression could be involved in the reduction of DC-STAMP gene promoter activity. • Hyperphosphatemia in the patients with CKD could suppress bone resorption by inhibiting osteoclastogenesis, and this impairs the regulation of bone metabolism.

60 APPLIED LIFE SCIENCES↗

Trapped-ion cell with improved DC potential harmonicity for FT-ICR MS

The trapped-ion cell is a key component critical for optimal performance in Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). We have upgraded our 12 Tesla FT-ICR instrument with a new open cylindrical cell that includes four additional cylindrical segments that serve as compensation electrodes. The DC potential on the additional segments can be set to specific pre-calculated values to suppress DC trapping field anharmonicity, in an effort to improve coherence of the ion cyclotron motion and minimize deviations from the calibration function of the ideal cell. Alternatively, the compensation potentials can be set equal to potentials of adjacent cell electrodes, which creates a DC potential distribution equivalent to that of a regular open cylindrical cell. The initial experimental characterization of both the compensated and open cell configurations was performed using ESI direct infusion of a peptide mixture. Operating the compensated cell at increased post-excitation radii resulted in improved mass measurement accuracy together with increased signal intensity, while the regular configuration exhibited peak splitting and reduced signal life time under these operating conditions. The observed improvement of the compensated cell performance was consistent with the expected behavior due to the improved DC potential harmonicity. These results confirm that the trapping DC potential harmonicity is significant for optimizing FT-ICR MS performance.

Tolmachev, Aleksey V.↗

Electro-analytical method for the quantities evaluation of the silicon solar cell by DC and AC characterization technique

Highlights: • Exact electro-analytical method for evaluation of silicon solar cells. • DC and AC characterization technique to determine the performance limiting parameters of solar cells. • EIS is used to get an insight into the solar cells and parameter optimization. - Abstract: Mono and Poly- crystalline silicon (Si) based solar cell has proven to be the most efficient and matured technology till date. The present work reports an exact electro-analytical method for the evaluation of different performance parameters in the current voltage response of the Si solar cell by DC and AC characterization technique. The extracted solar cell parameters from DC and AC techniques were compared with each other under the proper limiting conditions of low and high forward bias. The DC and AC characterization are used to determine the bias dependence of ideality factor and series resistance, respectively. The current-voltage (J-V) characteristics is combined with the impedance spectroscopy (IS) measurements to reveal the various interfacial, resistive and recombination analysis of the silicon solar cell. Herein the experimentally obtained J-V characteristics under the illumination condition have been reconstructed by individually extracted parameters from DC and AC measurements. Moreover, the present mechanistic provides a simple tool for analysing the commercial Si solar cell with a wide applicability for other solar cells.

14 SOLAR ENERGY↗

Shapiro steps and stability of skyrmions interacting with alternating anisotropy under the influence of ac and dc drives

Here we use atomistic simulations to examine the sliding dynamics of a skyrmion in a two-dimensional system containing a periodic one-dimensional stripe pattern of variations between low and high values of the perpendicular magnetic anisotropy. The skyrmion changes in size as it crosses the interface between two anisotropy regions. On applying combined dc and ac driving in either parallel or perpendicular directions, we observe a wide variety of Shapiro steps, Shapiro spikes, and phase-locking phenomena. The phase-locked orbits have two-dimensional dynamics due to the gyrotropic or Magnus dynamics of the skyrmions and are distinct from the phase-locked orbits found for strictly overdamped systems. Along a given Shapiro step when the ac drive is perpendicular to the dc drive, the velocity parallel to the ac drive is locked while the velocity in the perpendicular direction increases with increasing drive to form Shapiro spikes. At the transition between adjacent Shapiro steps, the parallel velocity jumps up to the next step value, and the perpendicular velocity drops. The skyrmion Hall angle shows a series of spikes as a function of increasing dc drive, where the jumps correspond to the transition between different phase-locked steps. At high drives, the Shapiro steps and Shapiro spikes are lost. When both the ac and dc drives are parallel to the stripe periodicity direction, Shapiro steps appear, while if the dc drive is parallel to the stripe periodicity direction and the ac drive is perpendicular to the stripe periodicity, then there are only two locked phases, and the skyrmion motion consists of a combination of sliding along the interfaces between the two anisotropy values and jumping across the interfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft Switching Over the Entire Line Cycle for a Quadruple Active Bridge DCX in a DC to Three-Phase AC Module

This paper is focused on a transformer-isolated quadruple active bridge (QAB) dc-dc converter loaded by three full-bridge dc-ac inverters. The QAB functions as a "DC trans-former" (DCX) in the dc-to-three-phase ac module. The QAB outputs provide time-varying power at twice the line frequency, which presents challenges in maintaining zero voltage switching (ZVS) on the secondary sides during low-power portions of the line cycle. It is shown how ZVS can be achieved in a phase, even at zero-power transfer, using a relatively small circulating current provided by the magnetizing inductance of the high-frequency transformer. The approach is particularly effective in high-voltage applications using SiC MOSFETs, where reductions in switching loss outweigh additional conduction losses due to the circulating currents. A detailed analysis of ZVS switching waveforms at the zero power transfer is presented, including effects of nonlinear device capacitances. Analytical expressions are given for the optimal values of the magnetizing inductance and dead times of the QAB primary and secondary bridges. The approach is verified by experimental results on a 600 V, 4 kW prototype, demonstrating greater than 98.5% efficiency from 1 kW to 4 kW, with a peak efficiency of 99.0%. Compared to conventionally operated prototype, a 54% reduction in total loss is achieved at rated power.

41 EE - Solar Energy Technologies Office (EE-4S)↗