An Advanced Cyber-Physical System Security Testbed for Substation Automation

A Cyber-Physical System (CPS) testbed serves as a powerful platform for testing and validating cyber intrusion detection and mitigation strategies in substations. This study presents the design and development of a CPS testbed that can effectively assess the real-time dynamics of a substation. Cyber attacks exploiting IEC 61850-based SV and GOOSE protocols are demonstrated using the testbed, along with an analysis on attack detection. Realistic timing measurements are obtained, and the time frames for deploying detection and mitigation strategies are evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Privacy-preserving Information Security for the Energy Grid of Things

Smart grid infrastructure relies on information exchange between multiple actors in order to ensure system reliability. These actors include but are not limited to smart loads, grid control, and energy management technologies. Further, as information exchange between these actors is susceptible to cyber-attacks, security and privacy issues are indispensable to ensure a reliable and stable grid. This position paper proposes a privacy-preserving, trust-augmented secure scheme for a smart grid implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

IS BLOCKCHAIN A SUITABLE TECHNOLOGY FOR ENSURING THE INTEGRITY OF DATA SHARED BY LIGHTING AND OTHER BUILDING SYSTEMS?

Increasing amounts of data are available from lighting and other building systems. In commercial buildings, these data can be used to improve system and energy performance, detect and diagnose faults, and facilitate maintenance. Building data are not only of interest to owners and operators of the building systems, however. Owners and operators of similar buildings, manufacturers of building systems, utilities, and city agencies also have interesting use cases. Energy data can, for example, be used to verify the performance of energy-conservation measures, issue renewableenergy certificates, and financially settle grid services. Increased data sharing, however, significantly expands the cyber-attack surface, creating new challenges. In this work, blockchain is explored as an option for ensuring the integrity of data that are shared by lighting and other building systems. Blockchain fundamentals and variants are briefly reviewed, and value propositions relevant to building systems are discussed. A recently developed blockchain applicability framework (BAF) that builds upon and addresses the limitations of previous applicability models is also briefly reviewed. The BAF is used to assess the suitability of blockchain over other technologies or approaches for building-data applications, using emerging connected lighting systems as an example use case.

blockchain, connected lighting system, data integr↗

Control-Theory-Informed Feature Selection for Detecting Malicious Tampering in Additive Layer Manufacturing Processes

Additive layer manufacturing (ALM) is rapidly becoming an appealing solution to the low-volume manufacturing of metal, polymer, or composite parts. However, ALM’s reliance on digital part specifications, microcontrollers, and modern networking makes these devices vulnerable to malicious tampering by cyber attackers, which can negatively affect part performance and even result in catastrophic failure. We present a hybrid analytic approach to feature discovery using control theoretic techniques and linear modelling on input-output data collected from a representative controller system. Employing this approach, we design, train, and test an anomaly detection system. The preliminary results show that the proposed approach effectively discovers useful input-output relationships for anomaly detection in a simulated ALM process. Application to larger and more complex systems are discussed.

Dawson, Joel↗

Guided Resilience Self Assessment Application

Reliable electricity access is vital for everything from hospitals to national security. When grid disturbances occur, it is crucial to minimize the amount of time it takes to recover. Grid resiliency considers both the preparation for and recovery from high-impact low-frequency disturbances (HILF) such as weather events and cyber attacks. The Department of Energy (DOE) Wind Energy Technologies Office (WETO) funds the multi-laboratory Microgrids, Infrastructure Resilience, and Advanced Control Launchpad (MIRACL) project to investigate technologies to support and grow distributed wind. Researchers at Idaho National Laboratory (INL) contribute to resilience and cybersecurity efforts for the project, and have produced a resilience framework to evaluate system resilience based on individual system specifications. In order to make this framework easy for anyone to apply, I have coded a web application that allows users to input their power system qualities, goals, and perceived risks and then receive suggestions on how to improve their grid resiliency. The web application follows the seven steps in the planning stage of the framework process, allowing the user to input information about their grid and select from common goals, metrics, and hazards, as well as add their own. The application currently provides information about how to complete each step, requiring minimal prior knowledge of the framework. Future work for this application will include allowing the user to submit line drawings of their system and incorporate modeling tools so that the hazard simulations of applying the framework is completed for the user.

97 MATHEMATICS AND COMPUTING↗

Protecting Smart Buildings with STIG

This is a submission for the 2022 Intern Poster Session. The abstract of the poster is: Smart buildings are getting more common, and so are hackers that target them. The physical systems in our businesses and homes are now vulnerable to cyber attacks. Using STIG, an INL program that turns cybersecurity data into graphs, buildings can be better protected.

99 GENERAL AND MISCELLANEOUS↗

OPERATIONAL TECHNOLOGY BEHAVIORAL ANALYTICS (OTBA) – A DATA-CENTRIC APPROACH FOR REDUCING CYBERSECURITY RISK

This paper provides a summary of the methodology, findings, lessons learned, and insights from an investigation into the feasibility of the Operational Technology Behavioral Analytics (OTBA) cybersecurity approach. The concept was evaluated with data from the National Carbon Capture Center (NCCC) – a U.S. Department of Energy (DOE) funded facility that is managed and operated by Southern Company at Alabama Power’s E. C. Gaston generating power plant in Wilsonville, Alabama. Appropriate data sources for the post-combustion carbon capture system were identified. Infrastructure was deployed to monitor, capture and archive data for the system. Critical parameters for each subsystem were identified and analyzed. Machine-learning algorithms were used to establish and characterize normal operations and subsequently identify anomalies. This effort yielded valuable insights and formed the basis of a data-centric strategy for detecting cyber-attacks along with a coordinated response philosophy. A significant takeaway is that the OTBA cybersecurity approach is quite portable; it can be applied to other critical infrastructure beyond fossil power generation.

Black, Clifton↗

Variable Resource Resilience: How Systems Experience Increased Resilience from Variable and Hybrid Resources

Variable resources like wind and solar are often seen as detriments to system resilience rather than benefits because they may not be available with the capacities or services required during a high-impact low-frequency (HILF) event, whether that is a physical threat, natural disaster, or cyber attack. However, resilience goals and metrics are inadequate for electric energy delivery systems with inverter-based resources. Examination of this topic reveals that renewable resources are well suited to combat many resilience hazards due to local resource availability. Metrics that demonstrate the resilience value of variable resources are presented and categorized for resource (wind, solar, storage, hybrid) and installation type (bulk utility scale, behind-the-meter, front-of-the-meter, isolated). Distributed and hybrid systems can further enhance resilience benefits my maximizing resource potential for a locality. A case study demonstrating quantitative resilience benefits from wind alone is provided for St. Mary's, AK, which concludes that hundreds of thousands of dollars are saved by the addition of a wind turbine in the face of realistic fuel shortage and extreme winter weather scenarios.

17 WIND ENERGY↗

All Hazards Approach to Grid Modernization

Resilience hazards for electric power systems are on the rise, exacerbated by both a rise in extreme weather events and manmade physical and cyber attacks. At the same time, grid modernization challenges plague the United States, covering everything from increased electrification and ambitious renewable energy targets to aging infrastructure and regulation that lags behind today’s challenges. This talk will cover an all-hazards risk based approach that addresses both rising resilience and grid modernization challenges. Examples of this approach taken for national laboratory research projects will be discussed, including a deep dive into a project that addressed black start, resynchronization, distributed control, and cybersecurity challenges for an operational microgrid up to sub-transmission voltages. As takeaways from this project are translated from demonstration scale to real-world exercises, key lessons are noted on the translation from research into practice and how this can inform risk-based research moving forward

17 WIND ENERGY↗

OT Operational Anomaly Detection (OAD) T&D + DER

The growth of utility-scale renewable energy resources, distributed energy resources (DER), and transportation electrification has increased uncertainty and cybersecurity risks in power grids. The Purdue Enterprise Reference Architecture model which is widely adopted by the utility industry is now insufficient to protect the power grid against cyber-attacks. There is a need to identify what cybersecurity model is effective on Energy Management System (EMS), Advanced Distribution Management System (ADMS), and DER Management System (DERMS) to address the fundamental cybersecurity challenges in the age of increasing renewable energy and DER share as well as consumer participation in the electric energy industry. The next generation of cybersecurity model for OT network should be able to detect inside attackers, mitigate the cybersecurity risks arising from the new grid participants including DER aggregators, electric vehicle owners, and behind-the-meter consumers outside the utility company, and develop the strategy to trust consumer measurement data. This panel will discuss the challenges and pathways for the development of an ensemble cybersecurity model based on predictive state estimation to detect cybersecurity anomalies in OT network including EMS, ADMS, and DERMS.

cybersecurity↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Robust and cybersecure coordinated unintentional island detection for microgrids

Unintentional islanding (UI) of a circuit of distributed energy resources (DERs) may leave area electrical power systems (EPS), external to the DER circuit, energized. Thus, UI detection methods have been developed to detect unintentional islanding and trigger a UI response. However, individual UI detection methods have various deficiencies. Thus, a consensus-based UI detection process is disclosed that builds a consensus from multiple UI detection sources, optionally implementing different UI detection methods. The redundancy in this consensus-based UI detection process provides robust, sensitive, selective, and cybersecure UI detection for the entire DER circuit. For example, the consensus-based UI detection process may eliminate or reduce non-detection zones, avoid false positives, thwart cyber-attacks, and/or the like.

Brissette, Alex↗

Software defined networking moving target defense honeypot

Disclosed herein are systems, methods, and storage media for thwarting cyber-attacks and data theft. A computing system receives packets and compares with a configuration resource. The computing system determines that the packet does not match the configuration resource and transmits a packet to a decoy environment via an SDN switch. The decoy environment is configured to generate time-out, service unavailable, or restricted access messages. In some embodiments, the computing system determines the packet does match the configuration and transmits the packet to a production network via an SDN switch. The SDN switch is communicatively connected to the decoy environment through a first channel and communicatively connected to a production environment through a separate second channel. The computing system is further configured to create and transmit to the SDN switch, rules to manage transmitting the packet to either the decoy environment or the production environment.

Lyle, Joshua A.↗

Internship Presentation: Integrating Safety and Cybersecurity: Security-by-Design with SOWT Analysis for Reactor Testing

This study covers leveraging reactor testing facilities that are primarily designed with a focus on safety to enhance cybersecurity testing. By incorporating reactor security-by-design with reactor safety-by-design principles and adopting defense-in-depth strategies that emphasize both safety and security, the research evaluates applicable cyber tools, models, and solutions. This includes simulating specific cyber-attack scenarios using reactor simulators and performing SWOT (Strengths, Weaknesses, Opportunities, Threats) analysis to improve the cybersecurity of reactor systems.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A Typing Discipline for High-Assurance Control Systems

This poster describes a typing discipline for high-assurance industrial systems based on three novel type systems. The first type system, information flow control (IFC), controls the flow of data through the system. The second system, dependent session types, restricts messages exchanged during the execution of a communication protocol to avoid dangerous states. The third system uses dimensional analysis to avoid subtle bugs that adversaries can exploit to cause the system to enter a dangerous state. This poster describes how a combination of these approaches can prevent sophisticated cyber attacks, such as the infamous Stuxnet incident, from occurring. In addition, we provide experimental evidence to support the claim that these approaches can be applied in control systems that are resource-constrained.

42 - ENGINEERING↗

Smart Inverters, Dumb Risk: Taking Control of IBR Security in the Digital Age

This presentation addresses the security challenges posed by Inverter-Based Resources (IBRs) in the modern energy landscape. The presentation highlights the vulnerabilities and risks associated with IBRs, including the potential for cyber-attacks, the impact of insecure defaults, and the systemic risks posed by supply chain dependencies. Key topics covered include: 1) The increasing digital transformation in energy systems and the associated security risks. 2) Specific vulnerabilities in IBRs, including weak passwords, hardcoded credentials, and insecure web application interfaces. 3) The implications of persistent connectivity and the strategic risks posed by foreign-manufactured components. 4) The role of regulatory frameworks, such as NERC CIP, in addressing these challenges and the limitations of current oversight. 5) Practical solutions for mitigating risks, including secure design practices, vendor risk assessments, and the importance of strong passwords and role-based access control. The presentation underscores the necessity of a comprehensive, system-of-systems approach to securing IBRs, emphasizing the need for collaboration across various stakeholders, including operators, developers, and regulators, to ensure the resilience and security of the energy grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Grid Cyber-Security Strategy in an Attacker-Defender Model

The progression of cyber-attacks on the cyber-physical system is analyzed by the Probabilistic, Learning Attacker, and Dynamic Defender (PLADD) model. Although our research does apply to all cyber-physical systems, we focus on power grid infrastructure. The PLADD model evaluates the effectiveness of moving target defense (MTD) techniques. We consider the power grid attack scenarios in the AND configurations and OR configurations. In addition, we consider, for the first time ever, power grid attack scenarios involving both AND configurations and OR configurations simultaneously. Cyber-security managers can use the strategy introduced in this manuscript to optimize their defense strategies. Specifically, our research provides insight into when to reset access controls (such as passwords, internet protocol addresses, and session keys), to minimize the probability of a successful attack. Our mathematical proof for the OR configuration of multiple PLADD games shows that it is best if all access controls are reset simultaneously. For the AND configuration, our mathematical proof shows that it is best (in terms of minimizing the attacker's average probability of success) that the resets are equally spaced apart. We introduce a novel concept called hierarchical parallel PLADD system to cover additional attack scenarios that require combinations of AND and OR configurations.

97 MATHEMATICS AND COMPUTING↗

Autonomous Tools for Attack Surface Reduction

The electric power grid is a complex critical infrastructure that forms the lifeline of modern society, and its secure and reliable operation is of paramount importance to national security and economic well being. However, recent findings documented in authoritative sources indicate the threat of cyber-based attacks growing in numbers and sophistication. However, securing the grid against stealthy cyber attacks is a challenging task due to legacy nature of the infrastructure coupled with dynamic nature of threat landscape and ever growing sophistication of the adversaries. Additionally, the grid’s attack surface continues to grow with the increased dependence on digital communications and control that now extends to each consumer through smart meters and distributed energy resources. Unfortunately, this expansive surface increases the grid’s vulnerability and further exposes critical control systems in both substations and control centers. To respond to this emerging need, we had successfully assembled an interdisciplinary team with academic- industry partnership to successfully conduct research, development, evaluation, demonstration, and commercialization of attack surface reduction tools, whose goal is to significantly reduce the cyber attack surface in the North American power grid. Our proposed project was a synergistic collaborative effort leveraging the synergistic expertise of the team members across power systems, cyber security and CPS security, testbeds, field deployments and demonstration, and successful commercialization. The team consisted of leading experts from two major universities – Iowa State University, Washington State University – complemented by reputed researchers from two DOE national laboratories – Pacific Northwest National Lab, and Argonne National Lab, one major utility vendor GE Global Research, and one utility partner – Cedar Falls Utilities (CFU). The team members have proven track record of successful academic-industry collaboration in interdisciplinary R&D projects, and bring onboard some of the best state-of-the-art testbed resources, industry-grade SCADA/EMS/DMS environment for experimentation and field demonstration.