Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “custom devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Printing noble metal alloy films with compositional gradient

Additive manufacturing has offered great promise in fabricating materials and devices with complex structures and unique properties. In addition to complex structures, additive manufacturing also allows for local changes to material compositions and/or structure, ideal for combinatorial material investigations. Besides, advantages over freedom of design, mass customization, waste minimization and the capability to fast prototyping, the on-demand control of compositional distributions in low dimensional materials remains challenging. In this work, we demonstrate a combinatorial aerosol jet printing technique to create noble metal films with gradient compositions. Nanoparticle sizes and ink chemistry are critical for aerosol jet printing and sintering process in order to achieve defect free thin films. Ruthenium (Ru) and platinum (Pt) nanoparticles with size <5 nm were synthesized and formulated into printable inks. Further, after thermal sintering at temperature as low as 400 °C, printed nanoparticles formed highly reflective films free from microstructural defect. Alloy films of gradient compositions were realized via in-situ mixing Ru and Pt ink streams and varying the mixing ratio during the printing process. This combinatorial printing method provides great potential to rapidly transform nanoparticle inks into new materials compositions and structures unobtainable via conventional methods for high-throughput materials studies.

36 MATERIALS SCIENCE↗

Development of 20 GHz monolithic transmit modules

The history of the development of a transmit module for the band 17.7 to 20.2 GHz is presented. The module was to monolithically combine, on one chip, five bits of phase shift, a buffer amplifier and a power amplifier to produce 200 mW to the antenna element. The approach taken was MESFET ion implanted device technology. A common pinch-off voltage was decided upon for each application. The beginning of the total integration phases revealed hitherto unencountered hazards of large microwave circuit integration which were successfully overcome. Yield and customer considerations finally led to two separate chips, one containing the power amplifiers and the other containing the complete five bit phase shifter.

Higgins, J. A.↗

Human factors of flight-deck checklists: The normal checklist

Although the aircraft checklist has long been regarded as the foundation of pilot standardization and cockpit safety, it has escaped the scrutiny of the human factors profession. The improper use, or the non-use, of the normal checklist by flight crews is often cited as the probable cause or at least a contributing factor to aircraft accidents. An attempt is made to analyze the normal checklist, its functions, format, design, length, usage, and the limitations of the humans who must interact with it. The development of the checklist from the certification of a new model to its delivery and use by the customer are discussed. The influence of the government, particularly the FAA Principle Operations Inspector, the manufacturer's philosophy, the airline's culture, and the end user, the pilot, influence the ultimate design and usage of this device. The effects of airline mergers and acquisitions on checklist usage and design are noted. In addition, the interaction between production pressures and checklist usage and checklist management are addressed. Finally, a list of design guidelines for normal checklists is provided.

Degani, Asaf↗

Improved Underwater Excitation-Emission Matrix Fluorometer

A compact, high-resolution, two-dimensional excitation-emission matrix fluorometer (EEMF) has been designed and built specifically for use in identifying and measuring the concentrations of organic compounds, including polluting hydrocarbons, in natural underwater settings. Heretofore, most EEMFs have been designed and built for installation in laboratories, where they are used to analyze the contents of samples collected in the field and brought to the laboratories. Because the present EEMF can be operated in the field, it is better suited to measurement of spatially and temporally varying concentrations of substances of interest. In excitation-emission matrix (EEM) fluorometry, fluorescence is excited by irradiating a sample at one or more wavelengths, and the fluorescent emission from the sample is measured at multiple wavelengths. When excitation is provided at only one wavelength, the technique is termed one-dimensional (1D) EEM fluorometry because the resulting matrix of fluorescence emission data (the EEM) contains only one row or column. When excitation is provided at multiple wavelengths, the technique is termed two-dimensional (2D) EEM fluorometry because the resulting EEM contains multiple rows and columns. EEM fluorometry - especially the 2D variety - is well established as a means of simultaneously detecting numerous dissolved and particulate compounds in water. Each compound or pool of compounds has a unique spectral fluorescence signature, and each EEM is rich in information content, in that it can contain multiple fluorescence signatures. By use of deconvolution and/or other mixture-analyses techniques, it is often possible to isolate the spectral signature of compounds of interest, even when their fluorescence spectra overlap. What distinguishes the present 2D EEMF over prior laboratory-type 2D EEMFs are several improvements in packaging (including a sealed housing) and other aspects of design that render it suitable for use in natural underwater settings. In addition, the design of the present 2D EEMF incorporates improvements over the one prior commercial underwater 2D EEMF, developed in 1994 by the same company that developed the present one. Notable advanced features of the present EEMF include the following: 1) High sensitivity and spectral resolution are achieved by use of an off-the-shelf grating spectrometer equipped with a sensor in the form of a commercial astronomical- grade 256 532-pixel charge-coupled-device (CCD) array. 2) All of the power supply, timing, control, and readout circuits for the illumination source and the CCD, ancillary environmental monitoring sensors, and circuitry for controlling a shutter or filter motor are custom-designed and mounted compactly on three circuit boards below a fourth circuit board that holds the CCD (see figure). 3) The compactness of the grating spectrometer, CCD, and circuit assembly makes it possible to fit the entire instrument into a compact package that is intended to be maneuverable underwater by one person. 4) In mass production, the cost of the complete instrument would be relatively low - estimated at approximately $30,000 at 2005 prices.

Moore, Casey↗

Mechanical Characterization of Electrolyzer Membranes and Components Under Compression

Proton-exchange membrane (PEM) water electrolysis is a promising technology for producing clean hydrogen by electrochemically splitting water when paired with renewable energy sources. A major roadblock to improving electrolyzer durability is the mechanical degradation of the cell components, which requires an understanding of their mechanical response under device-relevant conditions. However, there is a lack of studies on the mechanical characterization of the PEM and other components, as well as and their interactions. This study aims to address this gap by using a custom-designed testing apparatus to investigate the mechanics of electrolyzer components in uniaxial compression at 25 and 80 °C. Findings show stress-strain response of components have a varying degree of nonlinearity owing to their distinct deformation mechanisms and morphologies, from porous structures to polymers. These results are used to develop an expression for compressive stress-strain response of Nafion membranes and then analyze the deformation of components under applied pressure by using a 1-D spring network model of cell assembly. This work provides a new understanding of mechanical responses of the electrolyzer membrane and cell components, which can help assess material design and cell assembly strategies for improved electrolyzer durability.

08 HYDROGEN↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Lightweight High Efficiency Electric Motors for Space Applications

Lightweight high efficiency electric motors are needed across a wide range of space applications from - thrust vector actuator control for launch and flight applications to - general vehicle, base camp habitat and experiment control for various mechanisms to - robotics for various stationary and mobile space exploration missions. QM Power?s Parallel Path Magnetic Technology Motors have slowly proven themselves to be a leading motor technology in this area; winning a NASA Phase II for "Lightweight High Efficiency Electric Motors and Actuators for Low Temperature Mobility and Robotics Applications" a US Army Phase II SBIR for "Improved Robot Actuator Motors for Medical Applications", an NSF Phase II SBIR for "Novel Low-Cost Electric Motors for Variable Speed Applications" and a DOE SBIR Phase I for "High Efficiency Commercial Refrigeration Motors" Parallel Path Magnetic Technology obtains the benefits of using permanent magnets while minimizing the historical trade-offs/limitations found in conventional permanent magnet designs. The resulting devices are smaller, lower weight, lower cost and have higher efficiency than competitive permanent magnet and non-permanent magnet designs. QM Power?s motors have been extensively tested and successfully validated by multiple commercial and aerospace customers and partners as Boeing Research and Technology. Prototypes have been made between 0.1 and 10 HP. They are also in the process of scaling motors to over 100kW with their development partners. In this paper, Parallel Path Magnetic Technology Motors will be discussed; specifically addressing their higher efficiency, higher power density, lighter weight, smaller physical size, higher low end torque, wider power zone, cooler temperatures, and greater reliability with lower cost and significant environment benefit for the same peak output power compared to typically motors. A further discussion on the inherent redundancy of these motors for space applications will be provided.

Robertson, Glen A.↗

NASA's Ground-Based Microgravity Simulation Facility

Since opportunities to conduct experiments in space are scarce, various microgravity simulators and analogs have been widely used in space biology ground studies. Even though microgravity simulators do not produce all of the biological effects observed in the true microgravity environment, they provide alternative test platforms that are effective, affordable, and readily available to facilitate microgravity research. The Microgravity Simulation Support Facility (MSSF) at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC) has been established for conducting short duration experiments, typically less than 1 month, utilizing a variety of microgravity simulation devices for research at different gravity levels. The simulators include, but are not limited to, 2D Clinostats, 3D Clinostats, Random Positioning Machines, and Rotating Wall Vessels. In this chapter, we will discuss current MSSF capabilities, development concepts, customized sample holder designs, and the physical characteristics of these microgravity simulators.

Ye Zhang↗

Probing plexciton emission from 2D materials on gold nanotrenches

Probing strongly coupled quasiparticle excitations at their intrinsic length scales offers unique insights into their properties and facilitates the design of devices with novel functionalities. In this work, we investigate the formation and emission characteristics of plexcitons, arising from the interaction between surface plasmons in narrow gold nanotrenches and excitons in monolayer WSe 2 . We study this strong plasmon–exciton coupling in both the far-field and the near-field. Specifically, we observe a Rabi splitting in the far-field reflection spectra of about 80 meV under ambient conditions, consistent with our theoretical modeling. Using a custom-designed near-field probe, we find that plexciton emission originates predominantly from the lower-frequency branch, which we can directly probe and map its local field distribution. We precisely determine the plexciton's spatial extension, similar to the trench width, with nanometric precision by collecting spectra at controlled probe locations. Our work opens exciting prospects for nanoscale mapping and engineering of plexcitons in complex nanostructures with potential applications in nanophotonic devices, optoelectronics, and quantum electrodynamics in nanoscale cavities.

36 MATERIALS SCIENCE↗

Malware Analysis Report for SolarWinds.Orion.Core.BusinessLayer.dll

SolarWinds Orion is a software suite designed to provide “single pane of glass” monitoring of network devices and applications. On December 13 2020, FireEye revealed that SolarWinds Orion was the victim of a supply chain attack and that the SolarWinds signed file SolarWinds.Orion.Core.BusinessLayer.dll contained a backdoor. SolarWinds deployed the back-doored patch to customers beginning in March 2020. FireEye first identified this backdoor and labeled it SUNBURST. The backdoor is composed of roughly 4,000 lines1 of lightly obfuscated .NET within the SolarWinds.Orion.Core.BusinessLayer.OrionImprovementBusinessLayer class of the malicious dll. The backdoor’s capabilities include: the ability to detect and potentially disable antivirus and forensics tools, basic command and control via DNS, and more advanced command and control via HTTP.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Forced Crowding of Colloids by Thermophoresis and Convection in a Custom Liquid Clusius–Dickel Microdevice

Here, we report a study demonstrating that simultaneous induction of a steady-state convection current and temperature gradient in a confined geometry can be an effective way to force crowding of dissolved particulates. To investigate this thermogravitationally driven concentration of particles in-situ, we developed a micro-device capable of sustaining controlled transverse temperature gradients within a 5 cm long, 0.1 mm inner diameter capillary that allowed visualization of particle movement with standard optical microscopy. Experiments were conducted on two material systems representative of nano-scale small molecules and micro-scale particles. With the small molecules (aromatic dyes, 530-790 g/mol, 1-1.5 nm) thermophoretic and gravitational effects in the micro-device resulted in an asymmetrical 2x concentration change along the capillary height over 3 days. In contrast, the concentration change under similar conditions for 40-micron diameter latex colloids is 50-fold in 30 minutes. This dramatic difference in separation times is consistent with simulations and models of thermophoresis where the thermophoretic effect scales with particle size. Induced crowding of particulates leads to formation of accumulation and depletion zones in at the bottom and top of the capillary respectively. Both the concentration of dye molecules over time in the depletion zone and spatial distribution of colloids over the entire capillary length were found to be good fits to simple first-order exponential decay functions. Furthermore, these results suggest potential applications of thermogravitational separation in developing new functional materials via thermophoretic and convective effects.

36 MATERIALS SCIENCE↗

Metall: A persistent memory allocator for data-centric analytics

Data analytics applications transform raw input data into analytics-specific data structures before performing analytics. Unfortunately, such data ingestion steps are often more expensive than analytics. In addition, various types of NVRAM devices are already used in many HPC systems today. Such devices will be useful for storing and reusing data structures beyond a single process life cycle. We developed Metall, a persistent memory allocator built on top of the memory-mapped file mechanism. Metall enables applications to transparently allocate custom C++ data structures into various types of persistent memories. Metall incorporates a concise and high-performance memory management algorithm inspired by Supermalloc and the rich C++ interface developed by Boost.Interprocess library. On a dynamic graph construction workload, Metall achieved up to 11.7x and 48.3x performance improvements over Boost.Interprocess and memkind (PMEM kind), respectively. We also demonstrate Metall’s high adaptability by integrating Metall into a graph processing framework, GraphBLAS Template Library. Here this study’s outcomes indicate that Metall will be a strong tool for accelerating future large-scale data analytics by allowing applications to leverage persistent memory efficiently.

97 MATHEMATICS AND COMPUTING↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Volumetric Assessment of UPRITE Exercises From Marker-Based Motion Capture

BACKGROUND Lack of volumetric data on full-body movement of exercises presents a challenge to ensuring the fit of crew member’s full range of motion on the International Space Station (ISS). The Upright Proprioception Retention via In-flight Training and Evaluation (UPRITE) is a sensorimotor countermeasure device designed for maintaining crew members’ proprioception in a microgravity environment. A footplate—attached to a static base—rotates in two degrees of freedom (pitch and roll) up to a 20 deg angle. An initial volumetric assessment assuming an upright standing posture produced a cone-like shape with a narrow bottom and wide top. Such general volumetric assessments risk creating an overly conservative volume estimate, taking up more space than is necessary on the already limited interior space of the ISS, and neglecting necessary volume due to oversimplifying assumptions. Rather, higher-fidelity volumetric assessments offer more comprehensive insights in an environment where every area counts. The main objective of this work is to provide the spatial parameters of exercises on the UPRITE such that it is placed on the ISS according to its volumetric demands or that usage is adjusted to fit the available space. METHODS In 2023, a data collection was performed originally to inform loads and dynamics of system use and was recently leveraged for volumetric assessment. Three human subjects representing different body types (~63-76 inches in stature) performed a variety of board manipulations using UPRITE with body weight offload. The test collected the 3D positional data of a modified full-body Plug-in Gait marker set [1] via a 16-camera OptiTrack MoCap system. After processing – filling marker gaps and trimming data – in OptiTrack Motive, the recorded marker location data, which included device markers, was exported to a readable trajectory file. To accurately represent the full volume defining landmarks, additional markers were digitally added to an unscaled Modified Full Body Model [2]. The model was then scaled according to its subject parameters upon which an inverse kinematics analysis was performed. A custom plugin yielded model marker location data files. Volumetric analyses were performed on the recorded trajectory and model trajectory files using a custom Python-built tool that extracted the marker location data and plotted it in a 3D space. Concerned with only the maximum volume of the motion, a 3D convex hull analysis was applied to the plot, extracting the vertices or external points of the eventual 3D CAD output, dubbed aptly as a “volume shell”. This overall approach was based on guidance in a NASA-STD-3001 Technical Brief [3]. RESULTS AND DISCUSSION Batch volumetric assessment on the exercises for each subject was performed, producing high-fidelity volume shells in minimal time. Preliminary results highlighted the value in higher-fidelity volumes based on collected data when possible. For example, revolving a single posture in the cone assessment would not have sufficiently captured a single leg stance; rather, it would need to involve swinging the leg both forward and back. Additional observations and the maximal dimensions of the volumes, including those based on scaled data for ISS anthropometric requirements, will be presented at the Human Research Program Investigator’s Workshop. CONCLUSIONS While this work’s primary objective was for the UPRITE-to-ISS integration, the tool built to conduct this analysis has wide applications for future exercise systems as an informational tool for optimal device placement. The tool and its findings also have implications for exercise device design and spacecraft interior considerations on Gateway, the Lunar Pressurized Rover, and beyond. REFERENCES [1] Bell, C. A., et al. (2023) Recent Improvements and Verification of a Full Body Model in OpenSim. NASA Human Research Program Investigator’s Workshop. https://ntrs.nasa.gov/citations/20230001080 [2] Lostroscio, K., et al (2023) The Digital Astronaut Simulation. AHFE International Conference on Human Factors in Design, Engineering, and Computing for All. [3] Exercise Overview. (2023) NASA-STD-3001 Technical Brief. https://www.nasa.gov/wp-content/uploads/2023/12/ochmo-tb-031-exercise-overview.pdf?emrc=9d454c?emrc=9d454c

L D Quinto↗

Chemical Design of Organic Interface Modifiers for Highly Efficient and Stable Perovskite Solar Cells

Perovskite solar cells (PSCs) have demonstrated rapid progress in their power conversion efficiencies (PCEs) - from 3.8% in 2009 to 25.7% in 2022 - and they have received considerable attention as a promising future photovoltaic (PV) technology. However, the operational stability of PSCs is still inadequate to satisfy the standards for commercial applications. Interface engineering has become one of the most important strategies to push PSCs' efficiency and stability for practical use. Among the various interface engineering approaches, organic interface modifiers (OIMs) have been frequently used by the PSC field to address the issues limiting PSC stability at high efficiency levels. In this perspective, the chemical structures of state-of-the-art OIMs are discussed, and their characteristics are reviewed, as well as the impact on device performance associated with key device interfaces (e.g., metal oxide/perovskite and organic transport layer/perovskite interfaces) from a chemical and materials engineering point of view is discussed. Finally, design considerations and the authors' perspective are discussed, on the basis of representative literature examples, for building new, customized organic OIMs to further improve PSC efficiency and stability toward commercialization.

14 SOLAR ENERGY↗

A cleanroom in a glovebox

The exploration of new materials, novel quantum phases, and devices requires ways to prepare cleaner samples with smaller feature sizes. Initially, this meant the use of a cleanroom that limits the amount and size of dust particles. However, many materials are highly sensitive to oxygen and water in the air. Furthermore, the ever-increasing demand for a quantum workforce, trained and able to use the equipment for creating and characterizing materials, calls for a dramatic reduction in the cost to create and operate such facilities. To this end, we present our cleanroom-in-a-glovebox, a system that allows for the fabrication and characterization of devices in an inert argon atmosphere. Additionally, we demonstrate the ability to perform a wide range of characterization as well as fabrication steps, without the need for a dedicated room, all in an argon environment. Finally, we discuss the custom-built antechamber attached to the back of the glovebox. This antechamber allows the glovebox to interface with ultra-high vacuum equipment such as molecular-beam epitaxy and scanning tunneling microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗

Using neural networks to assist in OPAD data analysis

The space shuttle main engine (SSME) became the subject of plume emission spectroscopy in 1986 when researchers from NASA-Marshall Space Flight Center (MSFC), Arnold Engineering Development Center (AEDC), and Rocketdyne went to the SSME test stands at the NASA-Stennis Space Center and at Rocketdyne's Santa Susan Field Laboratory to optically observe the plume. Since then, plume spectral acquisitions have recorded many nominal tests and the qualitative spectral features of the SSME plume are now well established. Significant discoveries made with both wide-band and narrow-band plume emission spectroscopy systems led MSFC to promote the Optical Plume Anomaly Detection (OPAD) program with a goal of instrumenting all SSME test stands with customized spectrometer systems. A prototype OPAD system is now installed on the SSME Technology Test Bed (TTB) at MSFC. The OPAD system instrumentation consists of a broad-band, optical multiple-channel analyzer (OMA) and a narrow-band device called a polychrometer. The OMA is a high-resolution (1.5-2.0 Angstroms) 'super-spectrometer' covering the near-ultraviolet to near-infrared waveband (2800-7400 Angstroms), providing two scans per second. The polychrometer consists of sixteen narrow-band radiometers: fourteen monitoring discrete wavelengths of health and condition monitoring elements and two dedicated to monitoring background emissions. All sixteen channels are capable of providing 500 samples per second. To date, the prototype OPAD system has been used during 43 SSME firings on the TTB, collecting well over 250 megabytes of plume spectral data. One goal of OPAD data analysis is to determine interatively with the help of a computer code, SPECTRA4, developed at AEDC. Experience has shown that iteration with SPECTRA4 is an incredibly labor intensive task and not one to be performed by band. What is really needed is the 'inverse' of SPECTRA4 but the mathematical model for this inverse mapping is tenuous at best. However, the robustness of PSECTRA4 run in the 'forward' direction means that accurate input/output mappings can be obtained. If the mappings were inverted (i.e., input becomes output and output becomes input) then an 'inverse' of SPECTRA4 would be at hand but the 'model' would be specific to the data utilized and would in no way be general. Building a generalized model based upon known input/output mappings while ignoring the details of the governing physical model is possible through the use of a neural network. The research investigation described involves the development of a neural network to provide a generalized 'inverse' of SPECTRA4. The objectives of the research were to design an appropriate neural network architecture, train the network, and then evaluate its performance.

Whitaker, Kevin W.↗