Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Thermal and Electrical Properties of Isocyanate Derived Organic Aerogels for Cryogenic Insulation Applications

The use and storage of cryogens such as liquefied nitrogen, helium, hydrogen among others requires reliable and efficient thermal insulation systems. Passive insulation from high performance materials that are well-known for their inherent low thermal conductivity would reduce the overall costs involved in design, manufacture and maintenance of such systems. One such class of materials are referred to as aerogels. These materials are known for their low density, high mesoporosity, high surface areas, low thermal conductivity and high acoustic impedance. Aerogels were invented by S.S. Kistler in 1931 and the most common type are those made of silica. However, the inherent fragility of silica aerogels makes them hard to mass produce, and therefore applications have been limited. A major breakthrough was introduced by our team almost 20 years ago with the invention of polymer crosslinked silica aerogels. Those materials shifted attention to all-polymer aerogels that have overcome all fragility issues associated with their inorganic counterparts. This study focuses on such polymeric aerogels that can be mass produced as large monoliths while maintaining the low thermal conductivity of traditional silica aerogels over a wide temperature range. Manufacturing flexibility of polymeric aerogels allows fabrication of blocks and sheets that can be applied in various configurations to insulate cryogenic and superconducting devices. The thermal conductivity with 80 K and room temperature boundary are reported as well as other properties (electrical), that need to be considered when designing devices for cryogenic applications.

Churu, Gitogo↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator↗

A quantitative assessment of (bacterio)chlorophyll assignments in the cryo-EM structure of the Chloracidobacterium thermophilum reaction center

Chlorophylls and bacteriochlorophylls are the primary pigments used by photosynthetic organisms for light-harvesting, energy transfer, and electron transfer. Many molecular structures of (bacterio)chlorophyll-containing protein complexes are available, some of which contain mixtures of different (bacterio)chlorophyll types. Differentiating these, which sometimes are structurally similar, is challenging but is required for leveraging structural data to gain functional insight. The reaction center complex from Chloroacidobacterium thermophilum has a hybrid (bacterio)chlorophyll antenna system containing both chlorophyll a and bacteriochlorophyll a molecules. The recent availability of its cryogenic electron microscopy (cryo-EM) structure provides an opportunity for a quantitative analysis of their identities, and chemical environments. Here, we describe a theoretical basis for differentiating chlorophyll a and bacteriochlorophyll a in a cryo-EM map, and apply the approach to the experimental cryo-EM maps of the (bacterio)chlorophyll sites of the chloroacidobacterial reaction center. The comparison reveals that at ~2.2-Å resolution, chlorophyll a and bacteriochlorophyll a are easily distinguishable, but the orientation of the bacteriochlorophyll a acetyl moiety is not; however, the latter can confidently be assigned by identifying a hydrogen bond donor from the protein environment. Furthermore, this study reveals the opportunities and challenges in assigning (bacterio)chlorophyll types in structural biology, the accuracy of which is vital for downstream investigations.

59 BASIC BIOLOGICAL SCIENCES↗

A Field-Enhanced Conduction-Cooled Superconducting Cavity for High-Repetition-Rate Ultrafast Electron Bunch Generation

High-repetition-rate sources of bright electron bunches have a wide range of applications. They can directly be employed as probes in electron-scattering setups, or serve as a backbone for the generation of radiation over a broad range of the electromagnetic spectrum. This paper describes the development of a compact sub-Mega-electronvolt (sub-MeV) electron-source setup capable of operating at MHz repetition rates and forming sub-picosecond electron bunches with transverse emittance below 20 nm. The setup relies on a conduction-cooled superconducting single-cell resonator with its geometry altered to enhance the field at the surface of the emitter. The system is designed to accommodate cooling using a 2 W pulse-tube cryogen-free cryocooler operated at 4.2 K. Although we focus on the case of a photoemitted electron bunch, the scheme could be adapted to other emission mechanisms.

43 PARTICLE ACCELERATORS↗

Hyperspectral imaging of exciton confinement within a moiré unit cell with a subnanometer electron probe

Electronic and optical excitations in two-dimensional systems are distinctly sensitive to the presence of a moiré superlattice. Here we used cryogenic transmission electron microscopy and spectroscopy to simultaneously image the structural reconstruction and associated localization of the lowest-energy intralayer exciton in a rotationally aligned WS 2 -WSe 2 moiré superlattice. In conjunction with optical spectroscopy and ab initio calculations, we determined that the exciton center-of-mass wave function is confined to a radius of approximately 2 nanometers around the highest-energy stacking site in the moiré unit cell. Our results provide direct evidence that atomic reconstructions lead to the strongly confining moiré potentials and that engineering strain at the nanoscale will enable new types of excitonic lattices.

36 MATERIALS SCIENCE↗

Detecting Atmospheric Molecules of Nontransiting Temperate Terrestrial Exoplanets Using High-resolution Spectroscopy in the Mid-infrared Domain

Motivated by the development of high-dispersion spectrographs in the mid-infrared (MIR) range, we study their application to the atmospheric characterization of nearby nontransiting temperate terrestrial planets around M-type stars. We examine the detectability of CO{sub 2}, H{sub 2}O, N{sub 2}O, and O{sub 3 }features in high-resolution planetary thermal emission spectra at 12–18 μm assuming an Earth-like profile and a simplified thermal structure. The molecular line width of such planets can be comparable to or broader than the Doppler shift due to the planetary orbital motion. Given the likely difficulty in knowing the high-resolution MIR spectrum of the host star with sufficient accuracy, we propose observing the target system at two quadrature phases and extracting the differential spectra as the planetary signal. In this case, the signals can be substantially suppressed compared with the case where the host star spectrum is perfectly known, as some parts of the spectral features do not remain in the differential spectra. Despite this self-subtraction, the CO{sub 2} and H{sub 2}O features of nearby (≲5 pc) systems with mid-/late-M host stars would be feasible with a 6.5 m class cryogenic space telescope, and orbital inclination could also be constrained for some of them. For CO{sub 2} and N{sub 2}O in a 1 bar Earth-like atmosphere, this method would be sensitive when the mixing ratio is 1–10{sup 3} ppm. The detectability of molecules except O{sub 3} is not significantly improved when the spectral resolution is higher than R≳10,000, although the constraint on the orbital inclination is improved. This study provides some benchmark cases useful for assessing the value of MIR high-resolution spectroscopy in terms of characterization of potentially habitable planets.

47 OTHER INSTRUMENTATION↗

CMB-S4 Instrument Modeling and Development for CMB-S4

During this thirteen month award, we focused on two main tasks relevant to the development of the CMB-S4 project: (1) The refinement of sensitivity models and use of those to optimize the instrument design, and (2) the final development and testing a cryogenic blackbody calibrator prototype, of which we then produced three copies for CMB-S4's detector testing systems at FNAL, SLAC and UIUC.

47 OTHER INSTRUMENTATION↗

Impact of breech geometry and propellant flow on the release of large pellets for the ITER disruption mitigation system

Studies have been performed on the release mechanism for large pellets using high pressure gas in a shattered pellet injector. Typically, pellets are dislodged from the cryogenic surface and accelerated down a barrel using high pressure gas delivered by a fast-acting propellant valve. The pellets impact an angled surface which shatters the pellet into many small fragments before entering the plasma. This technique was initially demonstrated on DIII-D (Commaux et al 2016 Nucl. Fusion 56 046007) and is now deployed on JET, KSTAR, ASDEX-Upgrade, and other tokamaks around the world in support of ITER's disruption mitigation system design and physics basis. The large hydrogen, 28.5 mm diameter, 2 length-to-diameter ratio, pellets foreseen for ITER SPI operation have low material strength and low heat of sublimation, which cause the pellets to be fragile and highly reactive to the impact of warm propellant gas. Due to the size of the pellets, significantly more propellant gas is required to dislodge and accelerate them. This creates a potentially significant propellant gas removal issue as 2–6 bar-L of gas is expected to be required for release and speed control. The research presented in this paper is an in-depth exploration of the parameters that are keys to reliable pellet release and speed control. Computational fluid dynamics (CFD) modeling of propellant flows through various breech designs was conducted to determine the force generated on the back surface of a pellet. These simulations assumed the use of the ORNL designed flyer plate valve. CFD modeling combined with experimental measurements provide adequate insight to determine a path to an optimal valve and breech design for ITER SPI pellet release and speed control while minimizing propellant gas usage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab

Ensuring High-Purity Liquid Argon for the LBNF FDC: Collaborative Cryogenics Research Between UNICAMP and Fermilab R. Doubnik1, M. Adamowski1, F. de M. Blaszczyk1, A. Hahn1, D. Montanari1, R. Mrowca1, Z. West1, C. Adriano2, T. P.M. Alegre2, D. Correia2, A. A. B. Machado2, E. Segreto2, R. G. Gonçalves3, E. M. Assaf6, J. M. Assaf3, D. Cardoso3, M. B. Fontes4, H. Da Motta4, D. Noriler5, P. J. G. Pagliuso2. 1 Fermi National Accelerator Laboratory, PO Box 500, Batavia IL 60510, United States. 2 “Gleb Wataghin” Institute of Physics, UNICAMP, Campinas-SP, 13083-859, Brazil. 3 CPqMAE - Research Center on Advanced Materials and Energy, Federal University of São Carlos (UFSCar), São Carlos, 13565-905, Brazil. 4 The Brazilian Center for Research in Physics (CBPF), Rio de Janeiro-RJ, 22290-180, Brazil. 5 School of Chemical Engineering, UNICAMP, Campinas-SP, 13083-859, Brazil. 6 São Carlos Institute of Chemistry, University of São Paulo, São Carlos-SP, 13566-590, Brazil. Email: rdoubnik@fnal.gov Abstract. The Long-Baseline Neutrino Facility (LBNF) located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, hosts the Deep Underground Neutrino Experiment (DUNE). This experiment employs cryostats containing nearly 70,000 metric tons of high-purity liquid argon (LAr). Ensuring LAr purity is critical for achieving the required electron lifetime, which directly impacts the experiment’s signal-to-noise ratio. The Horizontal Drift (HD) detector demands an electron lifetime exceeding 3 ms within its 3.5 m drift, equivalent to less than 100 parts-per-trillion (ppt) Oxygen contamination, while the Vertical Drift (VD) detector requires over 6 ms electron lifetime within its 6.0 m drift, corresponding to less than 50 ppt Oxygen contamination. To mitigate Nitrogen (N2) quenching of scintillation light, N2 contamination must remain below 1 ppm, as higher levels can result in up to a 20 % loss of light. The Brazil State University of Campinas (UNICAMP) significantly contributes to LBNF FDC through the development of argon purification and regeneration systems for HD and VD cryostats. UNICAMP designed and constructed the Purification Liquid Argon Cryostat (PuLArC), a small-scale test facility holding approximately 90 liters of LAr. Tests using PuLArC demonstrated that 1.2 kg of Li-FAU zeolite could reduce N₂ contamination from 20-50 ppm to 0.1-1.0 ppm within 1-2 hours. Tests at Fermilab’s Iceberg cryostat (2,596 liters) confirmed scalability, with 3 kg of Li-FAU reducing N₂ contamination from ~5 ppm to <1 ppm over 96 hours cycles without active circulation. This presentation will detail the research methods, test setups, and results, showcasing the potential of Li-FAU as an alternative to Molecular Sieve 4A for large-scale LAr systems. This advancement enhances DUNE's precision and demonstrates the impact of international collaboration on cryogenic research.

Doubnik, Roza [Fermilab]↗

Colossal Strain Tuning of Ferroelectric Transitions in KNbO 3 Thin Films

Strong coupling between polarization ( P ) and strain (ɛ) in ferroelectric complex oxides offers unique opportunities to dramatically tune their properties. Here colossal strain tuning of ferroelectricity in epitaxial KNbO 3 thin films grown by sub‐oxide molecular beam epitaxy is demonstrated. While bulk KNbO 3 exhibits three ferroelectric transitions and a Curie temperature ( T c ) of ≈676 K, phase‐field modeling predicts that a biaxial strain of as little as −0.6% pushes its T c > 975 K, its decomposition temperature in air, and for −1.4% strain, to T c > 1325 K, its melting point. Furthermore, a strain of −1.5% can stabilize a single phase throughout the entire temperature range of its stability. A combination of temperature‐dependent second harmonic generation measurements, synchrotron‐based X‐ray reciprocal space mapping, ferroelectric measurements, and transmission electron microscopy reveal a single tetragonal phase from 10 K to 975 K, an enhancement of ≈46% in the tetragonal phase remanent polarization ( P r ), and a ≈200% enhancement in its optical second harmonic generation coefficients over bulk values. These properties in a lead‐free system, but with properties comparable or superior to lead‐based systems, make it an attractive candidate for applications ranging from high‐temperature ferroelectric memory to cryogenic temperature quantum computing.

36 MATERIALS SCIENCE↗

Molecular Vibrational Polaritons Towards Quantum Technologies

In this paper molecular vibrational polaritons (MVPs)—a hybrid molecular-photon quasiparticle—and the development of a proof-of-principle quantum technology platform are discussed to simulate coherence transfer, for use at room temperature. It is shown that MVPs can form qubits, coherence, and have nonlinear interactions, all at room temperature. Some new insights, such as polaritonic nonlinearity dependence on macroscopic properties including cavity thickness and molecular concentrations are also uncovered. It is hoped that these advances can stimulate more research in developing this system into a quantum technology platform free from the constraints imposed by the requirement of cryogenic conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent Control over Nuclear Hyperpolarization Using an Optically Initializable Chromophore-Radical System

Chromophore radicals (CR) are emerging as important components for molecular quantum information science (QIS), especially in the context of quantum sensing. Here, we demonstrate that the optically hyperpolarized electrons in a 1,6,7,12-tetrakis(4-tert-butylphenoxy)-perylene-3,4,9,10-bis(dicarboximide) (tpPDI) covalently linked to a partially deuterated 1,3-bis(diphenylene)-d 16 -2-phenylallyl radical (BDPA-d 16 ) can be coherently manipulated via pulsed dynamic nuclear polarization (DNP) methods to transfer polarization to nuclear spins and back. Under light illumination at 85 K, electron hyperpolarization in BDPA is enhanced 2.1- to 2.4-fold over thermal polarization and lasts for more than 100 ms. By applying nuclear orientation via electron spin-locking (NOVEL) DNP, this optically amplified electron hyperpolarization was successfully transferred to a 1 H nuclear spin within the CR system and efficiently returned to the electron spin for readout via reverse-NOVEL. The NOVEL transfer efficiency of 65% amounts to a 688-fold nuclear spin hyperpolarization of the target nuclear spin, considering the 2.1-fold electron spin hyperpolarization. This reversible coherent manipulation of hyperpolarization transfer highlights the utility of CR systems to initialize and read out nuclear spin states in a disordered matrix at moderate cryogenic temperatures. Coupled with CRs’ environmental compatibility, tunability, and precise state initialization, these results highlight the promising role of nuclear spins in CRs for QIS applications, including quantum sensing and memory.

charge transfer↗

High frequency lithium niobate film-thickness-mode optomechanical resonator

High-frequency optomechanical resonators are in demand as transduction devices to bridge microwave and optical fields. Thin-film lithium niobate is a promising platform for implementing high-frequency optomechanics for its low optical loss and strong piezoelectric coefficients. However, its strong piezoelectricity is also known to introduce excess phonon loss. Here, we present lithium niobate optomechanical resonators with film-thickness-mode mechanical resonances up to 5.2 GHz, reaching the operating frequency regime of superconducting qubits. By engineering the mechanical anchor to minimize the phonon loss, we achieve a high quality factor up to 12 500 at cryogenic temperatures and, hence, a frequency-quality factor product of 6.6 × 10 13 . Our system also features interference between piezo-optomechanical and electro-optic modulation. A theoretical model is derived to analyze these two effects and their interference.

42 ENGINEERING↗

Martensitic transformation in superlattices of two non-transforming metals

A number of studies have shown that the coherent integration of a second non-transforming phase in martensitic materials results in unprecedented thermo-mechanical properties. We demonstrate the possibility of martensitic transformation by epitaxially combining two non-transforming materials, Mg (hexagonal closed packed) and MgLi (body centered cubic). Density functional theory calculations predict that MgLi/Mg superlattices undergo a transformation crystallographically equivalent to MgSc alloys and can be expected to result in finite temperature shape memory behavior. We predict the zero-temperature energy of the martensite phase to be 9.3 meV/atom lower than austenite for a 50–50 at. % MgLi/Mg nanolaminate, which is expected to result in a martensitic transformation temperature of approximately 150 K. This energy difference can be tuned between 4.9 and 18.1 meV/atom by varying the fraction of the pure Mg phase in the superlattice, potentially enabling the transformation from cryogenic to room and higher temperatures. While Li diffusion might limit the applications of the systems proposed, this work opens the door to a new approach to create martensitic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗