Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “criticality benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

IER 557: Godiva Pulse Repeatability and Characterization (CED-3A Report)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. Godiva IV is proposed as the radiation source for IER 498: Design a Shielding Benchmark with a Metal Critical Source. IER 498 proposes a two-burst method to determine the performance of shielding samples, comparing the transmission of the source radiation to detectors with and without a shielding sample present. This eliminates the need for an absolute calibration and allows many uncertainties to cancel. However, the source term variability must be low compared to other sources of experimental uncertainty to ensure the overall uncertainty meets acceptable levels to provide useful measurements. The primary goal of this experiment is to quantify the source term variability, or reproducibility, of Godiva bursts, focusing on the 70 °C bursts planned for IER 498 measurements. Discussions during IER 498 noted that a number of bursts (on the order of six to ten) as identical as possible would be performed and that a 5-7% standard deviation in source intensity would be acceptable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE

Analyses of cross section sensitivity data from systems with fissile material allow analysts to associate an importance for each material, nuclide, reaction, and neutron energy by simulating real world criticality scenarios. Although criticality safety validation efforts can be guided by the cross-section sensitivity and uncertainty data generated for a particular system, these calculations can often be computationally expensive and sometimes cumbersome without proper guidance. The TSUNAMI suite within the SCALE code package has several methods for generating sensitivity data, including multigroup and continuous energy (CE) capabilities. The release of SCALE 6.3 has three different CE methods for generating cross section sensitivity data: (1) the Iterated Fission Probability (IFP) method with the KENO Monte Carlo transport solver, (2) the IFP method with the Shift Monte Carlo transport solver, and (3) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method with the KENO Monte Carlo transport solver. Although the CLUTCH method has additional parameters for generating sensitivity data files relative to the IFP method, all three methods use latent generations, which are the generations between an event (i.e., fission) and the assessment of importance based on the asymptotic population of progeny neutrons. Increasing the number of latent generations in a calculation leads to increased discrimination of the sensitivity coefficients but at the cost of the increased uncertainty associated with those generated values. Analysts must balance the accuracy of the sensitivity calculations and its uncertainty with the associated computational cost involved in generating the values. This paper discusses the impact of adjusting the latent generation parameter for a range of sensitivity values and how these changes compare with the direct perturbation values obtained from a change of ±0.5% Δ k in both benchmark and safety application models. Two benchmarks from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the MPC-32 dual purpose canister for spent nuclear fuel are used for analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Update on the Benchmark Analysis of the Jupiter Experiments: Plutonium Moderated by Lead

The Jupiter experiment was a series of measurements in the summer of 2017 to analyze the effects of voids in lead moderated plutonium assemblies. This experiment was part of a larger campaign that took place at the National Criticality Experiments Research Center (NCERC) in collaboration with the Japan Atomic Energy Agency (JAEA) that also investigated assemblies with differing uranium enrichments. The purpose for this campaign was to provide data useful for a potential lead-bismuth cooled accelerator driven system. This data is needed due to the low number of benchmarks involving lead. Given the wide use of lead for shielding in addition to new reactor designs, there is a need for further benchmarking that this experiment could help fulfill. In addition, adding more benchmarks to the International Criticality Safety Benchmark Evaluation Project (ICSBEP) is helpful for further validation of simulation methods used for criticality safety. This summary is an update on the current progress of this analysis, and all results shown are preliminary.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Results on Bayesian Inverse UQ for OECD/NEA WPNCS Subgroup 14 Benchmark Exercise for Error Recovery and Experimental Coverage

The Organization for Economic Cooperation and Development (OECD) Working Party on Nucelar Criticality Safety (WPNCS) has proposed a benchmark exercise representative of neutronic behavior in criticality experiments. Here, the goal is to develop confidence in data assimilation techniques used to adjust nuclear data. Participants are given synthetic experimental models with associated measured data and asked to estimate the model parameters given the model and measurements as well as provide predictions for separate application models. In this work, we performed data assimilation using Bayesian inverse Uncertainty Quantification (UQ) with machine learning surrogate models to produce posterior parameter distributions for the requested parameters and posterior predictive distributions for the requested responses. Several experimental models are shown to insufficiently inform the posterior parameter distributions for the applications involved. However, given sufficient experimental data, posterior parameter estimates yielded reduced uncertainty in the response predictions of interest while covering the experimental data.

Bayesian Inference↗

Verification of the Uniformly-Ordered Binary Decision Algorithm in Correlated-Benchmark Whisper Calculations

Whisper is a nuclear criticality safety code package that aids analysts in validation exercises by computing upper subcritical limits (USL) for applications of interest. To obtain statistically meaningful, significant, and conservative USLs, the analyst must ensure that Whisper selects a sufficient number of benchmarks that are neutronically similar to the application. Many of the available benchmarks are correlated but are currently treated as independent, leading to an artificially small sample size, as their individual information contributions will be overestimated. To aid the analyst in obtaining a sufficient sample size, prior work [2] demonstrated application of the Uniformly-Ordered Binary Decision (UOBD) algorithm in adjusting benchmark weights to account for benchmark correlations. This work provides verification of the Whisper implementation and considers the impact of updated benchmark correlations compared to those available previously. We demonstrate that the UOBD algorithm performs as expected with an analytic example. With HEU-SOL-THERM-001 cases 1 through 10 as the applications, we compare the USLs computed with benchmark correlations available in the Whisper 1.1 release only to those computed with additional benchmark correlations from DICE 2023 and demonstrate substantive differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark of the Chlorine Worth Study Experiments in Support of Chlorine Nuclear Data Validation for Nuclear Criticality Safety

The Chlorine Worth Study (CWS) was a critical experiment to address an urgent need for thermal chlorine nuclear data validation in plutonium systems. This urgent need is tied directly to plutonium recycle and recovery operations in the plutonium facility at Los Alamos National Laboratory, where exceptionally conservative criticality safety limits are used because no credit is taken for the neutron capture by chlorine. The experiment used weapons-grade plutonium metal plates clad in stainless steel, known as the PANN (plutonium aluminum no nickel) ZPPR (zero power physics reactor) plates. The plutonium was reflected and moderated by high-density polyethylene and included combinations of polyvinyl chloride (PVC) and chlorinated polyvinyl chloride (CPVC) as absorbers. The experiment and benchmark included three configurations mimicking 30 g 239 Pu/L plutonium, 300 g 239 Pu/L plutonium, and 600 g 239 Pu/L plutonium in an aqueous chloride solution. Uncertainties in the benchmark included five broad categories: (1) criticality measurement, (2) mass and density, (3) dimensions, (4) material compositions, and (5) positioning. The largest contribution to the overall uncertainties for all three cases came from the material compositions, in particular the PVC and CPVC absorber compositions. A detailed model was created to be a near match (that is within expectations of transport code users) and a simplified model was created to minimize offset dimensions and expedite modeling for code validation. Sample calculations were completed in MCNP6.3 with ENDF/B-VIII.0 and ENDF/B-VII.1 nuclear data. For the detailed and simplified models, the average difference between the computed and experimental k eff was 951 pcm. CWS will serve as the key validation experiment for nuclear criticality safety in support of aqueous chloride operations. The sensitivity to the chlorine capture cross section is orders of magnitude greater than other existing benchmarks. The current limits, as defined by nuclear criticality safety, are 520 g Pu per batch, i.e. the minimum critical mass of the Pu solution infinitely reflected by water [Criticality Handbook: Volume II, (1969)]. This extremely conservative critical mass limit does not credit any neutron capture by chlorine (in particular neutron capture by 35 Cl) and greatly impedes the throughput required for current and future operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Chlorine Worth Study Benchmark Evaluation

The Chlorine Worth Studies (CWS) experiments with polyvinyl chloride (PVC with chemical formula (C 2 H 3 Cl) n ), chlorinated polyvinyl chloride (CPVC with chemical formula (C 9 H 11 Cl 7 ) n ), and high density polyethylene (HDPE with chemical formula (CH 2 ) n ) were a series of measurements performed at the National Criticality Experiments Research Center (NCERC). The purpose of the CWS experiments was to perform integral experiments that were highly sensitive to the thermal 35 Cl(n,γ) reaction and matched the sensitivities of aqueous chloride operations at the plutonium facility at Los Alamos National Laboratory (LANL). The CWS experiments were performed on the Planet critical assembly machine at NCERC and utilized weapons grade plutonium (WGPu) plates as fuel. The design process and design of the CWS experiment were discussed previously. This paper discusses the benchmark evaluation of the experiment, intended for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Criticality calculations were performed with MCNP version 6.3. Results presented here are preliminary, as the benchmark has not yet been submitted to the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Data Adjustment for Nonlinear Applications in the OECD/NEA WPNCS SG14 Benchmark -- A Bayesian Inverse UQ-based Approach for Data Assimilation

The Organization for Economic Cooperation and Development (OECD) Working Party on Nuclear Criticality Safety (WPNCS) proposed a benchmark exercise to assess the performance of current nuclear data adjustment techniques applied to nonlinear applications and experiments with low correlation to applications. This work introduces Bayesian Inverse Uncertainty Quantification (IUQ) as a method for nuclear data adjustments in this benchmark, and compares IUQ to the more traditional methods of Generalized Linear Least Squares (GLLS) and Monte Carlo Bayes (MOCABA). Posterior predictions from IUQ showed agreement with GLLS and MOCABA for linear applications. When comparing GLLS, MOCABA, and IUQ posterior predictions to computed model responses using adjusted parameters, we observe that GLLS predictions fail to replicate computed response distributions for nonlinear applications, while MOCABA shows near agreement, and IUQ uses computed model responses directly. We also discuss observations on why experiments with low correlation to applications can be informative to nuclear data adjustments and identify some properties useful in selecting experiments for inclusion in nuclear data adjustment. Performance in this benchmark indicates potential for Bayesian IUQ in nuclear data adjustments.

FOS: Computer and information sciences↗

Nuclear Data Adjustment for Nonlinear Applications in the OECD/NEA WPNCS SG14 Benchmark—A Bayesian Inverse UQ-Based Approach for Data Assimilation

The Organisation for Economic Co-operation and Development Working Party on Nuclear Criticality Safety has proposed a benchmark exercise to assess the performance of current nuclear data adjustment techniques applied to nonlinear applications and experiments with low correlation to applications. This work introduces Bayesian inverse uncertainty quantification (IUQ) employing scientific machine learning surrogate models as a method for nuclear data adjustments in this benchmark, and compares IUQ to the more traditional methods of generalized linear least squares (GLLS) and Monte Carlo Bayes (MOCABA). Posterior predictions from IUQ showed agreement with GLLS and MOCABA for linear applications. Here, when comparing GLLS, MOCABA, and IUQ posterior predictions to computed model responses using adjusted parameters, we observe that the GLLS predictions failed to replicate the computed response distributions for nonlinear applications, while MOCABA showed near agreement, and IUQ used the computed model responses directly. We also discuss observations on why experiments with low correlation to applications can be informative to nuclear data adjustments and identify some properties useful in selecting experiments for inclusion in nuclear data adjustment. Performance in this benchmark indicates potential for Bayesian IUQ in nuclear data adjustments.

Bayesian calibration↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Planet Operations at NCERC

Planet is a vertical-lift assembly machine currently located at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. In the past, Planet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). Following the de-inventorying of LACEF, the Planet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The Class Foils experiment, which involves stacking highly enriched uranium foils to obtain a critical configuration, was the first critical experiment performed on Planet. As a major component of the Nuclear Criticality Safety Class taught for the U.S. Department of Energy (DOE) Nuclear Criticality Safety Program, the Class Foils experiment allows personnel from all over the DOE complex to handle nuclear material and to complete the approach to critical safely and successfully. This paper describes the Planet vertical assembly and recent engineering upgrade and a selection of the experiments that have been performed on Planet since its transition to NCERC 10 years ago.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Comet Operations at NCERC

Comet is a general-purpose, heavy-duty, vertical-lift assembly designed for flexibility in conducting a variety of critical experiments. It is currently located at the National Criticality Experiments Research Center (NCERC) in Nevada. In the past, Comet resided at Technical Area-18 in Los Alamos, New Mexico, as part of the Los Alamos Critical Experiments Facility (LACEF). The Comet assembly was relocated to NCERC in 2008 and became fully operational in June of 2011. The first critical experiment performed on Comet at NCERC was a verification of one of the previous configurations of the Zeus experiment series. Over the next 10 years, many additional experiments followed including other Zeus configurations as well as completely new designs. This paper discusses the Comet vertical-lift assembly, the transition from LACEF to NCERC, and a selection of experiments that have been performed on Comet during its first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Flattop Operations at NCERC

The Flattop critical assembly was built and operated from 1958 through 2004 at the Pajarito Site (Technical Area-18), home to the Los Alamos Critical Experiments Facility. Flattop was disassembled in 2005 and refurbished over the course of 3 years. In 2008, Flattop was installed in the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility at the Nevada National Security Site. Startup of Flattop with a uranium core occurred in 2011. This paper details the first 10 years of Flattop operations at NCERC (2011–present).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guide for Using ENDF/B-VIII.0 Nuclear Data with MCNP

This report provides guidance for using the ENDF/B-VIII.0 nuclear data that were released in 2018 and 2020 with MCNP. Appendix A: Obtaining and installing the new ENDF/B-VIII.0 ACE nuclear data. Appendix B. Obtaining & using XSDIR files that include ENDF/B-VIII.0 data. Appendix C: ENDF/B-VIII.0-based ACE files for neutron cross-sections. A listing of the available temperatures and ZA numbers for neutron cross-sections (ACE files with suffix .nnC). Appendix D: ENDF/B-VIII.0-based ACE files for thermal scattering law (TSL) data, $S$(α,β). A listing of the available thermal scattering $S$(α,β) data (ACE files with suffix .nnT) The next section below provides guidance for modifying existing $\textit{mcnp}$ input files to use the ENDF/B-VIII.0 data. Detailed results from running several benchmark suites for nuclear criticality safety with both ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data are reported in. It is important to note that this report deals only with TSL data released in 2020. With the original release of ENDF/B-VIII.0 in 2018, the ACE files for neutron cross-sections were contained in a directory called Lib80X and the ACE files for TSL data were contained in a directory called ENDF80SaB. A few years later, it was determined that many of the TSL data files had been generated with faulty data or with incorrect processing, and a new set of ACE files for TSL data was created, with the corrected files contained in directory ENDF80SaB2.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗