Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-E-J-179: Prediction of Pelvic Nodal Coverage Using Mutual Information Between Cone-Beam and Planning CTs

Purpose: To investigate if pelvic nodal coverage for prostate patients undergoing intensity modulated radiotherapy (IMRT) can be predicted using mutual image information computed between planning and cone-beam CTs (CBCTs). Methods: Four patients with high-risk prostate adenocarcinoma were treated with IMRT on a Varian TrueBeam. Plans were designed such that 95% of the nodal planning target volume (PTV) received the prescription dose of 45 Gy (N=1) or 50.4 Gy (N=3). Weekly CBCTs (N=25) were acquired and the nodal clinical target volumes and organs at risk were contoured by a physician. The percent nodal volume receiving prescription dose was recorded as a ground truth. Using the recorded shifts performed by the radiation therapists at the time of image acquisition, CBCTs were aligned with the planning kVCT. Mutual image information (MI) was calculated between the CBCT and the aligned planning CT within the contour of the nodal PTV. Due to variable CBCT fields-of-view, CBCT images covering less than 90% of the nodal volume were excluded from the analysis, resulting in the removal of eight CBCTs. Results: A correlation coefficient of 0.40 was observed between the MI metric and the percent of the nodal target volume receiving the prescription dose. One patient's CBCTs had clear outliers from the rest of the patients. Upon further investigation, we discovered image artifacts that were present only in that patient's images. When those four images were excluded, the correlation improved to 0.81. Conclusion: This pilot study shows the potential of predicting pelvic nodal dosimetry by computing the mutual image information between planning CTs and patient setup CBCTs. Importantly, this technique does not involve manual or automatic contouring of the CBCT images. Additional patients and more robust exclusion criteria will help validate our findings.

60 APPLIED LIFE SCIENCES↗

SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.

60 APPLIED LIFE SCIENCES↗

DMLC tracking and gating can improve dose coverage for prostate VMAT

Purpose: To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. Methods: A dose reconstruction method was used to retrospectively assess the dose distributions delivered without motion correction during volumetric modulated arc therapy fractions for 20 fractions of five prostate cancer patients who received conventionally fractionated radiotherapy. These delivered dose distributions were compared with the dose distributions which would have been delivered had DMLC tracking or gating motion correction strategies been implemented. The delivered dose distributions were constructed by incorporating the observed prostate motion with the patient's original treatment plan to simulate the treatment delivery. The DMLC tracking dose distributions were constructed using the same dose reconstruction method with the addition of MLC positions from Linac log files obtained during DMLC tracking simulations with the observed prostate motions input to the DMLC tracking software. The gating dose distributions were constructed by altering the prostate motion to simulate the application of a gating threshold of 3 mm for 5 s. Results: The delivered dose distributions showed that dosimetric effects of intrafraction prostate motion could be substantial for some fractions, with an estimated dose decrease of more than 19% and 34% from the planned CTVD{sub 99%} and PTV D{sub 95%} values, respectively, for one fraction. Evaluation of dose distributions for DMLC tracking and gating deliveries showed that both interventions were effective in improving the CTV D{sub 99%} for all of the selected fractions to within 4% of planned value for all fractions. For the delivered dose distributions the difference in rectum V{sub 65%} for the individual fractions from planned ranged from −44% to 101% and for the bladder V{sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.

60 APPLIED LIFE SCIENCES↗

MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

60 APPLIED LIFE SCIENCES↗

Break-Up of Stepped Platinum Catalyst Surfaces by High CO Coverage

Stepped single-crystal surfaces are viewed as models of real catalysts, which consist of small metal particles exposing a large number of low-coordination sites. We found that stepped platinum (Pt) surfaces can undergo extensive and reversible restructuring when exposed to carbon monoxide (CO) at pressures above 0.1 torr. Scanning tunneling microscopy and photoelectron spectroscopy studies under gaseous environments near ambient pressure at room temperature revealed that as the CO surface coverage approaches 100%, the originally flat terraces of (557) and (332) oriented Pt crystals break up into nanometer-sized clusters and revert to the initial morphology after pumping out the CO gas. Density functional theory calculations provide a rationale for the observations whereby the creation of increased concentrations of low-coordination Pt edge sites in the formed nanoclusters relieves the strong CO-CO repulsion in the highly compressed adsorbate film. This restructuring phenomenon has important implications for heterogeneous catalytic reactions.

Science & Technology - Other Topics↗

Influence of Binder Coverage on Interfacial Chemistry of Thin Film LiNi 0.6 Mn 0.2 Co 0.2 O 2 Cathodes

In this work, we explore the influence of binder coverage and chemistry on the interfacial properties of the textured Ni-rich cathode LiNi 0.6 Mn 0.2 Co 0.2 O 2 . We find that the formation of the cathode/electrolyte interphase (CEI) composition varies significantly for cathodes coated with either poly(vinylene fluoride) (PVDF), carboxymethyl cellulose (CMC), or lithium polyacrylate (LiPAA) after cycling to high upper cutoff voltages (4.5 V vs Li/Li). The PVDF-coated samples had a thinner CEI and twice the relative concentration of LiF and Li 2 CO 3 to Li x PO y F z species in the CEI compared to the uncoated sample. This correlated with significantly lower interfacial impedance (285 vs ~1700 Ohm-cm 2 ) and improved capacity retention between cycles of the PVDF-coated samples compared to the other binder compositions and the uncoated sample. CMC-coated samples performed worst, with a CEI comprised of greater amounts of Li x PO y F z . In addition, we find the choice of binder results in the selective protection or promotion of electrolyte reactions at the (104) surface of the 622 cathode. This suggests that the choice of binder can impact the surface chemistry and performance of high voltage cathodes and supports an avenue for interest in multifunctional binders for stabilizing the CEI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Landscape Characterization and Representativeness Analysis for Understanding Sampling Network Coverage

Sampling networks rarely conform to spatial and temporal ideals, often comprised of network sampling points which are unevenly distributed and located in less than ideal locations due to access constraints, budget limitations, or political conflict. Quantifying the global, regional, and temporal representativeness of these networks by quantifying the coverage of network infrastructure highlights the capabilities and limitations of the data collected, facilitates upscaling and downscaling for modeling purposes, and improves the planning efforts for future infrastructure investment under current conditions and future modeled scenarios. The work presented here utilizes multivariate spatiotemporal clustering analysis and representativeness analysis for quantitative landscape characterization and assessment of the Fluxnet, RAINFOR, and ForestGEO networks. Results include ecoregions that highlight patterns of bioclimatic, topographic, and edaphic variables and quantitative representativeness maps of individual and combined networks.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE Aboveground Vegetation Coverage in Root Ingrowth Core Plots, Marcell Experimental Forest, Minnesota, August 2022

This dataset contains vegetation survey measurements from root ingrowth core plots (Määttä et al. 2025) inside SPRUCE Experiment plots at the Marcell Experimental Forest in northern Minnesota. Vegetation surveys were conducted in 0.25 meter2 plots containing root ingrowth cores on August 8th and 9th, 2022 (2022-08-08 to 2022-08-09). The warming and elevated carbon dioxide (CO2) treatments in the dataset include the full treatment gradient: +0 degrees Celsius (C) (+0 and +500 parts per million (ppm) elevated CO2), +2.25 degrees C (+0 and +500 ppm), +4.5 degrees C (+0 and +500 ppm elevated CO2), +6.75 degrees C (+0 and +500 ppm) and +9 degrees C (+0 and +500 ppm elevated CO2) for both hummocks and hollows. This dataset includes measurements of the height and absolute coverage (%) for each vascular plant and moss species, as well as organic litter and dead overstory vascular plants, and the distance from the grid center to the nearest tree and the species of the nearest tree. These data were used as species-specific aboveground plant metadata for assessing the warming and elevated CO2 response of fine roots across different peatland microtopographical features (hummocks and hollows) and plant functional types (shrub, spruce and larch). This dataset contains one data file in comma separate (.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

RCT: Module 2.11, Radiological Work Coverage, Course 8777

Radiological work is usually approved and controlled by radiation protection personnel by using administrative and procedural controls, such as radiological work permits (RWPs). In addition, some jobs will require working in, or will have the potential for creating, very high radiation, contamination, or airborne radioactivity areas. Radiological control technicians (RCTs) providing job coverage have an integral role in controlling radiological hazards. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

61 RADIATION PROTECTION AND DOSIMETRY↗

RCT Continuing Training: RCT Job Coverage and CONOPS

RCT Continuing Training covering all of the necessary steps associated with RCT, and how conduct of operations ties in with this process. The terminal objective of this training is: Given the need to perform radiological job coverage, recognize the requirements to maintain radiological work control in accordance with P121, Radiation Protection, RP-PROG-TP-200, Radiation Protection Manual, and P315, Conduct of Operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

RCT Module 2.11 Radiological Work Coverage [Slides]

Given the need to perform duties as an RCT, identify the required and recommended practices in radiological work coverage in accordance with RP-PROG-TP-200, Radiation Protection Manual, and P121, Radiation Protection

61 RADIATION PROTECTION AND DOSIMETRY↗

2x2 Demonstrator High-Coverage Light Readout System in a Novel LArTPC

DUNE is a long-baseline Liquid Argon Time Projection Chamber (LArTPC) neutrino oscillation experiment. Its near detectors, located at Fermi National Laboratory, will constrain systematic errors on far detector measurements. The 2x2 Demonstrator, a novel proof of concept prototype for the ND LArTPC, has a modular TPC design that mitigates event pileup in a high-occupancy nearline beam environment, further aided by a native 3D pixelated charge readout and a 30% coverage, low profile light readout. This will be the first large-scale LArTPC to utilize pixels in place of wire planes

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ComStock Measure Documentation: Photovoltaics With 40% Rooftop Coverage

This study investigates the impact of adding 40% rooftop coverage of photovoltaics to the U.S. commercial building stock. Panels are modeled as higher performance with 21% rated efficiency, 96% inverter efficiency, 1.10 DC/AC ratio,14% system losses, and azimuth/tilt angles that vary by location. Total panel area is modeled at 40% of the roof area for each model. Total rated PV power for a building is based on the calculated total panel area and the assumed efficiency of 21%. This measure is applied to all buildings modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Demonstration of Optimal Benchmark Selection Website and Validation of the q c Coverage Metric Using HEU-SOL-THERM-013-003 Experiment

In the work documented in this interim report, the experiment selection toolkit web site was demonstrated and q C coverage metric methodology was validated for IEU-MET-FAST-002-001, MIX-COMP-THERM 004-004, and HEU-SOL-THERM-013-003 experiments. 𝑞 𝐶 is an information-theoretic measure based on mutual information that quantifies the ability of candidate benchmark experiments to reduce the bias and uncertainty of a target criticality safety application. The metric and an accompanying open-source Python toolkit with a web-based interface were tested against a benchmark set of 425 experiments drawn from the International Criticality Safety Benchmark Evaluation Project Handbook. The interface is hosted at https://edim.covdef.com. It accepts sensitivity data files produced by the TSUNAMI-IP module of the SCALE code system and supports both (i) deterministic analysis using the ENDF/B-VII.0 covariance library and (ii) stochastic analysis based on user-supplied keff samples. Demonstrations on representative applications across a range of material composition, spectrum, and form show that q C -guided benchmark selection achieves greater uncertainty reduction with fewer experiments and yields more stable posterior bias and uncertainty estimates than traditional similarity coefficient ( c k )–based selection, while also capturing valuable low-ck experiments that one-to-one metrics overlook.

Abdel-khalik, Hany S. [Indiana Univ.-Purdue Univ. ↗

Submission of Notice of Termination of Coverage Under the National Pollutant Discharge Elimination System General Permit No. CAS000002 for WDID No. 201C349114, Lawrence Livermore National Laboratory Ignition Facility Construction Project

This is the completed Notice of Termination of Coverage under the General Permit for Storm Water Discharges Associated with Construction Activity. Construction activities at the National Ignition Facility Construction Project at Lawrence Livermore National Laboratory are now complete. The Notice of Termination includes photographs of the completed construction project and a vicinity map.

54 ENVIRONMENTAL SCIENCES↗

SPRUCE S1 Bog Areal Coverage of Hummock and Hollow Microtopography Assessed Along Three Transects in the S1 Bog

Aerial coverage of hummocks and hollows was estimated in July 2012 in ten 4 m x 4 m plots each along three 60-m transects in the S1 Bog. Hollows were defined as the lowest elevation within plots and were typically at or near the height of the water table, hummocks included area above hollows, including the sides of the hummocks. The experimental work was conducted in a Picea mariana [black spruce] - Sphagnum spp. bog forest in northern Minnesota, 40 km north of Grand Rapids, in the USDA Forest Service Marcell Experimental Forest (MEF).

54 ENVIRONMENTAL SCIENCES↗

The Extended IRTF Spectral Library: Expanded Coverage in Metallicity, Temperature, and Surface Gravity

We present a 0.7–2.5 μm spectral library of 284 stars observed with the medium-resolution infrared spectrograph, SpeX, at the 3.0 m NASA Infrared Telescope Facility (IRTF) on Maunakea, Hawaii. This library extends the metallicity range of the IRTF Cool Star library beyond solar metallicity to −1.7 < [Fe/H] < 0.6. All of the observed stars are also in the MILES optical stellar library, providing continuous spectral coverage for each star from 0.35 to 2.5 μm. The spectra are absolute flux calibrated using Two Micron All Sky Survey photometry, and the continuum shape of the spectra is preserved during the data reduction process. Synthesized JHK {sub S} colors agree with observed colors at the 1%–2% level, on average. We also present a spectral interpolator that uses the library to create a data-driven model of spectra as a function of T{sub eff}, log g, and [Fe/H]. We use the library and interpolator to compare empirical trends with theoretical predictions of spectral feature behavior as a function of stellar parameters. These comparisons extend to the previously difficult to access low-metallicity and cool dwarf regimes, as well as the previously poorly sampled super-solar metallicity regime. The library and interpolator are publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗