Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

Onsite Energy Techno-Economic Analysis Using REopt

Since 2019, the National Renewable Energy Laboratory (NREL) has collaborated with IEDO's Combined Heat and Power (CHP) Deployment Program and the CHP Technical Assistance Partnerships (TAPs) to expand the capabilities of NREL's publicly available REopt® tool for techno-economic analysis of on-site energy. As a result, capabilities to analyze heating and cooling loads and serve those loads with CHP were added to the REopt tool in 2021. Currently, NREL is using REopt to evaluate the economics and feasibility of deploying distributed energy resources at sites of 3-5 manufacturers. The analysis is based on location, site-specific load data, customized utility bill analysis, and other criteria such as resilience needs and decarbonization targets. The objectives of the current effort are to (1) assist manufacturers with analyzing on-site energy options, including CHP, solar photovoltaics (PV), wind, and battery storage, (2) validate the capabilities and use of REopt to provide technical assistance to manufacturers, and (3) publish case studies showcasing the engagement, key takeaways, and lessons learned. Future work is expected to include additional REopt capabilities for evaluating other technologies to reduce scope 1 emissions, such as electrifying process heating loads, using carbon-free fuels, and other clean heat strategies.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Thermally Anisotropic Building Envelope Integration into Panelized Metal Construction: Laboratory Evaluation in Guarded Hot Box

The Thermally Anisotropic Building Envelope (TABE) is an active building envelope system that can exchange thermal energy with a storage medium to reduce the building’s energy demand. TABE redirects thermal energy along thin conductive layers in the building envelope to hydronic loops that are connected to thermal energy storage (TES), where it will be available to offset future energy demand when the conditions are favorable. TABEs can also be connected with a geothermal loop to reduce the building’s heating and cooling loads. Due to the importance of thermally conductive metal layers to TABE function, this technology has potential for easy adoption into panelized metal construction. In this study, we illustrate the construction process of prototype metal panels containing TABE and the laboratory evaluation in Oak Ridge National Laboratory’s rotatable guarded hot box. The thermal performance of the prototype panel was assessed for both baseline and operational cases and the total heat flow extracted from the panel by TABE was quantified.

Howard, Daniel↗

Decarbonization Dilemmas: Deliberating Difficult Decisions in Laboratory Design

Dive into the depths of design and decision-making, while we discuss the decarbonization of laboratory buildings! Delve into the dense domain of laboratory design and operations, where every development presents a diverse array of dilemmas and delights. Join us for these dynamic sessions focused on decoding the secrets of sustainable success. Dig deep into the dynamic world of heat pump designs and the delicate balance of heating and cooling loads. Debate between constant and variable fume hood designs, where these decisions determine outcomes. Discover the divergent paths of HVAC system implementation, from the deployment of chilled beams to the diverse array of different terminal unit types. But don't delay; decisive action is demanded for these goals! Dare to dream of decarbonization as we direct discussions on retrofitting existing building stock versus innovative new design approaches. Delve into the depths of debate and emerge with a decisive strategy for sustainable success. Discuss recent discoveries in development from experts associated with existing laboratory buildings with decarbonization goals. These insights and lessons learned will help determine the path forward in our industry's drive for decarbonization designs. Decarbonization is no easy task, but with determination, dedication, and devotion, we can defy the odds and forge a brighter future for laboratory design and operations. Let's dare to decarbonize together!

decarbonization↗

Advancing Mass Timber Buildings: Novel Methods Improve Thermal Assessment and Material Use

For nearly a century, thermal demand calculations for buildings have relied on simplified models developed to match the technical constraints of their era. The first standards, introduced in Germany and Austria in 1929, established climate zones and material conductivity coefficients that, with only incremental updates, still underpin many current assessments. Yet, methods such as Hot box testing, originally designed for lightweight insulation, continue to be applied for mass timber buildings, overlooking thermodynamic characteristics confer real-world advantages. Recent research at Oak Ridge National Laboratory incorporates updated methodologies, aligned with ASHRAE Standard 55 (ASHRAE, 2023) accounting for factors such as thermal inertia, inner surface temperatures, emissivity, solar gains, and dynamic outdoor conditions. These factors better reflect observed heating and cooling loads and highlight opportunities for efficient use of materials in mass timber construction. This work provides a framework for designing comfortable, resilient, and resource-efficient buildings while aligning with performance expectations in energy codes.

Pickett, Robert [International Mass Timber Allianc↗

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via coldstorage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulation-based assessment on stochastic load scheduling for building cooling systems

Here, to fill knowledge gaps related to stochastic load scheduling, we performed a comprehensive evaluation of the stochastic load scheduling for building cooling systems. Specifically, we studied the common uncertain variables in the load scheduling process for building cooling systems and categorized those variables based on their dynamic patterns. We then developed a generic stochastic load scheduling framework and applied it to building cooling systems that served a simulated community. This community consists of 100 heterogeneous houses and serves as a virtual testbed for evaluating the performance of stochastic load scheduling. In this evaluation, we considered representatives of uncertain variables with different dynamic patterns and included 100 realizations of the considered uncertainty in the evaluation to better catch the probability distribution of the control performance. The evaluation results suggest that deterministic load scheduling can reduce the operating energy cost by 18% but its performance can be affected by uncertainty. Stochastic load scheduling can further decrease the operating energy cost under uncertainty compared to deterministic load scheduling. We also found that the effectiveness of stochastic load scheduling in handling uncertainty is not directly associated with the number of uncertainty scenarios that are considered in its formulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JPL Energy Consumption Program (ECP) documentation: A computer model simulating heating, cooling and energy loads in buildings

The engineering manual provides a complete companion documentation about the structure of the main program and subroutines, the preparation of input data, the interpretation of output results, access and use of the program, and the detailed description of all the analytic, logical expressions and flow charts used in computations and program structure. A numerical example is provided and solved completely to show the sequence of computations followed. The program is carefully structured to reduce both user's time and costs without sacrificing accuracy. The user would expect a cost of CPU time of approximately $5.00 per building zone excluding printing costs. The accuracy, on the other hand, measured by deviation of simulated consumption from watt-hour meter readings, was found by many simulation tests not to exceed + or - 10 percent margin.

Lansing, F. L.↗

Low-Load Space Conditioning Needs Assessment

Heating, ventilating, and air-conditioning (HVAC) equipment must be right-sized to ensure energy performance and comfort. With limited low-load options in the HVAC market, many new-construction housing units are being fitted with oversized equipment that creates system efficiency, comfort, and cost penalties. To bridge the gap between currently available HVAC equipment that is oversized or inefficient and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family (duplex and townhouse) home market. Over the past decade, Steven Winter Associates, Inc. (SWA) has provided certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed these data to outline the characteristics of low-load dwellings such as the heating and cooling design loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

Bensadoun, Marc↗

Technology Solutions Case Study: Low-Load Space-Conditioning Needs Assessment

Low-load options in the heating, ventilating, and air-conditioning (HVAC) market are limited, so many new-construction housing units are being fitted with oversized equipment that results in penalties in system efficiency, comfort, and cost. To bridge the gap between currently available HVAC equipment and the rising demand for low-load HVAC equipment in the marketplace, HVAC equipment manufacturers need to be fully aware of the needs of the multifamily building and attached single-family home markets. Over the past decade, Steven Winter Associates, Inc. has provided certification and consulting services for hundreds of housing projects and has accrued a large pool of data that describe multifamily and attached single-family home characteristics. In this project, the research team Consortium for Advanced Residential Buildings (CARB) compiled and analyzed the data from 941 low-load buildings in the Northeast and Mid-Atlantic regions to outline the heating and cooling design load characteristics of low-load dwellings. Within this data set, CARB found that only 1% of the dwellings had right-sized (within 25% of design load) heating equipment and 6% had right-sized cooling equipment.

Air-source heat pumps↗