Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conditional thermal state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Prediction of the thermal environment and thermal response of simple panels exposed to radiant heat

A method of predicting the radiant heat flux distribution produced by a bank of tubular quartz heaters was applied to a radiant system consisting of a single unreflected lamp irradiating a flat metallic incident surface. In this manner, the method was experimentally verified for various radiant system parameter settings and used as a source of input for a finite element thermal analysis. Two finite element thermal analyses were applied to a thermal system consisting of a thin metallic panel exposed to radiant surface heating. A two-dimensional steady-state finite element thermal analysis algorithm, based on Galerkin's Method of Weighted Residuals (GFE), was formulated specifically for this problem and was used in comparison to the thermal analyzers of the Engineering Analysis Language (EAL). Both analyses allow conduction, convection, and radiation boundary conditions. Differences in the respective finite element formulation are discussed in terms of their accuracy and resulting comparison discrepancies. The thermal analyses are shown to perform well for the comparisons presented here with some important precautions about the various boundary condition models. A description of the experiment, corresponding analytical modeling, and resulting comparisons are presented.

Turner, Travis L.↗

Pressure Decay Testing Methodology for Quantifying Leak Rates of Full-Scale Docking System Seals

NASA is developing a new docking system to support future space exploration missions to low-Earth orbit and the Moon. This system, called the Low Impact Docking System, is a mechanism designed to connect the Orion Crew Exploration Vehicle to the International Space Station, the lunar lander (Altair), and other future Constellation Project vehicles. NASA Glenn Research Center is playing a key role in developing the main interface seal for this docking system. This seal will be relatively large with an outside diameter in the range of 54 to 58 in. (137 to 147 cm). As part of this effort, a new test apparatus has been designed, fabricated, and installed to measure leak rates of candidate full-scale seals under simulated thermal, vacuum, and engagement conditions. Using this test apparatus, a pressure decay testing and data processing methodology has been developed to quantify full-scale seal leak rates. Tests performed on untreated 54 in. diameter seals at room temperature in a fully compressed state resulted in leak rates lower than the requirement of less than 0.0025 lbm, air per day (0.0011 kg/day).

Dunlap, Patrick H., Jr.↗

Tribological Studies of Dynamic Thermal Seal Materials

Thermal seals are required on high-speed vehicles in many dynamic applications such as variable inlets in propulsion systems and control surfaces. These seals, often referred to as dynamic thermal seals, must not only mitigate inboard heat transfer, but must also exhibit sufficient durability when scrubbed against mating surfaces. For high-temperature high-speed vehicle applications, the mating surfaces are often made from thermal protection system (TPS) materials, which are typically rougher and more abrasive than TPS materials used at lower temperatures. The high-temperature TPS materials used can include non-ablative (e.g., lightweight porous oxides, ceramic matrix composites) andor ablative systems (e.g., phenolic systems). Due to the increased need for durable high-temperature dynamic seals, researchers working with the NASA Glenn Research Center embarked on an effort to (a) characterize the tribological performance of state-of-the-art thermal seal materials against a variety of TPS materials and (b) develop approaches for improved wear resistance. Tests were conducted using a recently upgraded high-temperature tribometer to assess wear resistance for a variety of tribopairs under multiple conditions. This data will begin to frame the challenges of using these materials and eventually permit an improved ability to design and implement these critical TPS components.

thermal protection↗

The Recovery of TOMS-EP

On December 13th 1998, the Total Ozone Mapping Spectrometer - Earth Probe (TOMS-EP) spacecraft experienced a Single Event Upset which caused the system to reconfigure and enter a Safe Mode. This incident occurred two and a half years after the launch of the spacecraft which was designed for a two year life. A combination of factors, including changes in component behavior due to age and extended use, very unfortunate initial conditions and the safe mode processing logic prevented the spacecraft from entering its nominal long term storage mode. The spacecraft remained in a high fuel consumption mode designed for temporary use. By the time the onboard fuel was exhausted, the spacecraft was Sun pointing in a high rate flat spin. Although the uncontrolled spacecraft was initially in a power and thermal safe orientation, it would not stay in this state indefinitely due to a slow precession of its momentum vector. A recovery team was immediately assembled to determine if there was time to develop a method of despinning the vehicle and return it to normal science data collection. A three stage plan was developed that used the onboard magnetic torque rods as actuators. The first stage was designed to reduce the high spin rate to within the linear range of the gyros. The second stage transitioned the spacecraft from sun pointing to orbit reference pointing. The final stage returned the spacecraft to normal science operation. The entire recovery scenario was simulated with a wide range of initial conditions to establish the expected behavior. The recovery sequence was started on December 28th 1998 and completed by December 31st. TOMS-EP was successfully returned to science operations by the beginning of 1999. This paper describes the TOMS-EP Safe Mode design and the factors which led to the spacecraft anomaly and loss of fuel. The recovery and simulation efforts are described. Flight data are presented which show the performance of the spacecraft during its return to science. Finally, lessons learned are presented.

Robertson, Brent↗

Two-component gravitating systems and the red giant-like structure

The present study investigates the equilibria and evolution of gravitating systems composed of two components by approximating their equations of states to polytropes. The structures are explored in hydrostatic equilibrium systematically under the condition that two components interact with each other only through gravity. The systems are found to be characterized by four parameters, the ratio of central densities and the ratio of central thermal energies per unit mass, and the polytropic indices of two components. If the central density is much higher, the structure is little affected by the presence of the other component. If the difference in the central thermal energies is smaller than specified by beta-cri, the system adopts an equilibrium configuration for any mass ratio. Two-component systems necessarily evolve to have the red giantlike structure if one component suffers cooling faster than the other. It is concluded that the red giant structure is a general characteristic of gravitating systems for which there is an appropriate mechanism to decouple the constituent into the hotter and cooler components.

Fujimoto, Masayuki Y.↗

International Space Station (ISS) Plasma Contactor Unit (PCU) Utilization Plan Assessment Update

The International Space Station (ISS) vehicle undergoes spacecraft charging as it interacts with Earth's ionosphere and magnetic field. The interaction can result in a large potential difference developing between the ISS metal chassis and the local ionosphere plasma environment. If an astronaut conducting extravehicular activities (EVA) is exposed to the potential difference, then a possible electrical shock hazard arises. The control of this hazard was addressed by a number of documents within the ISS Program (ISSP) including Catastrophic Safety Hazard for Astronauts on EVA (ISS-EVA-312-4A_revE). The safety hazard identified the risk for an astronaut to experience an electrical shock in the event an arc was generated on an extravehicular mobility unit (EMU) surface. A catastrophic safety hazard, by the ISS requirements, necessitates mitigation by a two-fault tolerant system of hazard controls. Traditionally, the plasma contactor units (PCUs) on the ISS have been used to limit the charging and serve as a "ground strap" between the ISS structure and the surrounding ionospheric plasma. In 2009, a previous NASA Engineering and Safety Center (NESC) team evaluated the PCU utilization plan (NESC Request #07-054-E) with the objective to assess whether leaving PCUs off during non-EVA time periods presented risk to the ISS through assembly completion. For this study, in situ measurements of ISS charging, covering the installation of three of the four photovoltaic arrays, and laboratory testing results provided key data to underpin the assessment. The conclusion stated, "there appears to be no significant risk of damage to critical equipment nor excessive ISS thermal coating damage as a result of eliminating PCU operations during non- EVA times." In 2013, the ISSP was presented with recommendations from Boeing Space Environments for the "Conditional" Marginalization of Plasma Hazard. These recommendations include a plan that would keep the PCUs off during EVAs when the space environment forecast input to the ISS charging model indicates floating potentials (FP) within specified limits. These recommendations were based on the persistence of conditions in the space environment due to the current low solar cycle and belief in the accuracy and completeness of the ISS charging model. Subsequently, a Noncompliance Report (NCR), ISS-NCR-232G, Lack of Two-fault Tolerance to EVA Crew Shock in the Low Earth Orbit Plasma Environment, was signed in September 2013 specifying new guidelines for the use of shock hazard controls based on a forecast of the space environment from ISS plasma measurements taken prior to the EVA [ISS-EVA-312-AC, 2012]. This NESC assessment re-evaluates EVA charging hazards through a process that is based on over 14 years of ISS operations, charging measurements, laboratory tests, EMU studies and modifications, and safety reports. The assessment seeks an objective review of the plasma charging hazards associated with EVA operations to determine if any of the present hazard controls can safely change the PCU utilization plan to allow more flexibility in ISS operations during EVA preparation and execution.

Hernandez-Pellerano, Amri↗

Boundary of the Slow Solar Wind

This work argues that there are two fundamental states of the non-transient solar wind, and that these can be distinguished by a number of criteria. Here we define the states, which will be termed slow and fast, or SSW and FSW, for lack of better terms, by the level of velocity fluctuations, v, in them, with the slow wind having systematically lower fluctuations than the fast wind. Almost all winds with speeds less than 450 km s1 are in the slow class, and winds with speeds greater than 600 km s1 are fast, but we argue that in between, consistent with other work, the v classification is more fundamental than speed. We show that the fluctuation categorization coincides well with classes based on Alfvénicy, proton specific entropy, ion thermal speed, and ionic composition. This correlated behavior among these solar wind parameters exists regardless of it being associated with a heliospheric current sheet or a pseudostreamer. This work provides evidence that both the so-called SSW I and SSW II scenarios coexist for the SSW formation. In addition, that the dynamical properties (thermal, magnetic, and turbulence properties) correlate well with properties set at the inner corona (ion ionization states and FIP bias)implies that there exists a boundary layer on the Sun within which the SSW is formed. This boundary layer would set up the coronal conditions for the source and transport of the SSW.

Ko, Yuan-Kuen↗

Thermal behavior spiral bevel gears

An experimental and analytical study of the thermal behavior of spiral bevel gears is presented. Experimental data were taken using thermocoupled test hardware and an infrared microscope. Many operational parameters were varied to investigate their effects on the thermal behavior. The data taken were also used to validate the boundary conditions applied to the analytical model. A finite element-based solution sequence was developed. The three-dimensional model was developed based on the manufacturing process for these gears. Contact between the meshing gears was found using tooth contact analysis to describe the location, curvatures, orientations, and surface velocities. This information was then used in a three-dimensional Hertzian contact analysis to predict contact ellipse size and maximum pressure. From these results, an estimate of the heat flux magnitude and the location on the finite element model was made. The finite element model used time-averaged boundary conditions to permit the solution to attain steady state in a computationally efficient manner.Then time- and position-varying boundary conditions were applied to the model to analyze the cyclic heating and cooling due to the gears meshing and transferring heat to the surroundings, respectively. The model was run in this mode until the temperature behavior stabilized. The transient flash temperature on the surface was therefore described. The analysis can be used to predict the overall expected thermal behavior of spiral bevel gears. The experimental and analytical results were compared for this study and also with a limited number of other studies. The experimental and analytical results attained in the current study were basically within 10% of each other for the cases compared. The experimental comparison was for bulk thermocouple locations and data taken with an infrared microscope. The results of a limited number of other studies were compared with those obtained herein and predicted the same basic behavior.

Handschuh, Robert F.↗

Measurements of the effects of thermal contact resistance on steady state heat transfer in phosphoric-acid fuel cell stack

The influence of the thermal contact resistance on the heat transfer between the electrode plates, and the cooling system plate in a phosphoric-acid fuel-cell stack was experimentally investigated. The investigation was conducted using a set-up that simulates the operating conditions prevailing in a phosphoric acid fuel-cell stack. The fuel-cell cooling system utilized three types of coolants, water, engine oil, and air, to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The thermal contact resistance was measured as a function of pressure at the interface between the electrode plate and the cooling system plate. The interface pressure range was from 0 kPa to 3448 kPa, while the Reynolds number for the cooling limits varied from 15 to 79 for oil, 1165 to 6165 for water, and 700 to 6864 for air. Results showed that increasing the interface pressure resulted in a higher heat transfer coefficient.

Abdul-Aziz, Ali↗

System for Testing Thermal Insulation of Pipes

An apparatus and method have been developed for measuring the rates of leakage of heat into pipes carrying liquids, the purpose of the measurements being to quantify the thermal performance of the insulation system. The apparatus is designed primarily for testing pipes used to carry cryogenic liquids, but can also be used for measuring the thermal performance of other insulated pipes or piping systems. The basic measurement principle is straightforward: The outer surface of the pipe insulation is maintained at a fixed warmer temperature. The interior of the pipe is maintained in a narrow fixed lower-temperature range by means of a regular liquid (e.g., water) that is pumped through the pipe at a known flow rate or a cryogenic liquid (e.g., nitrogen) that is saturated at atmospheric pressure and replenished until steady-state conditions are achieved. In the case of water or another liquid pumped through, the inlet and outlet temperatures are measured and heat-leak power is calculated as the mass flow rate of the liquid multiplied by the specific heat of the liquid multiplied by the inlet-to-outlet temperature rise of the liquid. In the case of liquid nitrogen or another low-temperature boiling liquid, the heat-leak power is calculated as the rate of boil-off multiplied by the latent heat of vaporization of the liquid. Then the thermal-insulation performance of the pipe system can be calculated as a function of the measured heat-leak power, the inner and outer boundary temperatures, and the dimensions of the pipe. The apparatus can test as many as three pipes simultaneously. The pipes can have inner diameters up to .15 cm and outer diameters up to .20 cm. The lengths of the pipes may vary; typical lengths are of the order of 18 m. Two thermal guard boxes . one for each end of the pipe(s) under test . are used to make the inlet and outlet fluid connections to the pipe(s) (see figure). The connections include bellows that accommodate thermal expansion and contraction of the pipes. The guard boxes and pipe(s) are positioned so that the pipe(s) slope upward from the upstream to the downstream end at an angle of at least 2 . The upward slope allows vapor bubbles to accumulate at the downstream end. The thermal guard boxes keep the ends of the pipes at the lower interior temperature to prevent spurious lengthwise leakage of heat into the pipes. It is important to prevent this spurious heat leakage because, if it were allowed to occur, it could contribute a large error in the measured heat-leak power. The upstream thermal guard box includes a heat exchanger through which liquid flowing into the pipe(s) is subcooled to the saturation temperature corresponding to the ambient pressure. Conversely, this heat exchanger can also be used to warm the flowing liquid to a desired fixed temperature. The apparatus includes a temperature control device that is placed around each pipe under test. Each device is operated under thermostatic control to maintain the outer surface of the pipe insulation at the specified test temperature. All measurements are recorded on a portable data-acquisition system.

Fesmire, James E.↗

Polar Lunar Regions: Exploiting Natural and Augmented Thermal Environments

In polar regions of the Moon, some areas within craters are permanently shadowed from solar illumination and can reach temperatures of 100 K or less. These regions could serve as cold traps, capturing ice and other volatile compounds. These potential ice stores have many applications for lunar exploration. Within double-shaded craters, even colder regions exist, with temperatures never exceeding 50 K in many cases. Observed temperatures suggest that these regions could enable equivalent liquid nitrogen cryogenic functions. These permanently shaded polar craters also offer unprecedented high-vacuum cryogenic environments, which in their current state could support cryogenic applications. Besides ice stores, the unique conditions at the lunar poles harbor an environment that provides an opportunity to reduce the power, weight, and total mass that needs to be carried from the Earth to the Moon for lunar exploration and research. Reducing the heat flux of geothermal, black body radiation can have significant impacts on the achievable temperature. With a few manmade augmentations, permanently shaded craters located near the lunar poles achieve temperatures even lower than those that naturally exist. Our analysis reveals that lightweight thermal shielding within shaded craters could create an environment several Kelvin above absolute zero. The temperature ranges of both naturally shaded and thermally augmented craters could enable the long-term storage of most gases, low-temperature superconductors for large magnetic fields, devices and advanced high-speed computing instruments. Augmenting thermal conditions in these craters could then be used as a basis for the development of an advanced thermal management architecture that would support a wide variety of cryogenically based applications. Lunar exploration and habitation capabilities would significantly benefit if permanently shaded craters, augmented with thermal shielding, were used to facilitate the operation of near absolute zero instruments, including a wide variety of cryogenically based propulsion, energy, communication, sensing, and computing devices. The required burden of carrying massive life-supporting components from the Earth to the Moon for lunar exploration and research potentially could be reduced.

Ryan, Robert E.↗

Melting relations in the iron-sulfur system at ultra-high pressures - Implications for the thermal state of the earth

The melting temperatures of FeS-troilite and of a 10-wt-pct sulfur iron alloy have been measured to pressures of 120 and 90 GPa, respectively. The results document that FeS melts at a temperature of 4100 (+ or - 300) K at the pressure of the core-mantle boundary. Eutecticlike behavior persists in the iron-sulfur system to the highest pressures of measurements, in marked contrast to the solid-solutionlike behavior observed at high pressures in the iron-iron oxide system. Iron with 10-wt-pct sulfur melts at a similar temperature as FeS at core-mantle boundary conditions. If the sole alloying elements of iron within the core are sulfur and oxygen and the outer core is entirely liquid, the minimum temperature at the top of the outer core is 4900 (+ or - 400) K. Calculations of mantle geotherms dictate that there must be a temperature increase of between 1000 and 2000 K across thermal boundary layers within the mantle. If D-double-prime is compositionally stratified, it could accommodate the bulk of this temperature jump.

Williams, Quentin↗

Stability of laser heated flows

A local stability analysis is utilized to determine the stability of disturbances generated at each point along a nozzle of variable area ratio for a one-dimensional flow heated by laser radiation entering from the upstream direction. The governing equations for the quasi-one-dimensional flow without viscous dissipation, diffusion, and thermal conduction but including radiative heat transfer are given. The governing equations are combined to yield a relationship which governs the Mach number variation through the nozzle. The complete steady-state solution can be calculated from knowledge of the Mach number profile, the inlet conditions, and the laser power. The local stability analysis permits obtaining contour (or contours) of neutral stability. Solutions have been obtained for various nozzle configurations, but only one set of example calculations is presented. The results obtained indicate that the analysis serves as an important indicator as to where potential absorption wave phenomena may be initiated.

Wu, P. K. S.↗

Doppler Lidar System Design via Interdisciplinary Design Concept at NASA Langley Research Center - Part II

Optimized designs of the Navigation Doppler Lidar (NDL) instrument for Autonomous Landing Hazard Avoidance Technology (ALHAT) were accomplished via Interdisciplinary Design Concept (IDEC) at NASA Langley Research Center during the summer of 2013. Three branches in the Engineering Directorate and three students were involved in this joint task through the NASA Langley Aerospace Research Summer Scholars (LARSS) Program. The Laser Remote Sensing Branch (LRSB), Mechanical Systems Branch (MSB), and Structural and Thermal Systems Branch (STSB) were engaged to achieve optimal designs through iterative and interactive collaborative design processes. A preliminary design iteration was able to reduce the power consumption, mass, and footprint by removing redundant components and replacing inefficient components with more efficient ones. A second design iteration reduced volume and mass by replacing bulky components with excessive performance with smaller components custom-designed for the power system. Thermal modeling software was used to run steady state thermal analyses, which were used to both validate the designs and recommend further changes. Analyses were run on each redesign, as well as the original system. Thermal Desktop was used to run trade studies to account for uncertainty and assumptions about fan performance and boundary conditions. The studies suggested that, even if the assumptions were significantly wrong, the redesigned systems would remain within operating temperature limits.

Crasner, Aaron I.↗

Process Modeling of Woven Textiles

Woven polymer matrix composites offer numerous advantages over traditional unidirectional laminates. Processing conditions affect residual stress that builds up during manufacturing. This work proposes the analysis of three curing parameters on the local residual stress distribution of a plain weave textile architecture, including chemical shrinkage, the temperature cool down, and the evolution of matrix properties as a function of curing. Virtual curing is applied to the inter-tow matrix material of the plain weave Repeating Unit Cell (RUC) modeled in TexGen. Curing is implemented through user-written subroutines within the commercial software suite Abaqus. Results from process modeling are compared with a linear-elastic thermal cool down in Abaqus. A boundary conditions study is also conducted to compare the residual stress build up predicted by Flat(FBCs) and Periodic Boundary Conditions (PBCs). Preliminary results indicate that a thermal cool down over-estimates the end-of-cure stresses in the matrix. Process modeling is conducted with and without chemical shrinkage, then compared with a thermal cool down. Results show that 11.32% of the final stress state is due to chemical shrinkage. Material property evolution during curing also has a non-negligible effect on the end stress.

woven composites↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

Cryogenic Propellant Transfer↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Hydrogen

Developing accurate models of two-phase cryogenic flow will reduce risk and reduce margins for future NASA vehicles such as the Nuclear Thermal Propulsion (NTP) system. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling and two-phase phenomena. The focus of the current work is on modeling steady state cryogenic flow boiling in the transfer line that connects a propellant storage tank to an engine or customer receiver tank. This paper presents Thermal Desktop model validation results against several historical liquid hydrogen (LH2) heated tube experiments that cover a wide range of inlet conditions, mass flux, and heat flux. New universal cryogenic flow boiling correlations were recently developed and anchored to the largest cryogenic flow boiling database assembled in the world to-date. The new universal correlations are patched together and implemented into Thermal Desktop to compare model performance against the built-in flow boiling correlations. Axial wall temperature predictions as a function of preponderant parameters like heat flux, mass flux, inlet pressure, inlet quality, tube diameter, etc. using the two sets of flow boiling correlations are compared against the experimental data. Overall, the Thermal Desktop model with the new universal cryogenic flow boiling correlations demonstrates an improvement in predictive performance over the Thermal Desktop model using built-in correlations for both wall temperature and location of critical heat flux compared to the data for LH2 flow boiling in heated tubes.

cryogenic propellant transfer↗

Thermoelectric Converter for Loop Heat Pipe Temperature Control: Experience and Lessons Learned

This paper describes the theoretical background and implementation methodology of using a thermoelectric converter (TEC) for operating temperature control of a loop heat pipe (LHP). In particular, experimental results from ambient and thermal vacuum tests of an LHP are presented for illustrations. The most commonly used state-of-the-art method to control the LHP operating temperature is to cold bias its compensation chamber (CC) and use an electrical heater to maintain the CC at the desired set point temperature. Although effective, this approach has its shortcomings in that the electrical heater can only provide heating to the CC, and the required power can be large under certain conditions. An alternative method is to use a TEC, which is capable of providing both heating and cooling to the CC. In this method, one side of the TEC is attached to the CC, and the other side is connected to the evaporator via a thermal strap. Using a bipolar power supply and a control algorithm, a TEC can function as a heater or a cooler, depending on the direction of the current flow. Extensive ground tests of several LHPs have demonstrated that a TEC can provide very tight temperature control for the CC. It also offers several additional advantages: (1) The LHP can operate at temperatures below its natural operating temperature at low heat loads; (2) The required heater power for a TEC is much less than that for an electrical heater; and (3) It enhances the LHP start-up success. Although the concept of using a TEC for LHP temperature control is simple, there are many factors to be considered in its implementation for space applications because the TEC is susceptible to the shear stress and yet has to sustain the dynamic load under the spacecraft launch environment. The added features that help the TEC to withstand the dynamic load will inevitably affect the TEC thermal performance. Some experiences and lessons learned are addressed in this paper.

Ku, Jentung↗