Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Girsanov's transformation based variance reduced Monte Carlo simulation schemes for reliability estimation in nonlinear stochastic dynamics

The study considers the problem of simulation based time variant reliability analysis of nonlinear randomly excited dynamical systems. Attention is focused on importance sampling strategies based on the application of Girsanov's transformation method. Controls which minimize the distance function, as in the first order reliability method (FORM), are shown to minimize a bound on the sampling variance of the estimator for the probability of failure. Two schemes based on the application of calculus of variations for selecting control signals are proposed: the first obtains the control force as the solution of a two-point nonlinear boundary value problem, and, the second explores the application of the Volterra series in characterizing the controls. The relative merits of these schemes, vis-à-vis the method based on ideas from the FORM, are discussed. Illustrative examples, involving archetypal single degree of freedom (dof) nonlinear oscillators, and a multi-degree of freedom nonlinear dynamical system, are presented. The credentials of the proposed procedures are established by comparing the solutions with pertinent results from direct Monte Carlo simulations. - Highlights: • The distance minimizing control forces minimize a bound on the sampling variance. • Establishing Girsanov controls via solution of a two-point boundary value problem. • Girsanov controls via Volterra's series representation for the transfer functions.

97 MATHEMATICS AND COMPUTING↗

GRAPhEME: a setup to measure (n, xn γ) reaction cross sections

Most of nuclear reactor developments are using evaluated data base for numerical simulations. However, the considered databases present still large uncertainties and disagreements. To improve their level of precision, new measurements are needed, in particular for (n, xn) reactions, which are of great importance as they modify the neutron spectrum, the neutron population, and produce radioactive species. The IPHC group started an experimental program to measure (n, xn gamma) reaction cross sections using prompt gamma spectroscopy and neutron energy determination by time of flight. Measurements of (n, xn gamma) cross section have been performed for {sup 235,238}U, {sup 232}Th, {sup nat,182,183,184,186}W, {sup nat}Zr. The experimental setup is installed at the neutron beam at GELINA (Geel, Belgium). The setup has recently been upgraded with the addition of a highly segmented 36 pixels planar HPGe detector. Significant efforts have been made to reduce radiation background and electromagnetic perturbations. The setup is equipped with a high rate digital acquisition system. The analysis of the segmented detector data requires a specific procedure to account for cross signals between pixels. An overall attention is paid to the precision of the measurement. The setup characteristic and the analysis procedure will be presented along with the acquisition and analysis challenges. Examples of results and their impact on models will be discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergency Renal Ablation for Life-Threatening Hemorrhage from Multiple Capsular Branches During Renal Artery Stenting

A 55-year-old woman underwent bilateral renal artery stent placement with good angiographic result. After the procedure, the patient complained of left flank pain secondary to subcapsular hematoma. Retrospective evaluation of images taken during stent implantation favored the diagnosis of guidewire perforation. Three hours after the procedure, contrast-enhanced computed tomography and subsequent renal angiography showed multifocal extravasations. We performed emergent renal ablation for the treatment of massive bleeding. To our knowledge, this is the first use of transcatheter renal ablation technique for this purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation for Iron Calorimeter prototype detector of India-based Neutrino Observatory

The India-based Neutrino Observatory (INO) collaboration is proposing to build a 50 kton magnetized iron calorimeter (ICAL) detector in an underground laboratory to be located in South India. As a first step towards building the ICAL detector, a 35 ton prototype of the same design has been set up on the surface to track cosmic ray muons. This paper discusses the prototype detector geometry simulation by GEANT4, and the detector response to the cosmic muons. We have developed a track fitting procedure based on the Kalman Filter technique for the prototype detector when the detector is exposed to single muon tracks. The relevant track parameters i.e., momentum, direction and charge are reconstructed and analyzed. Finally we show the resolution of reconstructed momenta.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the quality index (Q) for photon beams at arbitrary field sizes

Purpose: A commonly used beam quality index (Q) for high-energy photon beams is the tissue phantom ratio (TPR{sub 20,10}) for a square field of 10x10 cm{sup 2} and SDD of 100 cm. On some specialized radiotherapy treatment equipment such a reference collimator setting is not achievable. Likewise a flat beam profile, not explicitly required in dosimetry protocols, but certainly influences the measurement of Q, is not always produced. In this work, a method was developed in order to determine Q at any field size, especially for small and nonflattened beams. Methods: An analytical relationship was derived between TPR{sub 20,10} for arbitrary field sizes and Q[the TPR{sub 20,10}(10x10 cm{sup 2})] as quality index. The proposed model equation was fitted to the measured and published data in order to achieve three general fit parameters. The procedure was then tested with published data from TomoTherapy and CyperKnife treatment devices. Results: For standard flattened photon fields, the uncertainty in Q measured at any field size using the parameters derived from this study is better than 1%. In flattening-filter free beams, the proposed procedure results in a reliable Q for any field size setting. Conclusions: A method is introduced and successfully tested in order to measure the beam quality under nonstandard conditions. It can be used, e.g., to get energy dependent correction factors as tabulated in dosimetry codes of practice even if standard conditions are not adjustable.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-167: Use of MR for Permanent Prostate Implant Preplanning

Purpose: To study the feasibility using MR imaging to improve target definition on ultrasound during permanent prostate implants and aid in source strength determination for treatment planning in the OR. Methods: Patients who receive permanent prostate implants undergo MR and CT imaging prior to the implant procedure to determine the volume of the prostate, bony restriction to the procedure, bladder extension, external sphincter length and neurovascular bundle. The volume of the prostate is generally used to order seeds for the procedure. In 10 patients, the MR was used as the preplanning study with the PTV defined as a 2 mm expansion of the MR prostate in all directions except the posterior. Various dose volume parameters for the MR prostate and the PTV were compared to the actual preplan developed and executed in the OR. In addition, there parameters were compared to the post implant dosimetry performed 3 weeks after the implant procedure. Results: The results show that the number of seeds used using MR and US (ultrasound) planning was generally with 2 seeds and the maximum difference was 7 seeds. There is no significant difference between any of the dose index parameters of V100, V150, V200, D99 and D90 parameters between MR planning, US planning and postimplant evaluation There was a significant difference between planned D99 (avg of 105%) and achieved D99 (avg 91%). Conclusion: MR imaging is an invaluable tool to improve target definition for permanent prostate implants. Use of MR images for preplanning improves the confidence with which source can be ordered for the procedure that is OR planned. Ordering a maximum of 10 seeds more than planned would be sufficient to deliver a plan in the OR using US. Moving ahead to non-rigid registration between MR ad US images could further increase the confidence level of MR planning.

60 APPLIED LIFE SCIENCES↗

Long-term Spot Stability in the Post-common-envelope Binary QS Vir

We observed the post-common-envelope eclipsing binary with a white dwarf component, QS Vir, using the 1.88 m telescope of Kotammia Observatory in Egypt. The new observations were analyzed together with all multicolor light curves available online (sampling a period of 25 yr), using a full-feature binary system modeling software based on Roche geometry. This is the first time complete photometric modeling was done with most of these data. QS Vir is a detached system, with the red dwarf component underfilling its Roche lobe by a small margin. All light curves feature out-of-eclipse variability that is associated with ellipsoidal variation, mutual irradiation and irregularities in surface brightness of the tidally distorted and magnetically active red dwarf. We tested models with one, two, and three dark spots and found that one spot is sufficient to account for the light curve asymmetry in all data sets, although this does not rule out the presence of multiple spots. We also found that a single spotted model cannot fit light curves observed simultaneously in different filters. Instead, each filter requires a different spot configuration. To thoroughly explore the parameter space of spot locations, we devised a grid-search procedure and used it to find consistent solutions. Based on this, we conclude that the dark spot responsible for light curve distortions has been stable for the past 15 yr, after a major migration that happened between 1993 and 2002, possibly due to a flip-flop event.

79 ASTRONOMY AND ASTROPHYSICS↗

Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unidirectional wireless power transfer using near-field plates

One of the obstacles preventing wireless power transfer from becoming ubiquitous is their leakage of power: high-amplitude electromagnetic fields that can interfere with other electronic devices, increase health concerns, or hinder power metering. In this paper, we present near-field plates (NFPs) as a novel method to tailor the electromagnetic fields generated by a wireless power transfer system while maintaining high efficiency. NFPs are modulated arrays or surfaces designed to form prescribed near-field patterns. The NFP proposed in this paper consists of an array of loaded loops that are designed to confine the electromagnetic fields of a resonant transmitting loop to the desired direction (receiving loop) while suppressing fields in other directions. The step-by-step design procedure for this device is outlined. Two NFPs are designed and examined in full-wave simulation. Their performance is shown to be in close agreement with the design predictions, thereby verifying the proposed design and operation. A NFP is also fabricated and experimentally shown to form a unidirectional wireless power transfer link with high efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transverse mode revival of a light-compensated quantum memory

A long-lived quantum memory was developed based on light-compensated cold {sup 87}Rb atoms in a dipole trap. The lifetime of the quantum memory was improved by 40 folds, from 0.67 to 28 ms with the help of a compensation laser beam. Oscillations of the memory efficiency due to the transverse mode breathing of the singly excited spin wave have been clearly observed and clarified with a Monte Carlo simulation procedure. With detailed analysis of the decoherence processes of the spin wave in cold atomic ensembles, this experiment provides a benchmark for the further development of high-quality quantum memories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery

Purpose: The optically guided target localization had been developed for linear accelerator based stereotactic radiosurgery (SRS). Unlike the traditional laser localization, the optical guided target localization utilizes a digital system to position patient. Although the system has been proven accurate and robust, it takes away the capability of physicist to directly double check the target position prior to irradiation. Any error from system calibration, data transformation, or head ring position maintenance will not be caught. The purpose of this work is to investigate the possibility of using cone-beam CT (CBCT) to double check the optically guided SRS target localization and reposition the patient. Methods: A SRS quality assurance (QA) phantom was used in the study. The phantom mounted with SRS head frame was scanned by computer tomography (CT) and planned according to the SRS radiation treatment planning process. A target isocenter is defined and transferred to the optically guided target localization system. The phantom was then transported to the linear accelerator room and localized at the initial position agreed by the optically guided target localization system and the CBCT system. Tests were conducted by moving/rotating the phantom to a set of preset offsets and taking CBCT images. Shifts detected by CBCT were compared with the preset offsets. Agreements between them were studied to see how well the CBCT was in discovering the optically guided target localization error. Results: Experiment results demonstrated good agreement between the CBCT detected phantom shift and the preset offset, when the offset is above 1 mm shift or 0.2 degree rotation. Offset less than 1 mm shift or 0.2 degree rotation was not detectable by CBCT. Conclusions: The study concludes that the CBCT is able to discover the optically guided target localization error due to the system calibration or had ring migration. It is a valuable second check tool for SRS target localization quality assurance. The accuracy of CBCT in estimating patient positioning deviation satisfies the SRS procedures with generous tumor size and margin that can tolerate 1 mm or 0.2 degree accuracy. This avoids sending patient home without treatment. CBCT can be neither used as a primary SRS target localization nor can it be used to reposition the patient that cannot tolerate 1 mm shift or 0.2 degree rotation.

60 APPLIED LIFE SCIENCES↗

Analysis of biological tissues in infant chest for the development of an equivalent radiographic phantom

Purpose: The main purpose of the present study was to determine the amounts of different tissues in the chest of the newborn patient (age {<=}1 year), with the aim of developing a homogeneous phantom chest equivalent. This type of phantom is indispensable in the development of optimization procedures for radiographic techniques, including dosimetric control, which is a crucial aspect of pediatric radiology. The authors present a systematic set of procedures, including a computational algorithm, to estimate the amounts of tissues and thicknesses of the corresponding simulator material plates used to construct the phantom. Methods: The Gaussian fit of computed tomographic (CT) analysis was applied to classify and quantify different biological tissues. The methodology is summarized with a computational algorithm, which was used to quantify tissues through automated CT analysis. The thicknesses of the equivalent homogeneous simulator material plates were determined to construct the phantom. Results: A total of 180 retrospective CT examinations with anterior-posterior diameter values ranging 8.5-13.0 cm were examined. The amounts of different tissues were evaluated. The results provided elements to construct a phantom to simulate the infant chest in the posterior-anterior or anterior-posterior (PA/AP) view. Conclusions: To our knowledge, this report represents the first demonstration of an infant chest phantom dedicated to the radiology of children younger than one year. This phantom is a key element in the development of clinical charts for optimizing radiographic technique in pediatric patients. Optimization procedures for nonstandard patients were reported previously [Pina et al., Phys. Med. Biol. 49, N215-N226 (2004) and Pina et al., Appl. Radiat. Isot. 67, 61-69 (2009)]. The constructed phantom represents a starting point to obtain radiologic protocols for the infant patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-216: A Sequence Independent Approach for Quantification of MR Image Deformations From Brachytherapy Applicators

Purpose: MRI is increasingly used as a single imaging modality for brachytherapy treatment planning. The presence of a brachytherapy applicator may cause distortions in the images, especially at higher field strengths. Our aim is to develop a procedure to quantify these distortions theoretically for any MR-sequence and to verify the estimated deformations for clinical sequences. Methods: Image distortions due to perturbation of the B0-field are proportional to the ratio of the induced frequency shift and the read-out bandwidth of the applied sequence. By reconstructing a frequency-shift map from the phase data from a multi-echo sequence, distortions can be calculated for any MR-sequence. Verification of this method for estimating distortions was performed by acquiring images with opposing read-out directions and consequently opposing distortions. The applicator shift can be determined by rigidly matching these images. Clinically, T2W-TSE-images are used for this purpose. For pre-clinical tests, EPI-sequences with narrow read-out bandwidth (19.5–47.5Hz), consequently large distortions, were added to the set of clinical MRsequences. To quantify deformations of the Utrecht Interstitial CT/MR applicator (Elekta Brachytherapy) on a Philips Ingenia 3T MRI, pre-clinical tests were performed in a phantom with the applicator in water, followed by clinical validation. Results: Deformations observed in the narrow bandwidth EPI-images were well predicted using the frequency-shift, the latter giving an overestimation up to 30%/up to 1 voxel. For clinically applied MR-sequences distortions were well below the voxel size. In patient setup distortions determined from the frequency-shift map were at sub-voxel level (<0.7mm). Using T2W-images larger distortions were found (1–2mm). This discrepancy was caused by patient movement between/during acquisition of the T2W-images with opposing read-out directions. Conclusion: Phantom experiments demonstrated the feasibility of a clinical procedure for quantification of MR-image distortions for any MR-sequence. In a clinical set-up the distortions from a Utrecht interstitial CT/MR applicator are sub-voxel level. This work was partially funded by Elekta Brachytherpy.

60 APPLIED LIFE SCIENCES↗

Modeling quasi-lattice with octagonal symmetry

We prove the possibility to use the method of modeling of a quasi-lattice with octagonal symmetry similar to that proposed earlier for the decagonal quasicrystal. The method is based on the multiplication of the groups of basis sites according to specified rules. This model is shown to be equivalent to the method of the periodic lattice projection, but is simpler because it considers merely two-dimensional site groups. The application of the proposed modeling procedure to the reciprocal lattice of octagonal quasicrystals shows a fairly good matching with the electron diffraction pattern. Similarly to the decagonal quasicrystals, the possibility of three-index labeling of the diffraction reflections is exhibited in this case. Moreover, the ascertained ratio of indices provides information on the intensity of diffraction reflections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Treatment Process for Radioactive Wastewater Generated from Molybdenum-99 Study - 16415

Molybdenum-99 (Mo-99) high acidic waste solution was securely stored at INER for numerous years. Until 2004, the procedures of waste solution draw-out and pressure-release were accompanied, along with construction of treatment facilities. In 2009, after simulated solution and small volume Mo-99 waste solution tests, the treatment procedure was determined. Then batch-scale treatment facilities were set up. The waste solution was preserved using the instrument, along with modification of some facilities simultaneously. Ultimately all of 12 tanks of Mo-99 inorganic waste solution stored in Building 014 were finished on July, 2012. And residential 5 tanks of those solution served in Building 015B were also completed on September, 2014. A practicable process has been developed for treating radioactive waste generated from Mo-99 study, and it can effectively remove radionuclides from a nitric acid solution. At first, after the waste was sucked from the bucket, the pH value was adjusted to about 10.0 through acid-alkali neutralization. Then, an adsorbent of natural zeolite powder was added to adsorb nuclides, and two adsorption columns filled with Cs-treat and Sr-treat adsorbents were used for removing nuclear species of Cs-137 and Sr-90. In this step, the nuclear species of Cs-137 and Sr-90 contained in the liquid waste are significantly reduced to a degree for manual operation allowable. Then, nitrate ion and mercury ion were removed through another procedure. As a result, the operations were safer and more efficient than other conventional methods. Additionally, the hazard of accidental leakage caused by corrosion of the bucket after long period of storage can be effectively prevented and potential pollution threats are also eliminated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a core coolant flow distribution calculation code for HTGRs - 18484

In order to ensure the thermal integrity of fuel in high temperature gas-cooled reactors (HTGRs), it is necessary that the maximum fuel temperature in the normal operation is to be lower than the thermal design target. In the core thermal-hydraulic design of block-type HTGRs, the maximum fuel temperature should be evaluated considering data such as thermal power, core geometry, power and neutron fluence distributions, and core coolant flow distribution. The core coolant flow distribution calculation code used in the design stage of High Temperature engineering Test Reactor (HTTR) presupposes to run on UNIX systems, and its operation and execution procedure are complicated and not user-friendly. Therefore, a new core coolant flow distribution calculation code with a user-friendly system such as simple and easy operations and execution procedures has been developed. In this paper, the outline of the new code is described and the simulation result of an out-of-pile test with one fuel column are shown as the first step of the code validation. The simulation results provide good agreement with the test one. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗