Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Three-dimensional strain imaging of irradiated chromium using multi-reflection Bragg coherent diffraction

Abstract Radiation-induced materials degradation is a key concern in limiting the performance of nuclear materials. The formation of nanoscale void and gas bubble superlattices in metals and alloys under radiation environments can effectively mitigate radiation-induced damage, such as swelling and aid the development of next generation radiation tolerant materials. To effectively manage radiation-induced damage via superlattice formation, it is critical to understand the microstructural changes and strain induced by such superlattices. We utilize multi-reflection Bragg coherent diffraction imaging to quantify the full strain tensor induced by void superlattices in iron irradiated chromium substrate. Our approach provides a quantitative estimation of radiation-induced three-dimensional (3D) strain generated at the microscopic level and predicts the number density of defects with a high degree of sensitivity. Such quantitative evaluation of 3D strain in nuclear materials can have a major impact on predicting materials behavior in radiation environments and can revolutionize design of radiation tolerant materials.

36 MATERIALS SCIENCE↗

Atomistic three-dimensional coherent x-ray imaging of nonbiological systems

We computationally study the resolution limits for three-dimensional coherent x-ray diffractive imaging of heavy, nonbiological systems using Ar clusters as a prototype. We treat electronic and nuclear dynamics on an equal footing and remove the frozen-lattice approximation often used in electronic damage studies. We explore the achievable resolution as a function of pulse parameters (fluence level, pulse duration, and photon energy) and particle size. The contribution of combined lattice and electron dynamics is not negligible even for 2 fs pulses, and the Compton scattering is less deleterious than in biological systems for atomic-scale imaging. Although free-electron scattering represents a significant background, we find that recovery of the original structure is in principle possible with 3 angstrom resolution for particles of 11 nm diameter.

47 OTHER INSTRUMENTATION↗

Coherent-Pulse 2D Crystallography Using a Free-Electron Laser X-Ray Source

Coherent diffractive imaging for the reconstruction of a two-dimensional (2D) finite crystal structure with a single pulse train of free-electron laser radiation at 7.97 nm wavelength is demonstrated. This measurement shows an advance on traditional coherent imaging techniques by applying it to a periodic structure. It is also significant that this approach paves the way for the imaging of the class of specimens which readily form 2D, but not three-dimensional crystals. We show that the structure is reconstructed to the detected resolution, given an adequate signal-to-noise ratio.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent X-ray Diffraction Imaging of Zeolite Microcrystals

We measured coherent x-ray diffraction (CXD), an emerging technique to obtain three-dimensional internal and external images of crystals, on ZSM-5 zeolite microcrystals to get internal density distribution and to map deformation field of strain. The experiments were performed at the beamline 34-ID-C in Advanced Photon Source at Argonne National Laboratory in the US. The CXD patterns of ZSM-5 zeolite microcrystals with sizes of 2 {mu}m by monochromatic coherent x-rays with energy of 9 keV were obtained under continuously surrounding and Bragg conditions as a function of temperature. The oversampled diffraction patterns are inverted to obtain three-dimensional images of the shapes and internal strain fields of zeolite microcrystals using phase retrieval algorithms of error reduction and a hybrid input-output method. The internal density and strain distribution as a function of temperature are discussed.

36 MATERIALS SCIENCE↗

The linac coherent light source single particle imaging road map

Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast imaging of transients and coherent magnetohydrodynamic modes in DIII-D

A fast framing camera is used to image plasma waves and instabilities in the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] in unprecedented detail including tearing modes (TMs) and sawtooth crashes. To image core magnetohydrodynamic (MHD) activity, the fast camera detects visible bremsstrahlung emission {epsilon}{sub B} in moderate to high density plasmas. For coherent MHD activity such as TMs, high-resolution two-dimensional images of mode amplitude and phase are obtained by Fourier filtering each pixel's time series at the mode frequency. Images of m/n=2/1 TMs show that inside the q=2 surface, the camera measurements are in excellent agreement with an analytic model of a 2/1 island superimposed on the equilibrium {epsilon}{sub B} profile. Direct comparison of the measurements to a NIMROD simulation shows significant discrepancies, most likely due to artificially high-density diffusion used in the code for numerical stability. The first visible-light images of transient sawtooth crashes show the structure and location of the perturbed emission from an m=1 precursor oscillation and show that during the nonlinear crash phase the instability extends to more than half of the plasma minor radius.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep-Learning Electron Diffractive Imaging

Here, we report the development of deep-learning coherent electron diffractive imaging at subangstrom resolution using convolutional neural networks (CNNs) trained with only simulated data. We experimentally demonstrate this method by applying the trained CNNs to recover the phase images from electron diffraction patterns of twisted hexagonal boron nitride, monolayer graphene, and a gold nanoparticle with comparable quality to those reconstructed by a conventional ptychographic algorithm. Fourier ring correlation between the CNN and ptychographic images indicates the achievement of a resolution in the range of 0.70 and 0.55 Å. We further develop CNNs to recover the probe function from the experimental data. The ability to replace iterative algorithms with CNNs and perform real-time atomic imaging from coherent diffraction patterns is expected to find applications in the physical and biological sciences.

47 OTHER INSTRUMENTATION↗

Coherent X-ray diffractive imaging of protein crystals

The technique of coherent X-ray diffraction imaging (CXDI) has recently shown great promise for the study of inorganic nanocrystals. In this work the CXDI method has been applied to the study of micrometer-size protein crystals. Finely sampled diffraction patterns of single crystals were measured and iterative phase-retrieval algorithms were used to reconstruct the two-dimensional shape of the crystal. The density maps have limited reproducibility because of radiation damage, but show clear evidence for crystal facets. Qualitative analysis of a number of single-crystal diffraction peaks indicates the presence of inward surface contraction on 2 {micro}m size crystals. A survey of several hundred diffraction patterns yielded a number of examples with dramatic single-sided streaks, for which a plausible model is constructed.

59 BASIC BIOLOGICAL SCIENCES↗

Lensless x-ray imaging in reflection geometry

Lensless X-ray imaging techniques such as coherent diffraction imaging and ptychography, and Fourier transform holography can provide time-resolved, diffraction-limited images. Nearly all examples of these techniques have focused on transmission geometry, restricting the samples and reciprocal spaces that can be investigated. We report a lensless X-ray technique developed for imaging in Bragg and small-angle scattering geometries, which may also find application in transmission geometries. We demonstrate this by imaging a nanofabricated pseudorandom binary structure in small-angle reflection geometry. The technique can be used with extended objects, places no restriction on sample size, and requires no additional sample masking. The realization of X-ray lensless imaging in reflection geometry opens up the possibility of single-shot imaging of surfaces in thin films, buried interfaces in magnetic multilayers, organic photovoltaic and field-effect transistor devices, or Bragg planes in a single crystal.

36 MATERIALS SCIENCE↗

A sensitive infrared imaging up converter and spatial coherence of atmospheric propagation

An infrared imaging technique based on the nonlinear interaction known as upconversion was used to obtain images of several astronomical objects in the 10 micrometer spectral region, and to demonstrate quantitatively the sharper images allowed for wavelengths beyond the visible region. The deleterious effects of atmospheric inhomogeneities on telescope resolution were studied in the infrared region using the technique developed. The low quantum efficiency of the device employed severely limited its usefulness as an astronomical detector.

Boyd, R. W.↗

Coherent Optical Transition Radiation Imaging for Laser-Driven Plasma Accelerator Electron-Beam Diagnostics

Application of coherent optical transition radiation (COTR) diagnostics to compact accelerators has been demonstrated for the laser-driven wake field accelerator (LWFA) case recently. It is proposed that such diagnostics for beam size, beam divergence, microbunching fraction, spectral content, and bunch length would be useful before and after any subsequent acceleration in crystals or nanostructures. In addition, there are indications that under some scenarios a microbunched beam could resonantly excite wake fields in nanostructures that might lead to an increased acceleration gradient.

43 PARTICLE ACCELERATORS↗

2022 AI Testbed Expeditions Report

By exploiting the coherent properties of a light source, coherent diffraction imaging (CDI) is able to obtain the sample image at a nanoscale resolution using the measured diffraction pattern. Bragg Coherent Diffraction Imaging (BCDI) has become valuable for recovering the displacement and strain field of crystals, providing a valuable tool in material science and solid-state physics. X-ray ptychography is another emerging CDI technique that can produce a high-resolution image of the extended sample and has become popular in many research areas (e.g., materials science, biology, electronics, and optics characterization). CDI including BCDI and ptychography has become an established technique in Synchrotron Facilities including the Advanced Photon Source (APS) and will greatly benefit from the 100x coherent flux increase of the upcoming APS Upgrade (APSU). The current image formation process in CDI employs iterative phase retrieval algorithms, which is a time-consuming and computationally expensive process. Especially after APSU, the traditional iterative methods will not be able to match the experimental data acquisition speed. We employ deep learning (DL) approach to replace the iterative approaches, therefore allowing hundreds of times faster recovery of the object. We developed AutoPhaseNN, a DL-based approach which learns to solve the inverse problem without labeled data. Taking 3D BCDI as a representative technique, AutoPhaseNN has been demonstrated to be one hundred times faster than traditional iterative phase retrieval methods while providing comparable image quality. The current network is trained with 64 x 64 x 64 data size, to achieve higher resolution imaging, we will need to scale the network to input and train/infer 3D arrays of size 256 x 256 x 256 (today) and of size 2560x2560x2560 (APSU). However, the scalability of the network is restricted due to the memory-intensive training process. To perform the training for a 256 x 256 x 256 data size, the required memory exceeds the capacity of the current machine. In this project, we explore using Sambanova system to train the network for the direct data inversion for CDI.

36 MATERIALS SCIENCE↗

Ptychography at the Linac Coherent Light Source in a parasitic geometry

X-ray free-electron lasers (FELs) are being recognized as a powerful tool in an ever-increasing number of research fields, but are very limited as to the number of experiments that they can support. This work shows that more beamtime could be made available by using `parasitic' geometries, where a secondary experiment uses the X-ray beam that the primary experiment does not utilize. The first successful ptychography experiment, a scanning coherent diffractive imaging technique, in a parasitic geometry at an X-ray FEL is demonstrated. Utilizing the CXI hutch at the Linac Coherent Light Source (LCLS), it is shown that the obtained data are of high quality and that characterizing the beam using ptychography can be much faster than traditional imprinting methods.

42 ENGINEERING↗

Utilizing broadband X-rays in a Bragg coherent X-ray diffraction imaging experiment

A method is presented to simplify Bragg coherent X-ray diffraction imaging studies of complex heterogeneous crystalline materials with a two-stage screening/imaging process that utilizes polychromatic and monochromatic coherent X-rays and is compatible with in situ sample environments. Coherent white-beam diffraction is used to identify an individual crystal particle or grain that displays desired properties within a larger population. A three-dimensional reciprocal-space map suitable for diffraction imaging is then measured for the Bragg peak of interest using a monochromatic beam energy scan that requires no sample motion, thus simplifying in situ chamber design. This approach was demonstrated with Au nanoparticles and will enable, for example, individual grains in a polycrystalline material of specific orientation to be selected, then imaged in three dimensions while under load.

36 MATERIALS SCIENCE↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗