Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “channel calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Satellite Remote Sensing Estimation of River Discharge: Application to the Yukon River Alaska

A methodology based on general hydraulic relations for rivers has been developed to estimate the discharge (flow rate) of rivers using satellite remote sensing observations. The estimates of discharge, flow depth, and flow velocity are derived from remotely observed water surface area, water surface slope, and water surface height, and demonstrated for two reaches of the Yukon River in Alaska, at Eagle (reach length 34.7 km) and near Stevens Village (reach length 38.3 km). The method is based on fundamental equations of hydraulic flow resistance in rivers, including the Manning equation and the Prandtl-von Karman universal velocity distribution equation. The method employs some new hydraulic relations to help define flow resistance and height of the zero flow boundary in the channel. Estimates are made both with and without calibration. The water surface area of the river reach is measured by using a provisional version of the U.S. Geological Survey (USGS) Landsat based product named Dynamic Surface Water Extent (DSWE). The water surface height and slope measurements require a self-consistent datum, and are derived from observations from the Jason-2 satellite altimeter mission. At both reach locations, the Jason-2 radar altimeter non-winter heights consistently tracked the stage recorded at USGS streamgages with a standard deviation of differences (error) during the non-winter periods of less than 7%. Part of the error may be due to differences in the gage and altimeter crossing locations with respect to the range of stage change and the response to changes in discharge at the upstream and downstream locations. For the non-winter periods, the radar derived slope estimates (mean = 0.0003) were constant over the mission lifetime, and in agreement with previously measured USGS water surface slopes and slopes determined from USGS topographic maps. The accuracy of the mean of the uncalibrated daily estimates of discharge varied between reaches, ranging from 13% near Stevens Village (N = 90) to −21% at Eagle (N = 246) based on the absolute error, and 5% to −6% based on the error of the log of the estimates. Calibrating to the mean of USGS daily discharge estimates from the streamflow rating for the same period of record at each streamgage resulted in mean absolute errors ranging from 1% to 2%, and log errors ranging from 1% or less. The error pattern of the estimates shows that without calibration, even though the mean is well simulated, the high and low end values over the range of estimates may have significant bias.

Bjerklie, David M.↗

Submm polarimetric radiometers for investigations of distribution and size of ice in clouds' top layers

The sources of uncertainty in climate models are many and varied. Over the years, experiment and theory have reduced their importance and extent, but the effect of clouds, and ice clouds in particular, remains poorly understood. The effects of ice clouds are often used as tuning parameters, to balance the budget of incoming and outgoing radiation at the top of the atmosphere and achieve energy equilibrium. NASA's Aerosol, Cloud and Ecosystems (ACE), an Earth Science Decadal Survey (DS) mission, recommends that a science payload with submillimeter wave (sub-mm) and longwave infrared(LWIR) radiometers be developed for such cloud ice measurement. This paper reports on the calibration and characterization of the sub-millimeter channels of one such instrument.

G De Amici↗

Improving the longest SI traceable hyperspectral infrared record from space from the AIRS

The Atmospheric Infrared Sounder (AIRS) is a “facility” instrument developed by NASA as an experimental demonstration of advanced technology for remote sensing and the benefits of high resolution infrared spectra to weather forecasting and science investigations . It was launched into a 1:30 am/pm polar orbit on May 4, 2002 on the EOS Aqua Spacecraft, and is expected to provide highly calibrated data beyond 2024. AIRS has 2378 infrared channels ranging from 3.7 um to 15.4 um and a 13.5 km footprint. The AIRS data are used for weather forecasting, climate process studies and validating climate models. AIRS is a vital IR reference sensor for GSICS and is used by JMA for comparison to Himawari AHI , KMA for comparison to COMS , NOAA for comparison to CrIS and GOES , and EUMETSAT for comparison to IASI .

Strow, Larrabee↗

Validation of the CERES Shortwave Measurements over Desert and Cloud Scenes

The Clouds and the Earth's Radiant Energy System (CERES) broadband shortwave channel, 0.3 - 5 micron, measures atmosphere and surface reflected solar radiation. CERES provides an in-flight tungsten lamp to monitor the shortwave radiometric stability over the lifetime of the instrument. Initial Tropical Rainfall Measurement Mission (TRMM) tungsten calibration results indicate a 0.6% change over the first six months of mission life. The three channel intercomparison technique and the solar diffuser calibration results show shortwave stabilities of 0.2% and 0.3% for the same time period. Current belief is that the tungsten lamp, not the radiometer, has drifted. Radiometers, optics, and onboard calibrators exposed to the harsh space environment often degrade. Independent validation studies based on bright Earth viewing measurements are necessary to support the in-flight filtered calibration results. Instrument measurements of filtered radiances are

Currey, Chris↗

Deformable Mirror Optical Calibration and Test Results

We describe the initial setup, configuration, and component level testing procedures that were used to incorporate a Xinetics 349 channel deformable mirror into the DCATT active optical system. Initial flattening results are presented as well as calibration data on actuator gain and mirror response. The RMS measures of surface quality are also analyzed for drift in the power-up state.

Dean, Bruce H.↗

Calibration, testing and orbital performance of the halogen occultation experiment (HALOE) on the upper atmosphere research satellite

HALOE is an occultation viewing radiometer that requires part per million signal precision and characterization. Gas correlation radiometry is used to infer HF HCl, CH4 and NO concentrations, while broad band radiometry is used for temperature, pressure, O3, H2O and NO2. Validated results verify that goals have been met or exceeded in all channels. This was achieved through a comprehensive instrument analysis and calibration process on the ground and in orbit. Components and systems were put through a battery of tests in the lab. In orbit, a variety of exoatmospheric solar disk measurements are used for precise real time inferral of critical calibration parameters. In the end, technical success was based on the close interaction of scientist, engineer and data analysts. The accuracy and precision of HALOE species profiles are equal to any ever achieved from orbiting sensors.

Gordley, Larry L.↗

Enhancements to the Open Access Spectral Band Adjustment Factor Online Calculation Tool for Visible Channels

With close to 40 years of satellite observations, from which, cloud, land-use, and aerosol parameters can be measured, inter-consistent calibrations are needed to normalize retrievals across satellite records. Various visible-sensor inter-calibration techniques have been developed that utilize radiometrically stable Earth targets, e.g., deep convective clouds and desert/polar ice pseudo-invariant calibration sites. Other equally effective, direct techniques for intercalibration between satellite imagers are simultaneous nadir overpass comparisons and ray-matched radiance pairs. Combining independent calibration results from such varied techniques yields robust calibration coefficients, and is a form of self-validation. One potential source of significant error when cross-calibrating satellite sensors, however, are the often small but substantial spectral discrepancies between comparable bands, which must be accounted for. As such, visible calibration methods rely on a Spectral Band Adjustment Factor (SBAF) to account for the spectral-response function- induced radiance differences between analogous imagers. The SBAF is unique to each calibration method as it is a function of the Earth-reflected spectra. In recent years, NASA Langley pioneered the use of SCIAMACHY-, GOME-2-, and Hyperion-retrieved Earth spectra to compute SBAFs. By carefully selecting hyperspectral footprints that best represent the conditions inherent to an inter-calibration technique, the uncertainty in the SBAF is greatly reduced. NASA Langley initially provided the Global Space-based Inter-calibration System processing and research centers with online SBAF tools, with which users select conditions to best match their calibration criteria. This article highlights expanded SBAF tool capabilities for visible wavelengths, with emphasis on the use of the spectral range filtering for the purpose of separating scene conditions for the channel that the SBAF is needed based on the reflectance values of other bands. In other words, spectral filtering will enable better scene-type selection for bands where scene determination is difficult without information from other channels, which should prove valuable to users in the calibration community.

Scarino, Benjamin↗

A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

Heath, Donald F.↗

Evaluation of the Tau-Omega Model over a Dense Corn Canopy at P- and L-band

As an emerging technique, P-band (0.3-1GHz) may improve soil moisture remote sensing compared to L-band (1.4 GHz) SMOS (Soil Moisture and Ocean Salinity) and SMAP (Soil Moisture Active Passive) missions, because of its greater moisture retrieval depth resulting from its longer wavelength. Consequently, a number of tower-based experiments were undertaken in Victoria, Australia, to understand and quantify potential improvements. The study reported here has extended the evaluation of the tau-omega model to a scenario with a dense corn canopy whose vegetation water content reached ~20 kg/m 2 , and compared the soil moisture retrieval performance at P- and L-band. Based on the locally calibrated parameters, the results from both the SCA (Single Channel Algorithm) and DCA (Dual Channel Algorithm) approaches presented a clear reduction in vegetation impact at P-band compared to L-band. While the root-mean-square error (RMSE) for P-band did not achieve the 0.04-m 3 /m 3 target accuracy of SMOS and SMAP, i.e., 0.054 m 3 /m 3 for the SCA and 0.074 m 3 /m 3 for the DCA, this performance can be regarded as acceptable considering the extremely high vegetation water content. In comparison, the RMSEs at L-band were larger than 0.1 m 3 /m 3 for both the SCA and the DCA approaches. Additionally, DCA performed better in correlation coefficient and unbiased RMSE, while SCA performed better in RMSE at P-band due to the larger bias when using DCA. Moreover, the calibrated vegetation parameters at P-band were found to apply to broader conditions than those at L-band, likely due to the reduced vegetation impact.

P-band↗

Determination of the in-flight spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

AVIRIS is a science research imaging spectrometer that measures radiance in 224 channels between 400 to 2450 nm in the electromagnetic spectrum. To determine the inflight spectral and radiometric characteristics of AVIRIS a validation and calibration experiment was performed. Five data sets were acquired over a calibration site on the homogeneous playa of Rogers Dry Lake, California, U.S. Surface reflectance, atmospheric optical depths, and atmospheric water vapor measurements were acquired concurrently with the overflights. These in situ measurements were used to constrain the LOWTRAN 7 radiative transfer code to predict the total spectral radiance incident at the AVIRIS aperture. These predicted radiances and the AVIRIS measured radiances were analyzed to validate the inflight characteristics. Inflight spectral channel positions and response functions over the AVIRIS spectral range were derived. Radiometric calibration coefficients were calculated for each channel as well as radiometric accuracy, intraflight stability, and noise equivalent delta radiance.

Green, Robert O.↗

Observations of the galactic plane by the zodiacal infrared project

The two rocket flights of the Zodiacal Infrared Project (ZIP), flown 18 August 1980 and 31 July 1981, were intended to provide data on the near-infrared thermal emission of the interplanetary dust cloud over a broad range of ecliptic coordinates (latitudes -60 to +85 degrees, solar elongation angles 22 to 90 degrees and 140 to 180 degrees). In addition, their multiple crossings of the Galactic plane provided low resolution spectral data (delta lambda/lambda ranging from 1. to 0.1, for effective wavelengths from 3 to 30 microns) for most of the first quadrant (longitudes 30 to 100 degrees). Examples are displayed. Having made a thorough reanalysis of the calibration of the ZIP database, researchers present the salient features of the Galactic plane as observed by ZIP. The binned, in-plane data, corrected for zodiacal emission, generally show an exponential decrease with increasing longitude. The fitted exponential scale-length is 0.038/degree, and can be inverted to derive a radial density profile. Channel ratios are converted to temperatures by using model spectra in which thermal emitters with emissivity approx. 1/lambda are convolved with the filter responses. The results for channels 5 (11 microns) and 12 (21 microns) are shown, along with similarly derived temperatures from Infrared Astronomy Satellite (IRAS) 12 microns and 25 microns data. The ZIP data show little variation with longitude, consistent with IRAS results. A narrow spectral feature at 13 microns appears consistently in data for the plane (uncorrected for zodiacal emission). However, this is strongly contaminated by calibration problems for channel 8. Researchers suggest that residual emission at 13 microns arises from the (NeII) line at 12.8 microns.

Rickard, L. J.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Activities within the period from July 1, 1992 through December 31, 1992 by Georgia Tech researchers in millimeter and submillimeter wavelength tropospheric remote sensing have been centered around the calibration of the Millimeter-wave Imaging Radiometer (MIR), preliminary flight data analysis, and preparation for TOGA/COARE. The MIR instrument is a joint project between NASA/GSFC and Georgia Tech. In the current configuration, the MIR has channels at 90, 150, 183(+/-1,3,7), and 220 GHz. Provisions for three additional channels at 325(+/-1,3) and 8 GHz have been made, and a 325-GHz receiver is currently being built by the ZAX Millimeter Wave Corporation for use in the MIR. Past Georgia Tech contributions to the MIR and its related scientific uses have included basic system design studies, performance analyses, and circuit and radiometric load design, in-flight software, and post-flight data display software. The combination of the above millimeter wave and submillimeter wave channels aboard a single well-calibrated instrument will provide unique radiometric data for radiative transfer and cloud and water vapor retrieval studies. A paper by the PI discussing the potential benefits of passive millimeter and submillimeter wave observations for cloud, water vapor and precipitation measurements has recently been published, and is included as an appendix.

Gasiewski, Albin J.↗

Lightning radiometry in visible and infrared bands

Calibrated measurements of lightning optical emissions are critical for both quantifying the impacts of lightning in our atmosphere and devising detection instruments with sufficient dynamic range capable of yielding close to 100% detection efficiency. However, to date, there is only a limited number of investigations that have attempted to take such calibrated measurements. Here, in this work, we report the power radiated by lightning in both visible and infrared bands, assuming isotropic emission, and accounting for atmospheric absorption. More precisely, we report peak radiated power and total radiated energy in the combined visible plus near-infrared range (VNIR, 0.34–1.1 μm), around the H α line (652–667 nm), and for the 2–2.5 μm infrared band. The estimated peak power and total energy radiated by negative cloud-to-ground return strokes in the VNIR range is 130 MW and 20 kJ, respectively. Additionally, we detected peak radiated powers of 12 and 0.19 MW in the H α and infrared bands, respectively. We cross-reference the optical data set with peak current reported by a lightning detection network. The resulting trend is that optical power emitted around the H α line scales with peak return stroke current according to a power law with exponent equal to 1.25. This trend, which should be approximately true across the entire visible spectrum, can be attributed to the plasma negative differential resistance of the lightning return stroke channel. We conclude by discussing the challenges in performing calibrated measurements of lightning optical power in different bands and comparing the results with previously-collected data with different experimental setups, observation conditions, and calibration methods.

54 ENVIRONMENTAL SCIENCES↗

Advanced Signal Conditioners for Data-Acquisition Systems

Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

Lucena, Angel↗

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan↗

Search for Higgs boson production at high transverse momentum in the WW decay channel in proton-proton collisions at $\sqrt{s}=13$ TeV

A search for Higgs boson (H) production at high transverse momentum (p T ) in the WW decay channel is presented. The analysis uses proton-proton collisions at $\sqrt{s}=13$ TeV recorded by the CMS experiment in 2016–2018, corresponding to an integrated luminosity of 138 fb −1 . The visible decay products of the Higgs boson are reconstructed as a single large-radius jet with one isolated lepton or none (1ℓ and 0ℓ, respectively; ℓ = e, μ). The H-candidate jets are identified using an advanced transformer-based algorithm and are calibrated with the Lund jet plane reweighting technique. The 1ℓ channel is further split into gluon fusion, vector boson fusion, and associated production with hadronically decaying vector boson categories, while the 0ℓ channel considers all production processes inclusively. The measured cross section times the H → WW branching fraction relative to the standard model expectation is $\mu =-{0.19}_{-0.46}^{+0.48}$, indicating no evidence of a signal above the background. This measurement represents the first dedicated study of highly Lorentz-boosted H → WW decays, complementing earlier searches for high-p T Higgs boson in other decay channels.

Hadron-Hadron Scattering↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

Electron cyclotron emission measurements and modeling in optically semi-transparent plasma on the HSX stellarator

On the Helically Symmetric Experiment (HSX), electron cyclotron emission (ECE) at the second harmonic of the electron gyrofrequency is measured with a 16-channel heterodyne receiver. An ECE radiometer diagnostic has been calibrated with a broadband frequency source, allowing independent measurements of the electron temperature. The antenna pattern has a significant impact on the measurements, and modeling its effect is necessary to produce an ECE radiation temperature spectrum. Measurements, calibration results, and modeling of the ECE data are presented in this paper. At a relatively high plasma density, HSX plasmas are thermal, and the radiation temperature measured by the radiometer is in good agreement with the electron temperature measured by a Thomson scattering diagnostic. At a relatively low plasma density, the deviation from a Maxwellian distribution is large, and asymmetry in the radiation temperature profile is measured. These measurements are supported by single-pass and multi-pass ray tracing calculations of the electron cyclotron emission using the TRAVIS ray tracing code. Thermal and nonthermal electron populations exist in HSX, and the effect of these populations on the asymmetry in the measured emission is presented.

Cyclotron radiation↗