Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “centrality measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ultrahigh-efficiency, very narrow-passband, tunable optical filter

Recently developed technologies have been uniquely integrated to produce optical filters with unprecedented performance. The precise design and fabrication of narrow-passband and high-efficiency optical filters with a central frequency of 532 nm are reported. Measurements with these filters demonstrate a performance that accurately mirrors the design specification, with one filter having a passband of 70 pm and an efficiency greater than 90% and the second filter having a passband of 7 pm and an efficiency greater than 80%.

Sandford, Stephen P.↗

Forecasting Coronal Mass Ejections from Vector Magnetograms

Identification of active regions from which Earthward halo Coronal Mass Ejections (CMEs) are likely to originate is important both for understanding how CMEs are produced and for prediction of hazardous space weather. In previous work, from a set of 17 MSFC (Marshall Space Flight Center) vector magnetograms of 12 bipolar active regions situated within +/- 2 days of rotation from central meridian, we have evaluated four different measures of the global nonpotentiality of the magnetic field of each active region, and have found that the nonpotentiality of these active regions is strongly correlated with their CME productivity during the time interval of +/- 2 days centered on the day of the magnetogram: strongly nonpotential bipolar active regions are much more likely to produce a CME during this interval that are weakly nonpotential bipolar active regions. To further establish the use of active-region nonpotentiality for forecasting CMEs, we have expanded the sample to 19 additional bipolar active regions, with vector magnetograms taken with the upgraded MSFC vector magnetograph from September 2000 through June 2001 with support from our LWS grant (M. J. Hagyard, PI). The four global measures of nonpotentiality are the length of strong-shear, strong-field main neutral line, the net current, and two other measures of the overall twist in the magnetic field of the active-region bipole. We find: 1) The statistical significance of the correlation of the nonpotentiality of active regions with their CME productivity within +/- 2 days of the day of the magnetogram is greater than 99%. 2) 67% of the strongly nonpotential active regions produced CMEs within the +/- 2 day window, while only 17% of the weakly nonpotential ones did. 3) The statistical significance of the correlation of the nonpotentiality of active regions with their CME productivity during 0-2 days after the day of the magnetogram is about 97%. 4) 42% of the strongly nonpotential active regions produced CMEs within the 0-2 day window, while only 10% of the weakly nonpotential ones did. 5) The four different measures of an active region's nonpotentiality agree most of the time in their classification of the nonpotentiality as strong or weak (75%-90% depending on the pair of measurements). Additional information is included in the original extended abstract.

Moore, R. L.↗

GRACE Gravity Data Target Possible Mega-impact in North Central Wilkes Land, Antarctica

A prominent positive GRACE satellite-measured free-air gravity anomaly over regionally depressed subglacial topography may identify a mascon centered on (70 deg S, 120 deg E) between the Gamburtsev and Transantarctic Mountains of East Antarctica. Being more than twice the size of the Chicxulub crater, the inferred Wilkes Land impact crater is a strong candidate for a Gondwana source of the greatest extinction of life at the end of the Permian. Its ring structure intersects the coastline and thus may have strongly influenced the Cenozoic rifting of East Antarctica from Australia that resulted in the enigmatic lack of crustal thinning on the conjugate Australian block.

vonFrese, Ralph R. B.↗

Dose-Response Evaluation of Braslet-M Occlusion Cuffs

Introduction: Braslet-M is a set of special elasticized thigh cuffs used by the Russian space agency to reduce the effects of the head-ward fluid shift during early adaptation to microgravity by sequestering fluid in the lower extremities. Currently, no imaging modalities are used in the calibration of the device, and the pressure required to produce a predictable physiological response is unknown. This investigation intends to relate the pressure exerted by the cuffs to the extent of fluid redistribution and commensurate physiological effects. Materials and Methods: Ten healthy subjects with standardized fluid intake participated in the study. Data collection included femoral and internal jugular vein imaging in two orthogonal planes, pulsed Doppler of cervical and femoral vessels and middle cerebral artery, optic nerve imaging, and echocardiography. Braslet-M cuff pressure was monitored at the skin interface using pre-calibrated pressure sensors. Using 6 and 30 head-down tilt in two separate sessions, the effect of Braslet-M was assessed while incrementally tightening the cuffs. Cuffs were then simultaneously released to document the resulting hemodynamic change. Results: Preliminary analysis shows correlation between physical pressure exerted by the Braslet-M device and several parameters such as jugular and femoral vein cross-sections, resistivity of the lower extremity vascular bed, and others. A number of parameters reflect blood redistribution and will be used to determine the therapeutic range of the device and to prevent unsafe application. Conclusion: Braslet-M exerts a physical effect that can be measured and correlated with many changes in central and peripheral hemodynamics. Analysis of the full data set will be required to make definitive recommendations regarding the range of safe therapeutic application. Objective data and subjective responses suggest that a safer and equally effective use of Braslet can be achieved when compared with the current non-imaging calibration techniques.

Ebert, Douglas↗

Multidimensional analysis of fast-spectrum material replacement measurements for systematic estimation of cross section uncertainties

A series of central core and core-reflector interface sample replacement experiments for 16 materials performed in the NASA heavy-metal-reflected, fast spectrum critical assembly (NCA) were analyzed in four and 13 groups using the GAM 2 cross-section set. The individual worths obtained by TDSN and DOT multidimensional transport theory calculations showed significant differences from the experimental results. These were attributed to cross-section uncertainties in the GAM 2 cross sections. Simultaneous analysis of the measured and calculated sample worths permitted separation of the worths into capture and scattering components which systematically provided fast spectrum averaged correction factors to the magnitudes of the GAM 2 absorption and scattering cross sections. Several Los Alamos clean critical assemblies containing Oy, Ta, and Mo as well as one of the NCA compositions were reanalyzed using the corrected cross sections. In all cases the eigenvalues were significantly improved and were recomputed to within 1 percent of the experimental eigenvalue. A comparable procedure may be used for ENDF cross sections when these are available.

Klann, P. G.↗

Diminished forearm vasomotor response to central hypervolemic loading in aerobically fit individuals

The aim of this study was to test the hypothesis that cardiopulmonary baroreflex control of forearm vascular resistance (FVR) during central hypervolemic loading was less sensitive in exercise trained high fit individuals (HF) compared to untrained average fit individuals (AF). Eight AF (age: 24 +/- 1 yr and weight: 78.9 +/- 1.7 kg) and eight HF (22 +/- 1 yr 79.5 +/- 2.4 kg) voluntarily participated in the investigation. Maximal aerobic power (determined on a treadmill), plasma volume and blood volume (Evans blue dilution method) were significantly greater in the HF than AF (60.8 +/- 0.7 vs. 41.2 +/- 1.9 ml.kg-1.min-1, 3.96 +/- 0.17 vs 3.36 +/- 0.08 1, and 6.33 +/- 0.23 vs 5.28 +/- 0.13 1). Baseline heart rate (HR), central venous pressure (CVP), mean arterial pressure (MAP, measured by an intraradial catheter or a Finapres finger cuff), forearm blood flow (FBF, plethysmography), and FVR, calculated from the ratio (MAP-CVP)/FBF, were not different between the HF and the AF. Lower body negative pressure (LBNP, -5, -10, -15, and -20 torr) and passive leg elevation (LE, 50 cm) combined with lower body positive pressure (LBPP, +5, +10, and +20 torr) were utilized to elicit central hypovolemia and hypervolemia, respectively. Range of CVP (from LBNP to LE+LBPP) was similar in the AF (from -3.9 to +1.9 mm Hg) and HF (from -4.0 to +2.2 mm Hg). However, FVR/CVP was significantly less in the HF (-1.8 +/- 0.1 unit.mm Hg-1) than AF (-34 +/- 0.1 unit.mm Hg-1). The FVR decrease in response to increase in CVP was significantly diminished in the HF (-1.46 +/- 0.45 unit.mm Hg-1) compared to the AF (-4.40 +/- 0.97 unit.mm Hg-1), and during LBNP induced unloading the FVR/CVP of the HF (-2.01 +/- 0.49 unit.mm Hg-1) was less (P < 0.08) than the AF (-3.28 +/- 0.69 unit.mm Hg-1). We concluded that the cardiopulmonary baroreceptor mediated FVR reflex response was significantly less sensitive to changes in CVP in individuals who practice exercise training.

NASA Discipline Number 93-10↗

An Event-Based Approach to Distributed Diagnosis of Continuous Systems

Distributed fault diagnosis solutions are becoming necessary due to the complexity of modern engineering systems, and the advent of smart sensors and computing elements. This paper presents a novel event-based approach for distributed diagnosis of abrupt parametric faults in continuous systems, based on a qualitative abstraction of measurement deviations from the nominal behavior. We systematically derive dynamic fault signatures expressed as event-based fault models. We develop a distributed diagnoser design algorithm that uses these models for designing local event-based diagnosers based on global diagnosability analysis. The local diagnosers each generate globally correct diagnosis results locally, without a centralized coordinator, and by communicating a minimal number of measurements between themselves. The proposed approach is applied to a multi-tank system, and results demonstrate a marked improvement in scalability compared to a centralized approach.

Daigle, Matthew↗

Event Detection in Aerospace Systems using Centralized Sensor Networks: A Comparative Study of Several Methodologies

Recent advances in micro electromechanical systems technology, digital electronics, and wireless communications have enabled development of low-cost, low-power, multifunctional miniature smart sensors. These sensors can be deployed throughout a region in an aerospace vehicle to build a network for measurement, detection and surveillance applications. Event detection using such centralized sensor networks is often regarded as one of the most promising health management technologies in aerospace applications where timely detection of local anomalies has a great impact on the safety of the mission. In this paper, we propose to conduct a qualitative comparison of several local event detection algorithms for centralized redundant sensor networks. The algorithms are compared with respect to their ability to locate and evaluate an event in the presence of noise and sensor failures for various node geometries and densities.

Mehr, Ali Farhang↗

An intercalibration of Meteosat-1 and GOES-2 visible and infrared measurements

An intercomparison between radiative parameters determined from visible and infrared channels of the Meteosat-1 and GOES-2 geosynchronous satellites has been carried out using data obtained over the central Atlantic Ocean for 5 November 1978. Hourly visible-infrared measurement pairs at a nominal resolution of 5 km (Meteosat) or 8 km (GOES) have been stored in 1 deg x 1 deg longitude-latitude regions. For the infrared intercomparisons, the GOES 11.5 micron radiance has been compared to Meteosat infrared counts. The scatter in partly cloudy regions is interpreted as being caused by meteorological differences arising from differences in measurement time between the two data sets. For the visible intercomparison, the GOES measurements for clear and cloudy scenes have first been converted with the aid of scene-dependent angular reflectance and albedo models to estimates of the filtered shortwave radiance that GOES would have measured had it been in the Meteosat position. This value has then been compared to Meteosat counts for the shortwave channel. The results indicate that earlier Meteosat calibrations made from airplane overflights of a limited variety of surfaces are applicable to much larger areas of cloud and ocean.

Brooks, D. R.↗

A critical evaluation of semianalytic methods in the study of centrally heated, unresolved, infrared sources

We critically evaluate current methods of analysis in infrared (IR) astronomy and investigate the conditions under which these semianalytic methods are reliable. Specifically we examine the usual assumptions of homogeneities in dust density and temperature, and neglect of opacity effects when applied to internally heated, unresolved IR sources. To accomplish this, a series of radiation transport models for these sources have been constructed. The model results are treated as observed quantities and analyzed to derive the source parameters, using simple semianalytic methods. The discrepancies between the derived and actual model parameters can then be attributed to the limitations of the analysis methods and provide a measure of their reliability. Applying this approach to centrally heated, unresolved IR sources, we have studied in detail the following diagnostic problems: (1) determination of dust mass from monochromatic and integrated luminosities; (2) estimation of dust temperature distribution from color temperatures derived from the flux spectrum; and (3) determination of the empirical grain emissivity law (opacity function) for both continuum and spectral features.

Doty, Steven D.↗

A Landsat study of water quality in Lake Okeechobee

This paper uses multiple regression techniques to investigate the relationship between Landsat radiance values and water quality measurements. For a period of over one year, the Central and Southern Florida Flood Control District sampled the water of Lake Okeechobee for chlorophyll, carotenoids, turbidity, and various nutrients at the time of Landsat overpasses. Using an overlay map of the sampling stations, Landsat radiance values were measured from computer compatible tapes using a GE image 100 and averaging over a 22-acre area at each station. These radiance values in four bands were used to form a number of functions (powers, logarithms, exponentials, and ratios), which were then compared with the ground measurements using multiple linear regression techniques. Several dates were used to provide generality and to study possible seasonal variations. Individual correlations were presented for the various water quality parameters and best fit equations were examined for chlorophyll and turbidity. The results and their relationship to past hydrological research were discussed.

Gervin, J. C.↗

Ignitability test method and apparatus

An apparatus for testing ignitability of an initiator includes a body having a central cavity, an initiator holder for holding the initiator over the central cavity of the body, an ignition material holder disposed in the central cavity of the body and having a cavity facing the initiator holder which receives a measured quantity of ignition material to be ignited by the initiator. It contains a chamber in communication with the cavity of the ignition material and the central cavity of the body, and a measuring system for analyzing pressure characteristics generated by ignition of the ignition material by the initiator. The measuring system includes at least one transducer coupled with an oscillograph for recording pressure traces generated by ignition.

Bement, Laurence J.↗

Spectral observations of Eta Carinae at 4 microns

Spectral observations of the central region of the Eta Carinae nebula at 4 microns have measured the Brackett-alpha hydrogen recombination-line intensity. The bulk of the line and continuum radiation arises in a small central source which is slightly narrower in the line radiation and is barely resolved by the employed beamwidth of 3.4 arcsec. The continuum radiation is well-fitted by an exponential relation to a distance of 10 arcsec from the central source. The line intensity requires a central source which emits 10 to the 49th power ionizing photons per sec into a region of electron density greater than 1 million per cu cm.

Aitken, D. K.↗

Development and structure of a rectangular jet in a multiple jet configuration

Results of hot-wire measurements in an incompressible jet issuing from an array of rectangular lobes, equally spaced with their small dimensions in a line, are presented. The quantities measured include mean velocity and the Reynolds stress in the two central planes of the jet at stations covering up to 115 widths (small dimension of the lobe) downstream of the nozzle exit. Measurements are carried out on a single rectangular free jet and on the same jet in a multiple jet configuration. In the case of a multiple jet, the flowfield for downstream distance X greater than 60D (D = width of the lobe) resembles that of a jet exiting from a two-dimensional nozzle with its short dimension being the long dimension of the lobe. The field of turbulence is found to be nearly isotropic in the plane containing the small dimension of the lobes for X greater than 60D.

Krothapalli, A.↗

Global Precipitation Measurement (GPM) Ground Validation: Plans and Preparations

The Global Precipitation Measurement (GPM) program is an international partnership led by the National Aeronautics and Space Administration (NASA) and the Japan Aerospace Exploration Agency (JAXA). GPM will improve climate, weather, and hydro-meteorological forecasts through more frequent and more accurate measurement of precipitation across the globe. This paper describes the concept, the planning, and the preparations for Ground Validation within the GPM program. Ground Validation (GV) plays an important role in the program by investigating and quantitatively assessing the errors within the satellite retrievals. These quantitative estimates of retrieval errors will assist the scientific community by bounding the errors within their research products. The two fundamental requirements of the GPM Ground Validation program are: (1) error characterization of the precipitation retrievals and (2) continual improvement of the satellite retrieval algorithms. These two driving requirements determine the measurements, instrumentation, and location for ground observations. This paper outlines GV plans for estimating the systematic and random components of retrieval error and for characterizing the spatial p d temporal structure of the error and plans for algorithm improvement in which error models are developed and experimentally explored to uncover the physical causes of errors within the retrievals. This paper discusses NASA locations for GV measurements as well as anticipated locations from international GPM partners. NASA's primary locations for validation measurements are an oceanic site at Kwajalein Atoll in the Republic of the Marshall Islands and a continental site in north-central Oklahoma at the U.S. Department of Energy's Atmospheric Radiation Measurement Program site.

Schwaller, M.↗

The moon - Mid-infrared (7.5- to 11.4-microns) spectroscopy of selected regions

Scaled spectral emissivity spectra have been obtained from five locations on the illuminated lunar surface and are interpreted in terms of differences in their mineralogic composition. The emission maximum, which typically falls near 8.0 microns for lunar rocks and fines, is observed to be shifted from 7.9 microns for noritic Copernicus crater walls to 8.1 microns for the olivine-rich central peak. Two mare locations show the emission maximum centered at 8.0 microns, consistent with laboratory emission measurements of basalts. An emissivity minimum at 10.5 microns in the spectrum from central peak 2 is attributed to the presence of olivine. Minima centered at 8.75 microns in the crater wall spectra resemble minima in laboratory spectra from pyroxene. A broad minimum centered at 8.5 microns in the Kepler ejecta spectrum and a sharp drop in emissivity at wavelengths longer than 11 microns in spectra from both mare locations suggest plagioclase.

Sprague, A. L.↗

Measuring the Mass Distribution in Z is Approximately 0.2 Cluster Lenses with XMM, HST and CFHT

Being the most massive gravitationally bound objects in the Universe, clusters of galaxies are prime targets for studies of structure formation and evolution. Specifically the comoving space density of virialized clusters of a given mass (or X-ray temperature), but also the frequency and degree of substructure, as well as the shape of the cluster mass profile are quantities whose current values and evolution as a function of lookback time can provide important constraints on the cosmological and physical parameters of structure formation theories. The project funded by NASA grant NAG 5-10041 intended to take such studies to a new level by combining observations of a well-selected cluster sample by three state-of-the-art telescopes: HST, to accurately measure the mass distribution in the cluster core (approx. 0.5 h(sup -1)(sub 50) Mpc) via strong gravitational lensing; CFHT, to measure the large scale mass distribution out to approx. 3 Mpc via weak lensing; and XMM, to measure the gas density and temperature distribution accurately on intermediate scales < 1.5 Mpc. XMM plays a pivotal role in this context as the calibration of X-ray mass measurements through accurate, spatially resolved X-ray temperature measurements (particularly in the cosmologically most sensitive range of kT> 5 keV) is central to the questions outlined above. This set of observations promised to yield the best cluster mass measurements obtained so far for a representative sample, thus allowing us to: 1) Measure the high-mass end of the local cluster mass function; 2) Test predictions of a universal cluster mass profile; 3) calibrate the mass-temperature and temperature-luminosity relations for clusters and the scatter around these relations, which is vital for studies of cluster evolution using the X-ray temperature and X-ray luminosity functions.

Source record↗

Local Estimators for Spacecraft Formation Flying

A formation estimation architecture for formation flying builds upon the local information exchange among multiple local estimators. Spacecraft formation flying involves the coordination of states among multiple spacecraft through relative sensing, inter-spacecraft communication, and control. Most existing formation flying estimation algorithms can only be supported via highly centralized, all-to-all, static relative sensing. New algorithms are needed that are scalable, modular, and robust to variations in the topology and link characteristics of the formation exchange network. These distributed algorithms should rely on a local information-exchange network, relaxing the assumptions on existing algorithms. In this research, it was shown that only local observability is required to design a formation estimator and control law. The approach relies on breaking up the overall information-exchange network into sequence of local subnetworks, and invoking an agreement-type filter to reach consensus among local estimators within each local network. State estimates were obtained by a set of local measurements that were passed through a set of communicating Kalman filters to reach an overall state estimation for the formation. An optimization approach was also presented by means of which diffused estimates over the network can be incorporated in the local estimates obtained by each estimator via local measurements. This approach compares favorably with that obtained by a centralized Kalman filter, which requires complete knowledge of the raw measurement available to each estimator.

Fathpour, Nanaz↗