Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ceil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance and Costs of Ductless Heat Pumps in Marine-Climate High-Performance Homes Habitat for Humanity The Woods

The Washington State University (WSU) Energy Program's Building America (BA) team conducted a case study of a high-performance affordable housing community: The Woods (Figure 1). This BA effort is part of a larger-scale study of 30 homes funded from 2013-2016 by Tacoma Public Utilities (TPU) and the Bonneville Power Administration. The Woods is a Habitat for Humanity (HFH) community of homes certified by ENERGY STAR Homes Northwest (ESHNW); the community is in the marine climate of Tacoma/Pierce County, Washington. This research report builds on an earlier preliminary draft 2014 BA report and includes significant billing analysis and cost-effectiveness research from a collaborative and ongoing DHP research effort for TPU and the Bonneville Power Administration. This final BA report focuses on the results of field testing, modeling, and monitoring of ductless mini-split heat pump hybrid heating systems in seven homes built and first occupied at various times between September 2013 and October 2014. The report also provides WSU documentation of high-performance home observations, lessons learned, and stakeholder recommendations for builders of affordable high-performance housing. The research goal of the U.S. Department of Energy's BA research team Building America Partnership for Improved Residential Construction was to compare a ductless heat pump (DHP) hybrid system (DHP in common area/electric resistance [ER] in bedrooms) to an all-electric zonal ER system in high-performance single-family affordable housing. This effort included assessing the costs and benefits of a DHP/ER hybrid system located in the main living area to offset the primary heating demand of zonal ER heaters in the bedroom zones and comparing these findings to data from of new affordable single-family housing in Washington State. This report includes: (1) Measured indoor and outdoor temperatures and relative humidity (RH) in the homes. (2) Field testing results of heating, ventilating, and air-conditioning equipment; ventilation system airflows; building envelope tightness; lighting, appliance, and other input data required for preliminary Building Energy Optimization (BEopt) modeling; and ENERGY STAR field verification (3) BEopt modeling results compared to measured energy use. (4) A comparison of the space heat energy consumption of a DHP/ER hybrid heating system and a traditional zonal ER heating system installed in the same home. This comparison is made by implementing a series of weekly "flip-flop tests" (referred to here as "switchback" tests per TPU) to compare space heating, temperature, and RH in zonal ER heating mode with a DHP/ER mode as discussed in the Building America Test Plan (Lubliner 2010a). (5) Cost data from HFH and other sources related to building efficiency measures focusing on the DHP/ER hybrid heating system. (6) An evaluation of the thermal performance and cost benefit of DHP/ER hybrid heating systems in these high-performance homes employing life cycle cost analysis for energy code policy and monthly cash flow analysis of HFH homeowners. (7) Post-monitoring occupant survey results. The report also provides the following stakeholder findings and recommendations: (1) DHP single-head systems at The Woods are cost-effective to new homebuyers of these high-performance all-electric homes. (2) Stakeholder education is needed on design, inspection, and commissioning; documentation is needed for heat recovery ventilation (HRV) and from ENERGY STAR builders, verifiers, and inspectors to help ensure that the houses meet the goal of "build tight, ventilate right." (3) A code gap in inspection and enforcement was identified that should be addressed by: (3a) Improving the fire marshal's approach to sprinkler attic piping freeze protection; (3b) Improving the maintenance of ceiling insulation continuity; and (3c) Educating the local building inspector on attic insulation inspection concerns that allow for maximizing design improveme...

affordable housing↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

Analysis of radiant cooling system integrated with cooling tower for composite climatic conditions

Increased demand for cooling leads to consumption of a significant amount of energy by heating, ventilation, and air conditioning (HVAC) systems in buildings. Building envelope acts as a thermal barrier and plays a significant role in improving building energy efficiency. Radiant cooling systems often utilize building structure in the form of thermal storage and provide thermal comfort. The radiant cooling system has the potential of saving peak power in the buildings. In present study experimental and a simulation study is performed for chiller and cooling tower integrated chilled ceiling radiant cooling system for chilled water source and a parallel dedicated outdoor air system (DOAS) is used for providing latent load and fresh air requirements of the zone. Cooling tower based radiant cooling system is compared with a chiller-based radiant cooling system for achieving annual energy saving. Experiments are conducted for the chiller and cooling tower operated radiant cooling system. Based on experimental data, whole building simulation models of both cooling tower and chiller-based systems were calibrated. For both the simulation model of chiller and cooling tower operated radiant cooling system simulation were carried out for round the year. The annual simulation results show that the cooling tower operated radiant cooling system saves 14% energy as compared to the chilled water operated radiating cooling system.

Srivastava, Prateek↗

The Impact of Surficial Biochar Treatment on Acute H2S Emissions during Swine Manure Agitation before Pump-Out: Proof-of-the-Concept

Acute releases of hydrogen sulfide (H2S) are of serious concern in agriculture, especially when farmers agitate manure to empty storage pits before land application. Agitation can cause the release of dangerously high H2S concentrations, resulting in human and animal fatalities. To date, there is no proven technology to mitigate these short-term releases of toxic gas from manure. In our previous research, we have shown that biochar, a highly porous carbonaceous material, can float on manure and mitigate gaseous emissions over extended periods (days–weeks). In this research, we aim to test the hypothesis that biochar can mitigate H2S emissions over short periods (minutes–hours) during and shortly after manure agitation. The objective was to conduct proof-of-the-concept experiments simulating the treatment of agitated manure. Two biochars, highly alkaline and porous (HAP, pH 9.2) made from corn stover and red oak (RO, pH 7.5), were tested. Three scenarios (setups): Control (no biochar), 6 mm, and 12 mm thick layers of biochar were surficially-applied to the manure. Each setup experienced 3 min of manure agitation. Real-time concentrations of H2S were measured immediately before, during, and after agitation until the concentration returned to the initial state. The results were compared with those of the Control using the following three metrics: (1) the maximum (peak) flux, (2) total emission from the start of agitation until the concentration stabilized, and (3) the total emission during the 3 min of agitation. The Gompertz’s model for determination of the cumulative H2S emission kinetics was developed. Here, 12 mm HAP biochar treatment reduced the peak (1) by 42.5% (p = 0.125), reduced overall total emission (2) by 17.9% (p = 0.290), and significantly reduced the total emission during 3 min agitation (3) by 70.4%. Further, 6 mm HAP treatment reduced the peak (1) by 60.6%, and significantly reduced overall (2) and 3 min agitation’s (3) total emission by 64.4% and 66.6%, respectively. Moreover, 12 mm RO biochar treatment reduced the peak (1) by 23.6%, and significantly reduced overall (2) and 3 min total (3) emission by 39.3% and 62.4%, respectively. Finally, 6 mm RO treatment significantly reduced the peak (1) by 63%, overall total emission (2) by 84.7%, and total emission during 3 min agitation (3) by 67.4%. Biochar treatments have the potential to reduce the risk of inhalation exposure to H2S. Both 6 and 12 mm biochar treatments reduced the peak H2S concentrations below the General Industrial Peak Limit (OSHA PEL, 50 ppm). The 6 mm biochar treatments reduced the H2S concentrations below the General Industry Ceiling Limit (OSHA PEL, 20 ppm). Research scaling up to larger manure volumes and longer agitation is warranted.

Chen, Baitong (ORCID:0000000266071253)↗

Emerging Zero-Standby Solutions for Miscellaneous Electric Loads and the Internet of Things

Despite technical advances in efficiency, devices in standby continue to consume up to 16% of residential electricity. Finding practical, cost-effective reductions is difficult. While the per-unit power consumption has fallen, the number of units continuously drawing power continues to grow. This work reviews a family of technologies that can eliminate standby consumption in many types of electrical plug loads. It also investigates several solutions in detail and develops prototypes. First, burst mode and sleep transistors are established as building blocks for zero-standby solutions. This work then studies the application of two types of wake-up signals. The first is from an optical transmission, and is applicable to remote-controlled devices with a line-of-sight activation, such as set-top boxes, ceiling fans, and motorized curtains. The second is from a wake-up radio, and is applicable to any wireless products. No single technology will address all standby power situations; however, these emerging solutions appear to have broad applicability to save standby energy in miscellaneous plug loads.

42 ENGINEERING↗

Energy Efficiency Package for Tenant Fit-Out: Laboratory Testing and Validation of Energy Savings and Indoor Environmental Quality

Approximately 40% of the total U.S. office floor space of 1.5 billion sq.m (16 billion sq.ft.) is leased space occupied by tenants. Tenant fit-out presents a key opportunity to incorporate energy efficiency within the real estate business cycle. We designed a package of energy efficiency measures tailored to the scope of a tenant fit-out. This tenant fit-out package (TFP) includes advanced lighting and heating, ventilating and air-conditioning (HVAC) controls as core measures, with ceiling fans, automated shading, and plug load controls as additional optional measures. We conducted laboratory testing of six configurations of the package to evaluate energy savings, indoor environmental quality, and identify installation, commissioning, and operational issues. Combined savings for HVAC, lighting, and plug loads ranged from 33–40%. Lighting savings ranged from 69–83%, and HVAC savings from 20–40%. The laboratory testing also revealed some minor but tractable challenges with installation and commissioning of HVAC controls. Overall, the results demonstrate that significant savings can be realized in existing office buildings by incorporating relatively low-risk, proven measures at the time of a tenant fit-out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study

We did energy efficient retrofits for the Indiana University Purdue University—Indianapolis Health Science Building using the eQuest energy software. The current dual-fan dual-duct (DFDD) system is 41 years old and has a higher energy utilization index (EUI) than the national average for similar building types. The baseline model with the DFDD system was compared with the actual electrical consumption. Then, two energy efficiency measures (EEMs) were applied to the model. The first EEM was ‘DFDD system with chilled water and steam heating,’ and the second EEM was ‘single-duct variable air volume (VAV) with chilled water and electric reheat.’ After comparative simulations and analyses, it was determined that the ‘single duct VAV with chilled water and electric reheat’ was the most energy efficient and saved 28% in utility costs. The recommendation given to the facility services was to change the current DFDD system to the single-duct VAV system. The single-duct VAV system will save energy and create additional space above the ceiling after the heating duct is removed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biodesign Research to Advance the Principles and Applications of Biosystems Design

Over the course of civilization, humans have increasingly expanded their freedom to live a better life. In comparison with the primitive society, our modern society has many more choices of life-supporting resources, such as year-round food supply, permanent shelters, diverse energy sources, and effective preventive and curing medicine. However, our society is currently still heavily relying on the resources provided by Mother Nature, which cannot meet the future global needs in terms of both quantity and quality under the pressure of population growth, natural resource reduction, and environmental deterioration. For example, the food sources originating from plants, animals, or microbes do not have the nutrition balance for optimal human health. Climate change and environmental deterioration threaten the food security. Increasingly, infectious diseases (e.g., HIV/AIDS), genetic diseases (e.g., cancer), and improper lifestyle-related disorders (e.g., obesity) become more prevalent and remain challenging to be prevented, controlled, and cured. Conventional medical technologies and modern medicine development are also meeting the ceiling. Antibiotic resistance is threatening the health of humans, animals, and environment. As the human lifespan continues to increase, aging-related diseases, disorders, and poor life quality are becoming global challenges. Plants, animals, and microbes in nature have evolved as part of our Earth ecosystem, not for benefiting humans. Even though humans have put forth tremendous efforts to domesticate plants, animals, and microbes based on random/induced mutations, hybridization, and limited genetic modifications via biological engineering, the improved food and industrial crop plants, animals, and microbial strains are still far from optimized for meeting the human needs. In other words, natural evolution and domestication in plants, animals, and microbes are tinkering processes and therefore cannot meet the ever-exploding population on the one hand and the unending appetite for living better quality life on the other. One promising strategy for solving these global challenges is to employ revolutionary biosystems design (also called biodesign), which is defined as predictable modification of existing organisms or creation of new organisms using rational engineering or automated design based on the theory and principles of biosystems design.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation of Monte Carlo Transport in the General Relativistic SpEC Code

Neutrino transport and neutrino-matter interactions are known to play an important role in the evolution of neutron star mergers and of their post-merger remnants. Neutrinos cool remnants, drive post-merger winds, and deposit energy in the low-density polar regions where relativistic jets may eventually form. Neutrinos also modify the composition of the ejected material, impacting the outcome of nucleosynthesis in merger outflows and the properties of the optical/infrared transients that they power (kilonovae). So far, merger simulations have largely relied on approximate treatments of the neutrinos (leakage, moments) that simplify the equations of radiation transport in a way that makes simulations more affordable but also introduces unquantifiable errors in the results. To improve on these methods, we recently published a first simulation of neutron star mergers using a low-cost Monte Carlo algorithm for neutrino radiation transport. Our transport code limits costs in optically thick regions by placing a hard ceiling on the value of the absorption opacity of the fluid, yet all approximations made within the code are designed to vanish in the limit of infinite numerical resolution. We provide here an in-depth description of this algorithm, of its implementation in the SpEC merger code, and of the expected impact of our approximations in optically thick regions. We argue that the last is a subdominant source of error at the accuracy reached by current simulations and for the interactions currently included in our code. We also provide tests of the most important features of this code.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-Semester Mentoring and GPA Trajectories in SPINS: A Longitudinal Program Evaluation of STEM Scholars

This exploratory longitudinal program evaluation examined GPA trajectories among 14 STEM scholars participating in the Scholarly Partnership in Nuclear Security (SPINS) mentoring program at an HBCU. Using de-identified administrative data (37 scholar-semester observations), the study compared baseline and latest term GPAs anchored to each scholar’s first funded semester. A Wilcoxon signed-rank test was used to assess within-student change. Mean GPA increased modestly from 3.46 (SD = 0.30) at baseline to 3.61 (SD = 0.33) at the latest observed semester, with 12 of 14 scholars (85.7%) showing net improvement (median change = +0.12). The Wilcoxon signed-rank test indicated a statistically significant positive shift (W = 18, p = 0.030). However, scholars entered the program with a high baseline GPA, and ceiling effects were evident for several participants. Grounded in Social Cognitive Career Theory, findings suggest that multi-semester participation in SPINS is associated with GPA stability and modest improvement in an already high-performing cohort. Results should be interpreted cautiously given the small sample size and single-group design. The study highlights the value of sustained, culturally responsive mentoring at an HBCU while underscoring the need for larger evaluations with comparison cohorts and broader psychosocial outcomes. An evidence-informed mentoring framework is proposed to strengthen multi-semester support.

42 ENGINEERING↗

Dataset: Occupancy Detection, Tracking, and Estimation Using a Vertically Mounted Depth Sensor

Occupancy detection, tracking, and estimation has a wide range of applications including improving building energy efficiency, safety, and security of the occupants. As depth sensors are getting cheaper, they offer a viable solution to estimate occupancy accurately in a non-privacy invasive manner. Even though there are publicly available depth datasets, they do not consider placing the sensor in the ceiling looking downwards to estimate occupancy. We deployed four Kinect for XBOX One in four CMU classrooms and conference rooms for a period of four weeks in 2017 and collected over 6 TB of depth data. We annotate this huge dataset by labelling bounding boxes around occupants and release the annotated dataset.

47 OTHER INSTRUMENTATION↗

TSI composite images merged cloud fraction product for shallow cumulus cases (tsiQLtable)

This data product provides a visual "quicklook" at passive (total sky imager--TSI) and active (ceilometer--CEIL, micropulse lidar--MPL, millimeter wave cloud radar--MMCR, Ka ARM Zenith Radar--KAZR) observations of cloud amount obtained from TSI images at at the ARM SGP Central Facility site during times with shallow cumulus clouds. A full description of the data and methods can be found in Riley et al. (2019).

54 ENVIRONMENTAL SCIENCES↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.1), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Scanning photometer system automatically determines atmospheric layer height

Two photometers, placed a given distance apart, determine the height of nonuniform luminous layers in a synchronous manner. Photometer outputs are correlated by a simple analog correlation computer to automatically give the luminous layer height. This system is used to determine visibility ceilings at airports.

Wolff, M.↗

Probabilistic approach to long range planning of manpower

Publication presents a total long range planning model for project oriented organizations. The total model consists of planning systems which originate - /1/ at the project level and consolidate into an overall plan, and /2/ from a budetary ceiling and allocate to the individual projects. Analysis of /1/ and /2/ is provided for management decision making.

Lejk, R. A.↗

The Eole weather satellite

Eole experiment - weather satellite used to follow ceiling balloons with radioelectric responder

METEOROLOGICAL SATELLITE↗