Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Liquid laser cavities

Liquid laser cavities have plenum chambers at the ends of the capillary cell which are terminated in transparent optical flats. By use of these cavities, several new europium chelates and a terbium chelate can provide laser action in solution at room temperature.

Bjorklund, S.↗

A mini-cavity probe reactor.

The mini-cavity reactor is a rocket engine concept which combines the high specific impulse from a central gaseous fueled cavity (0.6 m diam) and NERVA type fuel elements in a driver region that is external to a moderator-reflector zone to produce a compact light weight reactor. The overall dimension including a pressure vessel that is located outside of the spherical reactor is approximately 1.21 m in diameter. Specific impulses up to 2000 sec are obtainable for 220 to 890 N of thrust with pressures less than 1000 atm. Powerplant weights including a radiator for disposing of the power in the driver region are between 4600 and 32,000 kg - less than payloads of the shuttle. This reactor could also be used as a test reactor for gas-core, MHD, breeding and materials research.

Hyland, R. E.↗

A cavity type absorption cell for double resonance microwave spectroscopy.

Description of an experimental dual resonant cavity absorption cell for observing microwave spectroscopic double-resonance effects. The device is composed of two Fabry-Perot interferometers excited by independent microwave sources and mounted at right angles in a suitable vacuum enclosure. The pumping transition is modulated by one source and the modulation induced on the rf absorption in the orthogonal cavity is detected.

Lee, M. C.↗

Active cavity radiometer.

The active cavity radiometer (ACR) is a pyrheliometer that accurately defines the absolute radiation scale. The physics of the pyrheliometric method and the ACR approach to this method are presented in detail. A mathematical abstraction of the method is generated through a quasi-equilibrium analysis of the power balance of the ACR's cavity detector. An error analysis is carried out on the quasi-equilibrium equation to determine the uncertainties of ACR measurements relative to the absolute radiation scale. The uncertainty of ACR measurements as a function of irradiance level is presented in graphical form.

Willson, R. C.↗

Spectral line absorption measurement using optical cavities.

A simple technique using a conventional gas laser with spherical mirrors having identical radii of curvature in the nonoscillating regime for spectral line absorption measurements is described and applications for laser work are suggested. The theory of the measurement carried out in the geometrical optical approach for Doppler-broadened lines was checked experimentally and conditions are specified for which measurement inaccuracies of the order of 1% for the peak value of the line absorption coefficient can be obtained. Since the device provides a fine adjustment of the cavity losses, formation of the diffraction modes could be observed in the preoscillating regime of the optical cavity.

Blanaru, D. L.↗

Aerodynamic heating and loading within large open cavities in cone and cone-cylinder-flare models at Mach 6.7

The aerodynamic heating and loading distributions within large cavities exposed by surface openings to hypersonic flow were determined in the 8-foot high-temperature structures tunnel. Cone and cone-cylinder-flare models with cavities having regular and irregular surface-opening shapes were aerothermally tested at various angles of attack up to 30 deg. Tests were conducted at a Mach number of 6.7, a total temperature of 1800 K, a dynamic pressure of 80 kPa, and a stream unit Reynolds number of 6,000,000 per meter. The results showed that the heating rates at internal reattachment were generally lower but of the same order as the corresponding external heating rates; however, other internal heating rates were an order of magnitude lower. The internal flow showed characteristics of being funneled into jets or being dispersed dependent upon the internal surface contour.

Hunt, R. L.↗

Acoustic phenomena of open cavity airborne Cassegrainian telescopes

A series of large scale wind tunnel experiments were conducted on a gimbal mounted Cassegrainian telescope enclosed in a shroud with various aerodynamic fairings. The optical aperture was open to the airstream, resulting in acoustic inputs to the telescope. Resonance was shown to be dependent on free stream Mach number, internal cavity and external fairing geometry, and the angle of the plane of the opening relative to the free stream direction. Configurations were found which caused low noise and low unsteady internal loads at the expense of decreased view angle. Air injection over the cavity aided in reducing acoustic resonance.

Van Kuren, J. T.↗

The stability of motion of satellites with cavities partially filled with liquid

The purpose of the present paper is to determine rigorously the effect of viscous dissipation on the stability and time-dependent motion of a spinning rigid body with a spherical cavity partially filled with liquid. The cavity is such that its center does not lie on the body axis of rotation. The work includes the problem formulation, consisting of the boundary-value problem for the liquid and moment equations for the entire system. Because of large Reynold's numbers involved, viscosity effects are negligible everywhere except for a thin boundary layer near the wetted surface. Using a boundary-layer analysis, the liquid problem is reduced to the solution of the inviscid equations subject to modified boundary conditions.

Nayfeh, A. H.↗

Effects of inlet treatment location and treatment cavity depth on compressor noise

The ability of acoustic liners to reduce compressor noise inside and in front of an inlet was studied. An axial flow research compressor and a specially designed inlet were used inside an anechoic chamber. Acoustic and performance data were obtained for a range of inlet treatment locations and cavity depths to determine their effects on inlet noise over a range of blade passing frequencies. The greatest noise reductions in front of the inlet were obtained with acoustic treatment located close to the compressor and backed with the deepest cavities tested. Inside the inlet the maximum noise level reductions were obtained in the area of the treatment regardless of treatment location. No appreciable losses in compressor performance were measured.

Clark, L. R.↗

Active-cavity radiometer/pyroheliometer

Device, using specular black cavity heater, temperature sensors, and electronics and electrodeposited cavity/thermal impedance structures, can achieve + or - 0.1 percent long-term absolute uncertainty at solar constant level. Dual-cavity configuration helps decrease sensitivity for heat-sink temperature drift.

Willson, R. C.↗

Space shuttle cavity assessment test program

In order to obtain basic radiation properties of the radiator/payload bay door cavity, three tests were conducted on a full-size structural simulator of the cavity. There were three tests conducted: (1) CATA used for determination of exchange factors, absorbed solar flux, and door covering influences, (2) quartz lamp array calibrated to provide IR flux distribution on CATA, and (3) retest with radiometer array for background flux measurement.

Scheps, P. B.↗

Common-cavity pumped laser

Two lasers linked by dichroic coupler are packaged in single cavity. Resulting system is more compact, efficient, and durable than conventional two-cavity lasers. Such instruments (portable pumped lasers) are needed for spectroscopy in plasma diagnostics in atmospheric research, and in radar-like devices for seeing through dense fog or smoke.

Koepf, G. A.↗

Accurate solar 'constant' determinations by cavity pyrheliometers

Total solar irradiance was observed outside the earth's atmosphere by three types of absolute cavity pyrheliometer in a June 1976 sounding-rocket experiment. The 1367-W/sq m average solar 'constant' result is uncertain by less than + or - 0.5%, the most accurate determination to date. Nearly simultaneous observations by the Nimbus 6 earth-radiation-budget total-irradiance detector of 1389-W/sq m exceeded the rocket result by 1.6%. These recent results are discussed in the context of a summary of solar-constant determinations made above the troposphere by cavity pyrheliometers.

Willson, R. C.↗