Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

Advancements in Constitutive Model Calibration: Leveraging the Power of Full‐Field DIC Measurements and In Situ Load Path Selection for Reliable Parameter Inference

Accurate material characterization and model calibration are essential for computationally supported high-consequence engineering decisions. Historically, characterization and calibration methods (1) use simplified test specimen geometries and global data, (2) cannot guarantee that sufficient characterization data are collected for a specific model of interest, (3) use deterministic methods that provide best-fit parameter values with no uncertainty quantification, and (4) are sequential, inflexible, and time-consuming. This work brings together several recent advancements into an improved workflow called interlaced characterization and calibration (ICC) that advances the state-of-the-art in constitutive model calibration. The ICC paradigm (1) employs tools to efficiently use full-field data to calibrate high-fidelity material models, (2) aligns the data needed with the data collected by adopting an optimal experimental design protocol, (3) quantifies parameter uncertainty through Bayesian inference and (4) incorporates these advancements into a quasi real-time feedback loop. The ICC framework is demonstrated here on the calibration of a material model using simulated full-field data for an aluminium cruciform specimen being deformed biaxially. The cruciform is actively driven through the myopically preferred load path using Bayesian optimal experimental design, which selects load steps that yield the maximum expected information gain (EIG). Principal component analysis (PCA) is performed on the model predictions of full-field displacements, and fast surrogate models are built to approximate the input-output relationships of the expensive finite element model. Furthermore, the tools developed and demonstrated here show that high-fidelity constitutive models can be efficiently and reliably calibrated with quantified uncertainty, thus supporting credible decision-making and potentially increasing the agility of solid mechanics modelling by enabling utilization of computational simulations at earlier stages of the design cycle.

Bayesian optimal experimental design↗

Validation Metrics for Fixed Effects and Mixed-Effects Calibration

The modern scientific process often involves the development of a predictive computational model. To improve its accuracy, a computational model can be calibrated to a set of experimental data. A variety of validation metrics can be used to quantify this process. Some of these metrics have direct physical interpretations and a history of use, while others, especially those for probabilistic data, are more difficult to interpret. In this work, a variety of validation metrics are used to quantify the accuracy of different calibration methods. Frequentist and Bayesian perspectives are used with both fixed effects and mixed-effects statistical models. Through a quantitative comparison of the resulting distributions, the most accurate calibration method can be selected. Two examples are included which compare the results of various validation metrics for different calibration methods. It is quantitatively shown that, in the presence of significant laboratory biases, a fixed effects calibration is significantly less accurate than a mixed-effects calibration. This is because the mixed-effects statistical model better characterizes the underlying parameter distributions than the fixed effects model. The results suggest that validation metrics can be used to select the most accurate calibration model for a particular empirical model with corresponding experimental data.

97 MATHEMATICS AND COMPUTING↗

Characterization and Valuation of the Uncertainty of Calibrated Parameters in Microsimulation Decision Models

We evaluated the implications of different approaches to characterize the uncertainty of calibrated parameters of microsimulation decision models (DMs) and quantified the value of such uncertainty in decision making. We calibrated the natural history model of CRC to simulated epidemiological data with different degrees of uncertainty and obtained the joint posterior distribution of the parameters using a Bayesian approach. We conducted a probabilistic sensitivity analysis (PSA) on all the model parameters with different characterizations of the uncertainty of the calibrated parameters. We estimated the value of uncertainty of the various characterizations with a value of information analysis. We conducted all analyses using high-performance computing resources running the Extreme-scale Model Exploration with Swift (EMEWS) framework. The posterior distribution had a high correlation among some parameters. The parameters of the Weibull hazard function for the age of onset of adenomas had the highest posterior correlation of -0.958. When comparing full posterior distributions and the maximum-a-posteriori estimate of the calibrated parameters, there is little difference in the spread of the distribution of the CEA outcomes with a similar expected value of perfect information (EVPI) of $\$$653 and $\$$685, respectively, at a willingness-to-pay (WTP) threshold of $\$$66,000 per quality-adjusted life year (QALY). Ignoring correlation on the calibrated parameters’ posterior distribution produced the broadest distribution of CEA outcomes and the highest EVPI of $\$$809 at the same WTP threshold. Different characterizations of the uncertainty of calibrated parameters affect the expected value of eliminating parametric uncertainty on the CEA. Ignoring inherent correlation among calibrated parameters on a PSA overestimates the value of uncertainty.

97 MATHEMATICS AND COMPUTING↗

Comparative Analysis of Thrombin Calibration Algorithms and Correction for Thrombin-α2macroglobulin Activity

Background: The thrombin generation (TG) test is useful for characterizing global hemostasis potential, but fluorescence substrate artifacts, such as thrombin-α2macroglobulin (T-α2MG) signal, inner filter effect (IFE), substrate consumption, and calibration algorithms have been suggested as sources of intra- and inter-laboratory variance, which may limit its clinical utility. Methods: Effects of internal vs. external normalization, IFE and T-α2MG on TG curves in normal plasma supplemented with coagulation factors, thrombomodulin, and tissue factor were studied using the Calibrated Automated Thrombinography (CAT; Diagnostica Stago, Parsippany, NJ, USA) and in-house software. Results: The various calibration methods demonstrated no significant difference in producing TG curves, nor increased the robustness of the TG assay. Several TG parameters, including thrombin peak height (TPH), produced from internal linear calibration did not differ significantly from uncalibrated TG parameters. Further, TPH values from internal linear and nonlinear calibration with or without T-α2MG correction correlated well with TPH from external calibration. Higher coefficients of variation (CVs) for TPH values were observed in both platelet-free and platelet-rich plasma with added thrombomodulin. Conclusions: Our work suggests minimal differences between distinct computational approaches toward calibrating and correcting fluorescence signals into TG levels, with most samples returning similar or equivalent TPH results.

59 BASIC BIOLOGICAL SCIENCES↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Synthesis of VIIRS Solar and Lunar Calibrations

The NASA VIIRS Ocean Science Team (VOST) has developed two independent calibrations of the SNPP VIIRS moderate resolution reflective solar bands using solar diffuser and lunar observations through June 2013. Fits to the solar calibration time series show mean residuals per band of 0.078-0.10%. There are apparent residual lunar libration correlations in the lunar calibration time series that are not accounted for by the ROLO photometric model of the Moon. Fits to the lunar time series that account for residual librations show mean residuals per band of 0.071-0.17%. Comparison of the solar and lunar time series shows that the relative differences in the two calibrations are 0.12-0.31%. Relative uncertainties in the VIIRS solar and lunar calibration time series are comparable to those achieved for SeaWiFS, Aqua MODIS, and Terra MODIS. Intercomparison of the VIIRS lunar time series with those from SeaWiFS, Aqua MODIS, and Terra MODIS shows that the scatter in the VIIRS lunar observations is consistent with that observed for the heritage instruments. Based on these analyses, the VOST has derived a calibration lookup table for VIIRS ocean color data based on fits to the solar calibration time series.

Calibrations↗

Assessment of New Load Schedules for the Machine Calibration of a Force Balance

New load schedules for the machine calibration of a six-component force balance are currently being developed and evaluated at the NASA Ames Balance Calibration Laboratory. One of the proposed load schedules is discussed in the paper. It has a total of 2082 points that are distributed across 16 load series. Several criteria were applied to define the load schedule. It was decided, for example, to specify the calibration load set in force balance format as this approach greatly simplifies the definition of the lower and upper bounds of the load schedule. In addition, all loads are assumed to be applied in a calibration machine by using the one-factor-at-a-time approach. At first, all single-component loads are applied in six load series. Then, three two-component load series are applied. They consist of the load pairs (N1, N2), (S1, S2), and (RM, AF). Afterwards, four three-component load series are applied. They consist of the combinations (N1, N2, AF), (S1, S2, AF), (N1, N2, RM), and (S1, S2, RM). In the next step, one four-component load series is applied. It is the load combination (N1, N2, S1, S2). Finally, two five-component load series are applied. They are the load combination (N1, N2, S1, S2, AF) and (N1, N2, S1, S2, RM). The maximum difference between loads of two subsequent data points of the load schedule is limited to 33 % of capacity. This constraint helps avoid unwanted load "jumps" in the load schedule that can have a negative impact on the performance of a calibration machine. Only loadings of the single- and two-component load series are loaded to 100 % of capacity. This approach was selected because it keeps the total number of calibration points to a reasonable limit while still allowing for the application of some of the more complex load combinations. Data from two of NASA's force balances is used to illustrate important characteristics of the proposed 2082-point calibration load schedule.

wind tunnel testing↗

SIM-Lite Mission Spectral Calibration Sensitivities and Refinements

SIM-Lite missions will perform astrometry at microarcsecond accuracy using star light interferometry. For typical baselines that are shorter than 10 meters, this requires to measure optical path difference (OPD) accurate to tens of picometers calling for highly accurate calibration. A major challenge is to calibrate the star spectral dependency in fringe measurements -- the spectral calibration. Previously, we have developed a spectral calibration and estimation scheme achieving picometer level accuracy. In this paper, we present the improvements regarding the application of this scheme from sensitivity studies. Data from the SIM Spectral Calibration Development Unit (SCDU) test facility shows that the fringe OPD is very sensitive to pointings of both beams from the two arms of the interferometer. This sensitivity coupled with a systematic pointing error provides a mechanism to explain the bias changes in 2007. Improving system alignment can effectively reduce this sensitivity and thus errors due to pointing errors. Modeling this sensitivity can lead to further improvement in data processing. We then investigate the sensitivity to a model parameter, the bandwidth used in the fringe model, which presents an interesting trade between systematic and random errors. Finally we show the mitigation of calibration errors due to system drifts by interpolating instrument calibrations. These improvements enable us to use SCDU data to demonstrate that SIM-Lite missions can meet the 1pm noise floor requirement for detecting earth-like exoplanets.

wave front aberration↗

Laser Calibration of an Impact Disdrometer

A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved.

calibration↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Upgrade

Current performance and existing problems in SMAP radiometer L1B_TB version 3 data product are described. The post-launch calibration algorithm has been updated by calibrating the three calibration parameters (the equivalent noise temperature of the noise diode, the offset of the reference load, and the antenna gain) jointly by using the global ocean and CS with both 110o and 180o pitch maneuvers after the reflector emissivity is calibrated. The results show that both calibration drift during eclipse season and bias over CS are removed. The RMSDs of the calibration drift over both the global ocean and CS are less than 0.1 K, and the goals of the calibration algorithm upgrade are achieved for coming L1B_TB version 4 data release.

Validation↗

The Inter-Calibration of the DSCOVR EPIC Imager 2 with Aqua-MODIS and NPP-VIIRS

The Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) continuously observes the illuminated disk from the Lagrange-1 point. The EPIC sensor was designed to monitor the diurnal variation of ozone, clouds, aerosols, and vegetation, especially those features that benefit from observation near-backscatter conditions. The EPIC sensor does not contain any onboard calibration systems. This study describes the inter-calibration of EPIC channels 5 (0.44 μm), 6 (0.55 μm), 7 (0.68 μm), and 10 (0.78 μm) with respect to Aqua-MODIS and NPP-VIIRS. The calibration is transferred using coincident ray-matched reflectance pairs over all-sky tropical ocean (ATO) and deep convective cloud (DCC) targets. A robust and automated image-alignment technique based on feature matching was formulated to improve the navigation quality of the EPIC images. The EPIC V02 dataset exhibits improved navigation over V01. Because the visible channels display similar spatial features, a single visible channel can be used to co-register the remaining visible bands. The VIIRS-referenced EPIC ATO and DCC ray-matched calibration coefficients are within 0.3%. The EPIC four-year calibration trends based on VIIRS are within 0.15%/year. The MODIS-based EPIC calibration coefficients were compared against the Geogdzhayev and Marshak 2018 published calibration coefficients and are found to be within 1.6%.

DSCOVR↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

NOAA-20 VIIRS Reflective Solar bands on-Orbit Calibration Using a Hybrid Approach

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) has been in orbit for more than two and a half years. VIIRS has 22 bands, among which 14 are reflective solar bands (RSBs) covering a spectral range from 0.41 to 2.25 μm. The RSBs are calibrated on-orbit using an onboard solar diffuser (SD), on-orbit degradation of which is tracked by an onboard SD stability monitor (SDSM). NOAA-20 VIIRS is also scheduled to view the Moon approximately monthly and the lunar observations are used to track the RSB on-orbit changes as well. Both SD and lunar calibration results for the RSBs are shown and it is demonstrated that the two sets of the calibration coefficients diverge with time, especially at short wavelengths. The divergence is due to the non-uniformity of the SD degradation, which results in a long-term bias in the calibration coefficients derived from the SD calibration. A hybrid method, which properly combines the SD and lunar calibration results, is applied to generate the RSB calibration coefficients as has been done for SNPP VIIRS RSBs. The hybrid results have both the accuracy and frequency and ensure the high quality of the VIIRS sensor data records (SDR).

Calibration↗

SNPP VIIRS Day Night Band: Ten Years of On-Orbit Calibration and Performance

Aboard the polar-orbiting SNPP satellite, the VIIRS instrument has been in operation since launch in October 2011. It is a visible and infrared radiometer with a unique panchromatic channel capability designated as a day-night band (DNB). This channel covers wavelengths from 0.5 to 0.9 µm and is designed with a near-constant spatial resolution for Earth observations 24 h a day. The DNB operates at 3 gain stages (low, middle, and high) to cover a large dynamic range. An onboard solar diffuser (SD) is used for calibration in the low gain stage, and to enable the derivation of gain ratios between the different stages. In this paper, we present the SNPP VIIRS DNB calibration performed by the NASA VIIRS characterization support team (VCST). The DNB calibration algorithms are described to generate the calibration coefficient look up tables (LUTs) for the latest NASA Level 1B Collection 2 products. We provide an evaluation of DNB on-orbit calibration performance. This activity supports the NASA Earth science community by delivering consistent VIIRS sensor data products via the Land Science Investigator-led Processing Systems, including the SD degradation applied for DNB calibrations in detector gain and gain ratio trending. The DNB stray light contamination and its correction are highlighted. Performance validations are presented using comparisons to the calibration methods employed by NOAA’s operational Interface Data Processing Segment. Further work on stray light corrections is also discussed.

VIIRS↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

An empirical calibration of the serpentine-water oxygen isotope fractionation at T = 25–100°C

The ability to precisely constrain the physical–chemical conditions of serpentinization, such as temperature and fluid source, is limited by the accuracy of calibrations for oxygen isotope fractionation between serpentine and water – i.e., 1000 lnα( serpentine-water ) – which disagree by up to 20‰ when extrapolated to T<200°C. In this study, we present a new empirical calibration of 1000 lnα( serpentine-water ) aiming to improve applications of oxygen isotope geochemistry to very low-T serpentinization (T<100°C). We used the high-spatial resolution capabilities of Secondary Ion Mass Spectrometry (SIMS) to analyze oxygen isotope ratios in mineral pairs of calcite + serpentine, quartz + serpentine and talc + serpentine co-crystallized at scales≤50μm in six serpentinite samples from the Samail ophiolite (Oman). SIMS analysis shows that the mineral pairs are relatively homogenous in oxygen isotope ratios with variability in δ 18 O values ≤2‰ (2s). Clumped isotope thermometry and petrological constraints indicate crystallization temperatures from 25 to 100°C for the investigated samples. These independent constraints on temperature allowed us to derive 1000 lnα( serpentine-water ) by combining Δ 18 O( quartz-serpentine ), Δ 18 O( talc-serpentine ) and Δ 18 O( calcite-serpentine ) measured by SIMS in the investigated samples with Δ 18 O( quartz-water ), Δ 18 O( talc-water ) and Δ 18 O( calcite-water ) calibrations available in the literature. Our empirical calibration of 1000 lnα( serpentine-water ) = 1.04±0.20 (2SE) × 10 6 /T 2 (T in K), from T = 25 to 100°C, is within uncertainty of former high-temperature empirical calibrations extrapolated to T<100°C and matches experimental calibrations when extrapolated to T=250°C. In conclusion, the new serpentine-water calibration enables more accurate reconstructions of fluid-rock interactions occurring during low-temperature serpentinization processes in various tectonic settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗