Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Unofficial Road Building in the Amazon: Socioeconomic and Biophysical Explanations

Roads have manifold social and environmental impacts, including regional development, social conflicts and habitat fragmentation. 'Road ecology' has emerged as an approach to evaluate the various ecological and hydrological impacts of roads. This article aims to complement road ecology by examining the socio-spatial processes of road building itself. Focusing on the Brazilian Amazon, a heavily-studied context due to forest fragmentation by roads, the authors consider non-state social actors who build 'unofficial roads' for the purpose of gaining access to natural resources to support livelihoods and community development. They examine four case studies of roads with distinct histories in order to explain the socio-spatial processes behind road building in terms of profit maximization, land tenure claims, co-operative and conflictive political ecologies, and constraints as well as opportunities afforded by the biophysical environment. The study cases illustrate the need for a multi-pronged theoretical approach to understanding road building, and call for more attention to the role of non-state actors in unofficial road construction.

Perz, Stephen G.↗

Business Solutions Case Study: Marketing Zero Energy Homes: LifeStyle Homes, Melbourne, Florida

Building America research has shown that high-performance homes can potentially give builders an edge in the marketplace and can boost sales. But it doesn't happen automatically. It requires a tailored, easy to understand marketing campaign and sometimes a little flair. This case study highlights LifeStyle Homes’ successful marketing approach for their SunSmart home package, which has helped to boost sales for the company. SunSmart marketing includes a modified logo, weekly blog, social media, traditional advertising, website, and sales staff training. Marketing focuses on quality, durability, healthy indoor air, and energy efficiency with an emphasis on the surety of third-party verification and the scientific approach to developing the SunSmart package. With the introduction of SunSmart, LifeStyle began an early recovery, nearly doubling sales in 2010; SunSmart sales now exceed 300 homes, including more than 20 zero energy homes. Completed homes in 2014 far outpaced the national (19%) and southern census region (27%) recovery rates for the same period. As technology improves and evolves, this builder will continue to collaborate with Building America.

Advertising↗

New Carrollton Federal Building Lighting Retrofit Captures Cool Savings

Case study describes how the U.S. General Services Administration cut a $291,000 annual lighting electric bill to an estimated $53,500 by upgrading their fluorescent lighting to a new LED troffer lighting and controls system in the New Carrollton Federal Building in Lanham, Maryland. The lighting project yielded an 82% reduction in energy use and earned GSA two awards for exemplary performance from the Interior Lighting Campaign in 2016.

General Services Administration↗

Building Capacity to Use Earth Observations for Land Monitoring: A Synoptic Review of NASA DEVELOP’s Terrestrial Projects

The NASA DEVELOP Program addresses environmental and public policy issues through interdisciplinary research studies that apply the lens of Earth observations to decision making. The program builds capacity in both programmatic participants (e.g., students and recent graduates) and partner organizations (e.g., federal agencies and non-governmental organizations) to use and integrate Earth science information into environmental decision making. DEVELOP conducts 50-60 projects each year, with approximately three quarters of projects focusing on terrestrial-related topics such as monitoring and assessing land use/land change, vegetation health, agriculture, water resources, and urban development. This presentation will share the DEVELOP model for building capacity, highlight example project case studies, and share lessons learned working with a wide variety of partner organizations.

Capacity Building↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing Hydronic Systems in Multifamily Buildings

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution, and controls. The imbalance leads to tenant discomfort, higher energy use intensity, and inefficient building operation. This research, conducted by Building America team Partnership for Advanced Residential Retrofit, explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61°F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1°F to 15.5°F.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of UBEM: An Assessment of Bias in Urban Building Energy Modeling for Chicago

Residential and commercial buildings currently account for 30% of total global final energy consumption. Urban-scale building energy modeling (UBEM) can enable scalable investments and unlock building improvements by quantifying energy, demand, emissions, and cost reductions of specific measures or packages for building-specific technologies in large geographic regions. While the sophistication of UBEM data sources and technologies have increased dramatically in the past decade, there remains a knowledge gap for empirical validation and sources of bias between building-specific energy models and measured data at varying geographic scales.As UBEM continues to develop, systemic analysis of accuracy, bias, and limitations of the resulting models is necessary to inform best practices and move toward standardization. These are characterized for the Automatic Building Energy Modeling (AutoBEM) software suite with an initial case study involving metered electricity consumption data from 247,188 buildings in Chicago, Illinois, USA - averaged across years 2019-2021 - compared to the following datasets: (1) the AutoBEM-generated nation-scale Model America version 2 (MAv2) data for 596,064 buildings, (2) tax assessor data for 579,829 buildings, (3) tax assessor data filled with MAv2, and (4) 102 representative dynamic archetypes. The accuracy is reported for every building type and vintage combination, along with multiple sources of bias for unique building descriptors. The AutoBEM simulation workflow produced energy consumption estimates that closely match aggregated metered electricity consumption data for different types of buildings constructed during various time periods at the city scale - with initial normalized mean bias error of 10.9%, and 1.1% after removing outliers. Contribution of statistically significant factors including building type, land use, age, and size to variance in UBEM bias is quantified.

Garg, Ankur↗

Balancing Hydronic Systems in Multifamily Buildings

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Solutions Case Study: Marketing Zero Energy Homes: Tommy Williams Homes, Gainesville, Florida

Building America research has shown that high-performance homes can potentially give builders an edge in the marketplace and can boost sales, but it doesn't happen automatically. It requires a tailored, easy-to-understand marketing campaign, and sometimes a little flair. This case study highlights the successful marketing approach of Tommy Williams Homes, which devotes resources to advertising, targeted social media outlets and blogs, realtor education seminars, and groundbreaking and open house celebrations. As a result, in one community, 2013 property sales records show that TWH outsells the only other builder in the development at a higher price, with fewer days on the market.

Advertising↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

Case Study of The ARRA-Funded GSHP Demonstration at the Natural Sources Building, Montana Tech

Under the American Recovery and Reinvestment Act (ARRA), 26 ground source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects was proposed by Montana Tech of the University of Montana for a 56,000 sq ft, newly constructed, on-campus research facility – the Natural Resources Building (NRB) located in Butte, Montana. This demonstrated GSHP system consists of a 50 ton water-to-water heat pump and a closed-loop ground heat exchanger with two redundant 7.5 hp constant-speed pumps to use water in the nearby flooded mines as a heat source or heat sink. It works in conjunction with the originally installed steam HX and an air-cooled chiller to provide space heating and cooling. It is coupled with the existing hot water and chilled water piping in the building and operates in the heating or cooling mode based on the outdoor air temperature. The ground loop pumps operate in conjunction with the existing pumps in the building hot and chilled water loops for the operation of the heat pump unit. The goal of this demonstration project is to validate the technical and economic feasibility of the demonstrated commercial-scale GSHP system in the region, and illustrate the feasibility of using mine waters as the heat sink and source for GSHP systems. Should the demonstration prove satisfactory and feasible, it will encourage similar GSHP applications using mine water, thus help save energy and reduce carbon emissions. The actual performance of the system is analyzed with available measured data for January through July 2014. The annual energy performance is predicted and compared with a baseline scenario, with the heating and cooling provided by the originally designed systems. The comparison is made in terms of energy savings, operating cost savings, cost-effectiveness, and environmental benefits. Finally, limitations in conducting the analysis are identified and recommendations for improvement in the control and operation of such systems are made.

15 GEOTHERMAL ENERGY↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Model Assumptions and Data Characteristics: Impacts on Domain Adaptation in Building Segmentation

Studies on domain adaptation (DA) for remote sensing (RS) imagery analysis lack consistency in selection and description of evaluation scenarios. Without properly characterizing datasets, model assumptions, and evaluation scenarios, it is difficult to objectively compare DA methods and reach conclusions about their suitability across different applications. With this motivation, this work seeks to empirically assess to which extent the interaction between data characteristics and model assumptions influences the effectiveness of DA methods. Using the widely explored task of building footprint segmentation as a case study, we perform a large-scale study across over 200 DA scenarios that include variations across view angles, areas observed, and sensors used for data acquisition. Rather than adopting different model architectures or optimization criteria, we contrast the performances of two DA methods based on adversarial learning that differ only in their assumptions about source and target domains. Informed by metadata and data characteristics unveiled using traditional computer vision (CV) techniques as well as pretrained deep models, we provide a detailed meta-analysis of experiments highlighting the importance of accurately considering data assumptions for DA in RS segmentation tasks. As demonstrated by a “cherry-picking” exercise, different claims regarding which model is best could be made by selecting different subsets of evaluation scenarios. While well-calibrated assumptions can be beneficial, mismatching assumptions can lead to negative biases in DA applications. Furthermore, this study intends to motivate the community toward more consistent evaluation protocols while providing recommendations and insights toward creating novel benchmark datasets, documenting data characteristics, application-specific knowledge, and model assumptions.

42 ENGINEERING↗

Using the BEopt Automated Residential Simulation Test Suite to Enable Comparative Analysis Between Energy Simulation Engines: Preprint

Verification and validation are crucial software quality control procedures when developing and implementing models. This is particularly important as a variety of stakeholders rely on accurate predictions from building simulation programs. This study uses the BEopt Automated Residential Simulation Test Suite (BARTS) to facilitate comparison of two energy simulation engines across various building components and includes models that isolate the impacts of specific building components on annual energy consumption. As a case study, BARTS has been used to identify important discrepancies between the engines for several components of the building models; these discrepancies are caused by differences in the models used by the engines or coding errors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An agent-based stochastic Occupancy Simulator

Occupancy has significant impacts on building performance. However, in current building performance simulation programs, occupancy inputs are static and lack diversity, contributing to discrepancies between the simulated and actual building performance. This work presents an Occupancy Simulator that simulates the stochastic behavior of occupant presence and movement in buildings, capturing the spatial and temporal occupancy diversity. Each occupant and each space in the building are explicitly simulated as an agent with their profiles of stochastic behaviors. The occupancy behaviors are represented with three types of models: (1) the status transition events (e.g., first arrival in office) simulated with probability distribution model, (2) the random moving events (e.g., from one office to another) simulated with a homogeneous Markov chain model, and (3) the meeting events simulated with a new stochastic model. A hierarchical data model was developed for the Occupancy Simulator, which reduces the amount of data input by using the concepts of occupant types and space types. Finally, a case study of a small office building is presented to demonstrate the use of the Simulator to generate detailed annual sub-hourly occupant schedules for individual spaces and the whole building. The Simulator is a web application freely available to the public and capable of performing a detailed stochastic simulation of occupant presence and movement in buildings. Future work includes enhancements in the meeting event model, consideration of personal absent days, verification and validation of the simulated occupancy results, and expansion for use with residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗