MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-H-207B-00: MRgRT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

High-energy proton imaging for biomedical applications

The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. As a result, tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lithography with MeV Energy Ions for Biomedical Applications: Accelerator Considerations

MeV ion beam lithographies are very powerful techniques for 3D direct writing in positive or negative photoresist materials. Nanometer-scale rough structures, or clear areas with straight vertical sidewalls as thin as a few 10's of nm in a resist of a few nm to 100 {mu}m thickness can be made. These capabilities are particularly useful for lithography in cellular- and sub-cellular level biomedical research and technology applications. It can be used for tailor making special structures such as optical waveguides, biosensors, DNA sorters, spotting plates, systems for DNA, protein and cell separation, special cell-growth substrates and microfluidic lab-on-a-chip devices. Furthermore MeV ion beam lithography can be used for rapid prototyping, and also making master stamps and moulds for mass production by hot embossing and nanoimprint lithography. The accelerator requirements for three different high energy ion beam lithography techniques are overviewed. We consider the special requirements placed on the accelerator and how this is achieved for a commercial proton beam writing tool.

43 PARTICLE ACCELERATORS↗

A solvent replenishment solution for managing evaporation of biochemical reactions in air-matrix digital microfluidics devices

Digital microfluidics (DMF) is a powerful technique for sample preparation and analysis for a broad range of biological and chemical applications. In many cases, it is desirable to carry out DMF on an open surface, such that the matrix surrounding the droplets is ambient air. However, the utility of the air-matrix DMF format has been severely limited by problems with droplet evaporation, especially when the droplet-based biochemical reactions require high temperatures for long periods of time. We present a simple solution for managing evaporation in air-matrix DMF: just-in-time replenishment of the reaction volume using droplets of solvent. We demonstrate that this solution enables DMF-mediated execution of several different biochemical reactions (RNA fragmentation, first-strand cDNA synthesis, and PCR) over a range of temperatures (4–95 °C) and incubation times (up to 1 h or more) without use of oil, humidifying chambers, or off-chip heating modules. Reaction volumes and temperatures were maintained roughly constant over the course of each experiment, such that the reaction kinetics and products generated by the air-matrix DMF device were comparable to those of conventional benchscale reactions. As a result, this simple yet effective solution for evaporation management is an important advance in developing air-matrix DMF for a wide variety of new, high-impact applications, particularly in the biomedical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanomechanics of hard films on compliant substrates.

Development of flexible thin film systems for biomedical, homeland security and environmental sensing applications has increased dramatically in recent years [1,2,3,4]. These systems typically combine traditional semiconductor technology with new flexible substrates, allowing for both the high electron mobility of semiconductors and the flexibility of polymers. The devices have the ability to be easily integrated into components and show promise for advanced design concepts, ranging from innovative microelectronics to MEMS and NEMS devices. These devices often contain layers of thin polymer, ceramic and metallic films where differing properties can lead to large residual stresses [5]. As long as the films remain substrate-bonded, they may deform far beyond their freestanding counterpart. Once debonded, substrate constraint disappears leading to film failure where compressive stresses can lead to wrinkling, delamination, and buckling [6,7,8] while tensile stresses can lead to film fracture and decohesion [9,10,11]. In all cases, performance depends on film adhesion. Experimentally it is difficult to measure adhesion. It is often studied using tape [12], pull off [13,14,15], and peel tests [16,17]. More recent techniques for measuring adhesion include scratch testing [18,19,20,21], four point bending [22,23,24], indentation [25,26,27], spontaneous blisters [28,29] and stressed overlayers [7,26,30,31,32,33]. Nevertheless, sample design and test techniques must be tailored for each system. There is a large body of elastic thin film fracture and elastic contact mechanics solutions for elastic films on rigid substrates in the published literature [5,7,34,35,36]. More recent work has extended these solutions to films on compliant substrates and show that increasing compliance markedly changes fracture energies compared with rigid elastic solution results [37,38]. However, the introduction of inelastic substrate response significantly complicates the problem [10,39,40]. As a result, our understanding of the critical relationship between adhesion, properties, and fracture for hard films on compliant substrates is limited. To address this issue, we integrated nanomechanical testing and mechanics-based modeling in a program to define the critical relationship between deformation and fracture of nanoscale films on compliant substrates. The approach involved designing model film systems and employing nano-scale experimental characterization techniques to isolate effects of compliance, viscoelasticity, and plasticity on deformation and fracture of thin hard films on substrates that spanned more than two orders of compliance magnitude exhibit different interface structures, have different adhesion strengths, and function differently under stress. The results of this work are described in six chapters. Chapter 1 provides the motivation for this work. Chapter 2 presents experimental results covering film system design, sample preparation, indentation response, and fracture including discussion on the effects of substrate compliance on fracture energies and buckle formation from existing models. Chapter 3 describes the use of analytical and finite element simulations to define the role of substrate compliance and film geometry on the indentation response of thin hard films on compliant substrates. Chapter 4 describes the development and application of cohesive zone model based finite element simulations to determine how substrate compliance affects debond growth. Chapter 5 describes the use of molecular dynamics simulations to define the effects of substrate compliance on interfacial fracture of thin hard tungsten films on silicon substrates. Chapter 6 describes the Workshops sponsored through this program to advance understanding of material and system behavior.

36 MATERIALS SCIENCE↗

WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-02: MR-Driven RT Planning

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-03: MRI Guidance in the Radiation Therapy Clinic: Site-Specific Discussions

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-04: Strategies for Adaptive RT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

Evaluation of the Accuracy of Astroskin as a Behavioral Health Self-Monitoring System for Spaceflight

In space, there is a need to monitor astronauts' vital signs and assess their readiness to perform specific tasks during a mission. Currently, NASA does not have the capability to noninvasively monitor crew for extended periods of time. The Canadian Space Agency is working with the Psychophysiology Lab at NASA ARC to determine if the Astroskin could be used as a solution to this problem. Astroskin, a commercially available garment with built-in biosensors, can be comfortably worn under clothing or a spacesuit and relay information to the crewman's own mobile device. Data can also be sent wirelessly to the on-board Exploration Medical System. To determine if Astroskin meets requirements for health monitoring, it must first be validated in spaceflight analog environments. In the current study Astroskin data will be compared to traditional biomedical instrument measures of electrocardiography (ECG), respiration rate, and systolic blood pressure. The data will be recorded during Autogenic Feedback Training Exercise (AFTE), which is a type of physiological self-regulation training designed for astronauts. The data will also be recorded during simulations of the Orion spacecraft re-entry. The results to date suggest that Astroskin is a suitable ambulatory monitoring system that allows astronauts to self-diagnose and self-regulate adverse autonomic nervous system responses to sustained exposure to microgravity of spaceflight.

biomedical↗

Integrated Multiscale Modeling of Molecular Computing Devices

Nanoscience has been one of the major research focuses of the U.S. and much of the world for the past decade, in part because of its promise to revolutionize many fields, including materials, medicine, and electronics. At the heart of this promise is the fact that nanostructured materials can behave radically differently than their macroscopic counterparts (e.g., bulk gold is such an inert metal that it has found applications in such diverse fields as jewelry, biomedical implants and dentistry, whereas gold nanoparticles are highly reactive and are thus useful as nanocatalysts) and have properties that are tunable due to a strong dependence on the size and surface area of the nanostructure. Thus, nanoscience offers a remarkable opportunity to develop new functional systems built around nanostructured materials with unusual and tunable properties and functionality. The transition from nanoscience to nanotechnology becomes possible when nanostructured systems can be made reproducibly by processes that can be implemented on a large scale. The microelectronics industry is one example of an industry that has evolved into the realm of nanotechnology, since the exponential reduction in feature size in computer chips has resulted in feature sizes now under 50nm (45nm in production, 32nm demonstrated; feature size has been going down by a factor of approximately 1/{radical}2 every 18 months as chip density has doubled every 18 months according to Moore's law). Silicon-based microelectronics relies on etching features into a single-crystal silicon substrate by photolithography. As the feature size of silicon-based microelectronics continues to decrease, the continuation of Moore's law to below 20nm feature sizes is being questioned, due to limitations in both the physics of the transistors (leading to unacceptable power dissipation) and doubts about the scalability of top-down photolithography-based manufacturing to such small sizes. There is no doubt that photolithography will some day reach a miniaturization limit, forcing designers of Si-based electronics to pursue increased performance by other means. Any other alternative approach would have the unenviable task of matching the ability of Si technology to pack more than a billion interconnected and addressable devices on a chip the size of a thumbnail. Nevertheless, the prospects of developing alternative approaches to fabricate electronic devices have spurred an ever-increasing pace of fundamental research. One of the promising possibilities is molecular electronics (ME), self-assembled molecular-based electronic systems composed of single-molecule devices in ultra dense, ultra fast molecular-sized components. This project focused on developing accurate, reliable theoretical modeling capabilities for describing molecular electronics devices. The participants in the project are given in Table 1. The primary outcomes of this fundamental computational science grant are publications in the open scientific literature. As listed below, 62 papers have been published from this project. In addition, the research has also been the subject of more than 100 invited talks at conferences, including several plenary or keynote lectures. Many of the goals of the original proposal were completed. Specifically, the multi-disciplinary group developed a unique set of capabilities and tools for investigating electron transport in fabricated and self-assembled nanostructures at multiple length and time scales.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

SU-F-T-515: Increased Skin Dose in Supine Craniospinal Irradiation Due to Carbon Fiber Couch and Vacuum Bag Immobilization Device

Purpose: To measure the surface dose for supine craniospinal irradiation employing posterior beams, treating through an imaging couch and BlueBag immobilization device. Methods: The percentage depth dose (PDD) in the buildup region of a clinical 6 MV photon beam was measured using an Advanced Markus parallel plate ionization chamber in a solid water phantom. The PDD from a 10×10 cm{sup 2} anterior beam was measured at 100 cm SSD, simulating a traditional prone craniospinal technique. The measurements were compared to commissioning and treatment planning system data. The PDD was also measured in a posterior setup with the phantom surface laying directly on the Brainlab carbon fiber imaging couch, with the phantom surface 100 cm from the source, simulating a supine craniospinal setup. The posterior measurements were repeated with a BlueBag vacuum immobilization device between the couch and phantom, with thicknesses of 1.7 cm and 5 cm. The PDD from a 10×10 cm{sup 2} field and a typical 6×30 cm{sup 2} craniospinal field were also compared. The PDDs were normalized at 5 cm to reflect typical craniospinal prescription dose normalization. Results: The measured PDD curve from the anterior setup agreed well with commissioning and treatment planning data, with surface doses of 19.9%, 28.8% and 27.7%, respectively. The surface doses of the 10×10 cm{sup 2} and 6×30 cm{sup 2} fields delivered through the imaging couch were both 122.4%. The supine setup yielded surface doses of 122.4%, 121.6%, and 119.6% for the couch only, 1.7 cm bag, and 5 cm bag setups, respectively. Conclusion: Delivering craniospinal irradiation through a carbon fiber couch removes the majority of skin sparing. The addition of a vacuum bag immobilization device restores some skin sparing, but the magnitude of this effect is negligible.

60 APPLIED LIFE SCIENCES↗

Imaging Beyond What Man Can See

Three lightweight, portable hyperspectral sensor systems have been built that capture energy from 200 to 1700 nanometers (ultravio1et to shortwave infrared). The sensors incorporate a line scanning technique that requires no relative movement between the target and the sensor. This unique capability, combined with portability, opens up new uses of hyperspectral imaging for laboratory and field environments. Each system has a GUI-based software package that allows the user to communicate with the imaging device for setting spatial resolution, spectral bands and other parameters. NASA's Space Partnership Development has sponsored these innovative developments and their application to human problems on Earth and in space. Hyperspectral datasets have been captured and analyzed in numerous areas including precision agriculture, food safety, biomedical imaging, and forensics. Discussion on research results will include realtime detection of food contaminants, molds and toxin research on corn, identifying counterfeit documents, non-invasive wound monitoring and aircraft applications. Future research will include development of a thermal infrared hyperspectral sensor that will support natural resource applications on Earth and thermal analyses during long duration space flight. This paper incorporates a variety of disciplines and imaging technologies that have been linked together to allow the expansion of remote sensing across both traditional and non-traditional boundaries.

May, George↗

SU-F-T-505: A Novel Approach for Sparing Critical Organs at Risk for Cancer Patients Undergoing Radiation Oncology Treatments

Purpose: A major goal of an effective radiation treatment plan is to deliver the maximum dose to the tumor while minimizing radiation exposure to the surrounding normal structures. For example, due to the radiation exposure to neighboring critical structures during prostate cancer treatment, a significant increase in cancer risk was observed for the bladder (77%) and the rectum (105%) over the following decade. Consequently, an effective treatment plan necessitates limiting the exposure to such organs which can best be achieved by physically displacing the organ at-risk. The goal of this study is to present a prototype for an organ re-positioner device designed and fabricated to physically move the rectum away from the path of radiation beam during external beam and brachytherapy treatments. This device affords patient comfort and provides a fully controlled motion to safely relocate the rectum during treatment. Methods: The NiTi shape memory alloy was designed and optimized for manufacturing a rectal re-positioner device through cooling and heating the core alloy for its shaping. This has been achieved through a prototyped custom designed electronic circuit in order to induce the reversible austenitic transformation and was tested rigorously to ensure the integrity of the actuated motion in displacement of the target anatomy. Results: The desirable NiTi shape-setting was configured for easy insertion and based on anatomical constraint. When the final prototype was evaluated, accuracy and precision of the maximum displacement and temperature changes revealed that the device could safely be used within the target anatomy. Conclusion: The organ re-positioner device is a promising tool that can be implemented in clinical setting. It provides a controlled and safe displacement of the delicate organ(s) at risk. The location of the organ being treated could also be identified using conventional onboard imaging devices or MV imaging available on-board most modern clinical accelerators.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗