Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ballooning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Measurement of 0.511-MeV gamma rays with a balloon-borne Ge/Li/ spectrometer

A collimated high-resolution gamma ray spectrometer was flown on a balloon over Palestine, Texas, on June 10, 1974, to obtain measurements of the terrestrial and extraterrestrial 0.511-MeV gamma rays. The spectrometer consists of four 40-cu-cm Ge(Li) crystals operating in the energy range 0.06-10 MeV; this cluster of detectors is surrounded by a CsI(Na) anticoincidence shield. This system is used primarily to allow measurements of the two escape peaks associated with high-energy gamma ray lines. It also allows a measurement of the background component of the 0.511-MeV flux produced by beta(+) decays in materials inside the CsI(Na) shield. It is shown that the measurements of the atmospheric fluxes are consistent with earlier results after allowance is made for an additional component of the background due to beta(+) decays produced by neutron- and proton-initiated interactions with materials in and near the detector. Results of the extraterrestrial flux require an extensive detailed analysis of the time-varying background because of activation buildup and balloon spatial drifts.

Ling, J. C.↗

A Multi-Band Far-Infrared Survey with a Balloon-Borne Telescope

Nine additional radiation sources, above a 3-sigma confidence level of 1300 Jy, were identified at 100 microns by far infrared photometry of the galactic plane using a 0.4 meter aperture, liquid helium cooled, multichannel far infrared balloon-borne telescope. The instrument is described, including its electronics, pointing and suspension systems, and ground support equipment. Testing procedures and flight staging are discussed along with the reduction and analysis of the data acquired. The history of infrared astronomy is reviewed. General infrared techniques and the concerns of balloon astronomers are explored.

Jacobson, M. R.↗

Medium energy gamma ray astronomy with transpacific balloon flights

Transpacific balloon flights with the University of California, Riverside (UCR) double scatter telescope are discussed. With flight durations from 5 days up to perhaps 15 days the long observation times necessary for medium energy (1-30 MeV) gamma ray astronomy can be obtained. These flights would be made under the auspices of the Joint U.S.-Japan Balloon Flight Program at NASA. It is proposed that flights can provide at least 30 hours of observation time per flight for many discrete source candidates and 120 hours for detecting low intensity cosmic gamma ray bursts.

Zych, A. D.↗

A 102 cm balloon-borne telescope for far-infrared astronomical observations

In early 1971, a program was initiated to develop a balloon-borne 102-cm telescope, capable of carrying out far-infrared observations of astronomical interest above the earth's atmosphere in the wavelength range from 40 to 250 micrometers. Since 1972 the telescope has been flown and successfully recovered a total of sixteen times. Ten of the flights have produced high quality astronomical data, resulting in more than 80 hours of photometric and spectroscopic observations of numerous objects, such as H II regions, dark clouds, molecular clouds, X-ray sources, galaxies, the galactic center, planets, the Moon, and an asteroid. Attention is given to the telescope optics, the gondola, altitude control, the auxiliary attitude control system, the determination of telescope pointing position, telemetry, power requirements, the flight record, and the four instruments which are available for use on the balloon-borne telescope.

Fazio, G. G.↗

A unified thermal and vertical trajectory model for the prediction of high altitude balloon performance

A computer model for the prediction of the trajectory and thermal behavior of zero-pressure high altitude balloon was developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data from several flights and newly discovered features are discussed.

Carlson, L. A.↗

A new thermal and trajectory model for high altitude balloons

A new computer model for the prediction of the trajectory and thermal behavior of high altitude balloons has been developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data and newly discovered features are discussed.

Carlson, L. A.↗

Balloon-borne scanning spectrometer system for atmospheric extinction studies in the 350-1100 nm spectral region

A scanning spectrometer system which is capable of being flown in high-altitude balloon studies of the earth's atmosphere is presented. The instrument is small, has a large operative wavelength range of 350-1100 nm, high data density, and real-time data telemetry to ground. A computer software package is used to provide a real-time monitor of balloon gondola and instrument performance, with the software reliability enhanced by proof of correctness techniques and exhibiting the high degree of reliability necessary for the monitoring system.

Thompson, D. A.↗

Penetration of solar irradiance in the Schumann-Runge bands of O2 - A comparison of balloon-borne measurements and calculations

Measurements of the attenuated solar irradiance made from the STRATCOM VIII balloon are compared with calculated values of the solar irradiance reaching the 40 km level for a solar zenith angle of 66.18 deg. The ability of theory to match intensity maxima which correspond to the cross section minima between the bands is investigated. The comparisons show that model results are too small by a factor of 1.8 between 199 and 22 nm, which is attributed to a systematic calibration offset between the balloon data and the irradiances of Bruckner et al. (1976). A large disagreement between the observed and calculated intensities at peaks H and I results from an error in the cross sections used in current aeronomic work.

Frederick, J. E.↗

Simulator spectral characterization using balloon calibrated solar cells with narrow band pass filters

The development and implementation of an instrument for spectral measurement of solar simulators for testing solar cell characteristics is reported. The device was constructed for detecting changes in solar simulator behavior and for comparing simulator spectral irradiance to solar AM0 output. It consists of a standard solar cell equipped with a band pass filter narrow enough so that, when flown on a balloon to sufficient altitude along with sufficient numbers of cells, each equipped with filters of different bandpass ratings, the entire spectral response of the standard cell can be determined. Measured short circuit currents from the balloon flights thus produce cell devices which, when exposed to solar simulator light, have a current which does or does not respond as observed under actual AM0 conditions. Improvements of the filtered cells in terms of finer bandpass filter tuning and measurement of temperature coefficients are indicated.

Goodelle, G. S.↗

A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

Paciesas, W. S.↗

Balloon-borne pressure sensor performance evaluation utilizing tracking radars

The pressure sensors on balloon-borne sondes relate the sonde measurements to height above the Earth's surface through the hypsometric equation. It is crucial that sondes used to explore the vertical structure of the atmosphere do not contribute significant height errors to their measurements of atmospheric constituent concentrations and properties. A series of radiosonde flights was conducted. In most cases, each flight consisted of two sondes attached to a single balloon and each flight was tracked by a highly accurate C-band radar. For the first 19 radiosonde flights, the standard aneroid cell baroswitch assembly used was the pressure sensor. The last 26 radiosondes were equipped with a premium grade aneroid cell baroswitch assembly sensor and with a hypsometer. It is shown that both aneroid cell baroswitch sensors become increasingly inaccurate with altitude. The hypsometer radar differences are not strongly dependent upon altitude and it is found that the standard deviation of the differences at 35 km is 0.179 km.

Norcross, G. A.↗

Use of a Fourier transform spectrometer on a balloon-borne telescope and at the multiple mirror telescope (MMT)

The design and use of an infrared Fourier transform spectrometer which has been used for observations of laboratory, stratospheric, and astronomical spectra are described. The spectrometer has a spectral resolution of 0.032/cm and has operated in the mid-infrared (12 to 13 microns) as well as the far-infrared (40 to 140 microns), using both bolometer and photoconductor cryogenic detectors. The spectrometer is optically sized to accept an f/9 beam from the multi-mirror telescope (MMT). The optical and electronic design are discussed, including remote operation of the spectrometer on a balloon-borne 102-cm telescope. The performance of the laser-controlled, screw-driven moving cat's-eye mirror is discussed. Segments of typical far-infrared balloon flight spectra, lab spectra, and mid-infrared MMT spectra are presented. Data reduction, interferogram processing, artifact removal, wavelength calibration, and intensity calibration methods are discussed. Future use of the spectrometer is outlined.

Traub, W. A.↗

Low-frequency (f less than about 1 Hz) stratospheric electrical noise measured by balloon-borne sensors

Low-frequency (f less than about 1 Hz) stratospheric electrical noise is occasionally observed by balloon-borne sensors. The phenomenon occurs 1-3 percent of the time, with maximum incidence during the morning hours. It appears to be related to fluctuations of the electrical conductivity of the medium around the balloons, produced by air turbulence due to the wind shear and/or gravity waves.

Iversen, I. B.↗

Balloon film strain measurement

A discussion is presented of the results of a flight test program in which scientific research balloon material strain was measured in order to determine stress levels. Attention is given to material strain characteristics during the inflation, launch, ascent, and flight of a natural shape, zero-pressure scientific balloon. Measurements were conducted with a simple thin film strain transducer. Thermal, meridional and circumferential strain history data for the test flight are given.

Rand, J. L.↗

Electrodynamics of the stratosphere using 5000 cu m superpressure balloons

The Electrodynamics of the Middle Atmosphere research project encompasses the design of a microprocessor-controlled payload and the launch of up to eight small superpressure balloons in the 1982-1984 period. The primary payload instrument will measure the vector electric field from dc to 10 kHz, and the payloads will include instruments measuring local ionization, electrical conductivity, magnetic field, and temperature and pressure fluctuations. In addition, optical lightning will be recorded. The simultaneous measurement of these stratospheric parameters by several balloons, for periods extending over several solar rotations, will allow the study of electrical coupling between atmosphere and magnetosphere, of global current systems, and of global response to solar flares and magnetospheric storms.

Holzworth, R. H.↗

A mercuric detector system for X-ray astronomy. 2. Results from flight tests of a balloon borne instrument

To establish the expected sensitivity of a new hard X-ray telescope design, an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate (Bi4Ge3O12) scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, Texas. The second flight of this instrument established a differential background counting rate of 4.2 O.7 x 10-5 counts/sec cm keV over the energy range of 40 to 80 keV. This measurement was within 50% of the predicted value. The measured rate is approx 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range. The prediction was based on a Monte Carlo simulation of the detector assembly in the radiation environment at float altitude.

Vallerga, J.↗

A balloon-borne high-resolution spectrometer for observations of gamma-ray emission from solar flares

The design, development, and balloon-flight verification of a payload for observations of gamma-ray emission from solar flares are reported. The payload incorporates a high-purity germanium semiconductor detector, standard NIM and CAMAC electronics modules, a thermally stabilized pressure housing, and regulated battery power supplies. The flight system is supported on the ground with interactive data-handling equipment comprised of similar electronics hardware. The modularity and flexibility of the payload, together with the resolution and stability obtained throughout a 30-hour flight, make it readily adaptable for high-sensitivity, long-duration balloon fight applications.

Crannell, C. J.↗

Balloon materials degradation (S1006)

The objective of this experiment is to assess the effects of long-term exposure of candidate balloon films, tapes, and lines to the hostile environment above the Earth's atmosphere. Degradation of mechanical and radiometric properties will be observed by a series of tests on exposed materials. The experiment is passive and will test candidate balloon films, tapes, and lines. The experiment will occupy one-third of a 3-in.-deep peripheral tray. Two additional identical sets of material will be prepared. The first set will be tested immediately and the second will be held in a controlled environment until the recovery of the samples placed on orbit. Tests will then be performed on this second set to determine any effects of aging. The specimens that are recovered from the Long Duration Exposure Facility will also be tested and the effects of long-duration exposure noted. In addition to these specimens, another set of specimens will be exposed at an accelerated exposure facility and the results will be compared with those of specimens exposed in situ.

Allen, D. H.↗