Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “automatic calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Construction and performance characteristics of a prototype NBS/GPS receiver

The construction and performance characteristics of a low-cost, high-accuracy GPS C/A receiver are reviewed. The receiver takes advantage of a simultaneous common view of the same satellites, which could allow time transfer with accuracies on the order of 10 ns or less for baselines as large as 3000 km. Frequency can be measured to better than one part in 10 to the 14th. The software and the receiver are configured to be fully automatic with a Z80A microprocessor setting the amplitude for the lock loops of the receiver and setting the synthesizer with corrects for Doppler shift. The microprocessor can calibrate a 0.1 ns built-in time interval counter.

Davis, D. D.↗

NASA Tech Briefs, December 2006

Topic include: Inferring Gear Damage from Oil-Debris and Vibration Data; Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs; User Interactive Software for Analysis of Human Physiological Data; Representation of Serendipitous Scientific Data; Automatic Locking of Laser Frequency to an Absorption Peak; Self-Passivating Lithium/Solid Electrolyte/Iodine Cells; Four-Quadrant Analog Multipliers Using G4-FETs; Noise Source for Calibrating a Microwave Polarimeter; Hybrid Deployable Foam Antennas and Reflectors; Coating MCPs with AlN and GaN; Domed, 40-cm-Diameter Ion Optics for an Ion Thruster; Gesture-Controlled Interfaces for Self-Service Machines; Dynamically Alterable Arrays of Polymorphic Data Types; Identifying Trends in Deep Space Network Monitor Data; Predicting Lifetime of a Thermomechanically Loaded Component; Partial Automation of Requirements Tracing; Automated Synthesis of Architecture of Avionic Systems; SSRL Emergency Response Shore Tool; Wholly Aromatic Ether-Imides as n-Type Semiconductors; Carbon-Nanotube-Carpet Heat-Transfer Pads; Pulse-Flow Microencapsulation System; Automated Low-Gravitation Facility Would Make Optical Fibers; Alignment Cube with One Diffractive Face; Graphite Composite Booms with Integral Hinges; Tool for Sampling Permafrost on a Remote Planet; and Special Semaphore Scheme for UHF Spacecraft Communications.

Source record↗

SU-E-T-641: Proton Range Measurements Using a Geometrically Calibrated Liquid Scintillator Detector

Purpose: The purpose of this work is to develop a geometric calibration method to accurately calculate physical distances within a liquid scintillator detector and to assess the accuracy, consistency, and robustness of proton beam range measurements when using a liquid scintillator detector system with the proposed geometric calibration process. Methods: We developed a geometric calibration procedure to accurately convert pixel locations in the camera frame into physical locations in the scintillator frame. To ensure accuracy, the geometric calibration was performed before each experiment. The liquid scintillator was irradiated with spot scanning proton beams of 94 energies in two deliveries. A CCD camera was used to capture the two-dimensional scintillation light profile of each of the proton energies. An algorithm was developed to automatically calculate the proton range from the acquired images. The measured range was compared to the nominal range to assess the accuracy of the detector. To evaluate the robustness of the detector between each setup, the experiments were repeated on three different days. To evaluate the consistency of the measurements between deliveries, three sets of measurements were acquired for each experiment. Results: Using this geometric calibration procedure, the proton beam ranges measured using the liquid scintillator system were all within 0.3mm of the nominal range. The average difference between the measured and nominal ranges was −0.20mm. The delivery-to-delivery standard deviation of the proton range measurement was 0.04mm, and the setup-to-setup standard deviation of the measurement was 0.10mm. Conclusion: The liquid scintillator system can measure the range of all 94 beams in just two deliveries. With the proposed geometric calibration, it can measure proton range with sub-millimeter accuracy, and the measurements were shown to be consistent between deliveries and setups. Therefore, we conclude that the liquid scintillator system provides a reliable and convenient tool for proton range measurement. This project was supported in part by award number CA182450 from the National Cancer Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-D-9A-06: Open Source Monitor Calibration and Quality Control Software for Enterprise Display Management

Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary and secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.

60 APPLIED LIFE SCIENCES↗

Characterization of the Exradin W1 scintillator for use in radiotherapy

Purpose: To evaluate the main characteristics of the Exradin W1 scintillator as a dosimeter and to estimate measurement uncertainties when used in radiotherapy. Methods: We studied the calibration procedure, energy and modality dependence, short-term repeatability, dose-response linearity, angular dependence, temperature dependence, time to reach thermal equilibrium, dose-rate dependence, water-equivalent depth of the effective measurement point, and long-term stability. An uncertainty budget was derived for relative and absolute dose measurements in photon and electron beams. Results: Exradin W1 showed a temperature dependence of −0.225% °C{sup −1}. The loss of sensitivity with accumulated dose decreased with use. The sensitivity of Exradin W1 was energy independent for high-energy photon and electron beams. All remaining dependencies of Exradin W1 were around or below 0.5%, leading to an uncertainty budget of about 1%. When a dual channel electrometer with automatic trigger was not used, timing effects became significant, increasing uncertainties by one order of magnitude. Conclusions: The Exradin W1 response is energy independent for high energy x-rays and electron beams, and only one calibration coefficient is needed. A temperature correction factor should be applied to keep uncertainties around 2% for absolute dose measurements and around 1% for relative measurements in high-energy photon and electron beams. The Exradin W1 scintillator is an excellent alternative to detectors such as diodes for relative dose measurements.

60 APPLIED LIFE SCIENCES↗

Design considerations for a Digital Twin built to improve nitrification performance at a water resource recovery facility

A Digital Twin built around Activated Sludge Model No. 1 was deployed at a full-scale water resource recovery facility. Its design included a waste rate recommender system based on automatic scenario analyses, where influent loads and waste rates are varied to determine their impact on nitrification. At the same frequency as these scenario analyses, scheduled auto-calibrations allow for nitrifier maximum specific growth rate (μmax-NITO) soft sensing, the only kinetic parameter shown to require adjustment if the objective is aeration tank effluent ammonia forecasting accuracy. By integrating temperature forecasting over the next three sludge ages, this Digital Twin approach creates opportunities for advancing waste rate decisions in anticipation of seasonal temperature changes, optimizing ammonia control authority under varying influent loads, and furnishing valuable insights for future capital projects requiring nitrifier kinetic understanding and modelling.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a low-cost and accurate ocean temperature logger on subsurface mooring systems

Monitoring seawater temperature is important to understanding evolving ocean processes. To monitor internal waves or ocean mixing, a large number of temperature loggers are typically mounted on subsurface mooring systems to obtain high-resolution temperature data at different water depths. In this study, we redesigned and evaluated a compact, low-cost, self-contained, high-resolution and high-accuracy ocean temperature logger, TC-1121. The newly designed TC-1121 loggers are smaller, more robust, and their sampling intervals can be automatically changed by indicated events. They have been widely used in many mooring systems to study internal wave and ocean mixing. The logger’s fundamental design, noise analysis, calibration, drift test, and a long-term sea trial are discussed in this paper.

Internal waves, Ocean mixing, Temperature loggers,↗

Nondestructive Test Probe

Under the Aircraft Structural Integrity program, Langley Research Center invented a device to detect fatigue cracks in aluminum alloy plates. Krautkramer Branson obtained an exclusive license and commercialized a hand-held device, the "CrackFinder," an electromagnetic probe for nondestructive evaluation, used to scan aircraft skins for surface breaks. The technology involves an eddy current, which is an electrical current induced by an alternating magnetic field. The CrackFinder also employs an innovative self-nulling feature, where the device automatically recalibrates to zero so that each flaw detected produces a reading. Compared to conventional testing systems, the CrackFinder is affordable, small, simple to use, and needs no calibration.

Source record↗

Flight Characteristics of a 1/4-Scale Model of the XFV-1 Airplane (TED No. NACA DE-378)

A l/4-scale dynamically similar model of the XFV-1 airplane has been flown in the Ames 40- by 80-foot wind tunnel, using the trailing flight-cable technique. This investigation was devoted to establishing the flight characteristics of the model in forward flight from hovering to wing stall, and in yawed flight (wing span alined with the relative wind) from hovering to the maximum speed at which controlled flight could be maintained. Landings, take-offs, and hovering characteristics in flights close to the ground were also investigated.. Since the remote control system for the model was rather complicated and provided artificial damping about the pitch, roll, and yaw axes, sufficient data from the control-system calibration tests are included in this report to specify the performance of the control system in relation to both the model flight tests and the design of an automatic control system for the full-scale airplane. The model in hovering flight appeared to be neutrally stable. The response of the model to the controls was very rapid, and it was always necessary to provide some amount of artificial damping to maintain control. The model could be landed with little difficulty by hovering approximately a foot above the floor and then cutting the power. Take-offs were more difficult to perform, primarily because the rate of change in power to the model motors was limited by the characteristics of the available power source. The model was,capable of controlled yawed flight at translational velocities up to and including 20 feet per second. The effectiveness of the controls decreased with increasing speed, however, and at 25 fps control in pitch, and probably roll, was lost completely. The model was flown in controlled forward flight from hovering up to 70 fps. During these flights the model appeared to be more difficult to control in yaw than it was in pitch or roll. The flights of the model were recorded by motion picture cameras. These motion pictures are available on loan from NACA Headquarters as a film supplement to this report.

Kelly, Mark W.↗

Automated model generation and parameter estimation of building energy models using an ontology-based framework

This study presents a methodology for automated model generation and parameter estimation of building energy models using semantic modeling and Bayesian estimation. Semantic modeling techniques are used to represent the system components and their interactions, facilitating the automatic generation of a simulation model from dynamic component models. The proposed approach is applied to a case study of a ventilation system where a simulation model is generated, calibrated, and assessed through different performance metrics. These metrics demonstrate the accuracy and reliability of both model point estimates and probabilistic prediction intervals across all model outputs. Overall, the proposed methodology offers a systematic and automated approach to model development and calibration in building energy systems, with potential applications in building performance analysis, monitoring, and optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ionospheric corrections to precise time transfer using GPS

The free electrons in the earth's ionosphere can retard the time of reception of GPS signals received at a ground station, compared to their time in free space, by many tens of nanoseconds, thus limiting the accuracy of time transfer by GPS. The amount of the ionospheric time delay is proportional to the total number of electrons encountered by the wave on its path from each GPS satellite to a receiver. This integrated number of electrons is called Total Electron Content, or TEC. Dual frequency GPS receivers designed by Allen Osborne Associates, Inc. (AOA) directly measure both the ionospheric differential group delay and the differential carrier phase advance for the two GPS frequencies and derive from this the TEC between the receiver and each GPS satellite in track. The group delay information is mainly used to provide an absolute calibration to the relative differential carrier phase, which is an extremely precise measure of relative TEC. The AOA Mini-Rogue ICS-4Z and the AOA TurboRogue ICS-4000Z receivers normally operate using the GPS P code, when available, and switch to cross-correlation signal processing when the GPS satellites are in the Anti-Spoofing (A-S) mode and the P code is encrypted. An AOA ICS-Z receiver has been operated continuously for over a year at Hanscom AFB, MA to determine the statistics of the variability of the TEC parameter using signals from up to four different directions simultaneously. The 4-channel ICS-4Z and the 8-channel ICS-4000Z, have proven capabilities to make precise, well calibrated, measurements of the ionosphere in several directions simultaneously. In addition to providing ionospheric corrections for precise time transfer via satellite, this dual frequency design allows full code and automatic codeless operation of both the differential group delay and differential carrier phase for numerous ionospheric experiments being conducted. Statistical results of the data collected from the ICS-4Z during the initial year of ionospheric time delay in the northeastern U.S., and initial results with the ICS-4000Z, will be presented.

Snow, Robert W.↗

Calibration of linear contact stiffnesses in discrete element models using a hybrid analytical-computational framework

Efficient selections of particle-scale contact parameters in discrete element modelling remain an open question. The purpose of this study is to provide a hybrid calibration framework to estimate linear contact stiffnesses (normal and tangential) for both two-dimensional and three-dimensional simulations. Analytical formulas linking macroscopic parameters (Young's modulus, Poisson's ratio) to mesoscopic particle parameters for granular systems are derived based on statistically isotropic packings under small-strain isotropic stress conditions. By taking the derived analytical solutions as initial approximations, the gradient descent algorithm automatically obtains a reliable numerical estimation. The introduced framework is validated with several numerical cases including randomly distributed monodisperse and polydisperse packings. The results show that this hybrid method practically reduces the time for artificial trials and errors to obtain reasonable stiffness parameters. The proposed framework can also be extended to other parameter calibration problems in DEM.

Calibration method↗

SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers

Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, a pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.

60 APPLIED LIFE SCIENCES↗

Neural Learning Based Blind Source Separation for Detection of Material Defects in Pulsed Thermography Images

In this paper, we introduce a neural learning-based approach to blind source separation for detection of material flaws in pulsed thermography (PT) images. This approach can be used to detect internal defects (pores) in metallic Additively Manufactured (AM) materials. Such defects occur in high-strength alloys produced with direct laser sintering AM method for nuclear energy applications. Pulsed thermal imaging system utilizes a high intensity flash lamp to rapidly heat surface of sample, a high sensitivity infrared camera to capture data of surface temperature variations. The data cube obtained with PT (stack of surface temperature images at different times) can be analyzed with image processing algorithms to detect material defects. Compared with conventional nondestructive evaluation (NDE) methods, such as digital radiography and ultrasonic testing, the PT pulsed infrared thermal detection technique has advantages of one-sided non-contact measurements, fast processing of large sample areas captured in one image. Detection of small material defects requires finding features in thermal images, which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with the photothermic, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

Zhang, Xin↗

Adaptive Dynamic Digital Twin for Test Scenario Generation

Vehicle testing has been an important part in the development of both highly automated vehicles (HAV) and advanced driving assistant systems (ADAS). Obtaining a good representation of the Vehicle Under Test (VUT) is crucial for test scenario library generation (TSLG). Current vehicle testing methods often involve calibrating car-following models using vehicle trajectory data to create static representations that cannot be dynamically updated. For instance, when multiple vehicle trajectories are collected, it is difficult to automatically determine whether a new trajectory improves the model's representativeness or degrades its accuracy. In this paper, we introduce a dynamically updated digital twin modeling framework featuring an adaptive mechanism that evaluates new trajectory data. This mechanism can decide whether to incorporate newly collected data into the current model or create a separate digital twin model when the trajectory significantly differs from prior data. Vehicle location, speed, and acceleration extracted from the newly collected trajectory data are used to support the dynamic update decision. By integrating this digital twin model into the test library generation process, we demonstrate its ability to assist in generating test libraries while effectively handling newly collected data.

Chen, Hanlin [ORNL] (ORCID:0000000165087715)↗

CGSim: A Simulation Framework for Large Scale Distributed Computing Environment

Large-scale distributed computing infrastructures such as the Worldwide LHC Computing Grid (WLCG) require comprehensive simulation tools for evaluating performance, testing new algorithms, and optimizing resource allocation strategies. However, existing simulators suffer from limited scalability, hardwired algorithms, lack of real-time monitoring, and inability to generate datasets suitable for modern machine learning approaches. We present CGSim, a simulation framework for large-scale distributed computing environments that addresses these limitations. Built upon the validated SimGrid simulation framework, CGSim provides high-level abstractions for modeling heterogeneous grid environments while maintaining accuracy and scalability. Key features include a modular plugin mechanism for testing custom workflow scheduling and data movement policies, interactive real-time visualization dashboards, and automatic generation of event-level datasets suitable for AI-assisted performance modeling. We demonstrate CGSim’s capabilities through a comprehensive evaluation using production ATLAS PanDA workloads, showing significant calibration accuracy improvements across WLCG computing sites. Scalability experiments show near-linear scaling for multi-site simulations, with distributed workloads achieving 6 × better performance compared to single-site execution. The framework enables researchers to simulate WLCG-scale infrastructures with hundreds of sites and thousands of concurrent jobs within practical time budget constraints on commodity hardware.

Vatsavai, Sairam Sri [Brookhaven National Laborato↗

Automatic tuning of the Community Atmospheric Model CAM5.3 by using short-term hindcasts with an improved downhill simplex optimization method

Traditional trial-and-error tuning of uncertain parameters in global atmospheric General Circulation Models (GCM) is time consuming and subjective. This study explores the feasibility of automatic optimization of GCM parameters for fast physics by using short-term hindcasts. An automatic workflow is described and applied to the Community Atmospheric Model (CAM5) to optimize several parameters in its cloud and convective parameterizations. We show that the auto-optimization leads to 10 % reduction of the overall bias in CAM5, which is already a well calibrated model, based on a pre-defined metric that includes precipitation, temperature, humidity, and longwave/shortwave cloud forcing. The computational cost of the entire optimization procedure is about equivalent to about a single 12-year atmospheric model simulation. The tuning reduces the large underestimation in the CAM5 longwave cloud forcing by decreasing the threshold relative humidity and the sedimentation velocity of ice crystals in the cloud schemes; it reduces the overestimation of precipitation by increasing the adjustment time in the convection scheme. The physical processes behind the tuned model performance for each targeted field are discussed. Limitations of the automatic tuning are described, including the slight deterioration in some targeted fields that reflect the structural errors of the model. It is pointed out that automatic tuning can be a viable supplement to process-oriented model evaluations and improvement.

54 ENVIRONMENTAL SCIENCES↗