Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arrival time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

Orbital elements of the binary X-ray pulsar GX 301-2

X-ray outbursts from GX 301-2 were observed with Hakucho on two occasions during April and May 1982 and with Tenma in April 1984. Pulse arrival times measured with Hakucho were combined with those previously measured with Ariel 5 and SAS 3. The joint timing analysis of these data sets yields an orbital period of 41.5 days as the only acceptable solution; this is consistent with the period derived from the X-ray flaring events of the source. The orbital elements of the binary system, established from the joint timing analysis, are presented. The orbital solution suggests that all the peaks of X-ray flares observed during the past 10 yr occur at the orbital period, but consistently appear about 1.4 days before the time of periastron passage of the X-ray star.

Sato, N.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

A low-cost optical data acquisition system for vibration measurement

A low cost optical data acquisition system was designed to measure deflection of vibrating rotor blade tips. The basic principle of the new design is to record raw data, which is a set of blade arrival times, in memory and to perform all processing by software following a run. This approach yields a simple and inexpensive system with the least possible hardware. Functional elements of the system were breadboarded and operated satisfactorily during rotor simulations on the bench, and during a data collection run with a two-bladed rotor in the Lewis Research Center Spin Rig. Software was written to demonstrate the sorting and processing of data stored in the system control computer, after retrieval from the data acquisition system. The demonstration produced an accurate graphical display of deflection versus time.

Posta, S. J.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

Three-dimensional P and S wave velocity structures of southern Peru and their tectonic implications

Arrival times of compressional and shear (S) waves from microearthquakes recorded in 1981 by an 18-station regional array are used to study the three-dimensional velocity structure of the crust and upper mantle of the central Andes. The data suggest a crustal thickness of about 40 km beneath the coast, increasing to about 70 km beneath the Cordillera Occidental. The inverse correlation between the dip in the Moho and the dip of the slab may indicate a broad-scale causal relation between the two. S wave velocities in the mantle between 70 and 130 km depth above the 30-degree dipping slab are low, possibly indicating the presence of a partially melted asthenosphere that may be responsible for the magmatic activity recorded in southern Peru.

Cunningham, Paul S.↗

Gamma-ray burst localization by HEAO 3

The relative response of the five segments of the HEAO 3 gamma-ray-spectroscope anticoincidence shield (a 6.62-cm-thick 33.1-cm-OD 27.4-cm-high CsI cylinder) is used to estimate the directions of gamma-ray bursts on February 13, 1980 and September 29, 1979. The operation of the instrument and the data-analysis procedures are described, and the results are presented graphically. The 1980 event is located in an error box centered on alpha = 104.5 deg and delta = -15 deg (error box A of Atteia et al., 1987). The position of the 1979 event (alpha = 75 deg and delta = 40 deg) is shown to be consistent with ISEE 3 and Pioneer Venus Orbiter arrival times.

Schwartz, R. A.↗

Improved acoustic emission locations

A technique for locating acoustic emission in brittle rock specimens is described. An array of eight piezoelectric transducers was used to detect acoustic emission and to receive velocity measurement pulses. Axial and transverse velocities were calculated from the transmission data; the use of the velocity data to locate the acoustic emissions is discussed. Waveforms were recorded for about 140 acoustic emissions during the deformation of the Westerly granite specimen and about 100 acoustic emissions were located. The effect of transducer size and incident angle on apparent arrival times is evaluated using a lead zirconium titinate transducer bonded to a small brass rider with a curved surface matched to the brass specimen. The relation between location accuracy in various regions of the specimen and the geometry of the receiver array is studied. It is observed that for incidence angles away from the normal, the velocity appears to be higher than for normal incidences.

Getting, I. C.↗

A piloted simulator evaluation of a ground-based 4D descent advisor algorithm

A ground-based, four-dimensional (4D) descent-advisor algorithm is under development at NASA Ames Research Center. The algorithm combines detailed aerodynamic, propulsive, and atmospheric models with an efficient numerical integration scheme to generate 4D descent advisories. This paper investigates the ability of the 4D descent advisor algorithm to provide adequate control of arrival time for aircraft not equipped with on-board 4D guidance systems. A piloted simulation was conducted to determine the precision with which the descent advisor could predict the 4D trajectories of typical straight-in descents flown by airline pilots under different wind conditions. The effects of errors in the estimation of wind and initial aircraft weight were also studied. A description of the descent advisor as well as the results of the simulation studies are presented.

Green, Steven M.↗

Estimating Electron Content Of The Ionosphere

Method for estimation total electron content of ionosphere. Based on measurements of signals transmitted from global positioning satellites (GPS's). Ionospheric delays obtained by measuring differential arrival times of signals at two different frequencies. Since GPS observations cover certain regions of sky, location of space probe to be calibrated might not overlap GPS field of view. Certain assumptions made about behavior of ionosphere so total electron content estimated in any direction from receiver.

Lanyi, G. E.↗

Low-cost optical data acquisition system for blade vibration measurement

A low cost optical data acquisition system was designed to measure deflection of vibrating rotor blade tips. The basic principle of the new design is to record raw data, which is a set of blade arrival times, in memory and to perform all processing by software following a run. This approach yields a simple and inexpensive system with the least possible hardware. Functional elements of the system were breadboarded and operated satisfactorily during rotor simulations on the bench, and during a data collection run with a two-bladed rotor in the Lewis Research Center Spin Rig. Software was written to demonstrate the sorting and processing of data stored in the system control computer, after retrieval from the data acquisition system. The demonstration produced an accurate graphical display of deflection versus time.

Posta, Stephen J.↗

Energy dependent delay measurements of quasi-periodic oscillations in low-mass X-ray binaries

Results of Monte Carlo simulations of the Comptonization of photons in a finite spherical Comptonizing cloud are presented. The energy dependence of the arrival times of the Comptonized photons is very different for different input photon spectra. If the delays observed in the high-frequency QPO of Cyg X-2 and GX5-1 are the result of Comptonization, multichannel time-delay measurements may constrain the energy of the input photons and thus provide important information on the accretion process in low-mass X-ray binaries.

Wijers, R. A. M. J.↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

On the collapse and violent relaxation of protoglobular clusters

During the formation of stellar systems such as globular clusters, low-mass subcondensations which eventually form stars must retain a geometric size throughout the collapse process that is small compared to the characteristic distance separating them. If the local velocity dispersion of the subcondensations is small, the overall dimension of the system can decrease substantially before reaching a dynamical equilibrium state. The maximum collapse factor is deduced by examining the growth of the velocity dispersion and the spread in arrival times at the origin caused by local and global fluctuations. It is shown, analytically as well as in a series of N-body simulations, that the maximum reduction in the characteristic dimension of a system of N fragments with an initial homogeneous distribution subject to N exp 1/2 fluctuations is proportional to N exp 1/3. Direct physical collisions between low-mass subcondensations are therefore unlikely to occur in protoglobular clusters. The results are discussed in the context of fragmentation and violent relaxation.

Aarseth, S. J.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

Characteristics of type III bursts in the solar wind from simultaneous observations on board ISEE-3 and Voyager

The properties of solar type III bursts observed aboard ISEE-3 and Voyager that originate behind the sun are analyzed and compared to those originating on the near side. The measurement of the burst parameters and the correction for proximity effects are described. The diminution of flux densities, the increase of source sizes, the difference of source azimuths and elevations, the change of spectral properties, and the anomalous delays in burst arrival time at one spacecraft relative to another are determined. Many of the observations imply that the beaming of type III radiation is much more widespread at all frequencies than has been derived from statistical studies. The effective beam appears to consist of at least two components: a Gaussian core of half width about 60 deg, and a very broad halo that extends to 180 deg with an amplitude of a few percent.

Lecacheux, A.↗

Polarity establishment, morphogenesis, and cultured plant cells in space

Plant development entails an orderly progression of cellular events both in terms of time and geometry. There is only circumstantial evidence that, in the controlled environment of the higher plant embryo sac, gravity may play a role in embryo development. It is still not known whether or not normal embryo development and differentiation in higher plants can be expected to take place reliably and efficiently in the micro g space environment. It seems essential that more attention be given to studying aspects of reproductive biology in order to be confident that plants will survive seed to seed to seed in a space environment. Until the time arrives when successive generations of plants can be grown, the best that can be done is utilize the most appropriate systems and begin, piece meal, to accumulate information on important aspects of plant reproduction. Cultured plant cells can play an important role in these activities since they can be grown so as to be morphogenetically competent, and thus can simulate those embryogenic events more usually identified with fertilized eggs in the embryo sac of the ovule in the ovary. Also, they can be manipulated with relative ease. The extreme plasticity of such demonstrably totipotent cell systems provides a means to test environmental effects such as micro g on a potentially free-running entity. The successful manipulation and management of plant cells and propagules in space also has significance for exploitation of biotechnologies in space since such systems, perforce, are an important vehicle whereby many genetic engineering manipulations are achieved.

Krikorian, Abraham D.↗

High-resolution detectors for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of pulse-counting imaging array detectors designed specifically for astrophysical investigations in space. The MAMAs have a number of unique performance characteristics which make them particularly suitable for imaging and spectroscopy at ultraviolet and soft X-ray wavelengths. First, they employ 'solar blind' photocathodes eliminating the 'red leak' problem associated with solid state arrays such as the CCDs. Second, they operate with zero readout noise, yielding photon-statistics limited signals. Third, they utilize a random readout technique and can determine both the location of a detected photon and also its arrival time to an accuracy of the order of 100 ns. This paper gives an overview of the construction, mode of operation, and performance characteristics of the MAMA detectors and describes the current status of the development program.

Timothy, J. G.↗