Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

Efficiency optimization of a thermionic converter array

Intensive study of the outer planets of the solar system requires the use of nuclear power for electric propulsion of spacecraft. Among the power conversion devices being considered for this application are thermionic converters. This paper presents the results of computer modeling of thermionic converters to identify the major design variables and select an optimum size for each of the thermionic converters for the power conversion system under consideration. Among the variables investigated were electrical and thermal losses in electrodes, leads and heat chokes. Those elements which minimized the electrical losses tended to increase thermal losses and system weight. Overall mechanical design and relative positioning of components also had impacts on converter efficiency and the power subsystem weight. Numerical calculations were made using the computer heat transfer code SINDA coupled with electrical loss parameters. The results of the computations are presented in this paper.

Kuo, Y. S.↗

Dielectric breakdown in a dilute plasma: A 20 kilovolt limited study

A dielectric breakdown study was made of several materials proposed for high-voltage (16-kV) use on solar-cell arrays at space conditions. The tests were made in an argon plasma whose electron density and temperature approximately simulated conditions at an altitude of 300 km. The maximum voltage used was 20 kV. The results indicate that the breakdown voltages of the materials tested are larger than those quoted in the literature for dielectric between two metal electrodes.

Mckinzie, D. J., Jr.↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

On Machine Capacitance Dimensional and Surface Profile Measurement System

A program was awarded under the Air Force Machine Tool Sensor Improvements Program Research and Development Announcement to develop and demonstrate the use of a Capacitance Sensor System including Capacitive Non-Contact Analog Probe and a Capacitive Array Dimensional Measurement System to check the dimensions of complex shapes and contours on a machine tool or in an automated inspection cell. The manufacturing of complex shapes and contours and the subsequent verification of those manufactured shapes is fundamental and widespread throughout industry. The critical profile of a gear tooth; the overall shape of a graphite EDM electrode; the contour of a turbine blade in a jet engine; and countless other components in varied applications possess complex shapes that require detailed and complex inspection procedures. Current inspection methods for complex shapes and contours are expensive, time-consuming, and labor intensive.

Resnick, Ralph↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Mathematical modeling of novel porous transport layer architectures for proton exchange membrane electrolysis cells

Thin foil based porous transport layers (PTLs) that contain highly structured pore arrays have shown promise as anode PTLs in proton exchange membrane electrolysis cells. These novel PTLs, fabricated with advanced manufacturing techniques, produce thin, tunable, multifunctional layers with reduced flow and interfacial resistances and high thermal and electric conductivities. To further optimize their design, it is important to understand their fundamental impact on the transport of protons, electrons, and liquid/vapor mixtures in the electrode. In this work, we develop a two-dimensional multiphysics model to simulate the coupled electrochemistry and multiphase transport in an electrolysis cell operated with the novel PTL architecture. The results show that larger pores improve access of water to the anode catalyst layer, which is beneficial for both the oxygen evolution reaction and membrane hydration. Larger pore sizes also improve oxygen gas transport from the catalyst layer, because generated oxygen gas is forced to travel in-plane through the anode catalyst layer until it reaches a pore opening that is connected to a channel. The discussed results confirm that the proposed thin foil based PTLs are fundamentally different from conventional PTLs, such as felts or layered meshes. The model developed in this work also provides generalizable insight into fundamental PEMEC phenomena, such as the competition between liquid and gas phase transport, membrane hydration and water management, and nonuniform electrochemical reactions, which are processes relevant to all PEMEC designs.

25 ENERGY STORAGE↗

Electrochemical Reconstitution of Biomolecules for Applications as Electrocatalysts for the Bionanofuel Cell

Platinum-cored ferritins were synthesized as electrocatalysts by electrochemical biomineralization of immobilized apoferritin with platinum. The platinum cored ferritin was fabricated by exposing the immobilized apoferritin to platinum ions at a reduction potential. On the platinum-cored ferritin, oxygen is reduced to water with four protons and four electrons generated from the anode. The ferritin acts as a nano-scale template, a biocompatible cage, and a separator between the nanoparticles. This results in a smaller catalyst loading of the electrodes for fuel cells or other electrochemical devices. In addition, the catalytic activity of the ferritin-stabilized platinum nanoparticles is enhanced by the large surface area and particle size phenomena. The work presented herein details the immobilization of ferritin with various surface modifications, the electrochemical biomineralization of ferritin with different inorganic cores, and the fabrication of self-assembled 2-D arrays with thiolated ferritin.

Kim, Jae-Woo↗

Carbon Nanotube-Based Structural Health Monitoring Sensors

Carbon nanotube (CNT)-based sensors for structural health monitoring (SHM) can be embedded in structures of all geometries to monitor conditions both inside and at the surface of the structure to continuously sense changes. These CNTs can be manipulated into specific orientations to create small, powerful, and flexible sensors. One of the sensors is a highly flexible sensor for crack growth detection and strain field mapping that features a very dense and highly ordered array of single-walled CNTs. CNT structural health sensors can be mass-produced, are inexpensive, can be packaged in small sizes (0.5 micron(sup 2)), require less power than electronic or piezoelectric transducers, and produce less waste heat per square centimeter than electronic or piezoelectric transducers. Chemically functionalized lithographic patterns are used to deposit and align the CNTs onto metallic electrodes. This method consistently produces aligned CNTs in the defined locations. Using photo- and electron-beam lithography, simple Cr/Au thin-film circuits are patterned onto oxidized silicon substrates. The samples are then re-patterned with a CNT-attracting, self-assembled monolayer of 3-aminopropyltriethoxysilane (APTES) to delineate the desired CNT locations between electrodes. During the deposition of the solution-suspended single- wall CNTs, the application of an electric field to the metallic contacts causes alignment of the CNTs along the field direction. This innovation is a prime candidate for smart skin technologies with applications ranging from military, to aerospace, to private industry.

Wincheski, Russell↗

Grazing-Incidence Texture Tomography and Diffuse Reflectivity Tomography of an Organic Semiconductor Device Array

The use of grazing-incidence scattering methods for the characterization of 2D patterned organic thin films is limited due to the elongated 1D footprint of the X-ray beam on the sample. However, this characteristic feature can be turned into an advantage, when combined with tomographic reconstruction. In this pilot study we show, how the use of a chosen texture reflection and a diffuse reflectivity signal can each provide 2D images of the deposits, simultaneously revealing the organic film's crystal orientation and the location of the metal electrodes in a field-effect transistor structure from a single sequence of diffraction images.

36 MATERIALS SCIENCE↗

High Density Faraday Cup Array or Other Open Trench Structures and Method of Manufacture Thereof

A detector array and method for making the detector array. The detector array includes a substrate including a plurality of trenches formed therein, and a plurality of collectors electrically isolated from each other, formed on the walls of the trenches, and configured to collect charged particles incident on respective ones of the collectors and to output from the collectors signals indicative of charged particle collection. In the detector array, adjacent ones of the plurality of trenches are disposed in a staggered configuration relative to one another. The method forms in a substrate a plurality of trenches across a surface of the substrate such that adjacent ones of the trenches are in a staggered sequence relative to one another, forms in the plurality of trenches a plurality of collectors, and connects a plurality of electrodes respectively to the collectors.

Bower, Christopher A.↗

Vertically stacked photovoltaic and thermal solar cell

According to some embodiments, the present invention provides a novel photovoltaic solar cell system from photovoltaic modules that are vertically arrayed in a stack format using thin film semiconductors selected from among organic and inorganic thin film semiconductors. The stack cells may be cells that are produced in a planar manner, then vertically oriented in an angular form, also termed herein tilted, to maximize the light capturing aspects. The use of a stack configuration system as described herein allows for the use of a variety of electrode materials, such as transparent materials or semitransparent metals. Light concentration can be achieved by using fresnel lens, parabolic mirrors or derivatives of such structures. The light capturing can be controlled by being reflected back and forth in the photovoltaic system until significant quantities of the resonant light is absorbed. Light that passes to the very end and can be reflected back through the device by beveling or capping the end of the device with a different refractive index material, or alternatively using a reflective surface. The contacting between stacked cells can be done in series or parallel. According to some embodiments, the present invention uses a concentrator architecture where the light is channeled into the cells that contain thermal fluid channels (using a transparent fluid such as water) to absorb and hence reduce the thermal energy generation.

14 SOLAR ENERGY↗

Method of construction of a multi-cell solar array

The method of constructing a high voltage, low power, multicell solar array is described. A solar cell base region is formed in a substrate such as but not limited to silicon or sapphire. A protective coating is applied on the base and a patterned etching of the coating and base forms discrete base regions. A semiconductive junction and upper active region are formed in each base region, and defined by photolithography. Thus, discrete cells which are interconnected by metallic electrodes are formed.

Routh, D. E.↗

Process Produces Low-Secondary-Electron-Emission Surfaces

Textured carbon layer applied to copper by sputtering. Carbon surface characterized by dense, random array of needle-like spires or peaks that extend perpendicularly from local copper surface. Spires approximately 7 micrometers in height and spaced approximately 3 micrometers apart, on average. Copper substrate essentially completely covered by carbon layer, is tenacious and not damaged by vibration loadings representative of multistage depressed collector (MDC) applications. Process developed primarily to provide extremely low-secondary-electron-emission surface for copper for use as highefficiency electrodes in MDC's for microwave amplifier traveling-wave tubes (TWT's). Tubes widely used in space communications, aircraft, and terrestrial applications.

Curren, A. N.↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Host-Directed, Bioelectronic Immunomodulation for Protection Against Emerging Pathogens

Acute care of patients with severe infections often relies on systemic administration of pharmaceuticals and monitoring of complex physiological symptoms to identify immune system dysfunction, which can lead to increased mortality. Furthermore, determining disease-specific treatment plans often leads to a delay in patient care. To address this, we proposed an immune modulation system that electrically detects and responds to a patient’s immune system status, creating an agnostic means of treating illness and infection. Two pieces of hardware were developed for this task: a minimally-invasive sensor and a vagus nerve stimulator. Stimulation of the vagus nerve is known to modulate the immune system. The sensor is a microfabricated, silicon-based microneedle array capable of interfacing with interstitial fluid to detect small molecules such as inflammatory proteins (cytokines) and pharmaceuticals (vancomycin). Process optimization to manufacture the needles refined the silicon etch process, creating needle patches long enough to penetrate skin and reach interstitial fluid. The needles were tested for mechanical strength and stability, and did not shatter when inserted into skin models. The needles are coated with a thin film metal, turning them into electrodes for electrochemical sensing of our target molecules. We hybridized aptamers to the surface of the electrode to act as the sensing layer and were able to detect changes in the conformation of the aptamer electrochemically in the presence of the target molecule. The stimulator was a cuff electrode that encircled the vagus nerve. Rodent studies were conducted in which rodents were exposed to an inflammatory event and vagus nerve stimulation (VNS) was applied. It was demonstrated that optimized electrical stimulation of the vagus nerve created measurably different levels of cytokines in blood samples, and certain cytokines released during the inflammatory event were either upregulated or downregulated. In sum, this project successfully developed new platforms and technologies that can, with further development, enable better temporal insight into biomarker changes in the body, letting healthcare providers know of possible immune system dysfunction before they are detected physiologically. We also demonstrated the value of VNS and its possible use in treating immune system response to inflammation and illness.

59 BASIC BIOLOGICAL SCIENCES↗

High speed CMOS imager with motion artifact supression and anti-blooming

An image sensor includes pixels formed on a semiconductor substrate. Each pixel includes a photoactive region in the semiconductor substrate, a sense node, and a power supply node. A first electrode is disposed near a surface of the semiconductor substrate. A bias signal on the first electrode sets a potential in a region of the semiconductor substrate between the photoactive region and the sense node. A second electrode is disposed near the surface of the semiconductor substrate. A bias signal on the second electrode sets a potential in a region of the semiconductor substrate between the photoactive region and the power supply node. The image sensor includes a controller that causes bias signals to be provided to the electrodes so that photocharges generated in the photoactive region are accumulated in the photoactive region during a pixel integration period, the accumulated photocharges are transferred to the sense node during a charge transfer period, and photocharges generated in the photoactive region are transferred to the power supply node during a third period without passing through the sense node. The imager can operate at high shutter speeds with simultaneous integration of pixels in the array. High quality images can be produced free from motion artifacts. High quantum efficiency, good blooming control, low dark current, low noise and low image lag can be obtained.

Pain, Bedabrata↗