Heat Pipes

Phoenix Refrigeration Systems, Inc.'s heat pipe addition to the Phoenix 2000, a supermarket rooftop refrigeration/air conditioning system, resulted from the company's participation in a field test of heat pipes. Originally developed by NASA to control temperatures in space electronic systems, the heat pipe is a simple, effective, heat transfer system. It has been used successfully in candy storage facilities where it has provided significant energy savings. Additional data is expected to fully quantify the impact of the heat pipes on supermarket air conditioning systems.

Source record↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Building Start (SBS) (CRADA 480)

The idea of Smart Building Start (SBS) is to manage the on/off scheduling of HVAC equipment in buildings in an optimal way in order to achieve comfort conditions at the designated times with the minimal use of energy. This concept is also known as Optimal Start and it has typically been used in buildings to start up equipment based on predictions made for a representative (or average) zone in a building. This means that zones that could have waited longer to receive conditioned air are activated too early leading to unnecessary energy loss. The approach proposed in this project is to develop and implement a distributed version of optimal start that will consider the individual requirements of all treated zones. The developed control strategy will enable smart start of the central plant as well as further localized control over each individual zone by means of setpoint adjustment so that zones are not conditioned too early thereby reducing energy use compared to the current state of the art. This project is a collaboration between PNNL and Verdicity with the goal being to bring the research concept of SBS to commercialization. The SBS algorithm(s) will be implemented and hosted on the PNNL-developed open-platform VOLTTRON which will accelerate bringing the research to practice. It is anticipated that this project will lead to new IP surrounding the algorithm and its decentralized deployment. The project will also further demonstrate the success of VOLTRON as a flexible platform for implementation of innovative algorithms for improving energy efficiency in buildings. Previous studies on smart building start carried out by PNNL have indicated potential energy savings on the order of 10-15% for multi-zone buildings compared to conventional strategies. Verdicity currently has a number of customers who can benefit from the use of this technology. PNNL will work with Verdicity to identify any key gaps in the integrated software and jointly work to enhance and customize it for Verdicity and to integrate it with their existing products for use at their customers’ sites. The proposed work will help previously funded Federal research and development technology investments find their way into a viable commercial market.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Cold Climate Air Source Heat Pumps (ccASHPs) Technology

This report describes cold climate air source heat pump technology. Cold climate air source heat pumps (ccASHPs) are a variation of an existing air conditioning technology - heat pumps - that are designed to heat homes adequately in very cold weather (usually at or below 5 degrees F) and, as a secondary function, cool these homes during warm weather.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptive-wall wind-tunnel research at NASA-Ames Research Center

Adaptive wall wind tunnel research is summarized. Small scale two and three dimensional wind tunnel experiments and numerical experiments with a three dimensional adaptive wall simulator are included. A NACA 0012 airfoil was tested in a 25 by 13 cm slotted wall test section. Airflow through the test section walls was controlled by adjusting the pressures in segmented plenums. Interference free conditions were successfully attained in subsonic and transonic flows. For the three dimensional experiment, the 25 by 13 cm wind tunnel was modified to permit cross stream wall adjustments. The test model was a semispan wing mounted to one sidewall. Wall interference was substantially reduced at several angles of attack at Mach 0.60. A wing on wall configuration was also modeled in the numerical experiments. These flow simulations showed that free air conditions can be approximated by adjusting boundary conditions at only the floor and ceiling of the test section. No sidewall control was necessary. Typical results from these experiments are discussed.

Schairer, E. T.↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

A NUMERICAL STUDY OF REFRIGERANT LEAKAGE FROM A PROPANE-BASED REFRIGERATION SYSTEM

Low Global Warming Potential (GWP) refrigerants, e.g. Propane (R290) (GWP = 3) and R1234yf (GWP = 4), are becoming a popular choice among refrigeration and HVAC systems, such as vending machines and air conditioning. However, most of Low GWP refrigerants are flammable (ASHRAE class A2 or A3), so safety is a very important consideration when designing and deploying low GWP refrigerants-based equipment in buildings. In the event of a refrigerant leak, the flammability of low GWP refrigerants depends on the local concentration of the refrigerant within the vicinity of the leak. In addition, the low GWP refrigerants concentration is affected by the indoor air environment, such as air flow rate and temperature. In the present study, a computational fluid dynamics (CFD) model is developed to model the flow and temperature of air surrounding a propane-based refrigeration system, as well as the concentration of leaked low GWP refrigerants surrounding the refrigeration system. The model results reveal the concentration distribution of low GWP refrigerants within the building, and as a result, the flammable regions within the building can be identified. Moreover, different ventilation layouts will be tested using the model to improve the design of ventilation. The numerical model can assist in the design of ventilation systems to minimize flammable regions within buildings due to leakage of flammable refrigerants.

Zhang, Mingkan↗

Potential of a Plant Gas Exchange Mechanistic Model to Predict Plant Transpiration in Veggie on ISS

Plants are an essential part of long-duration space travel, as they enable food production and contribute to air revitalization through photosynthesis, and water recycling through transpiration. Understanding their growth mechanisms is essential to use them to sustain human life in space. In particular, gas exchange – e.g., CO2 absorption and water transpiration – are modified in microgravity because of the lack of buoyancy-driven convection, and in the long run, this could result in impaired plant growth. Water absorbed by the plants mainly depends on their size and on environmental conditions (air temperature, humidity and ventilation), but in microgravity watering plants is a delicate operation – too much water results in flooded roots and too little water leads in a few hours to wilted plants. This is regularly experienced in the Veggie system on ISS, which enables small-scale food production in microgravity since 2014. This presentation explores how a mechanistic model of plant gas exchange can help predict plant transpiration in Veggie and thus better predict daily watering. For each plant, inputs on canopy leaf area (acquired with daily photos), air temperature and relative humidity in the plant compartment, as well as airspeed at the top of its canopy enable accurate predictions of transpiration in microgravity. This brings a better understanding of water movement through the plant in microgravity in relation to ventilation and plant size and would result in easier management of plant watering in Veggie. Ultimately, this work could be applied to any space crop production in microgravity and be used for water management and yield predictions. This work was funded by NASA Space Biology through NASA postdoctoral program / USRA.

Lucie Poulet↗

Potential of a Plant Gas Exchange Mechanistic Model to Predict Plant Transpiration in Veggie on ISS

Plants are an essential part of long-duration space travel, as they enable food production and contribute to air revitalization through photosynthesis, and water recycling through transpiration. Understanding their growth mechanisms is essential to use them to sustain human life in space. In particular, gas exchange – e.g., CO2 absorption and water transpiration – are modified in microgravity because of the lack of buoyancy-driven convection, and in the long run, this could result in impaired plant growth. Water absorbed by the plants mainly depends on their size and on environmental conditions (air temperature, humidity and ventilation), but in microgravity watering plants is a delicate operation – too much water results in flooded roots and too little water leads in a few hours to wilted plants. This is regularly experienced in the Veggie system on ISS, which enables small-scale food production in microgravity since 2014. This presentation explores how a mechanistic model of plant gas exchange can help predict plant transpiration in Veggie and thus better predict daily watering. For each plant, inputs on canopy leaf area (acquired with daily photos), air temperature and relative humidity in the plant compartment, as well as airspeed at the top of its canopy enable accurate predictions of transpiration in microgravity. This brings a better understanding of water movement through the plant in microgravity in relation to ventilation and plant size and would result in easier management of plant watering in Veggie. Ultimately, this work could be applied to any space crop production in microgravity and be used for water management and yield predictions. This work was funded by NASA Space Biology through NASA postdoctoral program / USRA.

Lucie Poulet↗

Gateway Integrated Environmental Control and Life Support System (ECLSS) Overview and Status

The Gateway comprised of modules provided by commercial and international partners will be a lunar orbiting platform that is a critical element in the Moon to Mars architecture. Of the 4 modules that comprise the Gateway, the core Environmental Control and Life Support System (ECLSS) is provided by the Habitation and Logistics Outpost (HALO) module provided by NASA, and the International Habitat (I-Hab) provided by the European Space Agency (ESA) with the ECLSS provided by the Japanese Space Agency (JAXA). These modules work together to provide pressure control, air revitalization, and air conditioning capabilities for the Gateway integrated habitable volumes and attached visiting vehicles during open hatch crewed operations. Individually, they maintain the internal atmosphere during the long periods of dormancy between crewed operations to support payload operations and ensure a safe environment when the crew returns. Additionally, NASA bolsters crew survivability by providing government furnished equipment (GFE) to support crew survival in the face of catastrophic hazards (such as fire or a cabin air leak) until the Gateway stack reaches a point in the orbit where crew can safely abort on Orion. This paper explains the key driving requirements, architecture, and development status of the Gateway ECLSS.

Gateway↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.