Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XFELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ultrafast x-ray diffraction of high-pressure phases in dynamically compressed TiO 2

Here, we investigate the high-pressure polymorphism of Ti⁢O 2 under laser-shock compression from 54(5) to 137(7) GPa using in situ femtosecond x-ray diffraction. Our results provide experimental evidence of the 𝑃⁢𝑐⁢𝑎⁢2 1 -type distorted fluorite structure formed from polycrystalline Ti⁢O 2 dynamically compressed to 54(5) GPa. Upon higher compression, we observe the direct formation of the ninefold coordinated F⁡e 2 ⁢P-type phase at 68(4) and 78(3) GPa in polycrystalline and [001]-oriented Ti⁢O 2 , respectively. This represents an unprecedented 100 GPa reduction in the shock synthesis pressure of the F⁡e 2⁢ P-type structure relative to quasihydrostatic loading conditions. On pressure release, the F⁡e 2⁢ P-type phase transforms to the α-Pb⁢O 2 structure and, at later times, reverts to rutile. Thus, the rutile →F⁡e 2⁢ P and α-Pb⁢O 2 →rutile transformations are both observed to occur on nanosecond timescales. Our results highlight the unique ability of high-strain-rate uniaxial compression to synthesize novel high-pressure phases and also indicate the importance of in situ atomic-level probes in developing pressure-temperature phase diagrams.

Crystal structures↗

Measurement of turbulent velocity and bounds for thermal diffusivity in laser shock compressed foams by x-ray photon correlation spectroscopy

Experimental benchmarking of transport coefficients under extreme conditions is required for validation of differing theoretical models. To date, measurement of transport properties of dynamically compressed samples remains a challenge with only a limited number of studies able to quantify transport in high pressure and temperature matter. x-ray photon correlation spectroscopy utilizes coherent x-ray sources to measure time correlations of density fluctuations, thus providing measurements of length and timescale-dependent transport properties. Here, we present a first-of-a-kind experiment to conduct x-ray photon correlation spectroscopy in laser shock compression experiments. We report measurement of the turbulent velocity in the wake of a laser driven supersonic shock and place an upper bound on thermal diffusivity in a solid density plasma on nanosecond timescales.

High-energy-density plasmas↗

Shock-driven amorphization and melting in Fe 2 O 3

We present measurements on Fe 2⁢ O 3 amorphization and melt under laser-driven shock compression up to 209(10) GPa via time-resolved in situ x-ray diffraction. At 122(3) GPa, a diffuse signal is observed indicating the presence of a noncrystalline phase. Structure factors have been extracted up to 182(6) GPa showing the presence of two well-defined peaks. A rapid change in the intensity ratio of the two peaks is identified between 145(12) and 151(12) GPa, indicative of a phase change. The noncrystalline diffuse scattering is consistent with shock amorphization of Fe 2 ⁢O 3 between 122(3) and 145(12) GPa, followed by an amorphous-to-liquid transition above 151(12) GPa. Upon release, a noncrystalline phase is observed alongside crystalline α–Fe 2⁢ O 3 . The extracted structure factor and pair distribution function of this release phase resemble those reported for Fe 2 ⁢O 3 melt at ambient pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amplification of laser imprint in the presence of strong, externally imposed, target-normal magnetic fields

Here, an experiment was performed on the OMEGA EP Laser System to investigate the effects of magnetic fields on laser imprint. A 30 µ⁢m thick CH target was driven by a single beam delivering 3.0 kJ of UV energy in a 5 ns square pulse without smoothing by spectral dispersion. The Rayleigh-Taylor amplification of this beam's imprint on the target surface was monitored using face-on gated x-ray radiography from a Gd backlighter. Magnetic fields of up to 45 T were applied normal to the target surface. Analysis of the resulting radiographs shows a 60 ± 13% increase in the spectrally resolved surface perturbation amplitudes, consistent at all times and for all unsaturated frequencies. This consistency indicates that the increase in perturbation amplitudes was due to a change in the initial amplitudes rather than Rayleigh-Taylor growth. This is supported by the trajectory of individual modes and the inferred time-averaged perturbation growth rates. Laser imprint is therefore inferred to have increased due to strong magnetic fields that remain in the conduction zone of the target, suppressing off-axis electron motion and limiting the effects of thermal smoothing.

direct drive↗

Co-flow injection for serial crystallography at X-ray free-electron lasers

Serial femtosecond crystallography (SFX) is a powerful technique that exploits X-ray free-electron lasers to determine the structure of macromolecules at room temperature. Despite the impressive exposition of structural details with this novel crystallographic approach, the methods currently available to introduce crystals into the path of the X-ray beam sometimes exhibit serious drawbacks. Samples requiring liquid injection of crystal slurries consume large quantities of crystals (at times up to a gram of protein per data set), may not be compatible with vacuum configurations on beamlines or provide a high background due to additional sheathing liquids present during the injection. Proposed and characterized here is the use of an immiscible inert oil phase to supplement the flow of sample in a hybrid microfluidic 3D-printed co-flow device. Co-flow generation is reported with sample and oil phases flowing in parallel, resulting in stable injection conditions for two different resin materials experimentally. A numerical model is presented that adequately predicts these flow-rate conditions. The co-flow generating devices reduce crystal clogging effects, have the potential to conserve protein crystal samples up to 95% and will allow degradation-free light-induced time-resolved SFX.

3D printing↗

Toward a fully coherent tender and hard X-ray free-electron laser via cascaded EEHG in fourth-generation synchrotron light sources

Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.

36 MATERIALS SCIENCE↗

High-luminosity meV-resolution single-shot hard X-ray spectrograph for cavity-based X-ray free-electron lasers

Cavity-based X-ray free-electron lasers (CBXFELs) represent a possible realization of fully coherent hard X-ray sources having high spectral brilliance along with a narrow spectral bandwidth of ∼1–50 meV, a high repetition pulse rate of ∼1 MHz, and good stability. A diagnostic tool is required to measure CBXFEL spectra with meV resolution and high luminosity on a shot-to-shot basis. We have designed a high-luminosity single-shot hard X-ray spectrograph that images 9.831 keV X-rays in a ∼200 meV spectral window with a spectral resolution of a few meV. The spectrograph is designed around angular dispersion of X-rays in Bragg diffraction from crystals. It operates close to design specifications, exhibiting a linear dispersion rate of ∼1.4 µm meV −1 and a ∼200 meV window of high-fidelity spectral imaging. The experimentally demonstrated spectral resolution is ∼20 meV; this resolution is twice as low as expected from theory primarily because the spectrograph is highly sensitive to crystal angular instabilities. The experiment was performed at the bending magnet X-ray optics testing beamline 1-BM at the Advanced Photon Source.

Bragg diffraction↗

An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser

An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Macromolecular phasing using diffraction from multiple crystal forms

A phasing algorithm for macromolecular crystallography is proposed that utilizes diffraction data from multiple crystal forms – crystals of the same molecule with different unit-cell packings (different unit-cell parameters or space-group symmetries). The approach is based on the method of iterated projections, starting with no initial phase information. The practicality of the method is demonstrated by simulation using known structures that exist in multiple crystal forms, assuming some information on the molecular envelope and positional relationships between the molecules in the different unit cells. With incorporation of new or existing methods for determination of these parameters, the approach has potential as a method for ab initio phasing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep residual networks for crystallography trained on synthetic data

The use of artificial intelligence to process diffraction images is challenged by the need to assemble large and precisely designed training data sets. To address this, a codebase called Resonet was developed for synthesizing diffraction data and training residual neural networks on these data. Here, two per-pattern capabilities of Resonet are demonstrated: (i) interpretation of crystal resolution and (ii) identification of overlapping lattices. Resonet was tested across a compilation of diffraction images from synchrotron experiments and X-ray free-electron laser experiments. Crucially, these models readily execute on graphics processing units and can thus significantly outperform conventional algorithms. While Resonet is currently utilized to provide real-time feedback for macromolecular crystallography users at the Stanford Synchrotron Radiation Lightsource, its simple Python-based interface makes it easy to embed in other processing frameworks. This work highlights the utility of physics-based simulation for training deep neural networks and lays the groundwork for the development of additional models to enhance diffraction collection and analysis.

36 MATERIALS SCIENCE↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

TBD

Please check the README.txt file from the supplementary files for more information about the dataset.

CXI↗