Fluoroscopic tomography

A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.

Baily, N. A.↗

Phase Contrast X-ray Imaging of Shuttle Insulating Foam

X-ray radiation has been widely used for imaging applications since Rontgen first discovered X-rays over a century ago. Its large penetration depth makes it ideal for the nondestructive visualization of internal structure of materials or objects unobtainable otherwise. Currently widely used nondestructive evaluation (NDE) tools-X-ray radiography and tomography are absorption-based, and work well in highly absorbing materials where density or composition variations due to internal structure or defects are high enough to be spatially distinguished in terms of absorption contrast. However, in many cases where materials such as insulating foam are light-weight, the conventional absorption-based X-ray methods for NDE become less effective. Indeed, the low-density shuttle insulating foam used for flight mission poses a great challenge to the standard NDE tools in that the absorption contrast arising from internal defects of such a low- density material is either weak or indistinguishable. In this presentation, the latest progress in phase contrast X-ray imaging of internal defects of insulating foam will be presented and discussed, demonstrating new opportunities to solve challenging issues involved in advanced materials development and processing for space exploration.

Hu, Zhengwei↗

X-ray Diffraction Studies of Single-Crystal Materials for Broad Battery Applications

Single-crystal materials have attracted growing interest in battery research due to their well-defined crystallographic orientation, absence of grain boundaries, and enhanced mechanical and electrochemical stability. This Review provides a comprehensive overview of recent advances in the synthesis, structural evolution, and performance optimization of single-crystal electrodes and solid electrolytes. Particular focus is placed on the application of advanced X-ray diffraction (XRD) techniques, including operando synchrotron diffraction, reciprocal space mapping, and Bragg coherent diffraction imaging, which have enabled in-depth investigations of lattice strain, cation disorder, phase transitions, and defect formation. Representative case studies across Ni-rich layered oxides, spinel-type cathodes, and garnet-based electrolytes are examined to highlight the structural features unique to single crystals. Additionally, the synergistic integration of XRD with machine learning, tomography, and spectroscopy is discussed as a powerful direction for real-time analysis and predictive modeling. Furthermore, these insights provide critical guidance for the rational design of high-performance single-crystal materials in lithium, sodium, and solid-state battery systems.

25 ENERGY STORAGE↗

Kronos: A Multiwavelength Observatory for Mapping Accretion-Driven Sources

Kronos is a multiwavelength observatory proposed as a NASA Medium Explorer. Kronos is designed to make use of the natural variability of accreting sources to create microarcsecond-resolution maps of the environments of supermassive black holes in active galaxies and stella-size black holes in binary systems and to characterize accretion processes in Galactic compact binaries. Kronos will obtain broad energy range spectroscopic data with co-aligned X-ray, ultraviolet, and optical spectrometers. The high-Earth orbit of Kronos enables well-sampled, high time-resolution observations, critical for the innovative and sophisticated methods that are used to understand the accretion flows, mass outflows, jets, and other phenomena found in accreting sources. By utilizing reverberation mapping analysis techniques, Kronos produces advanced high-resolution maps of unprecedented resolution of the extreme environment in the inner cores of active galaxies. Similarly, Doppler tomography and eclipse mapping techniques characterize and map Galactic binary systems, revealing the details of the physics of accretion processes in black hole, neutron star, and white dwarf binary systems. The Kronos instrument complement, sensitivity, and orbital environment make it suitable to aggressively address time variable phenomena in a wide range of astronomical objects from nearby flare stars to distant galaxies.

Peterson, Bradley M.↗

Taking three-dimensional x-ray diffraction (3DXRD) from the synchrotron to the laboratory scale

Three-dimensional x-ray diffraction (3DXRD), a rotating x-ray diffraction technique, is a powerful tool for studying the micromechanical behavior of polycrystalline materials, capable of measuring the volume, position, orientation, and strain of thousands of grains simultaneously. However, its application has been historically limited to synchrotron facilities. Here, we present the first demonstration of laboratory-scale 3DXRD (Lab-3DXRD) using a liquid-metal-jet source. Lab-3DXRD achieves accuracy comparable to synchrotron-based 3DXRD, as validated against laboratory diffraction contrast tomography (LabDCT) and synchrotron-3DXRD. Over 96% of the grains detected with Lab-3DXRD are cross-validated, particularly for coarse grains (> ~60 μm), while the results suggest that finer grains should be accessible by taking advantage of high-efficiency detectors. We further demonstrate that its sensitivity to finer grains is enhanced by incorporating pre-characterization into the analysis. This study establishes Lab-3DXRD as a practical alternative to synchrotron techniques, making 3DXRD accessible to a wider range of academic and industrial researchers.

characterization and analytical techniques↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) Overview

Future lunar surface missions require construction materials that can be manufactured in situ using lo-cal resources while operating under extreme environmental conditions. Many Lunar material demands can be solved solely with regolith by compacting or sintering. And yet past Lunar missions rely on polymeric materials, and sustained Lunar missions must reduce Earth-supplied polymers dependence. Dual-cure (Ultraviolet (UV) and thermal) polymer-regolith composites offer a promising pathway by leveraging solar UV radiation, moderate thermal in-put, and regolith. Mission mass limits, power availability and energy constraints on the lunar surface further motivate low-energy processing and curing strategies for surface construction materials. The Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) project has successfully synthesized and demonstrated dual-cure photopolymer resins derivable from in-situ resources [3]. Morphological, thermal, and mechanical characterization show that the newly formulated UV curable resin systems integrates well with lunar regolith simulants. Processing and chemistry changes, and computational analysis advanced the composite design. X-ray CT scanned and computational analysis demonstrate that resin, regolith and additives are well incorporated. The large fraction of regolith, 95% by mass, large char yield (82% mass), low thermal conductivity (0.26 W/m/K), confirm this material as a promising high-performance thermal and structural material.

thermal conductivity↗

Characterization of microgravity effects on bone structure and strength using fractal analysis

The effect of micro-gravity on the musculoskeletal system has been well studied. Significant changes in bone and muscle have been shown after long term space flight. Similar changes have been demonstrated due to bed rest. Bone demineralization is particularly profound in weight bearing bones. Much of the current techniques to monitor bone condition use bone mass measurements. However, bone mass measurements are not reliable to distinguish Osteoporotic and Normal subjects. It has been shown that the overlap between normals and osteoporosis is found for all of the bone mass measurement technologies: single and dual photon absorptiometry, quantitative computed tomography and direct measurement of bone area/volume on biopsy as well as radiogrammetry. A similar discordance is noted in the fact that it has not been regularly possible to find the expected correlation between severity of osteoporosis and degree of bone loss. Structural parameters such as trabecular connectivity have been proposed as features for assessing bone conditions. In this report, we use fractal analysis to characterize bone structure. We show that the fractal dimension computed with MRI images and X-Ray images of the patella are the same. Preliminary experimental results show that the fractal dimension computed from MRI images of vertebrae of human subjects before bedrest is higher than during bedrest.

Acharya, Raj S.↗

Pore-scale visualization of natural hydrate-bearing sediments

Accurate modeling of gas hydrate reservoir productivity and geomechanical risks associated with subsurface dissociation of natural gas hydrates (NGH) requires the determination of model parameters through physical testing on natural hydrate-bearing sediments (HBS). This involves investigating the hydro-mechanical behavior of undisturbed hydrate samples from nature under in situ conditions using pressure core characterization and analysis, which provides a unique opportunity for research. By employing state-of-the-art micro computed tomography imagery on cryogenically preserved, hydrate-bearing sediment samples, we can determine hydrate saturation as well as permeability with and without the presence of hydrates in the sediment. Furthermore, utilizing a machine learning based image segmentation technique, it is possible to extract pore space and grain information. Subsections of the entire image volume were used to determine anisotropic permeabilities using a finite-difference method Stokes solver (FDMSS). Additionally, permeability measurements on whole pressure and temperature preserved hydrate-bearing core were analyzed by utilizing the National Energy Technology Laboratory’s (NETL) Pressure Core Characterization and X-ray CT Visualization Tool (PCXT) to manipulate, cut, and analyze pressure preserved sediment. Permeabilities were measured under a broad range of vertical stress states to simulate expected pressure changes during production scenarios, and the results show that permeabilities derived from images are in agreement with those from traditional core derived experiments. The collected stress-dependent permeability, permeability anisotropy, and corresponding gas hydrate saturations provide valuable input into numerical simulations of reservoir productivity. These properties have been proven to be key parameters determining a long-term reservoir response under depressurization.

Liu, Mengwei [Oak Ridge Institute for Science and ↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Lunar and Planetary Science XXXV: Astrobiology

The presentations in this session are: 1. A Prototype Life Detection Chip 2. The Geology of Atlantis Basin, Mars, and Its Astrobiological Interest 3. Collecting Bacteria Together with Aerosols in the Martian Atmosphere by the FOELDIX Experimental Instrument Developed with a Nutrient Detector Pattern: Model Measurements of Effectivity 4. 2D and 3D X-ray Imaging of Microorganisms in Meteorites Using Complexity Analysis to Distinguish Field Images of Stromatoloids from Surrounding Rock Matrix in 3.45 Ga Strelley Pool Chert, Western Australia 4. Characterization of Two Isolates from Andean Lakes in Bolivia Short Time Scale Evolution of Microbiolites in Rapidly Receding Altiplanic Lakes: Learning How to Recognize Changing Signatures of Life 5. The Effect of Salts on Electrospray Ionization of Amino Acids in the Negative Mode 6. Determination of Aromatic Ring Number Using Multi-Channel Deep UV Native Fluorescence 7. Microbial D/H Fractionation in Extraterrestrial Materials: Application to Micrometeorites and Mars 8. Carbon Isotope Characteristics of Spring-fed Iron-precipitating Microbial Mats 9. Amino Acid Survival Under Ambient Martian Surface UV Lighting Extraction of Organic Molecules from Terrestrial Material: Quantitative Yields from Heat and Water Extractions 10. Laboratory Detection and Analysis of Organic Compounds in Rocks Using HPLC and XRD Methods 11. Thermal Decomposition of Siderite-Pyrite Assemblages: Implications for Sulfide Mineralogy in Martian Meteorite ALH84001 Carbonate Globules 12. Determination of the Three-Dimensional Morphology of ALH84001 and Biogenic MV-1 Magnetite: Comparison of Results from Electron Tomography and Classical Transmission Electron Microscopy 13. On the Possibility of a Crypto-Biotic Crust on Mars Based on Northern and Southern Ringed Polar Dune Spots 14. Comparative Planetology of the Terrestrial Inner Planets: Implications for Astrobiology 15. A Possible Europa Exobiology 16. A Possible Biogeochemical Model for Titan

Source record↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Bisphosphonate as a Countermeasure to Space Flight-Induced Bone Loss

The purpose of this research is to determine whether anti-resorptive pharmaceuticals such as bisphosphonates, in conjunction with the routine in-flight exercise program, will protect ISS crewmembers from the regional decreases in bone mineral density and bone strength and the increased renal stone risk documented on previous long-duration space flights [1-3]. Losses averaged ~ 1 to 2 percent per month in such regions as the lumbar spine and hip. Although losses showed significant heterogeneity among individuals and between bones within a given subject, space flight-induced bone loss was a consistent finding. More than 90 percent of astronauts and cosmonauts on long-duration flights (average 171 days) aboard Mir and the ISS, had a minimum 5 percent loss in at least one skeletal site, 40 percent of them had a 10 percent or greater loss in at least one skeletal site, and 22 percent of the Mir cosmonauts experienced a 15 to 20 percent loss in at least one site. These losses occurred even though the crewmembers performed time-consuming in-flight exercise regimens. Moreover, a recent study of 16 ISS astronauts using quantitative computed tomography (QCT) demonstrated trabecular bone losses from the hip averaging 2.3 percent per month [4]. These losses were accompanied by significant losses in hip bone strength that may not be recovered quickly [5]. This rapid loss of bone mass results from a combination of increased and uncoupled remodeling, as demonstrated by increased resorption with little or no change in bone formation markers [6-7]. This elevated remodeling rate likely affects the cortical and trabecular architecture and may lead to irreversible changes. In addition to bone loss, the resulting hypercalciuria increases renal stone risk. Therefore, it is logical to attempt to attenuate this increased remodeling with anti-resorption drugs such as bisphosphonates. Success with alendronate was demonstrated in a bed rest study [8]. This work has been extended to space flight and two dosing regimens: 1) an oral dose of 70 mg of alendronate taken weekly during flight or 2) a single intravenous (IV) dose of 4 mg of zoledronic acid given several weeks before flight. Currently the study is focusing on the oral option because of NASA s safety concerns with the IV-administered drug. The protocol requests 10 male or female crewmembers on ISS flights of 90 days or longer. Controls are 16 previous ISS crewmembers with QCT scans of the hip performed by these same investigators. The primary outcome measure for this study is hip trabecular bone mineral density measured by QCT, but other measures of bone mass are performed including peripheral QCT (pQCT) and dual-energy x-ray absorptiometry. Serum and urinary bone markers and renal stone risk measured before, during, and after flight are included. Postflight data are currently being collected from 2 ISS crewmembers. Two additional crewmembers will return this spring after ~6-month missions. To date no untoward effects have been encountered.

Spector, Elisabeth↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Echo Tomography of Hercules X-1: Mapping the Accretion Disc with RXTE and HST

A paper based on the RXTE results contents the following and are ready for submission to ApJ: "Possible Detection of Companion Star Reflection from Hercules X-1 with RXTE". A paper combining July 1998 and July 1999 observations (including the RXTE results for both years) is nearly ready for submission to ApJ: The July 1998 and July 1999 Multiwavelength Campaigns on Hercules X-I/HZ Herculis. The July 1999 observations took place during an anomalous X-ray low state and the RXTE and EUVE data are consistent with X_ray reflected from the surface of the companion star.

Vrtilek, S.↗

Segmenting Images for a Better Diagnosis

NASA's Hierarchical Segmentation (HSEG) software has been adapted by Bartron Medical Imaging, LLC, for use in segmentation feature extraction, pattern recognition, and classification of medical images. Bartron acquired licenses from NASA Goddard Space Flight Center for application of the HSEG concept to medical imaging, from the California Institute of Technology/Jet Propulsion Laboratory to incorporate pattern-matching software, and from Kennedy Space Center for data-mining and edge-detection programs. The Med-Seg[TM] united developed by Bartron provides improved diagnoses for a wide range of medical images, including computed tomography scans, positron emission tomography scans, magnetic resonance imaging, ultrasound, digitized Z-ray, digitized mammography, dental X-ray, soft tissue analysis, and moving object analysis. It also can be used in analysis of soft-tissue slides. Bartron's future plans include the application of HSEG technology to drug development. NASA is advancing it's HSEG software to learn more about the Earth's magnetosphere.

Source record↗

Analysis of Iron Meteorites Using Computed Tomography and Electron-probe Microanalysis

Computed tomography (CT) imaging and electron-probe microanalysis (EPMA) have been used to study samples of the Mundrabilla and Colomera iron meteorites in order to perform structural, textural, and mineralogical analysis. Both gamma-ray (Co-60 source, essentially monochromatic 1.25MeV avg.) and x-ray (420 KeV, continuous) sources have been used, with effective resolution of approximately 1 mm and 0.25 mm, respectively. The gamma-ray source provides approx. 15 cm penetration through steel and is used for larger samples, whereas the x-ray source provides superior resolution at reduced penetration but exhibits beam hardening artifacts. Here we present a combined approach where CT and EPMA imaging and microanalysis aid in the identification of structural and compositional features in iron meteorites.