Understanding the Reactivity of Lunar Dust for Future Lunar Missions

During the Apollo missions, dust was found to cause numerous problems for various instruments and systems. Additionally, the dust may have caused momentary health issues for some of the astronauts. Therefore, the plan to resume robotic and manned missions to the Moon in the next decade has led to a renewed interest in the properties of lunar dust, ranging from geological to chemical to toxicological. An important property to understand is the reactivity of the dust particles. Due to the lack of an atmosphere on the Moon, there is nothing to protect the lunar soil from ultraviolet radiation, solar wind, and meteorite impacts. These processes could all serve to activate the soil, or produce reactive surface species. On the Moon, these species can be maintained for millennia without oxygen or water vapor present to satisfy the broken bonds. Unfortunately, the Apollo dust samples that were returned to Earth were inadvertently exposed to the atmosphere, causing them to lose their reactive characteristics. In order to aid in the preparation of mitigation techniques prior to returning to the Moon, we measured the ability of lunar dust, lunar dust simulant, and quartz samples to produce hydroxyl radicals in solution[1]. As a first approximation of meteorite impacts on the lunar surface, we ground samples using a mortar and pestle. Our initial studies showed that all three test materials (lunar dust (62241), lunar dust simulant (JSC-1Avf), and quartz) produced hydroxyl radicals after grinding and mixing with water. However, the radical production of the ground lunar dust was approximately 10-fold and 3-fold greater than quartz and JSC-1 Avf, respectively. These reactivity differences between the different samples did not correlate with differences in specific surface area. The increased reactivity produced for the quartz by grinding was attributed to the presence of silicon- or oxygen-based radicals on the surface, as had been seen previously[2]. These radicals may also play a part in the reactivity of the lunar dust and lunar simulant. However, other factors would seem to be required to account for the greatly increased reactivity of the lunar soil. It was proposed that nanometer-size Fe 0 (zero valent) particles in the lunar soil might play a role, as they are not present in quartz or lunar dust simulant. The present work has been performed with the aim of understanding the origin of the considerable reactivity of lunar dust[3]. We have ground 8 lunar soils of varying maturity and source (highland or mare) and measured the hydroxyl-radical production and decay of the reactivity. It was determined that there is a direct correlation between the reactivity and the amount of nanophase metallic iron particles (as a function of soil maturity, I s/FeO, in which Is is the amount of iron present as nanophase iron particles present and FeO is the total iron content) in the samples; thus, the highland soils, with their lesser total FeO content, are less reactive than ground mare soils. Additionally, grinding of nanophase iron simulant [4] showed reactivity in line with the lunar soils and much greater than lunar dust simulant or quartz. Studies aimed at determining the time required to deactivate the reactive soils in a habitable environment showed that the average time to reach 50% of the initial reactivity was approximately 3.5 hours. However, even after one week, none of the soils had returned completely to its unground level of reactivity. In contrast to the reactivity results, there was no obvious correlation between the maturity of the soil and its deactivation time. These results provide the first chemical reactivity and persistence values as an important property of lunar soils, data that is paramount as mankind prepares to return to the Moon.

Wallace, William↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the ARBI team validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. In addition to completing validation activities, this project looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. Based on these datasets, we conclude that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws. This has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of a Hot Water Distribution Model Using Laboratory and Field Data

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the Building America research team ARBI validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. This project also looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. The team concluded that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws, which has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of Ducted HPWH on Space-Conditioning and Water Heating Energy Use -- Central Florida Lab Home

The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PLATFORM for Product Launch

Pecan Street Inc. (PSI) and its partners set out in 2017 to validate the PLATFORM for Product Launch, a new model for improving the effectiveness of investments in clean energy technologies and accelerating market entry of disruptive technologies. In partnership with a newly formed Innovation Advisory Council, PSI recruited fourteen companies with new hardware-based technologies that enable or create clean energy opportunities. Pecan Street carried out product evaluations and conducted market research with stakeholders and target customers to develop recommendations on product optimization opportunities for all companies, and created third party performance evaluation reports that include environmental metrics, such as water and energy savings potential, to assist in creating investment confidence and to unlock additional sources of funding, such as impact investments. Pecan Street set-up the product testing environment, performed small-batch field testing, and provided a verified third-party performance report on the product of twelve companies. PSI Street and its partners leveraged the performance evaluations and insights from the newly formed PRI toolkit to raise over $1.5M across five companies, and garner interest for private sector adoption of the PLATFORM for Product Launch.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Turbine endwall two-cylinder program

Progress is reported in an effort to study the three dimensional separation of fluid flow around two isolated cylinders mounted on an endwall. The design and performance of a hydrogen bubble generator for water tunnel tests to determine bulk flow properties and to measure main stream velocity and boundary layer thickness are described. Although the water tunnel tests are behind schedule because of inlet distortion problems, tests are far enough along to indicate cylinder spacing, wall effects and low Reynolds number behavior, all of which impacted wind tunnel model design. The construction, assembly, and operation of the wind tunnel and the check out of its characteristics are described. An off-body potential flow program was adapted to calculate normal streams streamwise pressure gradients at the saddle point locations.

Langston, L. S.↗

Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.

Cardenas, Henry↗

Building America Case Study: Effect of Ducted HPWH on Space Conditioning and Water Heating Energy Use - Central Florida Lab Home, Cocoa, Florida

The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Effect of Ducted HPWH on Space Conditioning and Water Heating Energy Use - Central Florida Lab Home, Cocoa, Florida

The purpose of this research is to investigate the impact of ducted heat pump water heaters (HPWH's) on space conditioning and water heating energy use in residential applications. Two identical HPWH's, each of 60 gallon capacity were tested side by side at the Flexible Residential Test facility (FRTF) laboratories of the Florida Solar Energy Center (FSEC) campus in Cocoa, Florida. The water heating experiments were run in each test house from July 2014 until February 2015.

BA-PIRC↗

Performance and Implementation of Hydrophobic Filter Material for Nuclear Material Transportation and Storage Containers - 18550

Los Alamos National Laboratory has developed a hydrophobic filter material that resists water ingress after exposure to radiation and/or elevated temperature. Facility and transportation accident scenarios often include fire, impact and subsequent water spray or flooding conditions. The hydrophobic filter material provides enhanced resistance to fire and radiation damage, and continues to minimize water ingress after such an accident. Test results indicate that the treated filters provide resistance to a water column pressure test and have filtration efficiencies and air flow pressure drops that meet the current performance criteria for the SAVY{sup TM}-4000. These filters could broaden the use of filtered containers in the transportation and storage of nuclear materials, and could have broader implications in other industrial applications. Implementation of the new hydrophobic filter material is planned for the SAVY{sup TM}-4000 nuclear storage container, which will lead the way for this robust material to be applied to other nuclear material transportation and storage containers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems. Part 1, Bulk Phase: Bulk Phase - Part 1

The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the mid 1980s, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in open, semi-closed and closed loop life support system. The biofilm and biodeterioration studies that were performed during the design and test periods will be presented in a future publication.

Roman, Monsi C.↗

Overview of Microbiological Tests Performed During the Design of the International Space Station Environmental Control and Life Support Systems

The design and manufacturing of the main Environmental Control and Life Support Systems (ECLSS) for the United States segments of the International Space Station (ISS) was an involved process that started in the late 1980's, with the assessment and testing of competing technologies that could be used to clean the air and recycle water. It culminated in 2009 with the delivery and successful activation of the Water Recovery System (WRS) water processor (WP). The ECLSS required the work of a team of engineers and scientist working together to develop systems that could clean and/or recycle human metabolic loads to maintain a clean atmosphere and provide the crew clean water. One of the main goals of the ECLSS is to minimize the time spent by the crew worrying about vital resources not available in the vacuum of space, which allows them to spend most of their time learning to live in a microgravity environment many miles from the comforts of Earth and working on science experiments. Microorganisms are a significant part of the human body as well as part of the environment that we live in. Therefore, the ISS ECLSS design had to take into account the effect microorganisms have on the quality of stored water and wastewater, as well as that of the air systems. Hardware performance issues impacted by the accumulation of biofilm and/or microbiologically influenced corrosion were also studied during the ECLSS development stages. Many of the tests that were performed had to take into account the unique aspects of a microgravity environment as well as the challenge of understanding how to design systems that could not be sterilized or maintained in a sterile state. This paper will summarize the work of several studies that were performed to assess the impacts and/or to minimize the effects of microorganisms in the design of a closed loop life support system.

Roman, Monsi C.↗

USU Camas-1 Test Well: Documentation

This submission contains documents that describe the USU Camas-1 test well, drilled in Camas Prairie, Idaho, in Fall 2018 and Fall 2019. The purpose of this well is to validate exploration methodologies of the Snake River Plain (SRP) Play Fairway Analysis (PFA) project.

15 GEOTHERMAL ENERGY↗

Observing and Projecting the Lasting Fate of the Hunga Eruption on Atmospheric Water Vapor and Hydroxyl Radical

On 15th Jan. 2022 the submarine Hunga volcano erupted injecting approximately 0.5 Tg of sulfur dioxide into the stratosphere, but more significantly added 150-170 Tg of water vapor to the stratospheric background (over a 10% perturbation) in a matter of several hours. The sulfur dioxide rapidly converted to sulfate aerosol and along with water vapor, was transported around the Southern Hemisphere sub-tropics into midlatitudes and beyond with some transport into the Northern Hemisphere. With a much longer lifetime than sulfate aerosol, measurable water vapor mass anomalies have persisted with only small losses over more than 2 years since the eruption and are likely to continue above background for the remainder of the decade. Satellite measurements from limb and nadir viewing observing instruments provide the information needed to reasonably initialize the Hunga eruption in the Goddard Earth Observing System (GEOS) model using the “replay” framework coupled to the Global Modeling Initiative (GMI) stratosphere-troposphere chemical mechanism for the recent past and have continued the simulations into the future with the free running chemistry climate model (CCM). Using a number of model ensemble members together with the satellite observations, we quantify how the Hunga eruption is perturbing atmospheric composition and climate and projecting the influences to come as the enhanced water vapor continues in the stratosphere with only very slow removal mechanisms. Modeling suggests that the water rich eruption enhanced stratospheric hydroxyl radiacal (OH) and is supported by the speed of the observed conversion of SO2 into sulfate aerosol. These simulations also suggest a significant reduction in tropospheric OH over the mid-high latitude Southern Hemisphere, which has implications for numerous species that are impacted by this radical. The Hunga eruption provides a useful test of chemistry climate models and an opportunity for observation-based process understanding and in making new connections.

Hunga volcano↗

Bayesian performance evaluation of evapotranspiration models based on eddy covariance systems in an arid region

Abstract. Evapotranspiration (ET) is a major component of the land surface processinvolved in energy fluxes and energy balance, especially in the hydrologicalcycle of agricultural ecosystems. While many models have been developed aspowerful tools to simulate ET, there is no agreement on which model bestdescribes the loss of water to the atmosphere. This study focuses on twoaspects, evaluating the performance of four widely used ET models andidentifying parameters, and the physical mechanisms that havesignificant impacts on the model performance. The four tested models arethe Shuttleworth–Wallace (SW) model, Penman–Monteith (PM) model,Priestley–Taylor and Flint–Childs (PT–FC) model, and advection–aridity (AA)model. By incorporating the mathematically rigorous thermodynamicintegration algorithm, the Bayesian model evidence (BME) approach is adoptedto select the optimal model with half-hourly ET observations obtained at aspring maize field in an arid region. Our results reveal that the SW model has thebest performance, and the extinction coefficient is not merely partitioningthe total available energy into the canopy and surface but also includingthe energy imbalance correction. The extinction coefficient is wellconstrained in the SW model and poorly constrained in the PM model but notconsidered in PT–FC and AA models. This is one of the main reasons that theSW model outperforms the other models. Meanwhile, the good fitting of SWmodel to observations can counterbalance its higher complexity. In addition,the detailed analysis of the discrepancies between observations and modelsimulations during the crop growth season indicate that explicit treatmentof energy imbalance and energy interaction will be the primary way offurther improving ET model performance.

54 ENVIRONMENTAL SCIENCES↗

Crash Simulation of a Vertical Drop Test of a Commuter-Class Aircraft

A finite element model of an ATR42-300 commuter-class aircraft was developed and a crash simulation was executed. Analytical predictions were correlated with data obtained from a 30-ft/s (9.14-m/s) vertical drop test of the aircraft. The purpose of the test was to evaluate the structural response of the aircraft when subjected to a severe, but survivable, impact. The aircraft was configured with seats, dummies, luggage, and other ballast. The wings were filled with 8,700 lb. (3,946 kg) of water to represent the fuel. The finite element model, which consisted of 57,643 nodes and 62,979 elements, was developed from direct measurements of the airframe geometry. The seats, dummies, luggage, fuel, and other ballast were represented using concentrated masses. The model was executed in LS-DYNA, a commercial code for performing explicit transient dynamic simulations. Predictions of structural deformation and selected time-history responses were generated. The simulation was successfully validated through extensive test-analysis correlation.

Jackson, Karen E.↗

A field study of solid rocket exhaust impacts on the near-field environment

Large solid rocket motors release large quantities of hydrogen chloride and aluminum oxide exhaust during launch and testing. Measurements and analysis of the interaction of this material with the deluge water spray and other environmental factors in the near field (within 1 km of the launch or test site) are summarized. Measurements of mixed solid and liquid deposition (typically 2 normal HCl) following space shuttle launches and 6.4 percent scale model tests are described. Hydrogen chloride gas concentrations measured in the hours after the launch of STS 41D and STS 51A are reported. Concentrations of 9 ppm, which are above the 5 ppm exposure limits for workers, were detected an hour after STS 51A. A simplified model which explains the primary features of the gas concentration profiles is included.

Anderson, B. J.↗

ENERGY STAR Residential Water Heater Specification and Test Method for Connected Residential Water Heaters

Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.

connected water heater↗