Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voltage Magnitude”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Impedance-Aware Graph Convolutional Networks for Voltage Estimation in Active Distribution Networks

Voltage estimation plays a key role in ensuring the effective control and reliability of distribution networks. However, traditional machine learning methods often fail to capture the details of the distribution network’s topology. To overcome this challenge, graph convolutional networks (GCN) have emerged as an alternative. Graph convolutional networks inherently capture the topology of the grid, utilizing correlations to achieve precise voltage estimation. Other machine learning models and conventional GCNs fail to account for the distribution line characteristics found in the real world, limiting their effectiveness. This paper proposes an advanced variant of GCN called the Impedance-Aware Graph Convolutional Network (IA-GCN). The IA-GCN layer incorporates the magnitude of the impedance into the graph convolution mechanism, allowing it to capture topological nuances and provide valuable insights into node interrelationships by considering impedance as an intrinsic dimension. The performance of the IA-GCN layer is then compared with that of GCN and GraphSAGE layers through a surrogate model for voltage estimation. The performance analysis demonstrates that IA-GCN outperforms GCN by reducing the MAE by 87.55% and improving the R-squared value by 98%.

Ravi, Abhijith↗

Assembly of Close–Packed Ferroelectric Polymer Nanowires via Interface–Epitaxy with ReS 2

The flexible, transparent, and low-weight nature of ferroelectric polymers makes them promising for wearable electronic and optical applications. To reach the full potential of the polarization-enabled device functionalities, large-scale fabrication of polymer thin films with well-controlled polar directions is called for, which remains a central challenge. The widely exploited Langmuir–Blodgett, spin-coating, and electrospinning methods only yield polymorphous or polycrystalline films, where the net polarization is compromised. Here, an easily scalable approach is reported to achieve poly(vinylidene fluoride-trifluoroethylene) P(VDF-TrFE) thin films composed of close-packed crystalline nanowires via interface-epitaxy with 1T'-ReS 2 . Upon controlled thermal treatment, uniform P(VDF-TrFE) films restructure into about 10 and 35 nm-wide (010)-oriented nanowires that are crystallographically aligned with the underlying ReS 2 , as revealed by high-resolution transmission electron microscopy. Piezoresponse force microscopy studies confirm the out-of-plane polar axis of the nanowire films and reveal coercive voltages as low as 0.1 V. Reversing the polarization can induce a conductance switching ratio of >10 8 in bilayer ReS 2 , over six orders of magnitude higher than that achieved by an untreated polymer gate. Lastly, this study points to a cost-effective route to large-scale processing of high-performance ferroelectric polymer thin films for flexible energy-efficient nanoelectronics.

crystalline nanowires↗

Impact of Different Thermal Gradients on the Dynamics of Cylindrical Lithium-ion Cells Subject to Accelerated Aging and on Module Performance

This study investigates the impacts of applying different thermal gradient patterns to cylindrical lithium-ion cells in a module on cell dynamics (temperatures, current flows, state of charge), module performance (evolution of resistance, capacity, and energy versus cycle number), and module lifetime. The thermal gradients were generated using cooling plates (CPs) with three different flow-field designs, namely, straight, perpendicular, and U-turn. The study uses computational fluid dynamics (CFD), the pseudo-two-dimensional (P2D) battery model, capacity loss and increased impedance due to the growth of a solid-electrolyte-interphase, and the electric current distribution from module terminals to cells that depends on the series-parallel electrical connections among the cells. The impact of the thermal gradient (resulting from the CP designs) on the variability in resistance, current, state of charge, and voltage among the cells was analyzed and linked to differences in the module's performance. Applying a thermal gradient to parallel-connected strings of series-connected cells led to variation in the current through each parallel string and an imbalance in the voltage of series-connected cells. Module performance is poorer when the thermal gradient causes a voltage imbalance than when it causes a current imbalance. Module performance becomes the worst when both current variation and voltage imbalance happen together. For instance, the module's lifetime (estimated as reaching 80% of its initial capacity) varied by 5% to 17.5%, depending on the magnitude and pattern of the imposed thermal gradient. As the relative orientation between thermal gradients and cells' electrical connectivity influences the module's performance, appropriate consideration should be given to the choice of the CP, especially if large thermal gradients are allowed.

Battery thermal management↗

Temperature dependence of resistivity of carbon micro/nanostructures: Microscale spatial distribution with mixed metallic and semiconductive behaviors

The temperature coefficient of resistivity (θ T ) of carbon-based materials is a critical property that directly determines their electrical response upon thermal impulses. It could have metal- (positive) or semiconductor-like (negative) behavior, depending on the combined temperature dependence of electron density and electron scattering. Its distribution in space is very difficult to measure and is rarely studied. Here, for the first time, we report that carbon-based micro/nanoscale structures have a strong non-uniform spatial distribution of θ T . This distribution is probed by measuring the transient electro-thermal response of the material under extremely localized step laser heating and scanning, which magnifies the local θ T effect in the measured transient voltage evolution. For carbon microfibers (CMFs), after electrical current annealing, θ T varies from negative to positive from the sample end to the center with a magnitude change of >130% over <1 mm. This θ T sign change is confirmed by directly testing smaller segments from different regions of an annealed CMF. For micro-thick carbon nanotube bundles, θ T is found to have a relative change of >125% within a length of ~2 mm, uncovering strong metallic to semiconductive behavior change in space. In conclusion, our θ T scanning technique can be readily extended to nm-thick samples with μm scanning resolution to explore the distribution of θ T and provide a deep insight into the local electron conduction.

36 MATERIALS SCIENCE↗

A Robust Communication-Free Protection Scheme for Islanded Microgrids with Relay Logic and Hardware-in-the-Loop Validation

This paper presents the Imbalance Square Factor (ISF) detection algorithm, an effective, computationally lightweight method for detecting faults in inverter-based microgrids. ISF provides a high magnitude at the time of the fault, which allows for fast detection and coordination between primary and backup relays. The imbalance squared factor, calculated using local voltage and currents, is used for fault detection and coordination among three relays. ISF is validated in hardware-in-the-loop (HIL) implementation inside commercial-grade relay logic (SEL-751). The HIL validation shows that ISF can coordinate primary, secondary, and tertiary relays in the 13-bus system in islanded operation.

Ferrari Maglia, Max [ORNL]↗

Reprogrammable electro-chemo-optical devices and methods for using the same

Reconfigurable, active optical components can flexibly manipulate light. One example of these components is an electro-chemo-optical device that utilizes a metal oxide film with a complex refractive index that varies as a function of an oxygen vacancy concentration. The optical device may include a metal oxide film, a first electrode, and a second electrode. The first electrode and the second electrode may be used to supply a bias voltage to induce a change in the oxygen vacancy concentration in order to change the optical properties (absorbance, transmittance, and/or reflectance) of the optical device. The magnitude and spatial distribution of the oxygen vacancy concentration may be altered to affect the optical properties of the optical device. In some designs, the optical device may also include an ionic conductor and oxygen source to supply/receive oxygen ions to/from the metal oxide film.

Kalaev, Dmitri↗

A First Look at Carbon and Oxygen Stable Isotope Measurements of Martian Atmospheric C02 by the Phoenix Lander

Precise stable isotope measurements of the CO2 in the martian atmosphere have the potential to provide important constraints for our understanding of the history of volatiles, the carbon cycle, current atmospheric processes, and the degree of water/rock interaction on Mars. The isotopic composition of the martian atmosphere has been measured using a number of different methods (Table 1), however a precise value (<1%) has yet to be achieved. Given the elevated 13C values measured in carbonates in martian meteorites it has been supposed that the martian atmosphere was enriched in delta(sup 13)C. This was supported by measurements of trapped CO2 gas in EETA 79001[2] which showed elevated delta(sup 13)C values (Table 1). More recently, Earth-based spectroscopic measurements of the martian atmosphere have measured the martian CO2 to be depleted in delta(sup 13)C relative to CO2 in the terrestrial atmosphere. The spectroscopic measurements performed by Krasnopolsky et al. were reported with approx.2% uncertainties which are much smaller than the Viking measurements, but still remain very large in comparison to the magnitude of carbon and oxygen isotope fractionations under martian surface conditions. The Thermal Evolved Gas Analyzer (TEGA) instrument on the Mars Phoenix Lander included a magnetic sector mass spectrometer (EGA) which had the goal of measuring the isotopic composition of martian atmospheric CO2 to within 0.5%. The mass spectrometer is a miniature magnetic sector instrument intended to measure both the martian atmosphere as well as gases evolved from heating martian soils. Ions produced in the ion source are drawn out by a high voltage and focused by a magnetic field onto a set of collector slits. Four specific trajectories are selected to cover the mass ranges, 0.7 - 4, 7 - 35, 14 - 70, and 28 - 140 Da. Using four channels reduces the magnitude of the mass scan and provides simultaneous coverage of the mass ranges. Channel electron multiplier (CEM) detectors that operate in the pulse counting mode detect the ion beams.

Niles, P.B.↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Local p‐ and n‐Type Doping of an Oxide Semiconductor via Electric‐Field‐Driven Defect Migration

Layered oxides exhibit high ionic mobility and chemical flexibility, attracting interest as cathode materials for lithium-ion batteries and the pairing of hydrogen production and carbon capture. Recently, layered oxides emerged as highly tunable semiconductors. For example, by introducing anti-Frenkel defects, the electronic hopping conductance in hexagonal manganites is increased locally by orders of magnitude. Here, local acceptor and donor doping in Er(Mn,Ti)O3 is demonstrated, facilitated by the controlled splitting of anti-Frenkel defects under applied d.c. voltage. By combining density functional theory calculations, scanning probe microscopy, atom probe tomography, and scanning transmission electron microscopy, it is shown that the oxygen defects can readily be moved through the layered crystal structure, leading to nano-sized interstitial-rich (p-type) and vacancy-rich (n-type) regions. The resulting pattern is comparable to dipolar npn-junctions and stable on the timescale of days. These findings reveal the possibility of temporarily functionalizing oxide semiconductors at the nanoscale, giving additional opportunities for the field of oxide electronics and the development of transient electronics in general.

He, Jiali↗

Mitigating Heavy Ion Irradiation‐Induced Degradation in p‐type SnO Thin‐Film Transistors at Room Temperature

The study investigates the mitigation of radiation damage on p‐type SnO thin‐film transistors (TFTs) with a fast, room‐temperature annealing process. Atomic layer deposition is utilized to fabricate bottom‐gate TFTs of high‐quality p‐type SnO layers. After 2.8 MeV Au 4+ irradiation at a fluence level of 5.2 × 10 12 ions cm −2 , the output drain current and on/off current ratio ( I on / I off ) decrease by more than one order of magnitude, field‐effect mobility ( μ FE ) reduces more than four times, and subthreshold swing (SS) increases more than four times along with a negative shift in threshold voltage. The observed degradation is attributed to increased surface roughness and defect density, as confirmed by scanning electron microscopy (SEM), high‐resolution micro‐Raman, and transmission electron microscopy (TEM) with geometric phase analysis (GPA). A technique is demonstrated to recover the device performance at room temperature and in less than a minute, using the electron wind force (EWF) obtained from low‐duty‐cycle high‐density pulsed current. At a pulsed current density of 4.0 × 10 5 A cm −2 , approximately four times increase in I on / I off is observed, 41% increase in μ FE , and 20% decrease in the SS of the irradiated TFTs, suggesting effectiveness of the new annealing technique.

Al-Mamun, Nahid Sultan↗

Low-temperature spin Seebeck effect in nonmagnetic vanadium dioxide

The spin Seebeck effect (SSE) is sensitive to thermally driven magnetic excitations in magnetic insulators. Vanadium dioxide in its insulating low-temperature phase is expected to lack magnetic degrees of freedom, as vanadium atoms are thought to form singlets upon dimerization of the vanadium chains. Instead, we find a paramagnetic SSE response in V⁢O 2 films that grows as the temperature decreases below 50 K. The field and temperature-dependent SSE voltage is qualitatively consistent with a general model of paramagnetic SSE response and inconsistent with triplet spin transport. Quantitative estimates find a spin Seebeck coefficient comparable in magnitude to that observed in strongly magnetic materials. Finally, the microscopic nature of the magnetic excitations in V⁢O 2 requires further examination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic characteristics of a 30-centimeter mercury ion thruster

The present work reports on measurements of the fluctuations in the beam current, discharge current, neutralizer keeper current, and discharge voltage of a 30-cm ion thruster made with 60Hz laboratory-type power supplies. The intensities of the fluctuations (ratio of the root-mean-square magnitude to time-average quantity) were found to depend significantly on the beam and magnetic baffle currents. The shape of the frequency spectra of the discharge plasma fluctuations was related to the beam and magnetic baffle currents. The predominant peaks of the beam and discharge current spectra occurred at frequencies less than 30 kilohertz. This discharge chamber resonance could be attributable to ion-acoustic wave phenomena. Cross-correlations of the discharge and beam currents indicated that the dependence on the magnetic baffle current was strong. The measurements revealed that the discharge current fluctuations directly contribute to the beam current fluctuations and that the power supply characteristics can modify these fluctuations.

Serafini, J. S.↗

Toroidal-Core Microinductors Biased by Permanent Magnets

The designs of microscopic toroidal-core inductors in integrated circuits of DC-to-DC voltage converters would be modified, according to a proposal, by filling the gaps in the cores with permanent magnets that would apply bias fluxes (see figure). The magnitudes and polarities of the bias fluxes would be tailored to counteract the DC fluxes generated by the DC components of the currents in the inductor windings, such that it would be possible to either reduce the sizes of the cores or increase the AC components of the currents in the cores without incurring adverse effects. Reducing the sizes of the cores could save significant amounts of space on integrated circuits because relative to other integrated-circuit components, microinductors occupy large areas - of the order of a square millimeter each. An important consideration in the design of such an inductor is preventing magnetic saturation of the core at current levels up to the maximum anticipated operating current. The requirement to prevent saturation, as well as other requirements and constraints upon the design of the core are expressed by several equations based on the traditional magnetic-circuit approximation. The equations involve the core and gap dimensions and the magnetic-property parameters of the core and magnet materials. The equations show that, other things remaining equal, as the maximum current is increased, one must increase the size of the core to prevent the flux density from rising to the saturation level. By using a permanent bias flux to oppose the flux generated by the DC component of the current, one would reduce the net DC component of flux in the core, making it possible to reduce the core size needed to prevent the total flux density (sum of DC and AC components) from rising to the saturation level. Alternatively, one could take advantage of the reduction of the net DC component of flux by increasing the allowable AC component of flux and the corresponding AC component of current. In either case, permanent-magnet material and the slant (if any) and thickness of the gap must be chosen according to the equations to obtain the required bias flux. In modifying the design of the inductor, one must ensure that the inductance is not altered. The simplest way to preserve the original value of inductance would be to leave the gap dimensions unchanged and fill the gap with a permanent- magnet material that, fortuitously, would produce just the required bias flux. A more generally applicable alternative would be to partly fill either the original gap or a slightly enlarged gap with a suitable permanent-magnet material (thereby leaving a small residual gap) so that the reluctance of the resulting magnetic circuit would yield the desired inductance.

Lieneweg, Udo↗

PASP: A high voltage array experiment

In the near future, Air Force mission payloads will require significant increases in power. Sophisticated sensing systems such as infrared focal plane detector arrays and radar will be employed by the Air Force to fulfill its strategic objectives. These payloads will demand that the power subsystem provide up to 50 kW at the end of mission life, more than an order of magnitude greater than is currently required. Some of these payloads must be flown in low-Earth polar orbits to satisfy mission objectives, and it is likely that large (500 to 600 sq m) solar photovoltaic arrays will operate in the low-Earth polar environment. The standard 28 volt power subsystem is not weight efficient for the array power levels being considered. The impact of the solar array operating voltage on the total weight of the array and the subsystem power conditioning and distribution components is illustrated. In the interest of reducing power subsystem weight, higher array operating voltages are considered. The problems which the higher array voltage present to the array designer are discussed. In order to provide a maximum return on the tremendous investment of resources required to develop and place these assets in orbit, they must be designed to operate effectively for extended periods of time. To achieve this, the system must be able to function in the threat-induced and natural space environment.

Scott-Monck, J.↗

Voltage cycling process for the electroconversion of biomass-derived polyols

Electrification of chemical reactions is crucial to fundamentally transform our society that is still heavily dependent on fossil resources and unsustainable practices. In addition, electrochemistry-based approaches offer a unique way of catalyzing reactions by the fast and continuous alteration of applied potentials, unlike traditional thermal processes. In this work, we show how the continuous cyclic application of electrode potential allows Pt nanoparticles to electrooxidize biomass-derived polyols with turnover frequency improved by orders of magnitude compared with the usual rates at fixed potential conditions. Moreover, secondary alcohol oxidation is enhanced, with a ketoses-to-aldoses ratio increased up to sixfold. The idea has been translated into the construction of a symmetric single-compartment system in a two-electrode configuration. Its operation via voltage cycling demonstrates high-rate sorbitol electrolysis with the formation of H 2 as a desired coproduct at operating voltages below 1.4 V. The devised method presents a potential approach to using renewable electricity to drive chemical processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Spin Polarization and Rectification Driven by Chiral Perylene Diimide-Based Nanodonuts

The chirality-induced spin selectivity (CISS) effect allows thin-film layers of chiral conjugated molecules to function as spin filters at ambient temperature. Through solvent-modulated dropcasting of chiral l- and d-perylene diimide (PDI) monomeric building blocks, two types of aggregate morphologies, nanofibers and nanodonuts, may be realized. Spin-diode behavior is evidenced in the nanodonut structures. Stacked PDI units, which form the conjugated core of these nanostructures, dominate the nanodonut–Au electrode contact; in contrast, the AFM tip contacts largely the high-resistance solubilizing alkyl chains of the chiral monomers that form these nanodonuts. Current–voltage responses of the nanodonuts, measured by magnetic conductive AFM (mC-AFM), demonstrate substantial spin polarizations as well as spin current rectification ratios (>10) that exceed the magnitudes of those determined to date for other chiral nanoscale systems. Furthermore, these results underscore the potential for chiral nanostructures, featuring asymmetric molecular junctions, to enable CISS-based nanoscale spin current rectifiers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Universal Relationship between Limiting Current and Electrochemical Transport Properties in Malonate-Based Polymer Electrolytes

There is considerable interest in developing high-performance electrolytes for rechargeable lithium batteries. For practical applications, the electrolyte must support large dc currents. However, the parameters most often reported in the literature, conductivity, κ, and current fraction, ρ + , reflect ion transport in the limit of infinitesimal currents. In this limit, the efficacy of an electrolyte is given by the product κρ + . The limiting current density, i lim , is the maximum current density that can be applied across an electrolyte; the cell voltage diverges if the applied current density exceeds ilim. This parameter reflects ion transport in the limit of large dc currents and is therefore of practical interest. It would therefore be convenient if i lim could be predicted from measurements of κρ + . In order to explore this possibility, we studied six malonate-based polymers and PEO at a fixed salt concentration (r = 0.08) and temperature (90°C) using symmetric cells with planar electrodes. Unfortunately, there is no correlation between ilim and κρ + . When the applied current density, i, is less than ilim, the cell voltage approaches a stable plateau, ϕ plateau . Here, we found a linear dependence between i and thickness-normalized plateau potential, ϕ plateau L –1 , irrespective of the magnitude of the applied current. In all seven polymer electrolytes, we found a linear correlation between ilim and the slopes of these lines, σ. In other words, measurements of σ can be used to predict the limiting current.

Jana, Rounak [Lawrence Berkeley National Laborator↗