Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ventilation Relevant Contaminants of Concern in Commercial Buildings Screening Process and Results

This report summarizes the screening procedure and its results for selecting contaminants of concern (COC), whose concentrations are affected by ventilation in commercial buildings. Many pollutants comprising criteria pollutants, volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs) and biological contaminants are found in commercial buildings. In this report, we focus primarily on identifying potential volatile organic COC, which are impacted by ventilation. In the future we plan to extend this effort to inorganic gases and particles. Our screening considers compounds detected frequently in indoor air and compares the concentrations to health-guidelines and thresholds. However, given the range of buildings under consideration, the contaminant sources and their concentrations will vary depending on the activity and use of the buildings. We used a literature review to identify a large list of chemicals found in commercial-building indoor air. The VOCs selected were subject to a two stage screening process, and the compounds of greater interest are included in priority List A. Other VOCs that have been detected in commercial buildings are included in priority List B. The compounds in List B, were further classified into groups B1, B2, B3, B4 in order of decreasing interest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores

The HZEB research program aims to generate information needed to develop new science-based commercial building ventilation rate (VR) standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. This interim report describes the preliminary results from one HZEB field study on retail stores. The primary purpose of this study is to estimate the whole-building source strengths of contaminant of concerns (COCs). This information is needed to determine the VRs necessary to maintain indoor concentrations of COCs below applicable health guidelines.The goal of this study is to identify contaminants in retail stores that should be controlled via ventilation, and to determine the minimum VRs that would satisfy the occupant health and odor criteria.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Ventilation Systems for Existing Homes

In an effort to improve housing options near Las Vegas, Nevada, the Clark County Community Resources Division (CCCRD) performs substantial renovations to foreclosed homes. After dramatic energy, aesthetic, and health and safety improvements are made, homes are rented or sold to qualified residents. This report describes the evaluation and selection of ventilation systems for these homes, including key considerations when selecting an ideal system. The report then describes CCCRD’s decision process with respect to ventilation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and IAQ Implications of Alternative Minimum Ventilation Rates in California Retail and School Buildings

For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Tank 22 Demister Solids Responsible for Preventing Adequate Purge Ventilation Flow (U)

In December 2020, about 2.5 grams of the solid material from the Tank 22 purge ventilation demister, responsible for preventing adequate purge ventilation flow, were delivered to Savannah River National Laboratory (SRNL) by Savannah River Remediation (SRR) for analysis to identify the chemical nature of the solids and possibly address why fresh water and caustic flushes with 50 wt. % sodium hydroxide solution are essentially ineffective in dissolving or dislodging the accumulated solids from the Tank 22 demister at low ambient temperature conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology assessment to reduce aerosol transmission risk in naturally ventilated K12 classrooms (CRADA Final Report)

LBNL provided technical assistance to Oakland Unified School District (OUSD) through this project in their selection of technologies to support in-person instruction. OUSD considered different technologies to mitigate the aerosol transmission risks of COVID-19: a) Upgrade to higher efficiency air filters in buildings that are served by heating, ventilation, and air conditioning (HVAC) systems. b) Install portable air cleaners with HEPA (high efficiency particulate air) filters. c) Install ultraviolet germicidal irradiation (UVGI) systems. d) Install bipolar ionization air cleaning systems. LBNL met with OUSD facilities staff to discuss the pros and cons of options a) and c), and cited the lack of proven data on efficacy and discouraged option d). LBNL provided practical guidance on how to select portable air cleaners for classrooms. LBNL met with the boarder school communities to explain OUSD approach to ventilation and filtration, and produced FAQs to answer their questions about the science behind the selected approaches. In addition, LBNL helped OUSD facilities staff to acquire five indoor air quality (IAQ) monitors (AirVisual Pro by IQAir) for measuring carbon dioxide (CO2) and particulate matter (PM) concentrations. These monitors were installed in an elementary school in West Oakland.

60 APPLIED LIFE SCIENCES↗

Aerosol and Gas Transport in Ventilation Ducts in Nonreactor Nuclear Facilities

This document summarizes outcomes and finding in FY 2022 from a project sponsored by the Nuclear Safety Research and Development Program, which is managed by the Office of Nuclear Safety, within the Office of Environment, Health, Safety and Security. Literature survey and data collection are discussed in Sections 1 and 2, respectively. Numerical modeling of particulate transports in ventilation systems performed for standard geometries and a full-scale ventilation system is described in Section 3, and Section 4 summarizes the development of proof-of-concept sensors featuring ultrasound technology for particle deposition removal. Conclusions and recommendations are outlined in Section 5.

42 ENGINEERING↗

Failure mode analysis of the FFTF heating and ventilation system 25

This document was prepared as a supplemental study to Chapter 9.4 of the FFTF Final Safety Analysis Report and is included as a Category A reference in FFTF System Design Description 25, Heating and Ventilation System. It contains the single failure mode analysis on all the heating and ventilation systems that are essential to the safety of the plant, and confirms the adequacy of the system design to accommodate single failures without jeopardizing overall plant safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prognostic analysis of high-flow nasal cannula therapy and non-invasive ventilation in mild to moderate hypoxemia patients and construction of a machine learning model for 48-h intubation prediction—a retrospective analysis of the MIMIC database

Background This study aims to investigate the clinical outcome between high-flow nasal cannula (HFNC) and non-invasive ventilation (NIV) therapy in mild to moderate hypoxemic patients on the first ICU day and to develop a predictive model of 48-h intubation. Methods The study included adult patients from the MIMIC III and IV databases who first initiated HFNC or NIV therapy due to mild to moderate hypoxemia (100 < PaO2/FiO2 ≤ 300). The 48-h and 30-day intubation rates were compared using cross-sectional and survival analysis. Nine machine learning and six ensemble algorithms were deployed to construct the 48-h intubation predictive models, of which the optimal model was determined by its prediction accuracy. The top 10 risk and protective factors were identified using the Shapley interpretation algorithm. Result A total of 123,042 patients were screened, of which, 673 were from the MIMIC IV database for ventilation therapy comparison (HFNC n = 363, NIV n = 310) and 48-h intubation predictive model construction (training dataset n = 471, internal validation set n = 202) and 408 were from the MIMIC III database for external validation. The NIV group had a lower intubation rate (23.1% vs. 16.1%, p = 0.001), ICU 28-day mortality (18.5% vs. 11.6%, p = 0.014), and in-hospital mortality (19.6% vs. 11.9%, p = 0.007) compared to the HFNC group. Survival analysis showed that the total and 48-h intubation rates were not significantly different. The ensemble AdaBoost decision tree model (internal and external validation set AUROC 0.878, 0.726) had the best predictive accuracy performance. The model Shapley algorithm showed Sequential Organ Failure Assessment (SOFA), acute physiology scores (APSIII), the minimum and maximum lactate value as risk factors for early failure and age, the maximum PaCO 2 and PH value, Glasgow Coma Scale (GCS), the minimum PaO 2 /FiO 2 ratio, and PaO 2 value as protective factors. Conclusion NIV was associated with lower intubation rate and ICU 28-day and in-hospital mortality. Further survival analysis reinforced that the effect of NIV on the intubation rate might partly be attributed to the other impact factors. The ensemble AdaBoost decision tree model may assist clinicians in making clinical decisions, and early organ function support to improve patients’ SOFA, APSIII, GCS, PaCO 2 , PaO 2 , PH, PaO 2 /FiO 2 ratio, and lactate values can reduce the early failure rate and improve patient prognosis.

Fu, Wei↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗

Reduction of noise generated by air conditioning and ventilation plants and transmitted to inhabited areas

The fans with which the conditioning and ventilation plants of weaving and spinning mills are equipped and the conditioning devices used in certain confection and knit wear departments of the textile industry generate loud noise. Solutions are presented for reducing the noise generated by the fans of ventilation and conditioning plants and transmitted to inhabited regions down to the admissible level, as well as the results obtained by experimental application of some noise reduction solutions in the conditioning plants of a spinning mill.

Harastaseanu, E.↗

Unsteady two dimensional airloads acting on oscillating thin airfoils in subsonic ventilated wind tunnels

The numerical calculation of unsteady two dimensional airloads which act upon thin airfoils in subsonic ventilated wind tunnels was studied. Neglecting certain quadrature errors, Bland's collocation method is rigorously proved to converge to the mathematically exact solution of Bland's integral equation, and a three way equivalence was established between collocation, Galerkin's method and least squares whenever the collocation points are chosen to be the nodes of the quadrature rule used for Galerkin's method. A computer program displayed convergence with respect to the number of pressure basis functions employed, and agreement with known special cases was demonstrated. Results are obtained for the combined effects of wind tunnel wall ventilation and wind tunnel depth to airfoil chord ratio, and for acoustic resonance between the airfoil and wind tunnel walls. A boundary condition is proposed for permeable walls through which mass flow rate is proportional to pressure jump.

Fromme, J.↗

Fuselage ventilation under wind conditions

To determine realistic fuselage ventilation rates for post-crash fires and full-scale fire tests, the effects on wind-about fuselage ventilation rate of various parameters were studied. The parameters investigated were fuselage size and shape, fuselage orientation and proximity to ground, fuselage-opening and location, and wind speed and direction.

Stuart, J. W.↗

Two dimensional aerodynamic interference effects on oscillating airfoils with flaps in ventilated subsonic wind tunnels

The numerical computation of unsteady airloads acting upon thin airfoils with multiple leading and trailing-edge controls in two-dimensional ventilated subsonic wind tunnels is studied. The foundation of the computational method is strengthened with a new and more powerful mathematical existence and convergence theory for solving Cauchy singular integral equations of the first kind, and the method of convergence acceleration by extrapolation to the limit is introduced to analyze airfoils with flaps. New results are presented for steady and unsteady flow, including the effect of acoustic resonance between ventilated wind-tunnel walls and airfoils with oscillating flaps. The computer program TWODI is available for general use and a complete set of instructions is provided.

Fromme, J.↗

Parametric instabilities of rotor-support systems with application to industrial ventilators

Rotor support systems interaction with parametric excitation is considered for both unequal principal shaft stiffness (generators) and offset disc rotors (ventilators). Instability regions and types of instability are computed in the first case, and parametric resonances in the second case. Computed and experimental results are compared for laboratory machine models. A field case study of parametric vibrations in industrial ventilators is reported. Computed parametric resonances are confirmed in field measurements, and some industrial failures are explained. Also the dynamic influence and gyroscopic effect of supporting structures are shown and computed.

Parszewski, Z.↗

Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

Source record↗

Ventilation flow: Submerged

The ventilation system on a submarine is discussed. When the submarine is submerged. The ventilation system provides a conditioned atmosphere in the ship with complete isolation from the outside. A conditioned atmosphere includes not only filtration and temperature and humidity control, but also air purification (removal of potentially harmful quantities of impurities and comtaminants) and revitalization (addition of vital life support oxygen). Carbon dioxide removal, the oxygen system, air conditioning, carbon monoxide removal, hydrogen removal, and atmosphere monitoring systems are among the topics discussed.

Hutchinson, D.↗

Pool fire-ventilation crossflow experiments in a simulated aircraft cabin interior

An experimental facility has been built to study pool fire dynamics and flame spread behavior in a 1/3-scale simulated aircraft interior; attention is presently given to pool fire ventilation crossflow using a 'channel' pool fire subjected to crossflow velocities that replicate postcrash conditions in a wide body aircraft. Crossflow velocity is noted to have a strong effect on visible flame geometry, tilting the flame over sharply. A reverse flow ceiling jet of hot gases was also present in all tests, however, and extended far upstream of the fire, so that despite the appearance of the visible flame, the vertical momentum of the plume was strong enough to establish the reverse flow layer and spread smoke and toxic gases upstream against a significant ventilating flow.

Bankston, C. P.↗