Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Vacuum stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

NASA PS400: A New Temperature Solid Lubricant Coating for High Temperature Wear Applications

A new solid lubricant coating, NASA PS400, has been developed for high temperature tribological applications. This plasma sprayed coating is a variant of the patented PS304 coating and has been formulated to provide higher density, smoother surface finish and better dimensional stability than PS304. PS400 is comprised of a nickel-molybdenum binder that provides strength, creep resistance and extreme oxidative and dimensional stability. Chromium oxide, silver and barium-calcium fluoride eutectic are added to the binder to form PS400.Tribological properties were evaluated with a pin-on-disk test rig in sliding contact to 650 C. Coating material samples were exposed to air, argon and vacuum at 760 C followed by cross section microscopic analysis to assess microstructure stability. Oil-Free microturbine engine hot section foil bearing tests were undertaken to assess PS400 s suitability for hot foil gas bearing applications. The preliminary results indicate that PS400 exhibits tribological characteristics comparable to the PS304 coating but with enhanced creep resistance and dimensional stability suitable for demanding, dynamic applications.

DellaCorte, C.↗

Cavity-Modulation Autotuner For Hydrogen Maser

Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.

Dick, G. J.↗

NASA Tech Briefs, January 2010

Topics covered include: Cryogenic Flow Sensor; Multi-Sensor Mud Detection; Gas Flow Detection System; Mapping Capacitive Coupling Among Pixels in a Sensor Array; Fiber-Based Laser Transmitter for Oxygen A-Band Spectroscopy and Remote Sensing; Low-Profile, Dual-Wavelength, Dual-Polarized Antenna; Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications; Cellular Reflectarray Antenna; A One-Dimensional Synthetic-Aperture Microwave Radiometer; Electrical Switching of Perovskite Thin-Film Resistors; Two-Dimensional Synthetic-Aperture Radiometer; Ethernet-Enabled Power and Communication Module for Embedded Processors; Electrically Variable Resistive Memory Devices; Improved Attachment in a Hybrid Inflatable Pressure Vessel; Electrostatic Separator for Beneficiation of Lunar Soil; Amorphous Rover; Space-Frame Antenna; Gear-Driven Turnbuckle Actuator; In-Situ Focusing Inside a Thermal Vacuum Chamber; Space-Frame Lunar Lander; Wider-Opening Dewar Flasks for Cryogenic Storage; Silicon Oxycarbide Aerogels for High-Temperature Thermal Insulation; Supercapacitor Electrolyte Solvents with Liquid Range Below -80 C; Designs and Materials for Better Coronagraph Occulting Masks; Fuel-Cell-Powered Vehicle with Hybrid Power Management; Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher; Fuel-Cell Water Separator; Turbulence and the Stabilization Principle; Improved Cloud Condensation Nucleus Spectrometer; Better Modeling of Electrostatic Discharge in an Insulator; Sub-Aperture Interferometers; Terahertz Mapping of Microstructure and Thickness Variations; Multiparallel Three-Dimensional Optical Microscopy; Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber; Vacuum-Compatible Wideband White Light and Laser Combiner Source System; Optical Tapers as White-Light WGM Resonators; EPR Imaging at a Few Megahertz Using SQUID Detectors; Reducing Field Distortion in Magnetic Resonance Imaging; Fluorogenic Cell-Based Biosensors for Monitoring Microbes; A Constant-Force Resistive Exercise Unit; GUI to Facilitate Research on Biological Damage from Radiation; On-Demand Urine Analyzer; More-Realistic Digital Modeling of a Human Body; and Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets.

Source record↗

Affleck-Dine baryogenesis and inflation in supergravity with strongly stabilized moduli

Constructing models of inflation and/or baryogenesis in the context of N = 1 supergravity is known to be difficult as the finite energy density during inflation typically generates large (order the Hubble scale) mass terms. This is the well-known η problem in inflation. The same effect gives masses along low energy flat directions of the scalar potential thus potentially preventing Affleck-Dine baryogenesis to occur. It has been shown that adding a chiral multiplet S coupled to the inflaton (with a shift symmetry) can serve to stabilize the inflationary potential and allows one to derive simple inflationary potentials without an η problem. Here, we show that by coupling the same stabilizing field S to the flat direction, may naturally lead to a negative mass-squared contribution to the flat direction thus generating the necessarily large vacuum expectation value needed to realize Affleck-Dine baryogenesis. We trace the evolution of the inflaton, stabilizer, and flat direction field, as well as a Polonyi-like modulus responsible for soft supersymmetry breaking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Using Lag Compensator in Orbit Feedback

Growing demand on the beam orbit stability requires higher loop gain inside the operational bandwidth. However, increasing the gain leads to the increase of the unity gain frequency and problems with systems stability due to the additional phase shifts caused by the trims (power supplies, eddy currents in vacuum chambers, etc.) and filtering of beam position data. Conventionally employed systems have 20 dB/decade slope near the unity gain providing 90 degrees phase shift which is sufficient for stability. Increase of the slope to 40 dB/decade by adding additional pole into the signal chain increases the phase shift to 180 degrees and makes system unstable. Utilizing one or more lag compensators allows to increase the gain while keeping phase margin acceptable. The paper provides more details on the proposed solution as well as simulations of how the transients will be modified.

43 PARTICLE ACCELERATORS↗

Solid Lubrication by Multiwalled Carbon Nanotubes in Air and in Vacuum for Space and Aeronautics Applications

To evaluate recently developed aligned multiwalled carbon nanotubes (MWNTs) and dispersed MWNTs for solid lubrication applications, unidirectional sliding friction experiments were conducted with 440 C stainless steel balls and hemispherical alumina-yttria stabilized zirconia pins in sliding contact with the MWNTs deposited on quartz disks in air and in vacuum. The results indicate that MWNTs have superior solid lubrication friction properties and endurance lives in air and vacuum under dry conditions. The coefficient of friction of the dispersed MWNTs is close to 0.05 and 0.009 in air and in vacuum, respectively, showing good dry lubricating ability. The wear life of MWNTs exceeds 1 million passes in both air and vacuum showing good durability. In general, the low coefficient of friction can be attributed to the combination of the transferred, agglomerated patches of MWNTs on the counterpart ball or pin surfaces and the presence of tubular MWNTs at interfaces.

Miyoshi, Kazuhisa↗

Performance, Stability, and Plume Characterization of the HERMeS Thruster with Boron Nitride Silica Composite Discharge Channel

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.

ion engines↗

Quantum control and Berry phase of electron spins in rotating levitated diamonds in high vacuum

Levitated diamond particles in high vacuum with internal spin qubits have been proposed for exploring macroscopic quantum mechanics, quantum gravity, and precision measurements. The coupling between spins and particle rotation can be utilized to study quantum geometric phase, create gyroscopes and rotational matter-wave interferometers. However, previous efforts in levitated diamonds struggled with vacuum level or spin state readouts. To address these gaps, we fabricate an integrated surface ion trap with multiple stabilization electrodes. This facilitates on-chip levitation and, for the first time, optically detected magnetic resonance measurements of a nanodiamond levitated in high vacuum. The internal temperature of our levitated nanodiamond remains moderate at pressures below 10 -5 Torr. We have driven a nanodiamond to rotate up to 20 MHz (1.2 × 10 9 rpm), surpassing typical nitrogen-vacancy (NV) center electron spin dephasing rates. Using these NV spins, we observe the effect of the Berry phase arising from particle rotation. In addition, we demonstrate quantum control of spins in a rotating nanodiamond. These results mark an important development in interfacing mechanical rotation with spin qubits, expanding our capacity to study quantum phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LiOH corrosion growth and thermal stability investigated by diffuse reflectance infrared Fourier Transform (DRIFT) spectroscopy

In this period, we have measured the kinetics of LiOH corrosion growth on LiH substrate at 35 ppm of moisture for over 2 months. The serial DRIFT spectra are being analyzed to build the growth kinetics for LiOH interfacial states, surface states, and bulk states. Physical chemistry insight is being employed to describe the observed parabolic-linear growth of the corrosion layer grown on LiH samples that have been previously vacuum baked then re-exposed to low moisture over a long time. The thermal stabilities of LiOH interfacial states, surface states, and bulk states are also being quantified by measuring the reduction in LiOH DRIFT signals as a function of vacuum level and temperature, and will be needed to add an on/off switch to the current outgassing modeling.

36 MATERIALS SCIENCE↗

Dissipative Phase Transition in the Two-Photon Dicke Model

We explore the dissipative phase transition of the two-photon Dicke model, a topic that has garnered significant attention recently. Our analysis reveals that while single-photon loss does not stabilize the intrinsic instability in the model, the inclusion of two-photon loss restores stability, leading to the emergence of superradiant states, which coexist with the normal vacuum states. Using a second-order cumulant expansion for the photons, we derive an analytical description of the system in the thermodynamic limit, which agrees well with the exact calculation results. Additionally, we present the Wigner function for the system, shedding light on the breaking of the 𝑍4 symmetry inherent in the model. These findings offer valuable insights into stabilization mechanisms in open quantum systems and pave the way for exploring complex nonlinear dynamics in two-photon Dicke models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of Leak Test Methods for the International Space Station (ISS) Elements, Systems and Components

The International Space Station (ISS has Qualification and Acceptance Environmental Test Requirements document, SSP 41172 that includes many environmental tests such as Thermal vacuum & Cycling, Depress/Repress, Sinusoidal, Random, and Acoustic Vibration, Pyro Shock, Acceleration, Humidity, Pressure, Electromatic Interference (EMI)/Electromagnetic Compatibility (EMCO), etc. This document also includes (13) leak test methods for Pressure Integrity Verification of the ISS Elements, Systems, and Components. These leak test methods are well known, however, the test procedure for specific leak test method shall be written and implemented paying attention to the important procedural steps/details that, if omitted or deviated, could impact the quality of the final product and affect the crew safety. Such procedural steps/details for different methods include, but not limited to: - Sequence of testing, f or example, pressurization and submersion steps for Method I (Immersion); - Stabilization of the mass spectrometer leak detector outputs fo r Method II (vacuum Chamber or Bell jar); - Proper data processing an d taking a conservative approach while making predictions for on-orbit leakage rate for Method III(Pressure Change); - Proper Calibration o f the mass spectrometer leak detector for all the tracer gas (mostly Helium) Methods such as Method V (Detector Probe), Method VI (Hood), Method VII (Tracer Probe), Method VIII(Accumulation); - Usage of visibl ility aides for Method I (Immersion), Method IV (Chemical Indicator), Method XII (Foam/Liquid Application), and Method XIII (Hydrostatic/Visual Inspection); While some methods could be used for the total leaka ge (either internal-to-external or external-to-internal) rate requirement verification (Vacuum Chamber, Pressure Decay, Hood, Accumulation), other methods shall be used only as a pass/fail test for individual joints (e.g., welds, fittings, and plugs) or for troubleshooting purposes (Chemical Indicator, Detector Probe, Tracer Probe, Local Vacuum Chamber, Foam/Liquid Application, and Hydrostatic/Visual Inspection). Any isolation of SSP 41172 requirements have led to either retesting of hardware or accepting a risk associated with the potential system or component pressure integrity problem during flight.

Underwood, Steve↗

Effects of graphitization on the environmental stability of brominated pitch-based fibers

The residual bromine graphite intercalation compounds of high modulus pitch-based fibers (Amoco P-55, P-75, P-100, and P-120) were formed and their resistances were monitored under a variety of environmental conditions. A threshold graphitization was observed below which the bromination reaction does not occur to an appreciable extent. The graphitization of the P-55 fibers falls below that threshold, precluding an extensive reaction. The P-75, P-100, and P-120 fibers all form bromination compounds which are stable at ambient conditions, under vacuum, and under high humidity (100 percent humidity at 60 C). The thermal stability of the resistivity increased with decreasing graphitization, with the stable temperature for P-120 being 100 C; for P-100, 200 C; and for P-75, 250 C. When cost is a consideration, bromination of pitch-based fibers is an economical way to achieve low resistivities.

Gaier, J. R.↗

Effects of deposition temperature on the effectiveness of hydrogen doping in Ga-doped ZnO thin films

Gallium-doped zinc oxide thin films were prepared on glass substrates by dc magnetron sputtering under various hydrogen contents in sputtering ambient. The carrier concentration of the films deposited at low-temperatures (80 and 160 deg. C) was increased due to the incorporation of hydrogen atoms, acting as shallow donors. A low resistivity of 4.0x10{sup -4} {Omega} cm was obtained for the film grown at 160 deg. C with H{sub 2} 10%, which has a carrier concentration of 8.2x10{sup 20}/cm{sup 3}. The beneficial effect of hydrogen doping was not observed for the films deposited at 270 deg. C. Both carrier concentration and mobility were decreased by the addition of hydrogen gas in the sputtering ambient. Variations in the electrical transport properties upon vacuum annealing showed that the difference is attributed to the thermal stability of interstitial hydrogen atoms in the films. The hydrogen incorporation was found to induce the lattice expansion and the free carrier absorption in near infrared range. The investigation of the structural and optical properties of the films upon annealing also revealed that the incorporated hydrogen atoms are unstable at high temperature, which is consistent with the results obtained in the electrical properties.

36 MATERIALS SCIENCE↗

QCD sum rule calculation of quark-gluon three-body components in the B-meson wave function

We discuss the QCD sum rule calculation of the heavy-quark effective theory parameters {lambda}{sub E} and {lambda}{sub H}, which represent quark-gluon three-body components in the B-meson wave function. We update the sum rules for {lambda}{sub E,H} calculating the new higher-order contributions to the operator product expansion for the corresponding correlator, i.e., the order {alpha}{sub s} radiative corrections to the Wilson coefficients associated with the dimension-5 quark-gluon mixed condensate, and the power corrections due to the dimension-6 vacuum condensates. We find that the new radiative corrections significantly improve stability of the corresponding Borel sum rules, modifying the values of {lambda}{sub E,H}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature-dependent growth of hexagonal and monoclinic gallium sulfide films by pulsed-laser deposition

We demonstrate the selective, pulsed-laser deposition of hexagonal GaS and monoclinic Ga2S3 films on sapphire substrates from a single Ga 2 S 3 target in high-vacuum conditions. Growth at substrate temperatures below 550 °C causes GaS film formation, which indicates non-stoichiometric transfer from the target to the film. Surprisingly, stoichiometric transfer occurs at substrate temperatures above 650 °C with monoclinic Ga 2 S 3 as the preferred, higher S-content phase. Through a series of growth and annealing experiments, we show that GaS nucleation under S-deficient conditions leads to the preferred growth of this layered, hexagonal phase below 550 °C. Furthermore, GaS films annealed above 650 °C under high vacuum are transformed to Ga 2 S 3 , reflecting the greater stability of the monoclinic phase. By first growing Ga 2 S 3 at a higher temperature and subsequently growing GaS at a lower temperature, we can fabricate GaS/Ga 2 S 3 heterostructures in a single growth process.

36 MATERIALS SCIENCE↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Models of the Dynamics of Spatially Separated Broadband Electromagnetic Fields Interacting with Resonant Atoms

The Markov model of spontaneous emission of an atom localized in a spatial region with a broadband electromagnetic field with zero photon density is considered in the conditions of coupling of the electromagnetic field with the broadband field of a neighboring space. The evolution operator of the system and the kinetic equation for the atom are obtained. It is shown that the field coupling constant affects the rate of spontaneous emission of the atom, but is not manifested in the atomic frequency shift. The analytic expression for the radiative decay constant for the atom is found to be analogous in a certain sense to the expression for the decay constant for a singly excited localized ensemble of identical atoms in the conditions when the effect of stabilization of its excited state by the Stark interaction with the vacuum broadband electromagnetic field is manifested. The model is formulated based on quantum stochastic differential equations of the non- Wiener type and the generalized algebra of the Ito differential of quantum random processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rugged, low-conductance, heat-flow probe

Lightweight, compact probe structure has low thermal conductance to enable accurate measurement of slight temperature gradients. Probe combines ruggedness, high precision, accuracy, and stability. Device can withstand vibration, shock, acceleration, temperature extremes, and high vacuums, and should interest industrial engineers and geologists.

Boudreau, E. J.↗